• Title/Summary/Keyword: Micro-hardness

Search Result 731, Processing Time 0.024 seconds

Fabrication and Mechanical Properties of a Nanostructured TiN-AlN Composite by Pulsed Current Activated Sintering (펄스전류활성 소결에 의한 나노구조 TiN-AlN 복합재료 제조 및 기계적 특성)

  • Kim, Wonbaek;Suh, Chang-Yul;Roh, Ki-Min;Lim, Jae-Won;Shim, Hyun-Bo;Park, Hyun-Kuk;Shon, In-Jin
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.11
    • /
    • pp.861-866
    • /
    • 2012
  • A dense nanostructured TiN-AlN composite was prepared from high-energy ball milled TiN-AlN mixture powders by pulsed current activated sintering (PCAS). A highly dense TiN-AlN bulk composite was obtained within 2 minutes at $1500^{\circ}C$ with the simultaneous application of 80 MPa pressure and pulsed current. The fine crystalline structure of the TiN-AlN mixture, which was obtained by high-energy milling, was effectively maintained during PCAS and resulted in the enhancement of the mechanical properties. The micro hardness and fracture toughness of TiN-AlN composite were $1780kg/mm^2$ and $5MPa.m^{1/2}$, respectively. The mechanical properties were higher than monolithic AlN or TiN.

The influence of MgO on the radiation protection and mechanical properties of tellurite glasses

  • Hanfi, M.Y.;Sayyed, M.I.;Lacomme, E.;Akkurt, I.;Mahmoud, K.A.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.2000-2010
    • /
    • 2021
  • Mechanical moduli, such as Young's modulus (E), Bulks modulus (B), Shear modulus (S), longitudinal modulus (L), Poisson's ratio (σ) and micro Hardness (H) were theoretically calculated for (100-x)TeO2+x MgO glasses, where x = 10, 20, 30, 40 and 45 mol%, based on the Makishima-Mackenzie model. The estimated results showed that the mechanical moduli and the microhardness of the glasses were improved with the increase of the MgO contents in the TM glasses, while Poisson's ratio decreased with the increase in MgO content. Moreover, the radiation shielding capacity was evaluated for the studied TM glasses. Thus, the linear attenuation coefficient (LAC), mass attenuation coefficient (MAC), transmission factor (TF) and half-value thickness (𝚫0.5) were simulated for gamma photon energies between 0.344 and 1.406 MeV. The simulated results showed that glass TM10 with 10 mol % MgO possess the highest LAC and varied in the range between 0.259 and 0.711 cm-1, while TM45 glass with 45 mol % MgO possess the lowest LAC and vary in the range between 0.223 and 0.587 cm-1 at gamma photon energies between 0.344 and 1.406 MeV. Furthermore, the BXCOM program was applied to calculate the effective atomic number (Zeff), equivalent atomic number (Zeq) and buildup factors (EBF and EABF) of the glasses. The effective removal cross-section for the fast neutrons (ERCSFN, ∑R) was also calculated theoretically. The received data depicts that the lowest ∑R was achieved for TM10 glasses, where ∑R = 0.0193 cm2 g-1, while TM45 possesses the highest ERCSFN where ∑R = 0.0215 cm2 g-1.

Evaluation of Mechanical Properties and Microstructure Depending on Sintering Heating Rate of IN 939 W Alloy (IN 939 W 합금의 소결 승온 속도에 따른 물리적 특성과 미세조직 분석)

  • Jeon, Junhyub;Lee, Junho;Seo, Namhyuk;Son, Seung Bae;Jung, Jae-Gil;Lee, Seok-Jae
    • Journal of Powder Materials
    • /
    • v.29 no.5
    • /
    • pp.399-410
    • /
    • 2022
  • Changes in the mechanical properties and microstructure of an IN 939 W alloy according to the sintering heating rate were evaluated. IN 939 W alloy samples were fabricated by spark plasma sintering. The phase fraction, number density, and mean radius of the IN 939 W alloy were calculated using a thermodynamic calculation. A universal testing machine and micro-Vickers hardness tester were employed to confirm the mechanical properties of the IN 939 W alloy. X-ray diffraction, optical microscopy, field-emission scanning electron microscopy, Cs-corrected-field emission transmission electron microscopy, and energy dispersive X-ray spectrometry were used to evaluate the microstructure of the alloy. The rapid sintering heating rate resulted in a slightly dispersed γ' phase and chromium oxide. It also suppressed the precipitation of the η phase. These helped to reinforce the mechanical properties.

