• Title/Summary/Keyword: Micro-CHP

Search Result 19, Processing Time 0.02 seconds

The Operation of SRM through mathematical equations from the maximum torque (최대 토크 해석 방정식에 의한 SRM의 구동)

  • 서종윤
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.725-728
    • /
    • 2000
  • This paper presents the switching angle and voltage for maximizing torque of 4-phase 6-poles SRM. The switching angle and voltages was determined through the approximated analysis and computer simulation by using SIMULINK according to the speed and torque required by load but we used new analytic equation from maximum torque characteristic And then one-chp micro-controller controls the switching angle and voltage of an asymmetrical inverter in the SRM driver. Also we expects that this method reduce micro-controller load and realize approximated real time control

  • PDF

Economic Evaluation of Building Micro-Grid Including Geothermal Energy System in Hospital Buildings (지열시스템이 포함된 빌딩마이크로그리드 시스템의 에너지성능평가 및 경제성분석)

  • Kim, Byoung-Soo;Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.273-277
    • /
    • 2009
  • This paper presents a basic energy performance data of micro gas turbine, Renewable Energy(BIPV and Solar Collector System, geothermal system) and a hybrid energy system(geothermal system and microturbine) installed in Hospital Building. The efficiency of solar collector and BIPV system was 30%, 10% individually, and lower than micro gas turbines. Micro gas turbines are small gas turbines that bum gaseous and liquid fuels to produce a high-energy exhaust gas and to generate the electrical power. Recently, the size range for micro gas turbines is form 30 to 500kW and power-only generation or in combined heat and power(CHP) systems. Finally, in energy performance aspect, Micro gas turbine system and hybrid energy system were high-efficiency system in hospital building. Hybrid energy system also give us a powerful alternative energy system economically.

  • PDF

Price-Based Unit Commitment for Micro-CHP in Korea (한국 전력시장 환경을 고려한 소형열병합발전기의 요금 기반 기동정지계획)

  • Joo, Jhi-Young;Ahn, Sang-Ho;Kim, Dong-Hyeon;Park, Geun-Pyo;Yoon, Yong-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.347-348
    • /
    • 2006
  • 발전기의 기동정지계획(unit commitment)에 있어서 전통적인 방식은 발전기를 기동/정지하는데 드는 비용(cost)을 기반으로 결정해 왔다. 그러나 전력시장의 변화에 따라 반전기의 기동정지계획에 전력 요금(price)의 중요성이 인식되면서 요금에 기반한 기동정지계획에 대한 연구들이 진행되고 있다. (1) 본 논문에서는 이러한 요금 기반 기동정지계획을 한국의 전력시장 환경에서 소형열병합발전기(micro-CHP(combined heat and power))에 적용해 본다. 한국의 전력시장에서 주택에 사용되는 전력 요금에 대해서는 누진제가 적용된다. 그러므로 븐 논문에서는 아파트에 설치된 소형열병합발전기의 요금 기반 기동정지계획의 시뮬레이션 결과를 분석함으로써 전력 요금의 누진제가 기동정지계획에 어떠한 영향을 주는지에 대해서 논하고자 한다.

  • PDF

Operating Characteristics of a Scroll Expander Used in Organic Rankine Cycle (유기랭킨사이클 적용 스크롤 팽창기 성능 특성 연구)

  • Shin, Dong-Gil;Kim, Young-Min;Kim, Chang-Gi
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.776-781
    • /
    • 2011
  • The rapid increases in global energy demand and global warming need renewable energy sources such as solar thermal energy, biomass energy and waste heat. A ORC-based micro-CHP system(< 10 kWe) is one of the effective means to use renewable energy and solve energy problems because of its compactness, flexibilities and lower cost compared to other systems. The most important core components of the ORC is the expander which has a strong effect on the cycle efficiency. In the range of power output from 1 to 10 kW, the scroll expander is a good choice due to its performance and reliability. In this study, we have carried out an experimental study on an ORC equipped with oil-free scroll expander working with refrigerant R134a. We have measured power output and thermal efficiencies of the ORC and analyzed correlation between volumetric efficiencies of the expander and thermal efficiencies of the ORC.

Structural Analysis of High-Density Mobile Micro-Connector (초소형 고집적 모바일 커넥터부품 구조해석)

  • Jeon, Yong-Jun;Shin, Kwang-Ho;Heo, Young-Moo
    • Design & Manufacturing
    • /
    • v.9 no.2
    • /
    • pp.1-5
    • /
    • 2015
  • Recently, as small-sized display products such as mobile phones and digital cameras have become lighter and smaller, the size of electric signal delivery part, connector for the mobile display products, also, needs to become smaller, so high-density integration like shortening the distance between signal delivery media, conductors is necessary. With the micro and high-density integration of the connector, it is necessary to maintain contact to a certain degree for keeping intensity and delivering electric signal smoothly to prevent a defect with a specific impact. Accordingly, this study carried out a structural analysis according to the operating mechanisms of 0.16CHP Class Bottom Contact FPC Connector and 0.24CHP Class BTB Connector mostly used in small-sized mobile display products such as mobile phones and digital cameras. As a result of the analysis, both connectors had lower than 997MPa, yield strength of connector material C5240-XSH, so it is judged that permanent plastic deformation would not occur, and that a contact force between the connector and FPC film occurs to a certain degree, so that there would not be any defect in electric signal delivery.

