• 제목/요약/키워드: Micro-data

검색결과 1,951건 처리시간 0.036초

Micro-hardness and Young's modulus of a thermo-mechanically processed biomedical titanium alloy

  • Mohammed, Mohsin Talib;Khan, Zahid A.;M., Geetha;Siddiquee, Arshad N.
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • 제1권3호
    • /
    • pp.117-130
    • /
    • 2014
  • This paper presents a study on the influence of different thermo-mechanical processing (TMP) parameters on some required properties such as micro-hardness and Young's modulus of a novel near ${\beta}$ alloy Ti-20.6Nb-13.6Zr-0.5V (TNZV). The TMP scheme comprises of hot working above and below ${\beta}$ phase, solutionizing treatment above and below ${\beta}$ phase coupled with different cooling rates. Factorial design of experiment is used to systematically collect data for micro-hardness and Young's modulus. Validity of assumptions related to the collected data is checked through several diagnostic tests. The analysis of variance (ANOVA) is used to determine the significance of the main and interaction effects. Finally, optimization of the TMP process parameters is also done to achieve optimum values of the micro-hardness and Young's modulus.

축류 마이크로 홴의 전산해석 및 성능시험 (A Numerical Analysis and Experiment for Micro-Fans)

  • 조진수;변태균;박왕식;전창근
    • 대한기계학회논문집B
    • /
    • 제24권7호
    • /
    • pp.895-906
    • /
    • 2000
  • A three dimensional linear frequency-domain lifting surface panel method was used for the aerodynamic analysis of axial flow type micro-fans. As proven by the duct modeling, the tip clearance of the micro-fans tested is large enough to ignore the calculated effect of the duct system. As the numerical results and experimental data agreed well in the operating point region, the method was applicable in the parametric studies to determine the design parameters of axial flow fans. Experiments on micro-fans were carried out based on KS B 6311. The newly designed micro-fan showed improvements in both static pressure rise and volumetric flow rate compared to the existing fans at a given operating condition. No detection of surging and the smooth characteristic curve proved the improvement in performance. To reduce the fan noise in the fan design, it was necessary to make use of the frequency spectrum analysis data. Measurement of sound pressure level for micro-fans was conducted based on KS B 6361 and KS A 0705. The peak - which occurs at blade passage frequency and its higher harmonics due to the fan noise - was not detected. This justifies the design methodology of the blade.

How to Explain the Contradiction of microRNA 200c Expression and Survival in Solid Tumors?: a Meta-analysis

  • Wang, Hui-Yu;Shen, Jie;Jiang, Chun-Ping;Liu, Bao-Rui
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권8호
    • /
    • pp.3687-3690
    • /
    • 2014
  • MicroRNA 200c is a microRNA 200 family member that plays an important role in regulation of the epithelial-to-mesenchymal transition (EMT). The prognostic value of microRNA 200c in solid tumors remains controversial because of inconsistent data. Here, we report a meta-analysis of the association of microRNA 200c expression and survival in patients with solid tumors. Pubmed was searched up to November 2013 for studies investigating microRNA 200c expression and overall survival (OS) in solid tumors. Hazard ratios (HRs) with 95% confidence intervals (CIs) for OS were extracted from each study. Pooled HR and CIs were calculated using the Mantel-Haenszel fixed-effects models. A total of five studies evaluating colorectal cancer, gastric cancer, ovarian cancer, pancreatic cancer and endometrial cancer were included in the analysis. Data were divided into tissue microRNA 200c expression group and serum microRNA 200c expression group. The combined HRs [95%CIs] estimated for OS were 0.62 [0.42-0.91] and 2.16 [1.32-3.52] respectively. Low expression of microRNA 200c in tumor tissue and high expression of microRNA 200c in serum are associated with worse survival in solid tumors. Further study is needed to elucidate this contradiction.

UV 레이저 어블레이션과 상변화 충진을 이용한 3차원 마이크로 부품의 쾌속 제작 (Rapid Manufacturing of 3D Micro Products by UV Laser Ablation and Phase Change Filling)

  • 신보성;김재구;장원석;황경현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.26-29
    • /
    • 2003
  • UV laser micromachining are generally used to create microstructures for micro product through a sequence of lithography-based photopatterning steps. However, the micromachining process is not suitable for the rapid realization of complex microscale 3D product because it depends on worker experiences, excessive cost and time to make many masks. In this paper, the more effective micro rapid manufacturing process, which is developed upon the base of laser micromachining. is proposed to fabricate micro products directly using UV laser ablation and phase change filling. The filling process is useful to hold the micro product during the next ablation step. The proposed micro rapid manufacturing process is also proven experimentally that enables to fabricate the 3D microscale products of UV sensitive polymer from 3D CAD data to functional micro parts.

  • PDF

마이크로 핫플레이트를 갖는 마이크로 가스센서의 열적성능에 관한 연구 (A Study on Thermal Performances of Micro Gas Sensor with Micro Hotplate)

  • 주영철;임준형;이주헌;김창교
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권5호
    • /
    • pp.278-285
    • /
    • 2006
  • A micro hotplate for micro gas sensor was fabricated by MEMS technology. In order to heat up the gas sensing material to a target temperature, a micro hotplate was built on the gas sensor. The sensing material was deposited on the heater and electrodes, and did not contact with the silicon base to minimize the heat loss to the silicon base. The electric power to heat up the gas sensor was measured. The temperature distribution of micro gas sensor was analyzed by a CFD program. The predicted electric power to heat up th sensing material showed a good agreement with the measured data. The design of micro gas sensor could be modified to increase the temperature uniformity and to decrease the electric power consumption by optimizing the layout of micro hotplate and electrodes.

