• 제목/요약/키워드: Micro-channel Flow

검색결과 221건 처리시간 0.031초

수평미세관내 R-290의 비등열전달 특성 (Boiling Heat Transfer Characteristics of R-290 in Horizontal Minichannel)

  • 최광일;;오종택
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.68-73
    • /
    • 2006
  • The present paper deals with an experimental study of boiling heat transfer characteristics of R-290, and is focused on pressure gradient and heat transfer coefficient of the refrigerant flow inside horizontal smooth minichannel with inner diameter of 3.0 mm and length of 2000 mm. The direct heating method applied for supplying heat to the refrigerant where the test tube was uniformly heated by electric current which was applied to the tube wall. The experiments were conducted with R-290 with purity of 99.99% at saturation temperature of 0 to $10^{\circ}C$. The range of mass flux is $50{\sim}250kg/m^2s$ and heat flux is $5{\sim}20kW/m^2$. The heat transfer coefficients of R-290 increases with increasing mass flux and saturation temperature, wherein the effect of mass flux is higher than that of the saturation temperature, whereas the heat flux has a low effect on increasing heat transfer coefficient. The significant effect of mass flux on heat transfer coefficient is shown at high quality, the effect of heat flux on heat transfer coefficient at low quality shows a domination of nucleate boiling contribution. The heat transfer coefficient of the experimental result was compared with six existing heat transfer coefficient correlation. Zang et al.'s correlation(2004) gave the best prediction of heat transfer coefficient.

  • PDF

Microfluidics를 이용한 화장품 에멀젼 캡슐레이션에 대한 연구 (A Study on the Encapsulation of Cosmetic Emulsion Using Microfluidics)

  • 정남균;진홍종
    • 한국산학기술학회논문지
    • /
    • 제22권1호
    • /
    • pp.81-86
    • /
    • 2021
  • 화장품 산업은 정밀화학분야로 기술집약적인 산업이며 세계적으로 지속적인 성장률을 보이고 있다. 이러한 화장품 산업에서 시장 점유율을 높이기 위해 과거에는 기능적 측면이 주로 강조가 되어 왔으나, 최근에는 국내외적으로 화장품의 우수한 성능과 더불어 시각적 효과로 소비자의 관심을 유도하려는 노력이 고조되고 있다. 이에 따라 화장품 제조업체에서는 화장품 에멀젼을 캡슐화하고 에멀젼 캡슐의 형태, 색상 및 질감 등을 다양하게 변형시킬 수 있는 기술을 다방면으로 시도하고 있는 상황이다. 에멀젼을 캡슐화하는 기본 방식은 에멀젼 저장소에 에멀젼을 채워 넣고 노즐을 통해 에멀젼을 낙하시키는 방법으로 업체에서 가장 쉽게 이용할 수 있다. 그러나, 에멀젼을 캡슐레이션하는 기존 방식은 캡슐의 사이즈를 줄이는 데 한계가 있다. 본 연구에서는 이러한 기존 방식의 한계를 이론 및 수치해석방법으로 고찰하였으며, 이러한 방식의 문제를 해결하기 위한 대안책으로 미세유체역학(Microfluidics)을 적용하기 위하여 마이크로 채널 내에서 발생하는 에멀젼 캡슐레이션 현상을 연구하였다.

자유수면 와류에서 마이크로 소수력의 성능에 풀리가 미치는 영향 분석 (Effect Analysis of Pulley on Performance of Micro Hydropower in Free Surface Vortex)

  • 최인호;김종우;정기수
    • 한국습지학회지
    • /
    • 제23권3호
    • /
    • pp.234-241
    • /
    • 2021
  • 본 논문은 자유수면을 갖는 와류수차의 성능에 풀리의 영향을 이해하는 것이다. 실험은 개수로 유입구 유량 0.0069 ~ 0.0077 m3/s 범위에서 물리적 인자(와류높이, 유속, 유효낙차 등)에 따른 수차의 회전수, 전압 및 전류를 측정해 분석하였다. 실험결과에 따르면 와류수차의 전압, 전류 및 회전수는 블레이드 형태와 상관없이 풀리비가 증가할 경우 감소하였다. 직선형 블레이드와 비틀린 블레이드의 효율은 풀리비 0.45 지점에서 52 %인 반면 소형 비틀린 블레이드의 효율은 풀리비 0.21 지점에서 54 %이다. 와류수차의 최대 발전량은 풀리비 0.5 지점 내에서 발생했다. 와류수차의 효율은 풀리비에 따라 0.2 ~ 58 % 범위에서 관찰되었다.

