• Title/Summary/Keyword: Micro cone

Search Result 71, Processing Time 0.029 seconds

Fabrication of Niobium Oxide Nanorods by the Anodization Method (양극산화법에 의한 니오븀 산화물 나노로드 제조)

  • Jung, Eun-Hye;Chang, Jeong-Ho;Jeong, Bong-Yong
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.4
    • /
    • pp.196-200
    • /
    • 2011
  • The formation of niobium oxide microcones on niobium substrates was investigated in NaF to the HF electrolytes. This condition builds on the uniqueness of the microstructures niobium oxide. The dimensions and integrity of the bulk microstructures were found to be strongly dependent on potential, temperature, electrolyte composition, and anodization time. The anodic oxide was initially amorphous at all temperatures, but crystalline oxide nucleated during anodization. From XRD patterns of the anodized specimens, the microcones consisted of crystalline $Nb_2O_5$. We demonstrated niobium oxide microcone structures with nanorods. The anodized niobium oxide microcone texture revealed nanorod bundles. The surface of $Nb_2O_5$ microcones is very regular and has a nano-scale. The surface morphologies of the nanorods were examined using FE-SEM. EDS analyses show that the anodically prepared niobium oxide consists of $Nb_2O_5$. The aim of this study is to find the condition of forming the favorable nanorods by anodization method.

A COMPARISON OF THERMOPLASTICIZED INJECIABLE GUTTA-PERCHA TECHNIQUES IN RIBBON-SHAPED CANALS : ADAPTATION TO CANAL WALLS (리본 형태의 근관에서 열연화주입법의 근관벽에 대한 적합도에 관한 연구)

  • Hwang, Hyun-Sook;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.411-420
    • /
    • 2002
  • The aim of this study is to compare the adaptability of thermoplasticized injectable gutta-percha technique to the canal walls in ribbon-shaped canals. Thirty resin models simulated ribbon-shape canals were instrumented to #40 using .06 taper Profile systems. Three groups of each 10 resin models were obturated by the lateral condensation technique(LC) and the two thermoplasticized injectable gutta-percha technique; Ultrafil Endoset+Obtura II(EO) and Ultrafil Firmset(UF), respectively. After resin model were kept at room temperature for 4 days, they were resected horizontally with micro-tome at 1, 2, 3, 4 and 5mm levels from apex. At each levels. image of resected surface were taken using CCD camera under a stereomicroscope at $\times$40 magnification and stored. Ratio of the area of gutta-percha was obtained by calculating area of gutta-percha cone to the total area of canal using digitized image-ana-Iyzing program. The data were collected then analyzed statistically using One-way ANOVA. The results were as follows. 1 At 1mm levels, there was no statistically significant difference in the mean ratio of gutta-percha among the groups. 2. At 2mm level, EO showed the highest mean ratio of gutta-percha (p<0.05) and there was no significant difference between LC and UF. 3. At 3, 4, 5mm levels, EO and UF had significantly greater mean ratio of gutta-percha than LC(p<0.05) and there was no significant difference between EO and UF. In conclusion, the thermoplasticized injectable gutta-percha techniques demonstrated relatively favorable adaptability to canal walls than lateral condensation technique in ribbon-shaped canals except for 1mm level.

Fabrication of Piezoelectric Cantilever with Microcone Tip for Sensing Local Stiffness of Biological Tissue (생체 조직의 국소 강도 측정을 위한 마이크로 콘 팁을 가진 압전 캔틸레버 제작)

  • Roh, Hee Chang;Yang, Dasom;Ryu, WonHyoung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.11
    • /
    • pp.743-748
    • /
    • 2017
  • For diseases that are difficult to detect by conventional imaging techniques, the development of a diagnostic method that allows sensors to be inserted into the human body to aid the diagnosis of local spots of the target tissue, is highly desirable. In particular, it is extremely difficult to determine whether vulnerable plaque can later develop into atherosclerosis using only imaging techniques. However, vulnerable plaques are expected to have slightly different mechanical properties than healthy tissue. In this study, we aim to develop a piezoelectric cantilever-type sensor that can be inserted into the human body and can detect the local mechanical properties of the target tissue. A piezoelectric polymer composite based on $BaTiO_3$ nanoparticles was optimized for fabrication of a piezoelectric cantilever. Next, a micro-cone tip was fabricated at the end of the piezoelectric cantilever by thermal drawing. Finally, stiffness of biological tissue samples was measured with the piezoelectric cantilever sensor for verifying its functionality.

