• 제목/요약/키워드: Micro-Fin

검색결과 80건 처리시간 0.034초

마이크로 휜 증발관내 냉매 R-290의 열전달 특성에 미치는 냉동유의 영향 (Influence of Refrigeration Oil on Evaporation Heat Transfer Characteristics of R-290 Inside Micro Fin Tube)

  • 박철민;안영태;이욱현;김정훈;김종수
    • 대한기계학회논문집B
    • /
    • 제24권7호
    • /
    • pp.938-944
    • /
    • 2000
  • Recently, micro fin tube is widely used to heat exchanger for high performance. And, as the alternative refrigerants for R-22, hydrocarbons such as R-290, R-600 and R-600a are very promising because of their low GWP and ODP. Thus, R-290 was used as working fluid in this study. Most design of heat exchanger had been based on heat transfer characteristics of pure refrigerant although refrigerant oil exists in the refrigeration cycles. So, the influence of oil on heat transfer characteristics have to be considered for investigating exact evaporation heat transfer characteristics. But, this is an unresolved problem of refrigeration heat transfer. Therefore the influence of the refrigeration oil to the evaporation heat transfer characteristics of R-290 were conducted in a horizontal micro tin tube. The mineral oil was used as refrigeration oil. The experimental apparatus consisted of a basic refrigeration cycle and a system for oil concentration measurement. Test conditions are as the follows; evaporation temperature $5^{\circ}C$, mass velocity 100 $kg/m^2s$, heat flux 10 $kW/m^2$, oil concentration 0, 1.3, 3.3, 5.7 wt.%, and quality $0.07{\sim}1.0$. When refrigeration oil was entered, oil foaming was observed at the low quality region. And, very small bubbles were observed as quality was increased. Pressure drop and heat transfer coefficient increased as the concentration of refrigeration oil increased to 5 wt.%.. The performance index of heat exchanger was the highest near 3.3 wt.%.

마이크로 핀 표면 핵비등에서의 기포거동에 대한 수치적 연구 (Numerical Study of Bubble Motion During Nucleate Boiling on a Micro-Finned Surface)

  • 이우림;손기헌
    • 대한기계학회논문집B
    • /
    • 제35권10호
    • /
    • pp.1089-1095
    • /
    • 2011
  • 열전달 향상을 위한 방법으로 많이 사용되고 있는 마이크로 핀을 포함한 표면 위에서의 핵비등을 액상과 기상에서 질량 및 운동량, 에너지에 대한 지배 방정식을 풀어 수치해석을 수행하였다. 핵비등에서의 기포거동을 계산하기 위해 sharp-interface 레벨셋(level-set) 방법을 상변화 효과와 핀과 캐비티와 같은 잠긴 고체에서의 점착 조건 및 접촉각, 마이크로 액체층에서의 증발 열유속을 포함하도록 수정하였다. 핀과 캐비티를 포함한 표면에서의 기포 생성, 성장, 이탈에 대한 해석을 통하여 핀-캐비티 배열, 핀-핀 간격이 핵비등에서의 기포거동에 중요한 역할을 하는 것을 확인하였다.

자동차용 에어컨 응축기의 설계기술 개발 (Development of design technique for automotive condenser)

  • 조영두;한창섭;유성연
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.10-17
    • /
    • 1999
  • The present work presents condensation heat transfer and pressure drop data for the flow of R-12 in flat extruded aluminum tubes with small hydraulic diameters. The tube outside dimensions are $18mm(width){\times}1.7mm(height)$. Three types of internal geometry with the same outside dimensions are tested : sample 1 (7 tube holes), sample 2 (13 tube holes) and sample 3 (7 tube holes, micro-fin). The overall heat transfer coefficient is obtained for air-to-refrigerant heat transfer, and the Wilson plot method is used to determine the heat transfer coefficient for refrigerant flow. The sample 2 and sample 3 show significantly higher performance than sample 1. The heat transfer rates for the sample 2 and sample 3 are 9% and 12% higher, respectively, than sample 1. The friction factors for the sample 2 and sample 3 are 11.9% and 2.4% higher, respectively, than sample 1.

