• 제목/요약/키워드: MicroSeal

검색결과 28건 처리시간 0.024초

일반국도에 적용한 마이크로서페이싱공법과 폴리머슬러리실공법에 대한 현장 공용성 평가 (Field Performance Evaluation of Micro-surfacing Method and Polymer Slurry Seal Method Used in National Highway)

  • 손현장;김용주;백종은;임재규;김부일
    • 한국도로학회논문집
    • /
    • 제17권1호
    • /
    • pp.17-24
    • /
    • 2015
  • PURPOSES : Recently, crack, rutting, and stripping problems from the surface of asphalt pavements in National highway are observed and they affect the drivers to feel uncomfortable on the road. Surface treatments are recommended to use in distressed pavements due to cost-effective, and improvement of surface performance. The purpose of this study is to evaluate the performance of micro-surfacing and polymer slurry seal treatments for distressed asphalt pavements. METHODS : Surface conditions and friction resistance are evaluated for asphalt pavements treated with micro-surfacing and polymer slurry seal mixes in National highway 30 line and 34 line. Visual observation is conducted and surface performance is measured by PES (Performance Evaluation Surveyor) in terms of crack ratio, rutting and IRI(International Roughness Index). BPN(British Pendulum Number) is measured by BPT(British Pendulum Tester) to evaluate the friction resistance in the field. RESULTS : The surface evaluation results are presented for asphalt pavement treated with micro-surfacing and polymer slurry seal treatments in National highway 30 line and 34 line. Based on the visual observation, micro-surfacing and polymer slurry seal treatments show better improvements in terms of cracks and stripping. Based on the surface conditions measured by PES vehicle, the surface performance of micro-surfacing treatments improves from 53.3% to 54.2% and the surface performance of polymer slurry seal treatments improves from 21.6% to 59.7%. However, the friction resistance of both micro-surfacing and polymer slurry seal treatments decreases from 2.5% to 6.7%. Further, it should be verified to produce the surface exposed with aggregates during the construction process of both treatment methods in the field. CONCLUSIONS : Based on the performance evaluation results in the filed, the surface performance of asphalt pavement treated with micro-surfacing and polymer slurry seal treatments improves from 21.6% to 59.7%. While, the friction resistance of asphalt pavement treated with micro-surfacing and polymer slurry seal treatments does not improve. It can be concluded that current micro-surfacing and polymer slurry seal treatments would improve surface performance but would not improve the friction resistance.

탄성중합체 시일 표면의 미세 딤플에 대한 최적설계 (Optimum micro dimple configuration on the elastomer seal surface)

  • 유대원
    • Design & Manufacturing
    • /
    • 제14권4호
    • /
    • pp.1-10
    • /
    • 2020
  • The seal plays a role in preventing oil leakage when the lip and the rotating shaft come into contact with the fluid and air pressure. Recently, micro dimples or micro pockets are processed and used on the lubrication surfaces of thrust bearings, mechanical bearings, and piston rings. Compared to a smooth surface, micro dimples reduce friction and increase the life of parts. This paper analyzed various kinds of micro dimple shapes on the sealing surface, i.e. circle, rectangle, triangle, and trapezoid. For this purpose, Introduced the design of experiments to work out a micro dimple configuration, unlikely to be damaged from cracks and low in contact stress. As a result, the triangular dimple showed the best results. Optimal factors were dimple size 0.15 mm, dimple depth 0.0383 mm, dimple density 40%, and the maximum equivalent stress was 9.1455 MPa, and the maximum contact pressure was 9.6612 MPa. This paper analyzed the optimal shape of dimples by finite element analysis. As a research project, experiments and comparative analysis of micro dimple shapes are needed.

핵연료 조사시험용 온도센서 피복재의 레이저용접 연구 (A Study on the Laser Welding of Cladding Tube with Temp. Sensor for Fuel Irradiation Test)

  • 김수성;이철용;김웅기;이정원;고진현;이영호
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2005년도 춘계학술발표대회 개요집
    • /
    • pp.106-108
    • /
    • 2005
  • The instrumented fuel irradiation test at a research reactor is needed to evaluate the performance of the developed nuclear fuel. The fuel elements can be designed to measure the center line temperature of fuel pellets during the irradiation test by using temperature sensor. The thermal sensor was composed of thermocouple and sensor sheath. Micro-laser welding technology was adopted to seal between seal tube and sensor sheath with thickness of 0.15 mm. The soundness of welding area has to be confirmed to prevent fission gas of the fuel from leaking out of the element during the fuel irradiation test. In this study, fundamental data for micro-laser welding technology was proposed to seal temperature sensor sheath of the instrumented fuel element. And, micro-laser welding for dissimilar metals between sensor sheath and seal tube was characterized by investigating welding conditions. Moreover, the micro-laser welding technology is closely related to advanced industry. It is expected that the laser material processing technology will be adopted to various a pplications in the industry.

