• Title/Summary/Keyword: Micro wave

Search Result 516, Processing Time 0.028 seconds

Efficacy of reciprocating instruments and final irrigant activation protocols on retreatment of mesiobuccal roots of maxillary molars: a micro-CT analysis

  • Lilian Tietz;Renan Diego Furlan;Ricardo Abreu da Rosa;Marco Antonio Hungaro Duarte;Murilo Priori Alcalde;Rodrigo Ricci Vivan;Theodoro Weissheimer;Marcus Vinicius Reis So
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.1
    • /
    • pp.13.1-13.13
    • /
    • 2022
  • Objectives: This study evaluated the efficacy of 3 reciprocating systems and the effects of 2 instruments for irrigant activation on filling material removal. Materials and Methods: Forty mesiobuccal roots of maxillary molars were prepared up to size 25.06 and obturated. Micro-computed tomography (micro-CT) examination #1 was performed. Teeth were then divided into 4 groups (n = 10), according to the retreatment protocol: (1) manual, (2) Reciproc Blue, (3) WaveOne Gold, and (4) X1 Blue. Micro-CT examinations #2 and #3 were performed after filling removal and repreparation, respectively. Next, all teeth were divided into 2 new groups (n = 20) according to the irrigant activation protocol: XP Clean (XP Clean size 25.02) and Flatsonic (Flatsonic ultrasonic tip). Micro-CT examination #4 was performed after irrigant activation. Statistical analysis was performed with a significance level set at 5%. Results: WaveOne Gold removed a significantly greater amount of filling material than the manual group (p < 0.05). The time to reach the WL was similar for all reciprocating systems (p > 0.05). X1 Blue was faster than the manual group (p < 0.05). Only manual group improved the filling material removal after the repreparation stage (p < 0.05). Both activation protocols significantly improved the filling material removal (p < 0.05), without differences between them (p > 0.05). Conclusions: None of the tested instruments completely removed the filling material. X1 Blue size 25.06 reached the working length in the shortest time. XP Clean and Flatsonic improved the filling material removal.

Present Condition and View on the Wireless Communications of Geo-spatial Video System in Subway Trains (대열차 공간 화상설비의 무선설비 현황 및 전망)

  • Kim, Ji-Ho;Lee, Hyang-Beom
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.366-370
    • /
    • 2007
  • This paper discusses a most suitable wireless communications system for subway trains on condition that a geo-spatial video system is implemented in subway trains. Geo-spatial video system for subway trains refers to the device that can transfers the images captured by cameras within a subway station building or in and around a subway track to on coming trains wirelessly, which allows the operator in operating room to monitor the state of a platform and a subway track, the flow of passengers, and the condition of passengers getting on and off. To minimize the problem, secure civil safety and prevent accidents and calamity from occurring, a geo-spatial video system for subway trains has been increasingly introduced. The wireless communications systems for GVS for subway trains involve HF(High Frequency), IR(Infra Red), M/W(Micro Wave), wireless LAN approaches. Each has its own strengths/weaknesses, and different vendors have different technology.

  • PDF

Design of valveless type peristaltic micro-pump (밸브레스 연동(連動) 압전펌프의 설계 및 특성)

  • Oh, Jin-Heon;Jeong, Eui-Hwan;Lim, Jong-Nam;Lim, Kee-Joe;Song, Jae-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1301_1302
    • /
    • 2009
  • Recently, there has been increased incessantly an interest in research area on micro-fluidic pump for electronic and biological applications. The proposed pump takes an unobtrusive operation into the simple displacing mechanism using peristaltic traveling waves without the physical moving valves. And, this piezopump makes up a panel type design. The ATILA simulation was performed to estimate the operating frequency of the vibrating wave mode, to optimize the design conditions of piezopump such as structure, elastic body material, piezoelectric ceramics, and to analyze the distribution of vibration displacement. The best measured value of the pumping rate is about $118{\mu}l$/min under the following parameters : 4-wave mode, 50kHz operating frequency, $200V_p$.

  • PDF

Synthesis of fiber-textured diamond films by MWPECVD (마이크로파 플라즈마 CVD법에 의한 섬유집합조직 다이아몬드막의 합성)

  • 박재철;김병상
    • Electrical & Electronic Materials
    • /
    • v.9 no.5
    • /
    • pp.470-475
    • /
    • 1996
  • Fiber-textured diamond films have been deposited on scratched silicon(100) substrate by micro wave .plasma enhanced chemical vapor deposition at the condition of micro wave power : 950 W, pressure : 60 torr, H$_{2}$ gas flow rate : 50 sccm, CH$_{4}$ gas flow rate : 1.5 sccm, substrate temperature : about 900.deg. C and deposition time : 20 hours. The films were characterized by mean of scanning electron microscopy, Raman spectroscopy and X-ray analysis.

  • PDF

Control of Three Phase VSI using Fundamental Data of the Carrier and Signal for Reducing the THO (반송파와 신호파의 기본 데이터를 이용한 3상 전압형 인버터의 THD 저감 제어)

  • Kim, Yeong-Min;Hwang, Jong-Sun;Kim, Jong-Man;Park, Hyun-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.09a
    • /
    • pp.34-37
    • /
    • 2001
  • This research suggested the new algorithm controlled by micro processor which is already stored by various PWM form of output voltage by using fundamental data of the carrier and signal. The determined PWM pattern is not concerned with the signal wave form and the new algorithm can obtain the desired pulse width by synchronous of carrier. The PWM wave can be controlled with real time by using extra hardware and digital software and to speed up program processing, the control signals to switch the power semi-conductor of three phase PWM inverter, simultaneously use the output signal by microprocessor and extra hardware, and control signal by software. In the end, this method was proved by applying to Three phase voltage source inverter.