  • PDF

원형 단면관 내 미세 휜의 형상 변화에 따른 열.유동 특성 및 최적 형상 개발에 관한 수치 해석 (Numerical Investigation of Thermal Characteristics and Geometrical Optimization in circular tubes with micro fins)

  • 한동혁;이규정
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1113-1118
    • /
    • 2006
  • A numerical investigation of single phase heat and flow characteristics in circular tubes with a single set of spiral micro fins was performed with varying geometrical parameters like fin height, spiral angle, and number of fins. The properties of $40^{\circ}C$ water was used as a working fluid to simulate a condenser and the RNG $k-{\epsilon}$ turbulence model was adopted. Calculation results were obtained in fully developed turbulent flow with constant surface heat flux boundary condition. Relative terms were introduced to investigate the substitution effect of conventional smooth tubes. The dimensionless terms were the heat transfer enhancement factor, the pressure drop penalty factor, and the efficiency index. Additionally, a numerical optimization was carried out to maximize thermal performance with the concept of the robust design. A statistical analysis showed that fin height interacts with number of fins and spiral angle.

  • PDF

500W 급 마이크로 가스터빈을 위한 파형 휜을 가지는 리큐퍼레이터의 열성능 비교 (Comparison of the Thermal Performance of Recuperators with Corrugated Fins for a 500W Class Micro Gas Turbine Generator)

  • 도규형;김태훈;한용식;최병일;김명배
    • 한국군사과학기술학회지
    • /
    • 제16권6호
    • /
    • pp.847-856
    • /
    • 2013
  • In this study, thermal performance of recuperators with plain and offset strip fins is investigated to enhance the thermal efficiency of a micro gas turbine. Thermal cycle analysis is conducted to determine major design parameters of a single-pass counterflow recuperator. In order to evaluate the performance of the recuperator, the effectiveness and the pressure drop in the recuperators are chosen as the objective function and the design constraint, respectively. The optimized geometries for internal structure of the recuperators with plain and offset strip fins are obtained with varying the fin spacing and height. From the result, the recuperator with offset strip fins has better thermal performance when the fin spacing, s, is smaller than 1.45mm and the thermal performance of the recuperator with plain rectangular fins is higher than that with offset strip fins in the region of $s{\geq}1.45mm$. In addition, it is found that the entrance region effect and the longitudinal wall heat conduction effect should be taken into account for accurately predicting the thermal performance of the recuperators with both plain and offset strip fins.

강제대류 및 핵비등영역에 있어서 마이크로 휜 형상이 분무냉각 열전달에 미치는 영향 (Effects of Micro-fin Structure on Spray Cooling Heat Transfer in Forced Convection and Nucleate Boiling Region)

  • 김영찬
    • 대한기계학회논문집B
    • /
    • 제34권11호
    • /
    • pp.983-990
    • /
    • 2010
  • 본 연구에서는 냉각면의 표면온도가 비교적 낮은 강제대류 및 핵비등영역에서 다양한 종류의 마이크로 휜이 가공된 냉각면의 분무냉각 열전달에 대해 실험적으로 연구하였다. 실험결과로부터 냉각면 표면에 가공된 마이크로 휜은 분무냉각 열전달을 촉진시키며, 냉각휜의 크기와 종류에 상관없이 분무유량이 증가할수록 분무냉각 열전달도 큰 폭으로 증가하고 있음을 알 수 있었다. 또한 희박한 분무영역에서는 냉각면에 가공된 휜의 크기와 형상이 분무냉각 열전달에 큰 영향을 미치고 있으나, 분무유량이 증가할수록 이러한 경향은 점차 약해져 본 실험에서 가장 높은 분무유량조건에서는 편평한 냉각면을 제외한 모든 냉각면의 열유속이 거의 동일하게 나타나고 있음을 알 수 있었다.

마이크로 Pin Fin 화학반응기에서 수소화붕소나트륨 수용액의 압력강하 및 탈수소 화학반응 연구 (Pressure Drop and Catalytic Dehydrogenation of NaBH4 Solution Across Pin Fin Structures in a Microchannel Reactor)

