• 제목/요약/키워드: Micro computed tomography

검색결과 261건 처리시간 0.025초

Bone Regenerative Effects of Biphasic Calcium Phosphate Collagen, Bone Morphogenetic Protein 2, Mesenchymal Stem Cells, and Platelet-Rich Plasma in an Equine Bone Defect Model

  • Eun-bee Lee;Hyunjung Park;Jong-pil Seo
    • 한국임상수의학회지
    • /
    • 제40권2호
    • /
    • pp.85-92
    • /
    • 2023
  • Fractures in the horse industry are challenging and a common cause of death in racehorses. To accelerate fracture healing, tissue engineering (TE) provides promising ways to regenerate bone tissues. This study aimed to evaluate the osteogenic effects of biphasic calcium phosphate collagen (BCPC) graft, bone morphogenetic protein 2 (BMP2), mesenchymal stem cell (MSC), and platelet-rich plasma (PRP) treatments in horses. Four thoroughbred horses were included in the study, and, in each horse, three cortical defects with a diameter of 5 mm and depth of 10 mm were formed in the third metacarpal bones (MC) and metatarsal bones (MT). The defects were randomly assigned to one of six treatment groups (saline, BCPC, BMP2, MSC, PRP, and control). Injections of saline, BMP2, PRP, or MSCs were made at 1, 3, and 5 weeks after defect surgery. Bone regeneration effects were assessed by radiography, quantitative computed tomography (QCT), micro-computed tomography (μCT), histopathological, and histomorphometric evaluation. The new bone ratio (%) in the histomorphometric evaluation was higher in the BMP2 group than in the control and saline groups. Radiographic and QCT values were significantly higher in the BCPC groups than in the other groups. QCT values of the BMP2 group were significantly higher than in the control and saline groups. The present study demonstrated that BCPC grafts were biologically safe and showed osteoconductivity in horses and the repeated injections of BMP2 without a carrier can be simple and promising TE factors for treating horses with bone fractures.

인체 흉추 해면골의 영역별 형태학적 및 기계적 특성 연구 (Regional Morphological and Mechanical Characteristics in the Human Thoracic Vertebral Trabecular Bones)

  • 이태우;우대곤;고창용;김한성
    • 한국정밀공학회지
    • /
    • 제27권1호
    • /
    • pp.134-141
    • /
    • 2010
  • This study analyzed the regional morphological and mechanical characteristics of vertebrae by using micro-computed tomography (micro-CT) and micro finite element analysis (FEA). For the present study, the $12^{th}$ human thoracic vertebral bones (an 85-years female and a 48-years male) were used. These were scanned by using micro-CT. Structural parameters were evaluated from the acquired 20 image data for fifteen $4{\times}4mm^2$ regions (five regions in respective layers of superior, middle and inferior part) in the thoracic vertebral trabecular bones. $4{\times}4{\times}4mm^3$ cubic finite element models of each regions were created at $70{\mu}m$ voxel resolution to investigate effective modulus ($E^+$). The present study indicated that there were significant differences in morphological and elastic mechanical characteristics of each region. There are close relationship between effective modulus and structural model index (SMI) in the bone of the 48-years male and between effective modulus and bone volume fraction (BV/TV) in the bone of the 85-years female. In addition, the effective modulus of central regions is about 80% stiffer than that of lateral regions at transverse plane. These findings may be likely to explain the previous result that a change of loading distribution of the vertebral trabecular bones is caused by spinal curvature and nucleus pulpous degeneration of the intervertebral disc.