A CONTROLLED CYCLIC LOADING ON THE SURFACE TREATED AND BONDED CERAMIC: STAIRCASE METHOD

  • Yi, Yang-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.298-306
    • /
    • 2008
  • STATEMENT OF PROBLEM: Effect of surface treatment of ceramic under loading does not appear to have been investigated. PURPOSE: The aim of this study was to investigate the effect of surface treatment of esthetic ceramic, which is performed to increase the bonding strength, on the fracture stress under controlled cyclic loading condition. MATERIAL AND METHODS: Sixty 1.0 mm-thick specimens were made from Mark II Vitablocs (Vita Zahnfabrik, Germany) and divided into 3 groups: polished (control), sandblasted, and etched. Specimens of each group were bonded to a dentin analog material base including micro-channels to facilitate the flow of water to the bonding interface. Bonded ceramics were cyclically loaded with a flat-end piston in the water (500,000 cycles, 15Hz). Following completion of cyclic loading, specimens were examined for subsurface crack formation and subsequent stress was determined and loaded to next specimen by the staircase method according to the crack existence. RESULTS: There were significant differences of mean fatigue limit in the sandblasted (222.86 ${\pm}$ 23.42 N) and etched group (222.86 ${\pm}$ 14.16 N) when compared to polished group (251.43 ${\pm}$ 10.6 N) (P<.05; Wald-type pair-wise comparison and post hoc Bonferroni test). Of cracked specimens, surface treated group showed longer crack propagation after 24 hours. All failures originated from the radial cracking without cone crack. Fracture resistance of this study was very low and comparable to failure load in the oral cavity. CONCLUSION: Well controlled cyclic loading could induce clinically relevant cracks and fracture resistance of Mark II ceramic was relatively low applicable only to anterior restorations. Surface treatment of inner surface of feldspathic porcelain in the matsicatory area could influence lifetime of restorations.

Development of the Near Infrared Camera System for Astronomical Application

  • Moon, Bong-Kon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.39.2-39.2
    • /
    • 2010
  • In this paper, I present the domestic development of near infrared camera systems for the ground telescope and the space satellite. These systems are the first infrared instruments made for astronomical observation in Korea. KASINICS (KASI Near Infrared Camera System) was developed to be installed on the 1.8m telescope of the Bohyunsan Optical Astronomy Observatory (BOAO) in Korea. KASINICS is equipped with a $512{\times}512$ InSb array enable L band observations as well as J, H, and Ks bands. The field-of-view of the array is $3.3'{\times}3.3'$ with a resolution of 0.39"/pixel. It employs an Offner relay optical system providing a cold stop to eliminate thermal background emission from the telescope structures. From the test observation, limiting magnitudes are J=17.6, H=17.5, Ks=16.1 and L(narrow)=10.0 mag at a signal-to-noise ratio of 10 in an integration time of 100 s. MIRIS (Multi-purpose InfraRed Imaging System) is the main payload of the STSAT-3 in Korea. MIRIS Space Observation Camera (SOC) covers the observation wavelength from $0.9{\mu}m$ to $2.0{\mu}m$ with a wide field of view $3.67^{\circ}{\times}3.67^{\circ}$. The PICNIC HgCdTe detector in a cold box is cooled down below 100K by a micro Stirling cooler of which cooling capacity is 220mW at 77K. MIRIS SOC adopts passive cooling technique to chill the telescope below 200K by pointing to the deep space (3K). The cooling mechanism employs a radiator, a Winston cone baffle, a thermal shield, MLI of 30 layers, and GFRP pipe support in the system. Opto-mechanical analysis was made in order to estimate and compensate possible stresses from the thermal contraction of mounting parts at cryogenic temperatures. Finite Element Analysis (FEA) of mechanical structure was also conducted to ensure safety and stability in launching environments and in orbit. MIRIS SOC will mainly perform the Galactic plane survey with narrow band filters (Pa $\alpha$ and Pa $\alpha$ continuum) and CIB (Cosmic Infrared Background) observation with wide band filters (I and H) driven by a cryogenic stepping motor.