설비공학 분야의 최근 연구 동향 : 2009년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2009)

  • 한화택;이대영;김서영;최종민;백용규;권영철
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.492-507
    • /
    • 2010
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2009. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery and piping, and new and renewable energy. Various topics were covered in the field of general thermal and fluid flow such as an expander, a capillary tube, the flow of micro-channel water blocks, the friction and anti-wear characteristics of nano oils with mixtures of refrigerant oils, etc. Research issues mainly focused on the design of micro-pumps and fans, the heat resistance reliability of axial smoke exhaust fans, and hood systems in the field of fluid machinery and piping. Studies on ground water sources were executed concerning two well type geothermal heat pumps and multi-heat pumps in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included the heat transfer in thermoelectric cooling systems, refrigerants, evaporators, dryers, desiccant rotors. In the area of industrial heat exchangers, researches on high temperature ceramic heat exchangers, plate heat exchangers, frosting on fins of heat exchangers were performed. (3) In the field of refrigeration, papers were presented on alternative refrigerants, system improvements, and the utilization of various energy sources. Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and $CO_2$ were studied. Efforts to improve the performance of refrigeration systems were made applying various ideas of suction line heat exchangers, subcooling bypass lines and gas injection systems. Studies on heat pump systems using unutilized energy sources such as river water, underground water, and waste heat were also reported. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. In the area of cogeneration systems, papers on energy and economic analysis, LCC analysis and cost estimating were reported. Studies on ventilation and heat recovery systems introduced the effect on fire and smoke control, and energy reduction. Papers on district cooling and heating systems dealt with design capacity evaluation, application plan and field application. Also, the maintenance and management of building service equipments were presented for HVAC systems. (5) In the field of architectural environment, various studies were carried to improve indoor air quality and to analyze the heat load characteristics of buildings by energy simulation. These studies helped to understand the physics related to building load characteristics and to improve the quality of architectural environment where human beings reside in.

몰드형 건식 계기용 변압기 제작을 위한 수지 충진 해석 연구 (Numerical Analysis of Resin Filling Process for a Molded Dry-type Potential Transformer)

  • 김무선;장동욱;김승모
    • 한국산학기술학회논문지
    • /
    • 제17권12호
    • /
    • pp.511-517
    • /
    • 2016
  • 철도 차량에 쓰이는 기존 유입식 형태의 계기용 변압기는 장치 내부에 절연유가 충진 된 형태이므로, 차량 운행 중에 내부 압력이 상승할 수 있는 가능성이 있으며. 그에 따른 폭발위험성이 존재한다. 따라서 폭발 방지를 위해 몰드형 건식 계기용 변압기를 개발 중에 있다. 몰드형 건식 계기용 변압기 개발시 주의 하여야 할 점은 몰드를 구성하는 절연용 에폭시 수지를 주입할 때 권선 코일이 감겨진 코어 주변에 기공이 없어야 한다는 것이다. 이는 몰드 내부의 기공에서 스파크 등의 발생 위험이 있기 때문이다. 몰드 내의 기공 발생 요인으로는, 수지 내에 미세 기공(micro void)이 잔재되어 있는 경우와, 성형 중 함침 구조물의 형태에 따라서 대형 기공(macro void)이 발생할 수 있는 점 등이다. 현재 개발 중인 코어는 변압기 성능 향상을 위해 중공(cavity)이 존재하는 형태이며 점도가 높은 에폭시 주입시 중공 내부에 대형 기공이 갇힐 위험이 있다. 따라서 이번 연구에서는, 몰드 내부에 발생할 수 있는 대형 기공의 형성 과정을 이해하고, 기공 형성 요인을 제거할 수 있는 방안으로, 개선된 성형 조건 적용시 기공 형성 결과를 확인하기 위해, 몰드 충진 과정을 VOF기법을 적용한 자유 표면 유동의 수치해석을 통하여 확인하였다.