  • 정기문;최석현;이희준
    • 대한기계학회논문집B
    • /
    • 제41권6호
    • /
    • pp.381-387
    • /
    • 2017
  • 수소화붕소나트륨은 안정적으로 수소가 저장된 물질이며, 촉매반응으로 수소를 용이하게 분리할 수 있다. 본 연구에서는 탈수소 반응률을 높이기 위해 비표면적이 큰 마이크로 pin fin 화학반응기를 제작하여 수소화붕소나트륨 수용액의 압력강하 및 탈수소 화학반응 실험을 수행하였다. 나노공정을 이용하여 실리콘웨이퍼에 높이 $300{\mu}m$, 직경 $50{\mu}m$의 pin fin을 축간격 1.3, 횡간격 1.5으로 엇갈림 배열하였다. 수소화붕소나트륨 수용액은 5~20 wt.% 농도로 Re수 1~60으로 공급되었으며, 초고속카메라를 이용하여 탈수소반응 유동양상을 관찰하였다. 실험 결과 마이크로 pin fin 화학반응기는 동일 수력학적직경을 가지는 직관 마이크로채널 화학반응기보다 화학반응 성능이 2.45배 우수한 반면, 압력강하는 1.5배 증가하였다.

비공비 혼합냉매 R-410A를 적용한 납작한 알루미늄 마이크로 멀티 튜브에서의 마찰손실에 관한 연구 (A study on the friction head loss in flat aluminum micro multi tubes with nonazeotropic refrigerant mixtures R-410A)

  • 이정근;민경호
    • Design & Manufacturing
    • /
    • 제13권2호
    • /
    • pp.37-43
    • /
    • 2019
  • This study conducted a research as to condensation heat transfer friction loss headby using three types of flat micro multi-channel tubes with different processing of micro-fin and number of channels inside the pipes and different sizes of appearances. In addition, identical studies were conducted by using smoothing circular tubes with 5mm external diameter to study heat enhancement factor and pressure drop penalty factor. 1) The friction head loss showed an increase as the vapor quality and mass flux increased. In case of saturation temperature, it shows an increase as it gets lower. These factors are the reason occurring as the lower the saturation temperature is, the higher the density of refrigerant vapor gets. The influence of heat flux is similar as the dryness is low, but as it gets higher, it lowers in heat flux, and as the high temperature of high heat flux, it is a factor that occurs as the density gets lower. 2) RMS error of the in case of friction head loss, it showed to be predicted as 0.45~0.67 by Chisholm, Friedel, Lockhart and Martinelli. 3) As forfriction head loss penalty factor, the smaller the aspect ratio is, the larger the penalty factor gets, and as for the effect of micro-fin, the penalty factor increased because it decreases to the gas fluid the way groove for the refrigerant's flow.

Control of Delta-Wing Vortex by Micro-Fin-Type Leading-Edge Flap

  • Sohn, Myong-Hwan;Chung, Hyoung-Seog;Cho, Dong-Hyun
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제7권2호
    • /
    • pp.128-136
    • /
    • 2006
  • The present study examined the effects of micro leading-edge flaps on the vortex characteristic changes of a double-delta wing through pressure measurements of the wing upper surface and PIV measurements of the wing-leeward flow region. The experimental data were collected and analyzed while changing the deflection angle of the leading-edge flaps to investigate the feasibility of using micro leading-edge flaps as flow control devices. The test results revealed that the leading edge modification could greatly alter the vortex flow pattern and the wing surface pressure of the delta wing, which suggested that the leading-edge flaps could be used as an effective device for the control of delta-wing vortex flow.

마이크로핀 관의 기하학적 형상면화에 대한 열전달 특성(II) -증발 열전달- (Heat transfer with geometric shape of micro-fin tubes (II) -Evaporating heat transfer-)

  • 곽경민;장재식;배철호;정모
    • 설비공학논문집
    • /
    • 제11권6호
    • /
    • pp.789-798
    • /
    • 1999
  • The evaporating heat transfer experiments with refrigerant HCFC 22 are performed for performance evaluation using 4 and 6 kinds of microfin tubes with outer diameter of 9.52mm and 7.0mm, respectively. Used microfin tubes have different shape and number of fins with each other, The experimental results are represented with effects of quality, mass flux and EPR. The evaporating heat transfer characteristics are represented by the existence of not only heat transfer area and turbulence promotion effect but also additional other enhancement mechanism, which are the overflow of the refrigerant over the microfin and microfin arrangement. Microfin tubes having a shape which can give much overflow over the microfin show large evaporating heat transfer coefficients. The effect of refrigerant overflow is much severe in evaporation than condensation. The effect of microfin arrangement is related to overflow effect of the refrigerant over the microfin.

  • PDF