  • PDF

Micro In-situ Tests on Overconsolidated Clay Prepared in Chambers (토조내에 준비된 과압밀 점토에 대한 모형 원위치 시험)

  • Cho Nam Jun
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.2
    • /
    • pp.5-16
    • /
    • 2005
  • Tn this study, model soil deposits are prepared in large test chambers to minimize the scale effects. Also, slurry of mixture containing 50 percent kaolin clay and 50 percent silica has been consolidated to simulate the process of natural soil deposit formation and to reduce the consolidation time. To provide a more detailed description of varying soil properties along the soil profile of model clay deposits and to compare the in-situ test results with those from prototype tests, miniature in-situ tests, including vane shear, piezoprobe, and cone penetration tests were conducted in each of the clay deposits. The current results indicate that consistent soil deposits were prepared for the current and previous test programs. Also, reasonable predicting methods of prototype behavior based on model in-situ test results were suggested in this study by examining differences between the test results from both the model and prototype tests.

Evaluation of Power Generation Efficiency according to Geometric Characteristics of Reservoir in Micro Vortex Hydro-electric Power Generation System (마이크로 보텍스 수력발전시스템에 있어 저수조의 기하학적 특성에 따른 발전 효율 평가)

  • Jeong, Woo Chang;Kang, Hyun Sil
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.432-432
    • /
    • 2021
  • 우리나라는 대부분의 에너지 공급을 해외에 의존하고 있는 실정이다. 산업통상자원부와 에너지경제연구원에서 발간하는 2018년 에너지통계연보(에너지경제연구원과 산업통상자원부, 2018)에 실린 2010년부터 2017년까지의 에너지수급 균형을 보면 원유, 천연가스, 석탄, 우라늄 등 평균 95.4%의 에너지를 수입하고 있는 실정이다. 수력 및 신재생에너지의 경우 기후변화에 대응하는 수단 그리고 정부의 저탄소에너지 전환 정책으로 인정받아 상대적으로 낮은 에너지 경제성에도 불구하고 꾸준히 보급되고 있다. 우리나라뿐만 아니라 독일, 프랑스, 영국, 중국 그리고 인도와 같은 세계 주요 국가들이 친환경 에너지 정책을 주도함에 따라 향후 신재생에너지의 공급 규모는 크게 확대될 것으로 전망된다. 중력 물 보텍스 마이크로 수력 발전 시스템은 시스템의 상하류부의 수두(hydraulic head) 차에 의해 저류조(basin)에서 발생되는 물의 보텍스 즉 소용돌이(whirlpool)를 이용하여 임펠러(impeller)를 회전시켜 전기에너지를 생산하는 친환경적 재생에너지의 일종이다. 또한, 시스템으로 유입되는 물은 전기에너지 생산을 위한 임펠러를 통과한 후 다시 하천으로 방류되므로 하천 수의 손실 그리고 하천의 물길도 거의 교란 시키지 않는다. 4가구 정도의 연간 가정용 전기 요구량인 12와 15kW 사이의 전기에너지를 생산하기 위해서는 발전시스템의 상류와 하류의 수두차가 단지 1.5에서 1.7m 이하이면 충분한 것으로 알려져 있다. 본 연구에서는 중력 물 보텍스 친환경 마이크로 발전 시스템을 구성하는 저류조(basin)에 대해 최대 발전효율을 발생시키기에 최적인 기하학적 형태를 도출하는 것이며, 이를 위해 저류조의 cone angle에 따른 다양한 저류조 직경 및 물 보텍스 생성을 위한 저류조 형태의 변화, 유입수로와 저류조와의 각도인 notch angle의 변화, 유입부 폭과 유출부 직경, 유입수로의 길이 그리고 유입수로에서의 초기수심과 같은 기하학적 매개변수를 변화시켜 모의를 수행하였다.