  • PDF

열연화시킨 근관충전방법에 따른 근단폐쇄성에 관한 연구 (A COMPARISON OF THE APICAL SEALING ABILITY OF OBTURATION TECHNIQUES BY THERMALLY SOFTENED GUTTA PERCHA)

  • 백승호
    • Restorative Dentistry and Endodontics
    • /
    • 제23권2호
    • /
    • pp.607-617
    • /
    • 1998
  • The purpose of this study was to evaluate the apical sealing ability of lateral condensation method, vertical condensation method, and MicroSeal obturation system. Sixty-four extracted anterior teeth were instrumented to #40 using Profile. Three groups of 20 teeth were obturated by lateral condensation technique, vertical condensation technique, and and MicroSeal obturation system. Control group were not obturated. Teeth were immersed in resorcinol-formaldehyde resin for 5 days at $4^{\circ}C$, and the resin was allowed to polymerize completely for 4 days at room temperature. Teeth were ground horizontally at 1,5mm(level 1), 2.5mm(level 2), and 3.5mm(level 3) from the anatomic apex and examined with a stereomicroscope at X40 magnification. The photographs were taken a at X40 magnification of the filling in each level and scanned. The leakage area, which was filled with the resin, was measured at each of the three levels. Each ratio of leakage was evaluated by calculating the ratio of thearea of the resin to the total area of the canal and was analyzed statistically. The results were as followed: 1. Vertical condensation group had significantly higher percentage of the area which was obturated by gutta percha than other two technique at each level. 2. At the level 1, there was the greatest leakage in the lateral condensation group, but there was no statistically significant(P>0.05) 3. At the level 2, there was the least leakage in the MicroSeal group, and the most leakage in the lateral condensation group. There was statistically significant difference between the MicroSeal group and the lateral condensation group(P<0.05). 4. At the level 3, there was least leakage in the vertical condensation group, and the most leakage in the lateral condensation group. There was statistically significant difference between the vertical condensation group and the lateral condensation group(P<0.05).

  • PDF

A micro-computed tomographic study of remaining filling materials of two bioceramic sealers and epoxy resin sealer after retreatment

  • Kim, KyungJae;Kim, Da Vin;Kim, Sin-Young;Yang, SungEun
    • Restorative Dentistry and Endodontics
    • /
    • 제44권2호
    • /
    • pp.18.1-18.9
    • /
    • 2019
  • Objective: This study evaluated the presence of residual root canal filling material after retreatment using micro-computed tomography (micro-CT). Materials and Methods: Extracted human teeth (single- and double-rooted, n = 21/each; C-shaped, n = 15) were prepared with ProFile and randomly assigned to three subgroups for obturation with gutta-percha and three different sealers (EndoSeal MTA, EndoSequence BC sealer, and AH Plus). After 10 days, the filling material was removed and the root canals were instrumented one size up from the previous master apical file size. The teeth were scanned using micro-CT before and after retreatment. The percentage of remaining filling material after retreatment was calculated at the coronal, middle, and apical thirds. Data were analyzed using the Kruskal-Wallis test and Mann-Whitney U test with Bonferroni post hoc correction. Results: The tested sealers showed no significant differences in the percentage of remaining filling material in single- and double-rooted teeth, although EndoSeal MTA showed the highest value in C-shaped roots (p < 0.05). The percentage of remaining filling material of AH Plus and EndoSeal MTA was significantly higher in C-shaped roots than in single- or double-roots (p < 0.05), while that of BC sealer was similar across all root types. EndoSeal MTA showed the highest values at the apical thirds of single- and double-roots (p < 0.05); otherwise, no significant differences were observed among the coronal, middle, and apical thirds. Conclusions: Within the limitations of this study, a large amount of EndoSeal MTA remained after retreatment, especially in C-shaped root canals.