난방운전 조건하에서 $CO_2$ 열펌프용 내부 열교환기의 열전달 특성에 대한 연구 (Study on Heat Transfer Characteristics of Internal Heat Exchanger for $CO_2$ Heat Pump under Heating Operating Condition)

  • 김대훈;이상재;최준영;이재헌;권영철
    • 에너지공학
    • /
    • 제17권2호
    • /
    • pp.116-123
    • /
    • 2008
  • 본 연구에서는 $CO_2$ 열펌프에 사용되는 내부 열교환기를 난방조건에서 운전할 경우, 실험 및 수치적 방법으로 열전달량, 효율, 압력강하 등을 관찰하였다. 4가지 종류의 내부 열교환기를 사용하였다. 수치 해석은 단면분할법과 하디크로스 방법을 이용하여 유량, 길이, 운전조건, 내부 열교환기 종류에 따른 영향을 분석하고 실험을 통해 확인하였다. 유량이 증가함에 따라 열전달량이 약 25% 향상되었다. 마이크로 채널이 동심관에 비해 열전달량이 약 100% 크게 나타났다. 길이가 증가함에 따라 열전달 증가율은 감소하였다. 압력강하는 고압측에 비해 저압측이 크게 나타났으며, 동심관에 비해 마이크로 채널이 약 100% 크게 나타났다. 고온입구조건이 증가할수록, 저온입구조건이 감소할수록 열전달량은 약 3% 증가하였다. $CO_2$의 열전달 계산의 정확성을 위해 $CO_2$의 특성과 관형상을 고려할 수 있는 열전달 상관식의 개발이 필요하다.

공기조화, 냉동 분야의 최근 연구 동향 -2000년 및 2001년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research -A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2000 and 2001-)

  • 강신형;한화택;조금남;이승복;조형희;김민수
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1102-1139
    • /
    • 2002
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2000 and 2001 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD technologies were widely applied for developing facilities and their systems. (2) Most of papers related with heat transfer analysis and heat exchanger shows dealt with convection, evaporation, and channel flow for the design application of heat exchanger. The numerical heat transfer simulation studies have been peformed and reported to show heat transfer characteristics. Experimental as well as numerical studies on heat exchanger were reported, while not many papers are available for the system analysis including heat exchanger. (3) A review of the recent studies on heat pump system shows that performance analysis and control of heat pump have been peformed by various simulations and experiments. The research papers on multi-type heat pump system increased significantly. The studies on heat pipe have been examined experimently for change of working characteristics and strut lure. Research on the phase change has been carried out steadily and operation strategies of encapsulated ice storage tank are reported experimentally in several papers. (4) A review of recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. Evaporation and condensation heat transfer characteristics are investigated for tube shapes and new alternative refrigerants. Studies on components of refrigeration/air conditioning system are carried to examine efficiency for various compressors and performance of new expansion devices. In addition to thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out, however research works on two-phase flow seemed to be insufficient. (5) A review of the recent studies on absorption cooling system indicates that heat and mass transfer phenomena have been investigated to improve absorber performance. Various experimental data have been presented and several simulation models have been proposed. A review of the recent studies on duct and ventilation shows that ventilation indices have been proposed to quantify the ventilation performance in buildings and tunnels. Main efforts have been focused on the applications of ventilation effectiveness in practice, either numerically using computational fluid dynamics or experimentally using tracer gas techniques. (6) Based on a review of recent studies on indoor thermal environment and building service systems, research issues have mainly focused on many innovative ideas such as underfloor air-conditioning system, personal environmental modules, radiant floor cooling and etc. Also, the new approaches for minimizing energy consumption as well as improving indoor environmental conditions through predictive control of HVAC systems, various activities of building energy management and cost-benefit analysis for economic evaluation were highlighted.