미세단층촬영기(Micro-CT)를 이용한 전자 근관장 측정기의 정확성에 관한 연구 (A Study on the Accuracy of the Electronic Apex Locator Using a Micro-Computed Tomography)

  • 전경진;김양수;남태계
    • 한국정밀공학회지
    • /
    • 제24권8호통권197호
    • /
    • pp.116-121
    • /
    • 2007
  • The length of root canal has to be measured for endodontic treatment. Several electronic apex locators were developed to measure the length of root canal by other researchers. And their accuracies were verified by X-ray or micrometer method. But these methods did not consider the non-linear bends of pulp and had ${\pm}0.5mm$ error which was large enough to measure the length of root canal. The purpose of this study is the introduction of a new method to measure the length of root canal and the verification of the accuracy of an electronic apex locator using a Micro-CT. The length of root canal of 6 teeth were measured with the electronic apex locator. When the electronic apex locator reads 0.5, 0.6, 0.7, 0.8, 0.9 and 1.0 mm length of the file which was inserted in the hole of the tooth to measure the length of root canal. The average (${\pm}$Standard deviation) length of root canal of 6 teeth measured by the Micro-CT was $0.49{\pm}0.03,\;0.59{\pm}0.04,\;0.68{\pm}0.03,\;0.78{\pm}0.03,\;0.90{\pm}0.04\;and\;1.01{\pm}0.03mm$, respectively. The maximum error of the electronic apex locator was 0.06 mm.

Evaluation of reparative dentin formation of ProRoot MTA, Biodentine and BioAggregate using micro-CT and immunohistochemistry

  • Kim, Jia;Song, Young-Sang;Min, Kyung-San;Kim, Sun-Hun;Koh, Jeong-Tae;Lee, Bin-Na;Chang, Hoon-Sang;Hwang, In-Nam;Oh, Won-Mann;Hwang, Yun-Chan
    • Restorative Dentistry and Endodontics
    • /
    • 제41권1호
    • /
    • pp.29-36
    • /
    • 2016
  • Objectives: The purpose of this study was to assess the ability of two new calcium silicate-based pulp-capping materials (Biodentine and BioAggregate) to induce healing in a rat pulp injury model and to compare them with mineral trioxide aggregate (MTA). Materials and Methods: Eighteen rats were anesthetized, cavities were prepared and the pulp was capped with either of ProRoot MTA, Biodentine, or BioAggregate. The specimens were scanned using a high-resolution micro-computed tomography (micro-CT) system and were prepared and evaluated histologically and immunohistochemically using dentin sialoprotein (DSP). Results: On micro-CT analysis, the ProRoot MTA and Biodentine groups showed significantly thicker hard tissue formation (p < 0.05). On H&E staining, ProRoot MTA showed complete dentin bridge formation with normal pulpal histology. In the Biodentine and BioAggregate groups, a thick, homogeneous hard tissue barrier was observed. The ProRoot MTA specimens showed strong immunopositive reaction for DSP. Conclusions: Our results suggest that calcium silicate-based pulp-capping materials induce favorable effects on reparative processes during vital pulp therapy and that both Biodentine and BioAggregate could be considered as alternatives to ProRoot MTA.

In vivo micro-CT를 이용한 난소적출 백서의 골구조 형태계측학적 분석 (Morphometric analysis of bone in the ovariectomized rat using in vivo micro-CT)

  • 이창진;이완;이병도
    • Imaging Science in Dentistry
    • /
    • 제38권1호
    • /
    • pp.29-37
    • /
    • 2008
  • Purpose: The aim of this study was to observe the bony change in the OVX rat longitudinally and to study the alendronate effect. Materials and Methods: Eighteen Sprague-Dewley rats, eight-week old each, were randomly assigned into three groups: one of those sham-operated (N=4), the other two were OVX: saline-treated (N=7) and alendronate-treated group (N=7). The saline-treated group was administered with saline solution (0.1mL/100g) daily, while the alendronate-treated group was given alendronate (1mg/kg, Sigma-Aldrich Corp. Korea) daily. Micro-CT scannings of the lumbar were consecutively done at baseline, at 3-week intervals during 9 weeks. Two and three dimensional bony analysis were done. Bone mineral density (BMD) was measured with Piximus (GE Lunar Co. USA). The average values of these three methods were compared with each group. Results: After 6 weeks the BMD of the OVX group showed lower tendency than that of sham group. After 6 weeks many 3D parameters of micro-CT showed higher values in the OVX-alendronate group compared with the OVXsaline group. Most 2D bony parameters were higher in the OVX-alendronate group compared with the OVX-saline group at 9 weeks. Conclusion: This study showed low BMD of the OVX group after 6 weeks and showed the effect of alendronate on the BMD and bony structures of ovariectomized rats. This study also showed usefulness of in vivo micro-CT in monitoring individual bone changes over time.

