• Title/Summary/Keyword: Micro Robotics

Search Result 229, Processing Time 0.029 seconds

The Parameter Identification for Localization Scheme of the Optics-Based Micro Sensor Node (광신호 기반의 마이크로 센서 노드 위치 인식 시스템을 위한 파라미터 식별)

  • Jeon, Ji-Hun;Lee, Min-Su;Park, Chan-Gook
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.2
    • /
    • pp.81-86
    • /
    • 2013
  • In this paper, the parameter identification for localization scheme for the optics-based micro sensor node is conducted. We analyzed short measurement range problem which can be occurred in optical based micro sensor node localization method using a time of flight. And we set up the theory for distance and maximum reflected laser power to overcome the problem by identifying hardware parameters like laser power, effective area of MEMS CCR, sensitivity of photodetector, and so on. Experimental results of measurement of maximum reflected laser power were compared with results of the theory. By using the theory, we can identify hardware parameters of localization scheme to measure particular position of the optics-based micro sensor node.

Multimedia network system

  • Fukuda, Toshio;Arai, Fumihito
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10a
    • /
    • pp.13-16
    • /
    • 1996
  • Based on the technical innovation of the recent communication system technologies, systems are linked by the worldwide network. We introduce some examples of the multimedia network systems. Especially, we introduce our recent attempt to realize the multimedia tele-surgery system using high speed optical fiber network. At first, we shows the technical problems of the multimedia tele-surgery. We applied this idea to the intravascular neurosurgery. System configuration for the prototype experiments and experimental results are shown.

  • PDF

High precision tracking contorl algorithm for micro electrostatic actuator with nonlinearity (Nonlinearity를 갖는 Micro Electorstatic Actuator의 초정밀 추종제어)

  • 김경한;최현택;송재욱;정완균
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.464-467
    • /
    • 1997
  • In this paper, a high precision track following control algorithm is proposed for micro electrostatic actuator considering of the application for hard disk drive. The micro electrostatic actuator proposed has nonlinear voltage-displacement characteristic in a working range of 0.8.mu.m and has uni-directional movement. Mid range reference and open-loop bias are proposed for the revision of negative position error, and inverse model for linearization.

  • PDF

A Skeletal Framework Artificial Hand Actuated by Micro Pneumatic Artificial Muscles

  • Lee, Young-Kwun;Oh, Yeon-Taek;Sung, Hak-Kyung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.36.2-36
    • /
    • 2002
  • .Developing a skeletal framework artificial hand similar to real human hand. .Developing a micro artificial muscle actuated by pneumatic power. .Building a micro pneumatic system including micro atuators and its control devices. .Building a soft driving system for Service robots. .Designning and Fabricating a multi-channel micro pneumatic valve using MEMS technology.

  • PDF

Design of 3 DOF Parallel Micro Robot (3자유도 병렬형 마이크로 로봇 설계)

  • 나흥열;이병주;서일홍;김희국
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.429-429
    • /
    • 2000
  • Micro positioning mechanism is the key technology in many fields, such as scanning electron microscopy (SEM), x-ray lithography, mask alignment and micro-machining. In the paper, a 3DOF parallel-type micro-positioning mechanism is proposed. This mechanism uses piezo-actuators and Flexure hinge to control x, y and $\theta$ motion. It is shown both analytically and numerically that 2 DOF flexure hinge model was better precision than 1 DOF flexure hinge design.

  • PDF

A Design of Impact Control Device for High-speed Mounting of Micro-Chips (소형 칩의 고속 표면실장을 위한 충격력 제어 장치의 설계)

  • 이덕영;김병만;심재홍;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.121-121
    • /
    • 2000
  • This paper presents a design of macro-micro system for high-speed mounting of micro-chips. A macro motion device is driven by DC servomotor and ball screw mechanism. To obtain fast response, a micro motion device utilizes a precision elector magnetic actuator In order to reduce peak impact force, We evaluate the design parameters that have an effect on it. And a characteristic of response is simulated using PID controller in velocity and force control.

  • PDF

Intelligent User Interface for Teleoperated Microassembly

  • Song, Eun-Ha;Kim, Deok-Ho;Kim, Kyunghwan;Lee, Jaehoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.168.2-168
    • /
    • 2001
  • Generally, operators suffer much difficulty in manipulating micro-nano-sized objects without assisting of human interface, due to the scaling effects in micro/nano world. Thus, the micromanipulation system based on the teleoperation techniques enables operators to manipulate the micro objects easily by transferring both human motion and manipulation skills to the micromanipulator. In teleoperated microassembly, it is necessary to provide a useful user interface for facilitating micro assembly task executed by human operators. In this paper, Intelligent User Interface (UI) for teleoperated microassembly is proposed. The proposed intelligent UI improves task performance by teleoperated micromanipulation as well as guides operators to succeed in desirable ...

  • PDF

Feature Extraction for Vision Based Micromanipulation

  • Jang, Min-Soo;Lee, Seok-Joo;Park, Gwi-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.41.5-41
    • /
    • 2002
  • This paper presents a feature extraction algorithm for vision-based micromanipulation. In order to guarantee of the accurate micromanipulation, most of micromanipulation systems use vision sensor. Vision data from an optical microscope or high magnification lens have vast information, however, characteristics of micro image such as emphasized contour, texture, and noise are make it difficult to apply macro image processing algorithms to micro image. Grasping points extraction is very important task in micromanipulation because inaccurate grasping points can cause breakdown of micro gripper or miss of micro objects. To solve those problems and extract grasping points for micromanipulation...

  • PDF

Analysis of microsurgery task for developing microsurgery manipulator (미세수술용 매니퓰레이터의 개발을 위한 미세수술 작업 분석)

  • 송세경;김완수;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.1631-1634
    • /
    • 1997
  • Since surgery is usually a difficult task because of physiological tremor, eye strain, and tremor, contagious and radioactive hazard, it is necessary to develop micro-surgery telerobotic system using improved tools suitable for their specific tasks. Nowadays the growth of interest on microsurgery and medical applications of robotics has been so rapid. But the medical robots are only practical applications of the industrial robots. This paper identifies five general areas of advanced microsurgery based on the current technological background and expertise, and analyzes the motion, tool and accuracy with respect to microsurgery task, and proposed the criteria to evaluate micro-surgical manipulator. The analysis of microusrgery can be heplful to clarify some basic concept and design of micro-surgical manipulators. With these data we will alos propose an efficient in-parallel-platform manipulator having special kinematic structrue structure suitable for microsurgery.

  • PDF

Development of Auto Tracking Total Station for Unmanned Remote Surveying of Micro Tunneling with Curved Courses (곡선경로를 가지는 마이크로 터널링의 무인 원격 측량을 위한 자동 추미식 거리 및 각도 측정 시스템)

  • 이진이;김정훈
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.11
    • /
    • pp.891-898
    • /
    • 2003
  • Unmanned remote survey system is proposed to measure distance and angle of the present position of micro-tunneling machine from any starting point of entrance. Cross type linear LED that can be controlled remotely is attached to the tunneling machine. Range finder and angle measuring devise fixed to internal of the pipe can scan the center of LED. Distance and angle measuring devises are disposed in the measurable position of the pipe, then the present position of tunneling machine can be calculated automatically from the measurements.