소듐과 이산화탄소 반응에 의한 소듐유로막힘 및 재료손상 현상 연구 (Investigation of Plugging and Wastage of Narrow Sodium Channels by Sodium and Carbon Dioxide Interaction)

  • 박선희;민재홍;이태호;위명환
    • Korean Chemical Engineering Research
    • /
    • 제54권6호
    • /
    • pp.863-870
    • /
    • 2016
  • 본 논문의 목적은 소듐냉각고속로(sodium cooled fast reactor, SFR)와 초임계 $CO_2$ Brayton cycle의 연계 시, 원자로 열수송 계통과 동력변환 계통의 압력 경계를 형성하는 회로인쇄형 열교환기의 경계면에 균열이 발생해 고압(약 200 bar)의 $CO_2$가 상압 수준의 액체소듐유로 측에 유입되었을 때의 물리/화학적 현상을 파악하여 열교환기 설계에 활용 가능한 실험 자료를 생산하는 것이다. 열교환기의 소듐-$CO_2$ 경계면 균열 현상은 경계면의 균열 크기에 따라 미세 균열에 의한 소듐유로막힘(plugging) 현상과 상대적으로 큰 균열에 의한 열교환기 재료손상(wastage) 현상으로 나뉜다. Plugging 실험결과, 소듐유로 직경이 3mm일 때 $CO_2$ 주입 즉시 소듐 흐름이 정지한 반면 소듐유로 직경이 5 mm일 때는 유량이 감소되기 시작하는 시점은 3 mm의 경우와 유사하게 $CO_2$ 주입 즉시 나타났지만 소듐의 흐름이 완전히 정지할 때까지는 상대적으로 오랜 시간이 소요되었다. 이러한 실험결과는 실제 열교환기의 소듐-$CO_2$ 경계면에서 미세균열이 발생했을 때, 소듐유로 직경이 3 mm로 좁을 경우 균열 발생과 동시에 해당 소듐유로가 반응생성물에 의해 막혀 해당 유로 외의 유로들로 지속적인 열교환기 운전이 가능하지만, 소듐유로의 직경이 5 mm로 넓어질 경우 소듐유로가 고체생성물에 의해 즉시 막히지 않고 생성물이 소듐유로를 따라 계통 내부를 이동하다 일정 농도 이상이 되어야 소듐유로를 막게 할 것으로 예상할 수 있는 결과이다. Wastage 실험결과, 열교환의 재질(STS316, Inconel600, G91 합금강), 운전온도($400{\sim}500^{\circ}C$), 노즐직경(0.2~0.8 mm), 시편-노즐 거리(2~6 mm)와 무관하게 고압(약 200~250 bar)의 $CO_2$ 분사에 의한 시편의 물리적 손상(erosion) 현상은 발생하지 않았다. 노즐에서의 분사되는 $CO_2$의 분사속도는 마하 0.4~0.7인 것으로 확인되었다. 본 연구의 실험결과는 열교환기 파손 대처 설계에 배경 실험 자료로 활용될 것으로 기대된다.

공기조화, 냉동 분야의 최근 연구 동향 - 1998년 1999년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research - A Review of papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 1998 and 1999 -)

