• 제목/요약/키워드: Micro-imaging

검색결과 291건 처리시간 0.023초

미세 생체유동 해석을 위한 첨단 유동가시화기법 (Advanced Flow Visualization Techniques for Diagnosing Microscale Biofluid Flows)

  • 이상준
    • 대한기계학회논문집B
    • /
    • 제33권1호
    • /
    • pp.1-8
    • /
    • 2009
  • Recently microscale biofluid flows have been receiving large attention in various research areas. However, most conventional imaging techniques are unsatisfactory due to difficulties encountered in the visualization of microscale biological flows. Recent advances in optics and digital image processing techniques have made it possible to develop several advanced micro-PIV/PTV techniques. They can be used to get quantitative velocity field information of various biofluid flows from visualized images of tracer particles. In this paper, as new advanced micro-PIV techniques suitable for biofluid flow analysis, the basic principle and typical applications of the time-resolved micro-PIV and X-ray micro-PIV methods are explained. As a 3D velocity field measurement technique for measuring microscale flows, holographic micro-PTV method is introduced. These advanced PIV/PTV techniques can be used to reveal the basic physics of various microscale biological flows and will play an important role in visualizing veiled biofluid flow phenomena, for which conventional methods have many difficulties to analyze.

How image-processing parameters can influence the assessment of dental materials using micro-CT

  • Torres, Fernanda Ferrari Esteves;Jacobs, Reinhilde;EzEldeen, Mostafa;de Faria-Vasconcelos, Karla;Guerreiro-Tanomaru, Juliane Maria;dos Santos, Bernardo Camargo;Tanomaru-Filho, Mario
    • Imaging Science in Dentistry
    • /
    • 제50권2호
    • /
    • pp.161-168
    • /
    • 2020
  • Purpose: The aim of this study was to evaluate the influence of voxel size and different post-processing algorithms on the analysis of dental materials using micro-computed tomography (micro-CT). Materials and Methods: Root-end cavities were prepared in extracted maxillary premolars, filled with mineral trioxide aggregate (MTA), Biodentine, and Intermediate Restorative Material (IRM), and scanned using micro-CT. The volume and porosity of materials were evaluated and compared using voxel sizes of 5, 10, and 20 ㎛, as well as different software tools(post-processing algorithms). The CTAn or MeVisLab/Materialise 3-matic software package was used to perform volume and morphological analyses, and the CTAn or MeVisLab/Amira software was used to evaluate porosity. Data were analyzed using 1-way ANOVA and the Tukey test(P<0.05). Results: Using MeVisLab/Materialise 3-matic, a consistent tendency was observed for volume to increase at larger voxel sizes. CTAn showed higher volumes for MTA and IRM at 20 ㎛. Using CTAn, porosity values decreased as voxel size increased, with statistically significant differences for all materials. MeVisLab/Amira showed a difference for MTA and IRM at 5 ㎛, and for Biodentine at 20 ㎛. Significant differences in volume and porosity were observed in all software packages for Biodentine across all voxel sizes. Conclusion: Some differences in volume and porosity were found according to voxel size, image-processing software, and the radiopacity of the material. Consistent protocols are needed for research evaluating dental materials.

렌즈프리 그림자 이미징 기술을 이용한 실시간 미세조류 응집현상 분석법 (Real-time Micro-algae Flocculation Analysis Method Based on Lens-free Shadow Imaging Technique (LSIT))