  • PDF

Comparison of tooth movement and biological response in corticotomy and micro-osteoperforation in rabbits

  • Kim, Junghan;Kook, Yoon-Ah;Bayome, Mohamed;Park, Jae Hyun;Lee, Won;Choi, Hojae;Abbas, Noha H.
    • 대한치과교정학회지
    • /
    • 제49권4호
    • /
    • pp.205-213
    • /
    • 2019
  • Objective: The aim of this study was to evaluate the amount of tooth movement and histologic changes with different corticotomy designs and micro-osteoperforation in rabbits. Methods: The sample consisted of 24 rabbits divided into three experimental groups (triangular corticotomy [TC] and indentation corticotomy [IC] with flap, and flapless micro-osteoperforations [MP]) and a control. A traction force of 100 cN was applied by connecting the first premolars to the incisors. The amount of tooth movement was measured. Kruskal-Wallis test was used to assess differences in tooth movement between the groups. Micro-computed tomography, hematoxylin and eosin staining, and tartrate-resistant acidic phosphatase (TRAP) analysis were performed. Analysis of variance was applied to assess differences in TRAP-positive osteoclast count between the groups. Results: The amount of tooth movement increased by 46.5% and 32.0% in the IC and MP groups, respectively, while the bone fraction analysis showed 69.7% and 8.5% less mineralization compared to the control. There were no significant intergroup differences in the number of TRAP-positive osteoclasts. Conclusions: The micro-osteoperforation group showed no significant differences in the amount of tooth movement compared to the corticotomy groups, nor in the TRAP-positive osteoclast count compared to both corticotomy groups and control.

The Effect of Uncinate Process Resection on Subsidence Following Anterior Cervical Discectomy and Fusion

  • Lee, Su Hun;Lee, Jun Seok;Sung, Soon Ki;Son, Dong Wuk;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권5호
    • /
    • pp.550-559
    • /
    • 2017
  • Objective : Subsidence is a frequent complication of anterior cervical discectomy and fusion. Postoperative segmental micromotion, thought to be a causative factor of subsidence, has been speculated to increase with uncinate process resection area (UPR). To evaluate the effect of UPR on micro-motion, we designed a method to measure UPR area based on pre- and postoperative computed tomography images and analyzed the relationship between UPR and subsidence as a proxy of micro-motion. Methods : We retrospectively collected clinical and radiological data from January 2011 to June 2016. A total of 38 patients (53 segments) were included. All procedures included bilateral UPR and anterior plate fixation. UPR area was evaluated with reformatted coronal computer tomography images. To reduce level-related bias, we converted UPR area to the proportion of UPR to the pre-operative UP area (pUPR). Results : Subsidence occurred in 18 segments (34%) and positively correlated with right-side pUPR, left-side pUPR, and the sum of bilateral pUPR (sum pUPR) (R=0.310, 301, 364; p=0.024, 0.029, 0.007, respectively). Multiple linear regression analysis revealed that subsidence could be estimated with the following formula : $subsidence=1.522+2.7{\times}sum\;pUPR$($R^2=0.133$, p=0.007). Receiver-operating characteristic analysis determined that sum $pUPR{\geq}0.38$ could serve as a threshold for significantly increased risk of subsidence (p=0.005, area under curve=0.737, sensitivity=94%, specificity=51%). This threshold was confirmed by logistic regression analysis for subsidence (p=0.009, odds ratio=8.471). Conclusion : The UPR measurement method confirmed that UPR was correlated with subsidence. Particularly when the sum of pUPR is ${\geq}38%$, the possibility of subsidence increased.

