• Title/Summary/Keyword: Micro sampling technique

Search Result 29, Processing Time 0.035 seconds

A Study on the Determination of Some Heavy Metals using Micro Sampling Technique in Flame Atomic Absorption Spectrophotometry (불꽃원자 흡수 분광법의 Micro Sampling Technique 에 의한 미량 중금속의 분석에 관한 연구)

  • Won Lee
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.3
    • /
    • pp.220-225
    • /
    • 1985
  • An attempt was made to determine some trace metals in highly concentrated samples using micro sampling technique in flame atomic absorption spectrophotometry. Major instrumental parameters and optimun analytical conditions investigated were the measuring time of instrument (the speed of electronics), sample volume, burner height, aspiration rate, and fuel to oxidant ratio. Advantages of the present technique are not only rapid, simple, and sensitive with good precision but also capability of analyzing small volume of sample and ability to handle highly concentrated samples without serious burner clog-up problem compared to conventional flame atomic absorption.

  • PDF

Authentication Test of Archaeological Materials using Single Grain Regenerative Dose Method (단일입자재현법(單一粒子再現法)을 활용한 고고유물의 진위판별 연구)

  • Kim, Myung-Jin;Youn, Min-Young;Hong, Duk-Geun
    • Journal of Conservation Science
    • /
    • v.23
    • /
    • pp.73-80
    • /
    • 2008
  • This article aims to turn out the authentication of archaeological materials by using the paleodose measurement to fine sand-size quartz grains obtained by micro sampling technique. We firstly revealed the validity of micro sampling technique from the paleodoses of two bricks related to Muryong Royal Tomb of Baekje Kingdom. For the purpose of authentication test, four archaeological materials were selected, because they have been insisted that they were manufactured in Goguryeo Kingdom era. After obtaining very few quartz grains by micro sampling technique, each paleodose was evaluated by using SGR (single grain regenerative dose method). All values were very low below 0.2Gy and the reliability was found from those values by using SAR (single aliquot regenerative dose method). Considering the archaeological situation and the general paleodose, the burial time for 1,000 years generally corresponds to about 3.5Gy in Korea, it is concluded that these archaeological materials are all modern counterfeits.

  • PDF

Low Noise and Low Power IC Using Opamp Sharing Technique for Capacitive Micro-Sensor Sensing Platform (증폭기 공유 기법을 이용한 저전력 저잡음 용량형 센서용 신호 처리 IC)

  • Park, Yunjong;Kim, Choul-Young;Jung, Bang Chul;Yoo, Hoyoung;Ko, Hyoungho
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.60-65
    • /
    • 2017
  • This paper describes the low noise and low power IC using the opamp sharing technique for the capacitive micro-sensor sensing platform. The proposed IC reduces noise using correlated double sampling (CDS) and reduces power consumption using the opamp sharing technique. The IC is designed to be fully programmable, and can be digitally controlled by serial peripheral interface (SPI). The power consumption and the integrated input referred noise are 1.02 mW from a 3.3 V supply voltage and $0.164aF_{RMS}$ with a bandwidth of 400 Hz. The capacitive sensitivity, the input-output linearity and the figure of merits (FoM) are 2.5 mV/fF, 2.46 %FSO, and 8.4, respectively.

Pain and Blood Volume with Different Sampling Sites and Puncture Depths in Vacuum Assisted Auto Lancing Technique for Blood Glucose Test (혈당검사를 위한 진공자동채혈기법사용시 채혈부위와 바늘침투깊이에 따른 통증과 채혈량 분석)

  • Park, Mi-Sook;Park, Kyung-Soon;Kim, Kyung-Ah;Cha, Young-Joo;Jun, Myung-Hee;Kim, Tae-Im;Lee, Tae-Soo;Cha, Eun-Jong
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.12 no.2
    • /
    • pp.265-271
    • /
    • 2006
  • Purpose: To analyze the newly developed vacuum assisted auto-lancing technique applied to the forearm for the purpose of obtaining an adequate blood sample for glucose test with minimal pain. Methods: Visual and facial pain measures were introduced to compare lancing pain between the forearm and fingertip in 58 normal females. Sampled blood volumes were accurately measured by computer scanning technique. Results: Visual pain measure demonstrated significant pain reduction effect of the forearm sampling compared with the traditional fingertip sampling, which was also consistent with facial pain measure results. Blood volume more than $0.5{\mu}L$, enough for blood glucose testing with modern glucometers, was collected in 399(86%) of 464 forearm samples. Conclusions: Capillary blood sampling could be performed with minimal pain on the forearm by the newly developed vacuum assisted auto-lancing technique. With some resampling when necessary, the forearm sampling seemed very useful, considering almost no pain felt by the patients.

  • PDF

Manufacturing of Micro-needle Using Micro-EDM Process (마이크로 EDM공정을 이용한 마이크로 바늘의 제조)

  • Lee, Choon-Mee;Kwon, Won Tae
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.3
    • /
    • pp.285-291
    • /
    • 2017
  • Micro-needles are used as transferring devices for sampling of tiny constitute substances from biological bodies. Typically, nickel is used as a coating to improve the rigidity of micro-needles. This study introduces the methodology to manufacture a WC needle with very high hardness and toughness. Micro-EDM technology was used to manufacture micro-needles with holes $130{\mu}m$ in diameter and $2300{\mu}m$ in length. A micro-needle was aligned to the micro-EDM electrode using a custom two degree-of-freedom alignment system. A three-step manufacturing technique was developed to drill a micro-hole using a WC electrode. In the first process, an electrode $105{\mu}m$ in diameter was used to make a hole. Electrodes of 90 and $105{\mu}m$ diameters were used in the second and third process, respectively. Consequently, a WC micro-needle with an inner hole of $135{\mu}m$ diameter, length of $2300{\mu}m$, and outer diameter of $300{\mu}m$ was developed.