  • 서동민;오상우;동단단;이재우;서성규
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제19권4호
    • /
    • pp.341-348
    • /
    • 2016
  • 미세조류는 대체에너지를 위한 생물자원 중 하나로 다양한 분야에서 관련된 연구가 활발히 진행되고 있다. 미세조류의 상태를 분석하기 위한 방법으로는 계수법, 스크리닝법, 응집법 등이 사용되고 있는데, 이 중 응집법은 적조 제거제 연구, 미세조류 자원화 연구 등에 효과적으로 이용되고 있다. 미세조류의 응집 상태 분석에는 현재 분광광도법이 주로 사용되고 있는데, 이는 미세조류의 응집 상태를 광학밀도 계측을 통해 분석하는 방법으로 미세조류 계수법에 비해 소요되는 분석 시간은 작지만, 측정 결과의 오차가 상대적으로 큰 단점을 갖고 있다. 본 논문에서는 이러한 단점을 개선하기 위해서 렌즈프리 그림자 이미징 기술을 이용하여 미세조류의 응집 현상을 실시간으로 분석하는 방법을 제안한다. 본 연구에서는 렌즈프리 그림자 이미지를 이용하여 단일 미세조류의 측정과 응집 미세조류 측정이 동시에 가능함을 현미경 이미지와의 비교를 통해 입증하였다. 또한, 해당 기술을 기반으로 미세조류의 응집 현상을 정량적으로 분석할 수 있는 세 가지의 그림자 파라미터(플록들의 개수, 플록들의 유효면적 및 최대크기 플록의 면적)를 제안하였다. 각 파라미터의 유효성은 응집 효율이 다른 응집제를 이용한 실험을 통해 시간에 따른 미세조류의 응집상태를 실시간으로 분석하여 입증할 수 있음을 확인하였다.

Design and Experimental Demonstration of Coaxially Folded All-reflective Imaging System

  • Xiong, Yupeng;Dai, Yifan;Chen, Shanyong;Tie, Guipeng
    • Current Optics and Photonics
    • /
    • 제3권3호
    • /
    • pp.227-235
    • /
    • 2019
  • With slimmer, lighter and all-reflective imaging systems in high demand for consumer and military applications, coaxially folded optical image systems are widely considered because they can extend focal length and reduce track length. Most of these systems consist of multiple surfaces, and these surfaces are machined on one element or grouping processing on two elements. In this paper, we report and first experimentally demonstrate an all-aluminum all-reflective optical system which consists of two optical elements, with two high order aspherical surfaces in each element. The coaxially folded system is designed with Seidel aberration theory and advanced optimization with Zemax. The system is made of all-aluminum material processing by single point diamond turning (SPDT). On this basis, we completed the system integration and performed an imaging experiment. The final system has the advantages of short track length and long focal length and broad application prospects in the micro-unmanned aerial vehicle field.

3-D Surface Profile Measurement Using An Acousto-optic Tunable Filter Based Spectral Phase Shifting Technique

  • Kim, Dae-Suk;Cho, Yong-Jai
    • Journal of the Optical Society of Korea
    • /
    • 제12권4호
    • /
    • pp.281-287
    • /
    • 2008
  • An acousto-optic tunable filter based 3-D micro surface profile measurement using an equally spaced 5 spectral phase shifting is described. The 5-bucket spectral phase shifting method is compared with a Fourier-transform method in the spectral domain. It can provide a fast measurement capability while maintaining high accuracy since it needs only 5 pieces of spectrally phase shifted imaging data and a simple calculation in comparison with the Fourier transform method that requires full wavelength scanning data and relatively complicated computation. The 3-D profile data of micro objects can be obtained in a few seconds with an accuracy of ${\sim}10nm$. The 3-D profile method also has an inherent benefit in terms of being speckle-free in measuring diffuse micro objects by employing an incoherent light source. Those simplicity and practical applicability is expected to have diverse applications in 3-D micro profilometry such as semiconductors and micro-biology.

Zoom-in X-ray Micro Tomography System

  • Chun, In-Kon;Lee, Sang-Chul;Park, Jeong-Jin;Cho, Min-Hyoung;Lee, Soo-Yeol
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권5호
    • /
    • pp.295-300
    • /
    • 2005
  • We introduce an x-ray micro tomography system capable of high resolution imaging of a local region inside a small animal. By combining two kinds of projection data, one from a full field-of-view (FOV) scan of the whole body and the other from a limited FOV scan of the region of interest, we have obtained zoomed-in images of the region of interest without any contrast a nomalies. We have integrated a micro tomography system using a micro-focus x-ray source, a $1248\times1248$ flat-panel x-ray detector, and a precision scan mechanism. Using the cross-sectional images taken with the zoom-in micro tomography system, we measured trabecular thicknesses of femur bones in postmortem rats. To compensate the limited spatial resolution in the zoom-in micro tomography images, we used the fuzzy distance transform for the calculation of the trabecular thickness. To validate the trabecular thickness measurement with the zoom-in micro tomography images, we compared the measurement results with the ones obtained from the conventional micro tomography images of the extracted bone samples.