Micro-CT evaluation of the removal of root fillings using rotary and reciprocating systems supplemented by XP-Endo Finisher, the Self-Adjusting File, or Er,Cr:YSGG laser

  • Gulsen Kiraz;Bulem Ureyen Kaya;Mert Ocak;Muhammet Bora Uzuner;Hakan Hamdi Celik
    • Restorative Dentistry and Endodontics
    • /
    • 제48권4호
    • /
    • pp.36.1-36.15
    • /
    • 2023
  • Objectives: This study aimed to compare the effectiveness of a single-file reciprocating system (WaveOne Gold, WOG) and a multi-file rotary system (ProTaper Universal Retreatment, PTUR) in removing canal filling from severely curved canals and to evaluate the possible adjunctive effects of XP-Endo Finisher (XPF), the Self-Adjusting File (SAF), and an erbium, chromium: yttrium, scandium, gallium garnet (Er,Cr:YSGG) laser using microcomputed tomography (µCT). Materials and Methods: Sixty-six curved mandibular molars were divided into 2 groups based on the retreatment technique and then into 3 based on the supplementary method. The residual filling volumes and root canals were evaluated with µCT before and after retreatment, and after the supplementary steps. The data were statistically analyzed with the t-test, Mann-Whitney U test, analysis of covariance, and factorial analysis of variance (p < 0.05). Results: PTUR and WOG showed no significant difference in removing filling materials (p > 0.05). The supplementary techniques were significantly more effective than reciprocating or rotary systems only (p < 0.01). The supplementary steps showed no significant differences in canal filling removal effectiveness (p > 0.05), but XPF showed less dentin reduction than the SAF and Er,Cr:YSGG laser (p < 0.01). Conclusions: The supplementary methods significantly decreased the volume of residual filling materials. XPF caused minimal changes in root canal volume and might be preferred for retreatment in curved root canals. Supplementary approaches after retreatment procedures may improve root canal cleanliness.

부분 진동이 하지현수에 의한 골다공증 예방에 미치는 효과 (The Effects of Partial Vibration on Trabecular Bone in Tibia of Rats during Hindlimb Suspension)

  • 엄시내;박지형;서동현;김한성
    • 한국정밀공학회지
    • /
    • 제31권8호
    • /
    • pp.749-755
    • /
    • 2014
  • The aim of this study was to assess the effects of artificial unloading induced by hindlimb suspension on the trabecular bone in tibiae. Twenty four 12-week-old Sprague-Dawley rats were assigned to 3 groups, namely, the control group (CON, n = 8), the hindlimb-suspended group (HLS, n = 8) and HLS with partial vibration group (HLSPV, n = 8). After 4 weeks, compared with CON group, HLS group had significantly greater decreases on BMD, BV/TV, Tb.N, Conn.Dn and increase on Tb.Sp (p < 0.05). However, there were no significant differences in BMD and the other micro structural parameters of tibial trabecular bones between CON and HLSPV (p > 0.05). These results implied that partial vibration might inhibit the bone loss induced by hindlimb suspension. Furthermore, we could expect to apply partial vibration system in space environment, to prevent bone loss in astronauts.

Fabrication and Characterization of Electrospun PLGA/Gelatin Nanofiber Tube for Potential Intestinal Stent Application

  • Son, So-Ra;Franco, Rose-Ann;Bao, Trinh-Quang;Bae, Sang-Ho;Min, Young-Ki;Lee, Byong-Taek
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.51.1-51.1
    • /
    • 2011
  • An electrospun Poly (lactice-co-glycolide acid) (PLGA) and Gelatin nanofiber tube was fabricated for potential intestinal stent application. Mechanical properties of tube were evaluated by tensile strength and burst strength tests. Physical and chemical properties were evaluated by contact angle measurement, swelling rates and porosity measurements. Biodegradability was investigated by immersion in simulated body fluid (SBF). Biocompatibility was investigated in vitro by cytotoxicity and proliferation studies by MTT assay, confocal microscopy and western blot using IEC-18 (Rat intestinal epithelial cell). After intestinal stent was implanted into rat bowel for periods from 7 to 10days, it was then analyzed using micro-computed tomography (Micro CT) and X-ray techniques. Futhermore, histological analysis was performed by hematoxylin-eosin (H&E) stain.

  • PDF