항균물질을 함유한 지각과민처치제에 대한 항균효과 및 세포독성 (Antibacterial Effect and Cytotoxicity of Desensitizer Containing Antimicrobial)

  • 이현옥;박지영
    • 치위생과학회지
    • /
    • 제15권2호
    • /
    • pp.238-245
    • /
    • 2015
  • 본 연구는 지각과민처치제에 항균 물질을 첨가하여 항균실험 및 지각과민처치제의 세포독성실험을 실시하여 다음과 같은 결과를 얻었다. 항균실험에서는 Micro Prime은 항균 약물의 농도가 높을수록 항균력도 높게 나타나 각 그룹간의 항균 범위는 통계적인 유의차를 나타내었다(p<0.05). Hurri Seal에서는 gallic acid 항균 약물 농도가 높을수록 항균력이 높게 나타났지만(p<0.05), tetracycline을 함유한 desensitizer에서는 농도가 높을수록 항균효과는 떨어지는 것으로 나타났다(p<0.05). 또한 chlorhexidine과 cetylpyridinium chloride에서는 대조군에서만 차이를 나타내고(p<0.05), 각 실험군에서 차이를 나타내지 않았다. 세포독성도를 평가한 결과 Micro Prime은 미약한 세포독성을 나타냈으며, Hurri Sea은 심한 세포독성을 나타냈다. 이상의 연구결과로 지각과민처치제에 항균물질을 첨가할 경우 우수한 항균력이 나타났기 때문에 지각과민 환자의 동통을 줄여 줄 것으로 사료되며 항균성을 가진 지각과민처치제로 사용이 가능할 것으로 판단된다.

시일과 스틸면 사이의 구형 마멸입자에 의한 접촉해석 (Contact Analysis between Rubber Seal, a Spherical Wear Particle and Steel Surface)

  • 박태조;유재찬;조현동
    • Tribology and Lubricants
    • /
    • 제24권6호
    • /
    • pp.297-301
    • /
    • 2008
  • In many dynamic seals such as lip seal and compression packings, it is well known that wear occur at the surface of heat treated steel shaft as results of the intervened wear particle. It is widely understood that the dominant wear mechanism related in sealing surfaces is abrasive wear. However, little analytical and experimental studies about this problems have been done until now. In this paper, a contact analysis is carried out using MARC to investigate the wear mechanism in contact seal applications considering elastomeric seal, a elastic perfect-plastic micro-spherical particle and steel surface. Deformed seal shapes, contact and von-Mises stress distributions for various particle sizes and interference are showed. The maximum von-Mises stress within steel shaft was exceeded its yield strength and plastic deformation occurred at steel surface. Therefore, the sealing surface can be also worn by sub-surface fatigue due to wear particles together with well known abrasion. The numerical methods and models used in this paper can be applied in design of dynamic sealing systems, and further intensive studies are required.

계장핵연료 조사시험용 실튜브 레이저용접기술 (Laser Welding of Seal Tube for Instrumented Irradiation Fuel Test)

  • 김수성;이철용;김웅기;박근일;고진현;서준석
    • Journal of Welding and Joining
    • /
    • 제23권6호
    • /
    • pp.43-48
    • /
    • 2005
  • This work was carried out to obtain sound welds and to select a most suitable binary metal joint among three different dissimilar binary metal combinations such as Zr-4/Ta, Mo/Ta and Ti/Ta(seal tube/sensor sheath) joints fur the instrumented nuclear fuel irradiation test. To do this, Taguchi experimental method was employed to optimize the experimental data. In addition, metallography, micro-focus x-ray radiography and hardness test were conducted to examine the welds. From the weld bead appearance, penetration depth and bead width as well as weld defects standpoint, Zr-4/Ta joint is suggested for the circumferential joining between a seal tube and a sensor sheath. The optimized welding parameters based on Zr-4/Ta joint are suggested as well.

오일시일의 동적거동에 관한 실험적 연구 (Experimental Study on the Dynamic Behaviour of Oil Seals)

  • 김청균;심우전
    • Tribology and Lubricants
    • /
    • 제11권3호
    • /
    • pp.54-58
    • /
    • 1995
  • This paper deals with an experimental study on the dynamic behaviour of rubber oil seals when the interferences between the shaft and the seal lip as well as the dynamic eccentricities are present. The micro-separation of the sealing gap was observed with the aid of an image processing apparatus. The temperature of the seal lip edge, friction torque and the dynamic sealing gap profile are experimentally investigated for the initial interference and the shaft eccentricity. The data was simultaneously measured under the operation conditions. Experimental results show that, as the shaft speed is increased, the leakage of sealed fluids is increasing for a certain range of shaft speeds. The test data indicates that the shaft eccentricity clearly produces the gap separation between the shaft and the seal lip which is unable to follow the radial displacement of shaft as the shaft speed increases.