Characterization of deterioration of concrete lining in tunnel structures (터널 콘크리트 라이닝 구조물의 성능저하 특성)

  • Kim, Dong-Gyou;Jung, Ho-Seop;Bae, Gyu-Jin;Shin, Hyu-Soung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.11 no.4
    • /
    • pp.387-394
    • /
    • 2009
  • The objective of this study is to evaluate the durability and deterioration of concrete lining in the seven conventional tunnels. These tunnels were constructed about 40~70 years ago, and closed about 10~40 years ago. The field investigation and various laboratory testings were performed for this study. It was observed from the visual, examinations that the concrete linings of 7 tunnels were severely deteriorated, such as, cracks, leakages, desquamation, and exploitations. The compressive strengths obtained from rebound hardness method and uniaxial compressive strength test on core specimens largely differed depending on the locations in the tunnel. The maximum compressive strength of concrete lining was greater about 2 times than the minimum compressive strength of concrete lining in the same tunnel. The results of micro-structural analysis showed that the substances deteriorating the concrete lining, such as ettringite and thaumasite, were detected in the concrete lining of tunnel.

A STUDY ON THE CHANGES IN DEGREE OF CONVERSION OF DUAL-CURE RESTORATIVE MATERIALS WITH TIME-ELAPSE (이중중합 수복재의 시간경과에 따른 중합도 변화)

  • Yang, Chul-Ho;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.3
    • /
    • pp.554-563
    • /
    • 1999
  • For the purpose of elucidating the polymerization modes of dual-cure restorative materials and comparing them with single-cure restorative materials, a study was performed on the light-cured composite resin, dual-cure composite resin, dual-cure glass ionomer cement and chemical-cure glass ionomer cement. By measuring the microhardness of each material at 0mm, 1mm and 3mm depth during initial 24 hours with predetermined interval, the state of polymerization and degree of conversion was indirectly evaluated for each material, and obtained results are as follows : 1. All of four materials tested showed significant increase in microhardness after 24hrs compared with just after curing starts. 2. In all materials except Ketac-fil, there showed a significant difference in microhardness between each depth at each time interval. 3. In the test of lap time till final curing for each material, the polymerization process was revealed to last longer in the dual-cure type materials than in single-cure type materials at 3mm depth. Based on the results above, it was demonstrated with materials of dual-cure mode that the degree of conversion increases by successive curing reactions even in the deeper layers where sufficient curing light is impermeable.

  • PDF

A Study on Tensile Restraint Crack Critical Stress Characteristcs of Gravity-Wet-Type Underwater Welded Joints (중력식 습식 수중용접부의 인강구속균열 임계응력 특성에 관한 연구)

  • O, Se-Gyu;Gang, Mun-Ho;Han, Sang-Deok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.2
    • /
    • pp.61-65
    • /
    • 1987
  • In this study, the characteristics of TRC (tensile restraint crack) critical stress in the gravity type underwater wet welding process and in the in-air welding have been investigated for Y, y and 45$^{\circ}$r grooves using the KR Grade A-3 steel plates and the E4303 covered electrodes. The following results were obtained: (1) In the TRC tests, the initial critical stress of Y groove is higher than those of the 45$^{\circ}$r single bebel grooves in both in-air and underwater weldings, and the cold fracture sensitivity is higher in the underwater welding than in the in-air welding. (2) The hardness of underwater weld metal is the highest in heat affected zone is about Hk 365 in the in-air weld but Hk 670 in the underwater weld which is higher for cooling speed is more rapid, resulting in the lower critical stress by increase of fracture sensitivity. (3) The diffusible hydrogen quantity for 48 hours is about 18cc/100g-weld-metal in the in-air welding but 48cc/100g-weld-metal in the underwater welding. So that, in the case of underwater welding the diffusible hydrogen penetrates about 3 times more than that in the in-air welding.

  • PDF

A Study on Tensile Restraint Crack Critical Stress Characteristcs of Gravity-Wet-Type Underwater Welded Joints (중력식 습식 수중용접부의 인강구속균열 임계응력 특성에 관한 연구)

  • Sae Kyoo Oh;Moon Ho Kang;Sang Deok Han
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.2
    • /
    • pp.15-15
    • /
    • 1987
  • In this study, the characteristics of TRC (tensile restraint crack) critical stress in the gravity type underwater wet welding process and in the in-air welding have been investigated for Y, y and 45°r grooves using the KR Grade A-3 steel plates and the E4303 covered electrodes. The following results were obtained: (1) In the TRC tests, the initial critical stress of Y groove is higher than those of the 45°r single bebel grooves in both in-air and underwater weldings, and the cold fracture sensitivity is higher in the underwater welding than in the in-air welding. (2) The hardness of underwater weld metal is the highest in heat affected zone is about Hk 365 in the in-air weld but Hk 670 in the underwater weld which is higher for cooling speed is more rapid, resulting in the lower critical stress by increase of fracture sensitivity. (3) The diffusible hydrogen quantity for 48 hours is about 18cc/100g-weld-metal in the in-air welding but 48cc/100g-weld-metal in the underwater welding. So that, in the case of underwater welding the diffusible hydrogen penetrates about 3 times more than that in the in-air welding.