  • PDF

Feasibility of Combined Heat and Power Plant based on Fuel Cells using Biogas from Macroalgal Biomass (거대조류 바이오매스로부터 생산된 바이오가스를 사용하는 연료전지 기반 열병합발전의 타당성 검토)

  • Liu, Jay
    • Clean Technology
    • /
    • v.24 no.4
    • /
    • pp.357-364
    • /
    • 2018
  • Studies on the production of biogas from third generation biomass, such as micro- and macroalgae, have been conducted through experiments of various scales. In this paper, we investigated the feasibility of commercialization of integrated combined heat and power (CHP) production using biogas derived from macroalgae, i.e., seaweed biomass. For this purpose, an integrated CHP plant of industrial scale, consisting of solid oxide fuel cells, gas turbine and organic Rankine cycle, was designed and simulated using a commercial process simulator. The cost of each equipment in the plant was estimated through the calculated heat and mass balances from simulation and then the techno-economic analysis was performed. The designed integrated CHP process produces 68.4 MW of power using $36ton\;h^{-1}$ of biogas from $62.5ton\;h^{-1}$ (dry basis) of brown algae. Based on these results, various scenarios were evaluated economically and the levelized electricity cost (LEC) was calculated. When the lifetime of SOFC is 5 years and its stack price is $$225kW^{-1}$, the LEC was 12.26 ¢ $kWh^{-1}$, which is comparable to the conventional fixed power generation.

Performance Prediction & Analysis of MGT Co-generation System

  • Hur, Kwang-Beom;Park, Jung-Keuk;Rhim, Sang-Kyu;Kim, Jae-Hoon
    • New & Renewable Energy
    • /
    • v.2 no.3
    • /
    • pp.15-22
    • /
    • 2006
  • As the distributed generation becomes more reliable and economically feasible, it is expected that a higher application of the distributed generation units would be interconnected to the existing grids. This new market penetration using the distributed generation technology is linked to a large number of factors like economics and performance, safety and reliability, market regulations, environmental issues, or grid connection standards. KEPCO, a government company in Korea, has performed the project to identify and evaluate the performance of Micro Gas Turbine(MGT) technologies focused on 30, 60kW-class grid-connected optimization and combined Heat & Power performance. This paper describes the results for the mechanical, electrical, and environmental tests of MGT on actual grid-connection under Korean regulations. As one of the achievements, the simulation model of Exhaust-gas Absorption Chiller was developed, so that it will be able to analyze or propose new distributed generation system using MGT. In addition, KEPCO carried out the field testing of the MGT Cogeneration system at the R&D Center Building, KEPCO. The field test was conducted in order to respond to a wide variety of needs for heat recovery and utilization. The suggested method and experience for the evaluation of the distributed generation will be used for the introduction of other distributed generation technologies into the grid in the future.

  • PDF

PV Power Prediction Models for City Energy Management System based on Weather Forecast Information (기상정보를 활용한 도시규모-EMS용 태양광 발전량 예측모델)

  • Eum, Ji-Young;Choi, Hyeong-Jin;Cho, Soo-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.393-398
    • /
    • 2015
  • City or Community-scale Energy Management System(CEMS) is used to reduce the total energy consumed in the city by arranging the energy resources efficiently at the planning stage and controlling them economically at the operating stage. Of the operational functions of the CEMS, generation forecasting of renewable energy resources is an essential feature for the effective supply scheduling. This is because it can develop daily operating schedules of controllable generators in the city (e.g. diesel turbine, micro-gas turbine, ESS, CHP and so on) in order to minimize the inflow of the external power supply system, considering the amount of power generated by the uncontrollable renewable energy resources. This paper is written to introduce numerical models for photo-voltaic power generation prediction based on the weather forecasting information. Unlike the conventional methods using the average radiation or average utilization rate, the proposed models are developed for CEMS applications using the realtime weather forecast information provided by the National Weather Service.

A Study on Design of the Linear Generator in the Double Acting Stirling Engine (양방향 스털링엔진의 선형발전기 설계에 관한 연구)

  • PARK, SEONGJE;KO, JUNSEOK;HONG, YONGJU;KIM, HYOBONG;YEOM, HANKIL;IN, SEHWAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.6
    • /
    • pp.638-644
    • /
    • 2015
  • This paper describes the continuing effort to analysis and design on dynamic and electrical behavior of gamma-type free piston Stirling engine/generator with dual-opposed linear generator for domestic micro-CHP (Combined Heat and Power) system. The double acting Stirling engine/generator has one displacer and two power piston which are supported by flexure springs. Two power pistons oscillate with symmetric sinusoidal displacement and are connected with moving magnet type linear generators for power generation. To operate Stirling engine/generator, combustion heat of natural gas is supplied to hot-end and heat is rejected from cold-end by cooling water. The temperature difference across the displacer induces the oscillating motion, and it can be explained with mass-spring vibration system. The purpose of this paper is to describe the design process of linear generator for the double acting free-piston Stirling engine.