Micro-Structure Measurement and Imaging Based on Digital Holography

  • Kim, Kyeong-Suk;Jung, Hyun-Chul;Chang, Ho-Seob;Kee, Chang-Doo;Akhter, Naseem
    • 비파괴검사학회지
    • /
    • 제30권3호
    • /
    • pp.257-260
    • /
    • 2010
  • Advancements in the imaging and computing technology have opened the path to digital holography for non-destructive investigations of technical samples, material property measurement, vibration analysis, flow visualization and stress analysis in aerospace industry which has widened the application of digital holography in the above fields. In this paper, we demonstrate the non-destructive investigation and micro-structure measurement application of digital holography to the small particles and a biological sample. This paper gives a brief description of the digital holograms recorded with this system and illustratively demonstrated.

Integral-floating Display with 360 Degree Horizontal Viewing Angle

  • Erdenebat, Munkh-Uchral;Baasantseren, Ganbat;Kim, Nam;Kwon, Ki-Chul;Byeon, Jina;Yoo, Kwan-Hee;Park, Jae-Hyeung
    • Journal of the Optical Society of Korea
    • /
    • 제16권4호
    • /
    • pp.365-371
    • /
    • 2012
  • A three-dimensional integral-floating display with 360 degree horizontal viewing angle is proposed. A lens array integrates two-dimensional elemental images projected by a digital micro-mirror device, reconstructing three-dimensional images. The three-dimensional images are then relayed to a mirror via double floating lenses. The mirror rotates in synchronization with the digital micro-mirror device to direct the relayed three-dimensional images to corresponding horizontal directions. By combining integral imaging and the rotating mirror scheme, the proposed method displays full-parallax three-dimensional images with 360 degree horizontal viewing angle.

최신 화상 재료의 소개 -마이크로 캡슐 토너- (Introduction of the Advanced Imaging Materials -Micro-encapsulating Treatment of Toner-)

  • 이용규;정경모;코세키 켄이치
    • 펄프종이기술
    • /
    • 제44권6호
    • /
    • pp.79-86
    • /
    • 2012
  • The aim of this general remarks is to introduce the results concerning the thermo physical, charging, developing and fusing characteristics of micro-encapsulated (MC) model toners in order to apply to the toner of electrophotographic system at the condition of a low temperature. In order to clarify the fusing mechanism of MC toner, rheological analysis of the toner was chosen. It was suggested that MC toner had a different fusing mechanism compared with non-MC toner. Some kinds of MC model toners showed a good result on adhesion test as well as cohesion test. Also, it was possible to get the good charging and development characteristic of MC toner for printing test with laser printer.

고해상도 FMCW 레이더 영상 합성과 CW 신호 분석 실험을 통한 드론의 탐지 및 식별 연구 (Experimental Study of Drone Detection and Classification through FMCW ISAR and CW Micro-Doppler Analysis)

  • 송경민;문민정;이우경
    • 한국군사과학기술학회지
    • /
    • 제21권2호
    • /
    • pp.147-157
    • /
    • 2018
  • There are increasing demands to provide early warning against intruding drones and cope with potential threats. Commercial anti-drone systems are mostly based on simple target detection by radar reflections. In real scenario, however, it becomes essential to obtain drone radar signatures so that hostile targets are recognized in advance. We present experimental test results that micro-Doppler radar signature delivers partial information on multi-rotor platforms and exhibits limited performance in drone recognition and classification. Afterward, we attempt to generate high resolution profile of flying drone targets. To this purpose, wide bands radar signals are employed to carry out inverse synthetic aperture radar(ISAR) imaging against moving drones. Following theoretical analysis, experimental field tests are carried out to acquire real target signals. Our preliminary tests demonstrate that high resolution ISAR imaging provides effective measures to detect and classify multiple drone targets in air.