  • PDF

Modulus and Damping Properties of Kaolinite Using Ultrasonic Testing (초음파를 이용한 카올린 점토의 계수 및 감쇠 특성)

  • 민덕기
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.6
    • /
    • pp.17-24
    • /
    • 2002
  • The objective of the present research is to evaluate the wave propagation velocity and attenuation characteristics of kaolin clay specimens using ultrasonic testing. Test specimens with known initial micro-fabric were prepared using a two-stage slurry consolidation technique. For a known state of stress conditions, initial void ratio, and micro-fabric, a series of experiments were conducted to evaluate the longitudinal wave propagation velocity and associated damping behavior. The effects of major variables involved in ultrasonic testing of cohesive soil were considered in this study. Ultrasonic velocity was not correlated to the microfabric structure under the given consolidated pressure whereas ultrasonic attenuation was affected by the microstructural properties of the specimen.

Design of Electronic Ballast for 35[W] Ceramic Metal Halide Lamp by DBI Structure (DBI 구조를 이용한 35[W] 세라믹 메탈 할라이드 램프용 전자식 안정기의 설계)

  • Park, Chong-Yun;Choe, Wang-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.1-7
    • /
    • 2010
  • Ceramic metal halide lamps have been widely used due to long lifetime, high luminous efficiency and good colour rendering. 35[W] ceramic metal halide lamps has very different characteristics between ignition state and steady state. The developed electronic ballast is satisfied to both ignition state and steady state characteristics by using a micro-controller. The proposed electronic ballast is consists of EMI filter, Full-wave rectifier, Active PFC, DBI(Dual Buck Inverter), Igniter and control circuit. It enables to supply both low-frequency rectangular wave voltage and current to the lamp by using DBI(Dual Bcuk Inverter) structure.

Slider-Bearing Design with Micro-Machined Wavy-Cavity: Parametric Characterization of Thermohydrodynamic-Operation-Scheme

  • Ozalp B. Turker;Ozalp A. Alper
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.10
    • /
    • pp.1590-1606
    • /
    • 2006
  • Slider bearings are widely applied in mechanical systems, where the design needs cover increased load capacity, lowered friction and power consumption and creative designs. This work is governed to perform a parametric characterization, by generating a novel structure on the upper slider surface, which can formally be expressed in micro-machined wavy-form, where the individual and combined influences of various structural design parameters and boundary conditions, on the performance records, are also evaluated. Computations put forward that the contribution of the wave amplitude on power loss values is highly dependent on the level of inlet pressure; higher amplitudes are determined to increase power loss in the lowest inlet pressure case of 1.01, whereas the contrary outcome is determined in the higher inlet pressure cases of 3.01 & 5.01. Designing the slider bearing system, based on optimal load capacity, produced the optimum wave number ranges as 10-45, 7-11 and 5-8 for the pad inclinations of $5^{\circ},\;4^{\circ}$ and $3^{\circ}$ respectively.

Particle Acceleration via Laser Ablation

  • Choi, Ji-Hee;Yoh, Jai-Ick
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.566-569
    • /
    • 2008
  • Recently, the biolistic process is emerging as an effective needle-free drug delivery technique to transfer adequate concentrations of pharmacologic agents to soft living tissues with minimum side effects. We have started developing an effective method for delivering drug coated particles using laser ablation. A thin metal foil with deposited micro-particles on one side is irradiated with laser beam on the opposite side so that a shock wave is generated. This shock wave travels through the foil and is reflected, which causes and instantaneous deformation of the foil. Due to such a sudden deformation, the micro-particles are ejected at a very high speed. Here we present the experimental results of direct and confined laser ablation, which correspond to the initial stage of the whole experiment.

  • PDF

Design and fabrication of a new piezoelectric paper feeder actuator without mechanical parts

  • Ghorbanirezaei, Shahryar;Hojjat, Yousef;Ghodsi, Mojtaba
    • Smart Structures and Systems
    • /
    • v.24 no.2
    • /
    • pp.183-191
    • /
    • 2019
  • A piezoelectric paper feeder actuator using Micro Virtual Roller (MVR) is proposed, designed, fabricated and tested. This actuator can drive a sheet of paper forward or backward without any mechanical parts, such as the costly and heavy rollers used in traditional paper feeders. In this paper feeder actuator, two vibrating stators which produce traveling waves are used to drive the paper. The vibrations of the stators are similar to those of piezoelectric motors and follow a similar procedure to move the paper. A feasibility study simulated the actuator in COMSOL Multiphysics Software. Traveling wave and elliptical trajectories were obtained and the dimensions of the stator were optimized using FEM so that the paper could move at top speed. Next, the eigenfrequencies of the actuator was determined. Experimental testing was done in order to validate the FEM results that revealed the relationships between speed and parameters such as frequency and voltage. Advantages of this new mechanism are the sharp decrease in power consumption and low maintenance.