• Title/Summary/Keyword: Micro cavity

Search Result 178, Processing Time 0.031 seconds

Micro-CT evaluation of internal adaptation in resin fillings with different dentin adhesives

  • Han, Seung-Hoon;Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.1
    • /
    • pp.24-31
    • /
    • 2014
  • Objectives: The purpose of present study was to evaluate the internal adaptation of composite restorations using different adhesive systems. Materials and Methods: Typical class I cavities were prepared in 32 human third molars. The teeth were divided into the following four groups: 3-step etch-and-rinse, 2-step etch-and-rinse, 2-step self-etch and 1-step self-etch system were used. After the dentin adhesives were applied, composite resins were filled and light-cured in two layers. Then, silver nitrate solution was infiltrated, and all of the samples were scanned by micro-CT before and after thermo-mechanical load cycling. For each image, the length to which silver nitrate infiltrated, as a percentage of the whole pulpal floor length, was calculated (%SP). To evaluate the internal adaptation using conventional method, the samples were cut into 3 pieces by two sectioning at an interval of 1 mm in the middle of the cavity and they were dyed with Rhodamine-B. The cross sections of the specimens were examined by stereomicroscope. The lengths of the parts where actual leakage was shown were measured and calculated as a percentage of real leakage (%RP). The values for %SP and %RP were compared. Results: After thermo-mechanical loading, all specimens showed significantly increased %SP compared to before thermo-mechanical loading and 1-step self-etch system had the highest %SP (p < 0.05). There was a tendency for %SP and %RP to show similar microleakage percentage depending on its sectioning. Conclusions: After thermo-mechanical load cycling, there were differences in internal adaptation among the groups using different adhesive systems.

Influence of porosity on the behavior of cement orthopaedic of total hip prosthesis

  • Ali, Benouis;Boualem, Serier;Smail, Benbarek
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.2 no.4
    • /
    • pp.197-206
    • /
    • 2015
  • This paper presents three-dimensional finite element method analyses of the distribution of equivalents stress of Von Mises. Induced around a cavity located in the bone cement polymethylmethacrylate (PMMA). The presences and effect of its position in the cement was demonstrated, thus on the stress level and distribution. The porosity interaction depending on their positions, and their orientations on the interdistances their mechanical behaviour of bone cement effects were analysed. The obtained results show that micro-porosity located in the proximal and distal zone of the prosthesis is subject to higher stress field. We show that the breaking strain of the cement is largely taken when the cement, containing the porosities very close adjacent to each other.

Antimicrobial Action of Dental Cements (치과용 시멘트의 항미생물 작용)

  • Kim, Cheol-We;Seonoo, Young-Gook;Paik, Dae-Il;Kim, Jong-Bai;Choe, Son-Jin
    • The Journal of the Korean dental association
    • /
    • v.21 no.7 s.170
    • /
    • pp.573-577
    • /
    • 1983
  • The antimicrobial action of various dental cements evaluated against common micro-organisms most frequenty found within the components of the normal bacterial flora of oral cavity. They include Streptococcus mutans (2 strains), Lactobacillus acidophilus, Actinomyces viscosus, and Streptococcus sanguis. The test was done by the use of brain heart infusion (BHI) agar plates. A standard mix of each cement was made and placed on the plates which were seeded with a standard culture of microorganisms. After incubation, the halo of bacterial growth inhibition around the cement was identified and its size was measured. Some of the cements tested had obvious antibacterial effect. The cements listed in decreasing order of effectiveness are 1) zinc phosphate and oxyphosphate, 2) silicate, 3) zinc oxide-eugenol, 4) calcium hydroxide, and 5) carboxylate.

  • PDF

A study on the effect of micro cavity of top emission organic light-emission diode (전면 발광 유기발광다이오드의 마이크로 캐비티 효과에 관한 연구)

  • Han, Ga-Ram;Kim, Il-Young;Min, Sang-Hong;Kim, Hyun-Su;Hong, Chin-Soo;Kim, Chang-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1513-1514
    • /
    • 2011
  • 본 논문에서는 양극을 Ni, Au, Ag 등으로 하여 소자를 만들어 본 후에 가장 효율이 좋은 금속으로 양극을 정하고 유기물 층의 두께에 따른 마이크로 캐비티에 의한 스펙트럼의 이동효과를 시뮬레이션을 통해 살펴보았다. 소자의 기본 구조는 전면 발광 방식으로 양극/NPB/Alq3/LiF/Al이다. 음극을 LiF/Al과 Mg/Ag로 구조로 제작한 후에 기본 구조와 결과를 비교하였다. 실험결과를 시뮬레이션 결과와 비교 검토하였다.

  • PDF

The Electric Control Method on the Packaging Technology for Non-Conductive Materials Using the Surface Processing Cavity Pressure Sensor (표면 가공형 캐비티 압력센서를 이용하여 비전도성 물질용 패키지 기술에 전기적 제어방식 연구)

  • Lee, Sun-Jong;Woo, Jong-Chang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.5
    • /
    • pp.350-354
    • /
    • 2020
  • In this study, a pressure sensor for each displacement was fabricated based on the silicon-based pressure sensor obtained through simulation results. Wires were bonded to the pressure sensor, and a piezoresistive pressure sensor was inserted into the printed circuit board (PCB) base by directly connecting a micro-electro-mechanical system (MEMS) sensor and a readout integrated circuit (ROIC) for signal processing. In addition, to prevent exposure, a non-conductive liquid silicone was injected into the sensor and the entire ROIC using a pipette. The packaging proceeded to block from the outside. Performing such packaging, comparing simple contact with strong contact, and confirming that the measured pulse wavelength appears accurately.