Quality characteristics of prewashed rice with solution of waxy rice flour (찹쌀 가루 용액으로 세척된 청결미의 품질 특성)

  • Koh, Bong-Kyung
    • Korean Journal of Food Science and Technology
    • /
    • v.33 no.4
    • /
    • pp.455-460
    • /
    • 2001
  • Quality characteristics of rice which was washed with solution of waxy rice flour to improve the quality of long term stored rice, were investigated. 2000 (Hap-Sal) and 1996 crop year rices (Jung Bu Mi) which were pre-washed with water (PWR) and solution of waxy rice flour (PWRW) were compared. Moisture contents of rices showed no difference among rices, and protein contents of PWRW were increased with washing of waxy rice flour solution although PWRW and PWR were processed from the same batch. Micro-structure of rices did not show particular difference enough to explain quality characteristics of rices. Amylogarm of PWR showed higher viscosity than Hap-Sal, which was characteristic properties of long term stored rice. However, viscosity of PWRW was decreased compared to PWR. The reason of decrease must be the effect of waxy rice starch which was imbedded with washing the rice. Color of PWR was higher in lightness (L), whiteness (W) and yellow (b) compared to Hap-Sal and PWRW. However cooked PWR showed decrease of whiteness and increase of yellow. Sensory evaluation of PWRW showed significant improvement of glossiness, stickiness, taste, and overall preference and decrease of yellow and hardness compared to PWR. Above results suggest that the development of PWRW will improve the quality of pre- washed rice.

  • PDF

Selective Contact Hole Filling by Electroless Ni Plating (무전해Ni도금에 의한 선택적 CONTACT HOLE 충진)

  • 김영기;우찬희;박종완;이원해
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 1992.05b
    • /
    • pp.26-27
    • /
    • 1992
  • The effect of activation and electroless nickel plating conditions on contact properties were investigated for selective electroless nickel plating of Si farers in order to obtain an optimum condition of contact hole filling. According to RCA prosess, p-type si 1 icon (100) surface was cleaned out and activated. The effects of temperture, DMAB concentration, time, and stirring iwere investigated for activation of p-type Si(100) surface. The optimal activation condition obtained was 0.5M HF, 1mM PdCl$_2$, 2mM EDTA, 7$0^{\circ}C$, 90sec under ultrasonic vibration. In electroless nickel plating, the effect of temperature, DMAB concentration, pH, and plating ti me were studied. The optimal plating condition found was 0. 10M NiS0$_4$.$H_2O$, 0.lIM Citrate, pH 6.8, 6$0^{\circ}C$, 30 minutes. The contact resistence of fi]ms wascomparatively low. It took 30 minutes to obtain 1$\mu$m thick film with 8$\mu$M DMAB concentration. The film surface roughness was improved with increasing temperature and decreasing pH of the plating solution. The best quality of the film was obtained with the condition of temperature 6$0^{\circ}C$ and pH 6.8. The micro-victors hardness of film was about 600Hv and was decreased wi th increasing particle size of plating layer.

  • PDF

Comparison of Microhardness and Compressive Strength of Alkasite and Conventional Restorative Materials (Alkasite와 기존의 수복 재료의 압축강도 및 미세경도 비교)

  • Lee, Kunho;Kim, Jongsoo;Shin, Jisun;Han, Miran
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.3
    • /
    • pp.320-326
    • /
    • 2020
  • The aim of this study was to compare compressive strength and microhardness of recently introduced alkasite restorative materials with glass ionomer cement and flowable composite resin. For each material, 20 samples were prepared respectively for compressive strength and Vickers microhardness test. The compressive strength was measured with universal testing machine at crosshead speed of 1 mm/min. And microhardness was measured using Vickers Micro hardness testing machine under 500 g load and 10 seconds dwelling time at 1 hour, 1 day, 7 days, 14 days, 21 days and 35 days. The compressive strength was highest in composite resin, followed by alkasite, and glass ionomer cement. In microhardness test, composite resin, which had no change throughout experimental periods, showed highest microhardness in 1 hour, 1 day, and 7 days measurement. The glass ionomer cement showed increase in microhardness for 7 days and no difference was found with composite resin after 14 days measurement. For alkasite, maximum microhardness was measured on 14 days, but showed gradual decrease.