• 제목/요약/키워드: Micro-fans

검색결과 15건 처리시간 0.027초

축류 마이크로 홴의 전산해석 및 성능시험 (A Numerical Analysis and Experiment for Micro-Fans)

  • 조진수;변태균;박왕식;전창근
    • 대한기계학회논문집B
    • /
    • 제24권7호
    • /
    • pp.895-906
    • /
    • 2000
  • A three dimensional linear frequency-domain lifting surface panel method was used for the aerodynamic analysis of axial flow type micro-fans. As proven by the duct modeling, the tip clearance of the micro-fans tested is large enough to ignore the calculated effect of the duct system. As the numerical results and experimental data agreed well in the operating point region, the method was applicable in the parametric studies to determine the design parameters of axial flow fans. Experiments on micro-fans were carried out based on KS B 6311. The newly designed micro-fan showed improvements in both static pressure rise and volumetric flow rate compared to the existing fans at a given operating condition. No detection of surging and the smooth characteristic curve proved the improvement in performance. To reduce the fan noise in the fan design, it was necessary to make use of the frequency spectrum analysis data. Measurement of sound pressure level for micro-fans was conducted based on KS B 6361 and KS A 0705. The peak - which occurs at blade passage frequency and its higher harmonics due to the fan noise - was not detected. This justifies the design methodology of the blade.

CPU 냉각용 저소음 Micro-Cooling Fan 의 개발 (Development of Micro-Cooling Fans for Cooling of CPU)

  • 김기황;박용민;김진화;이승배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.961-966
    • /
    • 2001
  • Micro fans of randomly swept-blades were designed to provide C.P.U. in a personal computer with effective cooling in a very quiet mode. The proto--type axial micro-fans machined by a laser sintering machine were tested against manufactured products by comparing the performance and overall sound pressure level with spectral measurements in an environment suggested by ASHRAE and ANSI standards. The predicted OSPLs and directivity patterns of fans by iDesignFan software were in good agreements with measured data. The newly introduced fans of randomly swept-blades were proved to provide a very promising mode of low noise at small loading conditions.

  • PDF

Micro lens array 설계 (Design of micro lens array)

  • 홍경희
    • 한국광학회지
    • /
    • 제5권2호
    • /
    • pp.204-211
    • /
    • 1994
  • 팩시밀이나 복사기용으로 이용되는 micro lens array를 설계하였다. array 형태는 육각형배열이고 유효경은 0.160mm, 가장 가까운 이웃렌즈의 중심간 거리는 0.192mm로 하였다. 결상계의 횡배율은 1.0이다. single layer는 working distance가 10.55mm, double layer는 working distance가 7.90mm가 되었다. 각각의 성능은 ray fan을 계산하여 그 특성을 조사하였으며 서로 비교하였다.

  • PDF

Rapid Manufacturing of 3D Micro-products using UV Laser Ablation and Phase-change Filling

  • Shin Bo-Sung;Kim Jae-Gu;Chang Won-Suk;Whang Kyung-Hyun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제7권3호
    • /
    • pp.56-59
    • /
    • 2006
  • UV laser micromachining is generally used to create microstructures for micro-products through a sequence of lithography-based photo-patterning steps. However, the micromachining process is not suitable for rapid realization of complex 3D micro-products because it depends on worker experience. In addition, the cost and time required to make many masks are excessive. In this paper, a more effective and rapid micro-manufacturing process, which was developed based on laser micromachining, is proposed for fabricating micro-products directly using UV laser ablation and phase-change filling. The filling process is useful for holding the micro-products during the ablation step. The proposed rapid micro-manufacturing process was demonstrated experimentally by fabricating 3D micro-products from functional UV-sensitive polymers using 3D CAD data.

느타리재배사 정역 제어 대류팬이 공기 균일도에 미치는 영향 (Effect of Reversible Air-circulation Fans on Air Uniformity in a Cultivation Facility for Oyster Mushroom)

  • 염성현;김시환
    • 생물환경조절학회지
    • /
    • 제30권4호
    • /
    • pp.383-392
    • /
    • 2021
  • 느타리버섯은 재배사 내부환경에 크게 영향을 받으며 강제 공기순환팬에 의해 공기를 교반하여 내부환경의 균일도를 향상시키고 있다. 본 연구는 느타리버섯 일부 시범 농가에서의 대류팬 작동방법 등 이용 실태를 조사하고, FCU를 가동하지 않은 버섯의 수확이 끝날 무렵이고 폐상 직전인 7.1-10까지 10일 간 느타리 균상재배사에 상향과 하향 등 양방향으로 번갈아 바람을 토출하는 정역 제어 대류팬과 단일 방향인 상향으로만 바람을 토출하는 관행 방식의 유동팬을 설치하여 재배사 내부환경의 균일도를 평가하고자 수행하였다. 조사 농가의 대류팬 작동방법(작동시간과 멈춤시간의 조합 방법)은 대부분 5-15분 작동 후 5-30분 멈춤을 반복적으로 적용하고 있는 것으로 조사되었으며 냉방장치를 가동하지 않은 폐상 무렵의 느타리 균상재배사에 정역 제어 대류팬을 설치하여 내부 환경 균일도를 평가한 결과, 최대 기온 편차는 1.4-1.8℃, 최대 상대습도 편차는 7.8-8.7%로 나타나 최대 기온 편차 3.2-3.7℃, 최대 상대습도 편차 14.0-15.4%를 보인 관행 방식의 유동팬에 비해 내부환경 균일도가 향상된 것으로 나타났다. 20가지의 정역 제어 대류팬 작동방법 중에서는 10-15분간 상향으로 바람을 토출한 후 5-10분 간 멈추고 바람의 방향을 바꾸어 하향으로 10-15분 간 바람을 토출하는 경우가 가장 적은 기온 편차(1.4-1.5℃)를 보였으나 센서의 오차범위 수준에 있어 설정별 차이를 보인다고는 판단할 수 없었다. 향후 버섯의 호흡이 온전히 고려되고 냉방장치가 가동되는 실제 재배기간 중 정역 제어 대류팬이 공기 균일도와 느타리버섯 품질에 미치는 영향을 평가할 필요가 있을 것으로 판단되었으며 재배사 내 공기교반 정도를 확인하기 위한 유동 가시화 연구가 필요할 것으로 판단되었다.