Minimization of Weld Lines in Two Shot Molded Parts with Microlenses (미소 렌즈가 내재화된 이중사출 성형제품의 웰드라인 최소화)

  • 신주경;민병권;김영주;강신일
    • Transactions of Materials Processing
    • /
    • v.13 no.3
    • /
    • pp.230-235
    • /
    • 2004
  • A new design based on the appropriate geometry of molded part and type of runner system under the optimal processing conditions was proposed to minimize the micro weld lines on the sub deco surface molded by two shot molding. Theoretical and experimental studies were conducted to examine the cause of the weld lines during the overmolding process in two shot molding. Various dimensions and geometries of substrate$(1^{st}shot)$ and the wall thickness of overmold$(2^{nd}shot)$ have been proposed to avoid the weld lines which are the most inevitable appearance defects occurred on the sub deco. The each design proposal was analyzed by mold flow analysis after part modeling. The analysis results were compared with molded part from mass production tool. It could be seen that from the analysis that the proper geometry of plastic part and type of runner system considering pressure drop under the optimal processing conditions were the most influential factors to avoid weld lines occured on the sub deco.

Silver Materials Induce Differential Cytotoxicity and Pulmonary Toxicity Based on Size and Shape

  • Pak, Pyo June;Kang, Beob Hwa;Chung, Namhyun
    • Journal of Applied Biological Chemistry
    • /
    • v.58 no.2
    • /
    • pp.113-116
    • /
    • 2015
  • Silver materials may be toxic in humans because they can enter the body and accumulate, typically in the lungs. We hypothesized that the cytotoxicity of naive silver materials is affected by their size and shape. Our in vitro assays revealed that the overall toxicity was in the following order: submicro-particles>wires>micro-particles. These results contrast with previous studies, which showed that silver wires are the most toxic among the three tested materials, possibly due to differences in cell lines. Evaluations of in vivo pulmonary toxicity revealed eryptosis in the cavity lining of the lung sections. The observed eryptosis was consistent with the in vitro results. Our results indicate that silver materialinduced cytotoxicity must be measured and compared using various methods.

A Study on the Development of Cathode-Ray Tube Die Using Hot forging (열간단조를 이용한 브라운관 금형의 개발에 관한 연구)

  • 차도진;조종래;배원병;황남철
    • Transactions of Materials Processing
    • /
    • v.9 no.5
    • /
    • pp.533-538
    • /
    • 2000
  • This study has been carried out to develop a CRT die using hot forging. The conventional CRT die made by casting has defects such as void and inclusion. These defects of the cast die make micro-spots on the surface of the CRT which affect the quality of the final product. So, a hot forging process is developed to avoid these defects of CRT die by the model material test and the rigid-plastic FEM. Firstly, model material tests are carried out with plasticine billets in order to investigate the material flow pattern in the die cavity and to get the reasonable initial values for designing the preform in the FE simulation. And then a finite element analysis has been performed to Predict the preform and the forging load of a CRT die. We also suggest an integrated die-set which combines two die-sets into one die-set to save manufacturing time and cost in case of similar die-size.

  • PDF

Application simulations as numerical laboratory for large diameter rockfill materials (대입경 락필재료에 대한 수치시험실 활용해석)

  • Jeon, Je-Sung
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.852-855
    • /
    • 2010
  • Numerical simulations for large scale triaxial tests with large diameter rockfill materials are conducted using distinct element method. For generation of compacted assembly with specific grain size distribution and initial material porosity, the clump logic method and expansion of generated particles are adapted. With micro parameters which are chosen by calibration process, discrete particle modelling of triaxial test in case of other confining stress and cyclic loading condition were conducted. Also numerical simulations of fluid injection into particulate materials were conducted to observe cavity initiation and propagation using distinct element method. The fluid scheme solves the continuity and Navior-Stokes equations numerically, then derives pressure and velocity vectors for fixed grid by considering the existence of particles within the fluid cell.

  • PDF

Frequency Stabilization of He-Ne laser using One Chip Micro-Processor (1칩 마이크로 프로세서를 이용한 He-Ne 레이저의 주파수 안정화)

  • 최현승;엄태봉;이선규
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.102-105
    • /
    • 2000
  • A simple digital control system has been developed for the frequency stabilization of an internal mirror He-Ne laser. The system is based on one chip microprocessor with embedded Basic interpreter. To stabilize the laser output frequency, the signal such as power difference or beat frequency between two modes is supplied and processed by a microprocessor, and control signal is fed to the heating coil would round the laser tube for adjusting the spacing of the laser cavity mirror. Newly developed frequency stabilization system is totally digitized. The system and the frequency stability performance are briefly described.

  • PDF