스텝모우터의 미세스텝 제어에 관한 연구 (A study on the microstep control of stepping motors)

  • 김도현;최계근;이종각
    • 전기의세계
    • /
    • 제31권1호
    • /
    • pp.68-73
    • /
    • 1982
  • An accurate mathematical model of permanent magnet stepping motor is proposed. On the basis of this model, micro-stepping control is experimented. A comparison is made between the Data experimented by micro-stepping control and the data predicted by the proposed model and by Leenhouts' earlier model. The result shows that the proposed model is more accurate than the earlier model, and micro-stepping can be attained by dividing a given step electrically, without adding much complexity to the control circuit, or degrading the speed of stepping motors.

  • PDF

마이크로 ESPI 기법에 의한 면내 변형 측정 민감도 향상 (Improvement of Sensitivity to In-plane Strain/Deformation Measurement by Micro-ESPI Technique)

  • 김동일;허용학;기창두
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1442-1445
    • /
    • 2005
  • Several test methods, including micro strain/deformation measurement techniques, have been studied to more reliably measure the micro properties in micro/nano materials. Therefore, in this study, the continuous measurement of in-plane tensile strain in micro-sized specimens of thin film materials was introduced using the micro-ESPI technique. TiN and Au thin films 1 and $0.47\;\mu{m}$ thick, respectively, were deposited on the silicon wafer and fabricated into the micro-sized tensile specimens using the electromachining process. The micro-tensile loading system and micro-ESPI system were developed to measure the tensile strain during micro-tensile test. The micro-tensile stress-strain for these materials was determined using the algorithm for continuous strain measurement. Furthermore, algorithm for enhancing the sensitivity to measurement of in-plane tensile strain was suggested. According to the algorithm for enhancement of sensitivity, micro-tensile strain data between interfringe were calculated. It is shown that the algorithm for enhancement of the sensitivity suggested in this study makes the sensitivity to the in-plane tensile strain increase.

  • PDF

알루미늄 다채널 평판관내 R-22 응축에 관한 연구 (R-22 Condensation in Flat Aluminum Multi-Channel Tubes)

  • 김정오;조진표;김내현
    • 대한기계학회논문집B
    • /
    • 제24권2호
    • /
    • pp.241-250
    • /
    • 2000
  • In this study, condensation heat transfer tests were conducted in flat aluminum multi-channel tubes using R-22. Two internal geometries were tested ; one with smooth inner surface and the other with micro-fins. Data are presented for the followin~ range of variables ; vapor quality($0.1{\sim}0.9$), mass flux($200{\sim}600kg/m^2s$) and heat flux($5{\sim}15kW/m^2$). The micro-fin tube showed higher heat transfer coefficients compared with those of the smooth tube. The difference increased as the vapor quality increased. Surface tension force acting on the micro-fin surface at the high vapor quality is believed to be responsible. Different from the trends of the smooth tube, where the heat transfer coefficient increased as the mass flux increased, the heat transfer coefficient of the micro-fin tube was independent of the mass flux at high vapor quality, which implies that the surface tension effect on the fin overwhelms the vapor shear effect at the high vapor quality. Present data(except those at low mass flux and high quality) were well correlated by equivalent Reynolds number, Existing correlations overpredicted the present data at high mass flux.

Voltage Measurement Accuracy Assessment System for Distribution Equipment of Smart Distribution Network

  • Cho, Jintae;Kwon, Seong-chul;Kim, Jae-Han;Won, Jong-Nam;Cho, Seong-Soo;Kim, Juyong
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1328-1334
    • /
    • 2015
  • A new system for evaluating the voltage management errors of distribution equipment is presented in this paper. The main concept of the new system is to use real distribution live-line voltage to evaluate and correct the voltage measurement data from distribution equipment. This new approach is suitable for a new Distribution Management System (DMS) which has been developed for a distribution power system due to the connection of distributed generation growth. The data from distribution equipment that is installed at distribution lines must be accurate for the performance of the DMS. The proposed system is expected to provide a solution for voltage measurement accuracy assessment for the reliable and efficient operation of the DMS. An experimental study on actual distribution equipment verifies that this voltage measurement accuracy assessment system can assess and calibrate the voltage measurement data from distribution equipment installed at the distribution line.

Three Dimensional Architecture of Multiplexing Data Registration Integrated Circuit for Flat Panel Display

  • Tseng, Fan-Gang;Liou, Jian-Chiun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1293-1296
    • /
    • 2008
  • As Flat Panel Display become large in format, the data and gate lines turn into longer, parasitic capacitance and resistance increase, and the display signal is delayed. Three dimensional architecture of multiplexing data registration integrated circuit method is used that divides the data line into several blocks and provides the advantages of high accuracy, rapid selection, and reasonable switching speed.

  • PDF