  • PDF

Icing Wind Tunnel Tests to Improve the Surface Roughness Model for Icing Simulations (착빙 해석의 표면 거칠기 모델 개선을 위한 착빙 풍동시험 연구)

  • Son, Chankyu;Min, Seungin;Kim, Taeseong;Kim, Sun-Tae;Yee, Kwanjung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.8
    • /
    • pp.611-620
    • /
    • 2018
  • For the past decades, the analytic model for distributed surface roughness has been developed to improve the accuracy of the icing simulation code. However, it remains limitations to validate the developed model and determine the empirical parameters due to the absence of the quantitative experimental data which were focused on the surface state. To this end, the experimental study conducted to analyze the ice covered surface state from a micro-perspective. Above all, the tendency of the smooth zone width which occurs near the stagnation point has been quantitatively analyzed. It is observed that the smooth zone width is increased as growing the ambient temperature and freestream velocity. Next, the characteristics of the ice covered surface under rime and glaze ice have been analyzed. For rime ice conditions, ice elements are developed as the opaque circular corn in the opposite direction of freestream. The height and interval of each circular corn are increased as rising the ambient temperature. For glaze ice conditions, numerous lumps of translucent ice can be observed. This is because the beads formed by gravity concentrate and froze on the lower surface.

DEVELOPMENT OF THE MECHANICAL STRUCTURE OF THE MIRIS SOC (MIRIS 우주관측카메라의 기계부 개발)

  • Moon, B.K.;Jeong, W.S.;Cha, S.M.;Ree, C.H.;Park, S.J.;Lee, D.H.;Yuk, I.S.;Park, Y.S.;Park, J.H.;Nam, U.W.;Matsumoto, Toshio;Yoshida, Seiji;Yang, S.C.;Lee, S.H.;Rhee, S.W.;Han, W.
    • Publications of The Korean Astronomical Society
    • /
    • v.24 no.1
    • /
    • pp.53-64
    • /
    • 2009
  • MIRIS is the main payload of the STSAT-3 (Science and Technology Satellite 3) and the first infrared space telescope for astronomical observation in Korea. MIRIS space observation camera (SOC) covers the observation wavelength from $0.9{\mu}m$ to $2.0{\mu}m$ with a wide field of view $3.67^{\circ}\times3.67^{\circ}$. The PICNIC HgCdTe detector in a cold box is cooled down below 100K by a micro Stirling cooler of which cooling capacity is 220mW at 77K. MIRIS SOC adopts passive cooling technique to chill the telescope below 200 K by pointing to the deep space (3K). The cooling mechanism employs a radiator, a Winston cone baffle, a thermal shield, MLI (Multi Layer Insulation) of 30 layers, and GFRP (Glass Fiber Reinforced Plastic) pipe support in the system. Optomechanical analysis was made in order to estimate and compensate possible stresses from the thermal contraction of mounting parts at cryogenic temperatures. Finite Element Analysis (FEA) of mechanical structure was also conducted to ensure safety and stability in launching environments and in orbit. MIRIS SOC will mainly perform Galactic plane survey with narrow band filters (Pa $\alpha$ and Pa $\alpha$ continuum) and CIB (Cosmic Infrared Background) observation with wide band filters (I and H) driven by a cryogenic stepping motor.