  • 이재헌;김광우;김병주;이재효;김우승;조형희;김민수
    • 설비공학논문집
    • /
    • 제12권12호
    • /
    • pp.1098-1125
    • /
    • 2000
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 1998 and 1999 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. 1) A review of the recent studies on fluid flow, turbomachinery and pipe-network shows that many experimental investigations are conducted in applications of impingement jets. Researches on turbulent flows, pipe flows, pipe-networks are focused on analyses of practical systems and prediction of system performance. The results of noise reduction in the turbomachinery are also reported. 2) A review of the recent studies on heat transfer analysis and heat exchanger shows that there were many papers on the channel flow with the application to the design of heat exchanger in the heat transfer analysis. Various experimental and numerical papers on heat exchanger were also published, however, there were few papers available for the analysis of whole system including heat exchanger. 3) A review of the recent studies on heat pump system have focused on the multi-type system and the heat pump cycle to utilize treated sewage as the heat source. The defrosting and the frosting behaviors in the fin-tube heat exchanger is experimentally examined by several authors. Several papers on the ice storage cooling system are presented to show the dynamic simulation program and optimal operation conditions. The study on the micro heat pipes for the cooling of high power electronic components is carried out to examine the characteristics of heat and mass transfer processed. In addition to these, new type of separate thermosyphon is studied experimentally. 4) The recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. New systems operating with natural refrigerants are drawing lots of attention. In addition to these, evaporation and condensation heat transfer characteristics of traditional and new refrigerants are investigated for plain tubes and also for microfin tubes. Capillary tubes and orifice are main topics of research as expansion devices and studies on thermophysical properties of new refrigerants and refrigerant/oil mixtures are widely carried out. 5) A review of the recent studies on absorption cooling system shows that numerous experimental and analytical studies on the improvement of absorber performance have been presented. Dynamic analysis of compressor have been performed to understand its vibration characteristics. However research works on tow-phase flow and heat transfer, which could be encountered in the refrigeration system and various phase-change heat exchanger, were seemed to be insufficient. 6) A review of recent studies on duct system shows that the methods for circuit analysis, and flow balancing have been presented. Researches on ventilation are focused on the measurement of ventilation efficiency, and variation of ventilation efficiency with ventilation methods by numerous experimental and numerical studies. Furthermore, many studies have been conducted in real building in order to estimate indoor thermal environments. Many research works to get some information for cooling tower design have been performed but are insufficient. 7) A review on the recent studies on architectural thermal environment and building mechanical systems design shows that thermal comfort analysis is sitting environment, thermal performance analysis of Korean traditional building structures., and evaluation of building environmental load have been performed. However research works to improve the performance of mechanical system design and construction technology were seemed to be insufficient.

  • PDF

설비공학회 분야의 최근 연구 동향 : 2015년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2015)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제28권6호
    • /
    • pp.256-268
    • /
    • 2016
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2015. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering were carried out in the areas of flow, heat and mass transfer, cooling and heating, and air-conditioning, the renewable energy system and the flow inside building rooms. Research issues dealing with air-conditioning machines and fire and exhausting smoke were reduced. CFD seems to be spreading to more research areas. (2) Research works on heat transfer area were carried out in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the economic analysis of GHG emission, micro channel heat exchanger, effect of rib angle on thermal performance, the airside performance of fin-and-tube heat exchangers, theoretical analysis of a rotary heat exchanger, heat exchanger in a cryogenic environment, the performance of a cross-flow-type, indirect evaporative cooler made of paper/plastic film. In the area of pool boiling and condensing, the bubble jet loop heat pipe was studied. In the area of industrial heat exchangers, researches were performed on fin-tube heat exchanger, KSTAR PFC and vacuum vessel at baking phase, the performance of small-sized dehumidification rotor, design of gas-injection port of an asymmetric scroll compressor, effect of slot discharge-angle change on exhaust efficiency of range hood system with air curtain. (3) In the field of refrigeration, various studies were carried in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, a cold-climate heat pump system, $CO_2$ cascade systems, ejector cycles and a PCM-based continuous heating system were investigated. In the alternative refrigeration/energy system category, a polymer adsorption heat pump, an alcohol absorption heat pump and a desiccant-based hybrid refrigeration system were investigated. In the system control category, turbo-refrigerator capacity controls and an absorption chiller fault diagnostics were investigated. (4) In building mechanical system research fields, eighteen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the user and location awareness technology applied dimming lighting control system, the lighting performance evaluation for light-shelves, the improvement evaluation of air quality through analysis of ventilation efficiency and the evaluation of airtightness of sliding and LS window systems. The subjects of building energy were worked on the energy saving estimation of existing buildings, the developing model to predict heating energy usage in domestic city area and the performance evaluation of cooling applied with economizer control. The studies were also performed related to the experimental measurement of weight variation and thermal conductivity in polyurethane foam, the development of flame spread prevention system for sandwich panels, the utilization of heat from waste-incineration facility in large-scale horticultural facilities.