전기 철도차량의 보조전원장치 실습용 시뮬레이터 개발 (Simulator Development for Training Auxiliary Power Supply in Electric Rolling Stock)

  • 김재문;김덕헌;김연충
    • 전기학회논문지P
    • /
    • 제54권4호
    • /
    • pp.192-197
    • /
    • 2005
  • This paper presents a development of the auxiliary power supply simulator for a electric rolling stock. An auxiliary power supplies are required for operating air conditioning units, ventilation fans, lighting and battery charging. Traditionally this function has been fulfilled by Motor-Alternator sets. In recent years, high performance of semiconductor and micro processor, availability and price have made three phase voltage source inverters as an attractive alternative to MA Sets. From the baseline model of the SIV(Static InVerter) for electric rolling stock, we designed the scale down model of the auxiliary power supply simulator consisting of an IGBT three phase voltage source inverter. The auxiliary power supply simulator can be used educatory purpose for training efficiently about operating principles of SIV.

THE STARTING CHARACTERISTICS IMPROVEMENT OF SPIM WITH ONE-CHIP MICROCONTROLLER

  • Park, Su-Kang;Choi, Nak-Il;Cho, Geum-Bae;Oh, Keum-Gon;Baek, Hyung-Lae;Lim, Yang-Su
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.321-324
    • /
    • 1998
  • A single phase induction motor (SPIM) rated in fractional horsepower is widely used in home and industrial equipment: washing machines, fans, refrigerators, etc. In this paper, authors present the experimental results of the SPIM under controlling of currents of main and auxiliary windings by using a one-chip micro stator(OMS). This new starting method is developed to replace the conventional starting device consisted with a mechanical switch and a capacitor. In mentioned method, the soft-starting of SPIM is simply implemented and higher efficiency is obtained in comparison with conventional condenser type SPIM.

  • PDF

가정용 DLP 프로젝터의 소음 저감에 관한 연구 (Study on Noise Reduction of DLP Front Home Theater Projector)

  • 장동섭;박철민;박대경
    • 한국소음진동공학회논문집
    • /
    • 제14권9호
    • /
    • pp.861-867
    • /
    • 2004
  • For the evaluation of acoustic noise of a DLP projector, vibration and sound characteristics of a DLP projector were studied. The acoustic noise of DLP projector could be classified into three categories, that is, the direct noise from a body of rotation, the air-bone noise generated from turbulence or vortex occurred during cooling process and the structural born noise produced by vibrating elements. Cooling fans and color filter wheel which rotates at 9000 rpm are main causes of acoustic noise induced in DLP projector. Since the structure of an optical module in a DLP projector can be excited by the excessive vibration of a color filter wheel, the structural design for anti-vibration should be considered. To make a reduction of overall acoustic noise, the anti-vibration design and the enclosing structure have been studied and applied to a color filter wheel.

고온환경 작업을 위한 펠티어 소자 냉각복 개발 및 쾌적성 평가 (Development of Cooling Garment for Extremely Hot Environment Using a Peltier Device and its Comfort Properties)

  • 정예리;채영진;김은애
    • 한국의류학회지
    • /
    • 제36권1호
    • /
    • pp.1-11
    • /
    • 2012
  • This paper reports on a prototype cooling garment applying a cooling module. The cooling module was composed of a Peltier device, a cold sink, a heat sink and two fans. A constant box was used to evaluate the cooling effect of the module. Two cooling modules were attached on each side of the garment. The wear trial was conducted using 10 male subjects in an environmental chamber maintained at $30{\pm}0.5^{\circ}C$, $50{\pm}5%$RH. Subjective sensations of thermal, humidity, and comfort were surveyed. Statistical package SPSS12.0 was used for the t-test and the Wilcoxon signed-rank test. The results showed that most effective cooling module decreased the temperature of the constant temperature box by $-4.9^{\circ}C$. The micro-temperature of the cooling garment with a Peltier device was lower than the control garment during the exercise. In particular, the chest skin temperature was $1.5^{\circ}C$ lower with the cooling garment than the control. The maximum temperature difference was $-2.57^{\circ}C$ on the sides of the $1^{st}$ layer. Subjective thermal sensation from wear trials of the Peltier device attached garment was lower than the control garment. Subjects felt more comfortable with the cooling garment in almost all the periods.

설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009)

  • 한화택;이대영;김서영;최종민;백용규;권영철
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.