A Study on the Design of a ROIC for Uncooled Infrared Ray Detector Using Differential Delta Sampling Technique (차동 델타 샘플링 기법을 이용한 비냉각형 적외선 검출회로의 설계에 관한 연구)

  • Jung, Eun-Sik;Kwan, Oh-Sung;Lee, Po;Jeong, Se-Jin;Sung, Man-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.5
    • /
    • pp.387-391
    • /
    • 2011
  • A uncooled infrared ray sensor used in an infrared thermal imaging detector has many advantages. But because the uncooled infrared ray sensor is made by MEMS (micro-electro-mechanical system) process variation of offset is large. In this paper, to solve process variation of offset a ROIC for uncooled infrared ray sensor that has process variation of offset compensation technique using differential delta sampling and reference signal compensation circuit was proposed. As a result of simulation that uses the proposed ROIC, it was possible to acquire compensated output characteristics without process variation of offsets.

A Site Specific Characterization Technique and Its Application

  • Kamino, T.;Yaguchi, T.;Ueki, Y.;Ohnish, T.;Umemura, K.;Asayama, K.
    • 한국전자현미경학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.18-22
    • /
    • 2001
  • A technique to characterize specific site of materials using a combination of a dedicated focused ion beam system(FIB), and Intermediate-voltage scanning transmission electron microscope(STEM) or transmission electron microscope(TEM) equipped with a scanning electron microscope(SEM) unit has been developed. The FIB system is used for preparation of electron transparent thin samples, while STEM or TEM is used for localization of a specific site to be milled in the FIB system. An FIB-STEM(TEM) compatible sample holder has been developed to facilitate thin sample preparation with high positional accuracy Positional accuracy of $0.1{\mu}m$ or better can be achieved by the technique. In addition, an FIB micro-sampling technique has been developed to extract a small sample directly from a bulk sample in a FIB system These newly developed techniques were applied for the analysis of specific failure in Si devices and also for characterization of a specific precipitate In a metal sample.

  • PDF

Collaborative Streamlined On-Chip Software Architecture on Heterogenous Multi-Cores for Low-Power Reactive Control in Automotive Embedded Processors (차량용 임베디드 프로세서에서 저전력 반응적 제어를 위한 이기종 멀티코어 협력적 스트리밍 온-칩 소프트웨어 구조)

  • Jisu, Kwon;Daejin, Park
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.17 no.6
    • /
    • pp.375-382
    • /
    • 2022
  • This paper proposes a multi-core cooperative computing structure considering the heterogeneous features of automotive embedded on-chip software. The automotive embedded software has the heterogeneous execution flow properties for various hardware drives. Software developed with a homogeneous execution flow without considering these properties will incur inefficient overhead due to core latency and load. The proposed method was evaluated on an target board on which a automotive MCU (micro-controller unit) with built-in multi-cores was mounted. We demonstrate an overhead reduction when software including common embedded system tasks, such as ADC sampling, DSP operations, and communication interfaces, are implemented in a heterogeneous execution flow. When we used the proposed method, embedded software was able to take advantage of idle states that occur between heterogeneous tasks to make efficient use of the resources on the board. As a result of the experiments, the power consumption of the board decreased by 42.11% compared to the baseline. Furthermore, the time required to process the same amount of sampling data was reduced by 27.09%. Experimental results validate the efficiency of the proposed multi-core cooperative heterogeneous embedded software execution technique.

Real-Time All-Optical Three-Dimensional Image Projector

  • Jang, Ju-Seog;Javidi, Bahram
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.285-288
    • /
    • 2002
  • We propose the use of synchronously moving micro-optics (lenslet arrays) for image pickup and display in three-dimensional integral imaging to overcome the upper resolution limit imposed by the Nyquist sampling theorem. With the proposed technique, we present an all-optical three-dimensional integral imaging projector. An optically addressed spatial light modulator is used, which potentially provides better image resolution than the conventional CCD and liquid crystal display pair. We present experimental results using a liquid crystal light valve.

  • PDF

Perceived Usefulness of Business Coaching on the Relationship between Entrepreneurial Competencies and Business Success

  • IDRIS, Mohd Mahfudz bin;ABU BAKAR, Saridan bin
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.10
    • /
    • pp.329-338
    • /
    • 2020
  • The present study aims to investigate the perceived usefulness of business coaching as a moderator between the association of entrepreneurial competencies and business success of women micro-entrepreneurs. This study employs a stratified random sampling technique to collect data from women micro-entrepreneurs who attended business coaching sessions. In total, 261 questionnaires were distributed and collected. This study has divided the moderator (i.e., perceived usefulness of business coaching) into two groups, namely, group 1 (with a low mean) and group 2 (with a high mean) for moderation analysis. By using a comparative analysis of the path coefficient for groups 1 and 2, the path is moderated by the perceived usefulness of business coaching if the beta value for group 1 is significant, and the beta value for group 2 is non-significant. The results show that eight out of a total of sixteen hypotheses were supported, while the remaining hypotheses were rejected. The findings of the study suggest that the domains of entrepreneurial competencies for women micro-entrepreneurs, including strategic, commitment, conceptual, opportunity, and relationship competencies, together with the perceived usefulness of business coaching, are vital for the business success and should remain the principal focus of future research in women entrepreneurship.