Highly Doped Nano-crystal Embedded Polymorphous Silicon Thin Film Deposited by Using Neutral Beam Assisted CVD at Room Temperature

  • Jang, Jin-Nyeong;Lee, Dong-Hyeok;So, Hyeon-Uk;Hong, Mun-Pyo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.154-155
    • /
    • 2012
  • The promise of nano-crystalites (nc) as a technological material, for applications including display backplane, and solar cells, may ultimately depend on tailoring their behavior through doping and crystallinity. Impurities can strongly modify electronic and optical properties of bulk and nc semiconductors. Highly doped dopant also effect structural properties (both grain size, crystal fraction) of nc-Si thin film. As discussed in several literatures, P atoms or radicals have the tendency to reside on the surface of nc. The P-radical segregation on the nano-grain surfaces that called self-purification may reduce the possibility of new nucleation because of the five-coordination of P. In addition, the P doping levels of ${\sim}2{\times}10^{21}\;at/cm^3$ is the solubility limitation of P in Si; the solubility of nc thin film should be smaller. Therefore, the non-activated P tends to segregate on the grain boundaries and the surface of nc. These mechanisms could prevent new nucleation on the existing grain surface. Therefore, most researches shown that highly doped nc-thin film by using conventional PECVD deposition system tended to have low crystallinity, where the formation energy of nucleation should be higher than the nc surface in the intrinsic materials. If the deposition technology that can make highly doped and simultaneously highly crystallized nc at low temperature, it can lead processes of next generation flexible devices. Recently, we are developing a novel CVD technology with a neutral particle beam (NPB) source, named as neutral beam assisted CVD (NBaCVD), which controls the energy of incident neutral particles in the range of 1~300eV in order to enhance the atomic activation and crystalline of thin films at low temperatures. During the formation of the nc-/pm-Si thin films by the NBaCVD with various process conditions, NPB energy directly controlled by the reflector bias and effectively increased crystal fraction (~80%) by uniformly distributed nc grains with 3~10 nm size. In the case of phosphorous doped Si thin films, the doping efficiency also increased as increasing the reflector bias (i.e. increasing NPB energy). At 330V of reflector bias, activation energy of the doped nc-Si thin film reduced as low as 0.001 eV. This means dopants are fully occupied as substitutional site, even though the Si thin film has nano-sized grain structure. And activated dopant concentration is recorded as high as up to 1020 #/$cm^3$ at very low process temperature (< $80^{\circ}C$) process without any post annealing. Theoretical solubility for the higher dopant concentration in Si thin film for order of 1020 #/$cm^3$ can be done only high temperature process or post annealing over $650^{\circ}C$. In general, as decreasing the grain size, the dopant binding energy increases as ratio of 1 of diameter of grain and the dopant hardly be activated. The highly doped nc-Si thin film by low-temperature NBaCVD process had smaller average grain size under 10 nm (measured by GIWAXS, GISAXS and TEM analysis), but achieved very higher activation of phosphorous dopant; NB energy sufficiently transports its energy to doping and crystallization even though without supplying additional thermal energy. TEM image shows that incubation layer does not formed between nc-Si film and SiO2 under later and highly crystallized nc-Si film is constructed with uniformly distributed nano-grains in polymorphous tissues. The nucleation should be start at the first layer on the SiO2 later, but it hardly growth to be cone-shaped micro-size grains. The nc-grain evenly embedded pm-Si thin film can be formatted by competition of the nucleation and the crystal growing, which depend on the NPB energies. In the evaluation of the light soaking degradation of photoconductivity, while conventional intrinsic and n-type doped a-Si thin films appeared typical degradation of photoconductivity, all of the nc-Si thin films processed by the NBaCVD show only a few % of degradation of it. From FTIR and RAMAN spectra, the energetic hydrogen NB atoms passivate nano-grain boundaries during the NBaCVD process because of the high diffusivity and chemical potential of hydrogen atoms.

  • PDF