• 제목/요약/키워드: Micro Pump

검색결과 186건 처리시간 0.036초

발전 계획에서 순환 물 펌프 고장 분석 (Failure Analysis of Circulating Water Pump Shaft in Power Plant)

  • Lee, Jaehong;Jung, Nam-gun
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제7권1호
    • /
    • pp.125-128
    • /
    • 2021
  • This paper presents the root cause failure analysis of the circulating water pump in the 560 MW thermal power plant. A fractured austenitic stainless-steel shaft operated for 24 years was examined. Fracture morphology was investigated by micro and macro-fractographic analysis. The metallurgical analyses including chemical analysis, metallography and hardness testing were performed. The analysis reveals that the pump shaft was fractured due to the reverse bending load with combination of rotating bending load. Corrective actions for plant operator was recommended based on the analysis.

Effect of Internal Flow in Symmetric and Asymmetric Micro Regenerative Pump Impellers on Their Pressure Performance

  • Horiguchi, Hironori;Matsumoto, Shinji;Tsujimoto, Yoshinobu;Sakagami, Masaaki;Tanaka, Shigeo
    • International Journal of Fluid Machinery and Systems
    • /
    • 제2권1호
    • /
    • pp.72-79
    • /
    • 2009
  • The effect of symmetric and asymmetric micro regenerative pump impellers on their pressure performance was studied. The shut off head of the pump with the symmetric impeller was about 2.5 times as that with the asymmetric impeller. The computation of the internal flow was performed to clarify the cause of the increase of the head. It was found that the contribution of the angular momentum supply was larger than that of shear stress for the head development in both cases. The larger head and momentum supply in the case of the symmetric impeller were caused by larger recirculated flow rate and larger angular momentum difference between the inlet and outlet to the impeller. The larger recirculated flow rate was caused by smaller pressure gradient in the direction of recirculated flow. The decrease of the circumferential velocity in the casing was attributed to the smaller local flow rate in the casing.

VALVELSS 압전펌프 진동 해석 및 특성 (Vibration analysis of characteristics and valveless Type Piezoelectric micro-pump)

  • 임종남;오진헌;임기조;김현후
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.185-185
    • /
    • 2009
  • Micropump is very useful component in micro/nano fluidics and bioMEMS applications. Using the flexural vibration mode of PZT bar, a piezopump is successfully made. The PZT bar is polarized with thickness direction. The proposed structure for the piezo-pump consists of an input and an output port, piezoelectric ceramic actuator, actuator support, diaphragm. The traveling flexural wave along the bar is obtained by dividing two standing waves which are temporally and spatially phase shifted by 90 degrees from each other. Fluid is drawn into a forming chamber, eventually the forming chamber closes trapping the fluid therein. The finite elements analysis on the proposed pump model is carried out to verify its operation principle and design by the commercial FEM software. Components of piezopump were made, assembled, and tested to validate the concepts of the proposed pump and confirm the simulation results. The performance of the proposed piezopump the highest pressure level of 83.4kHz.

  • PDF

미소 수중 생물체 이송용 단판 디스크 펌프의 성능 실험 (Experiments on Single-Disk Pumps for the Transportation of Micro-scale Water Life)

  • 장젠칭;장세명;정용훈;양재삼
    • 한국유체기계학회 논문집
    • /
    • 제14권6호
    • /
    • pp.18-25
    • /
    • 2011
  • A boundary-layer pump with a single disk has been experimented to obtain its characteristic curve by changing the impeller of a centrifugal pump to a single disk. The primary objective to use of these types of pumps is to avoid hurting water life during transportation unnecessarily. The change of impeller should degrade the performance of pump, so we used the method to increase the roughness on the disk with sandpaper and mesh. The enhancement of shear force from the rotation of disk to the internal flow brought an augmentation of momentum transport, and the characteristics were far improved from the original single-disk pump without decreasing the survival rate of water life in the case of Pseudobagrus fulvidraco (bullhead fish). However, in the case of Artemia cyst (zooplankton), the survival rate was very degraded due to the micro scale smaller than turbulent eddy size. The result of this study could be used for the design of transportation and bio-filtering of water lying on a specific bandwidth of its scale of size.

암모기 흡혈과정에 대한 실험적 연구 (Experimental research on blood sucking phenomena of a female mosquito)

  • 김보흠;이정엽;이상준
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.105-106
    • /
    • 2008
  • As a carrier of malaria and sneak of blood, mosquitoes are an unpleasant insect. However, there are several unknown natural secretes related with mosquitoes. Among them, we focused on the blood sucking process of a female mosquito. The main objective of this study is to understand the mosquito's blood sucking mechanism that can be used to resolve the problem encountered in the injection or transport of infinitesimal biological fluids in a micro-chip. At first, the velocity fields of blood-sucking flow in a proboscis were measured using a micro-particle image velocimetry (PIV) technique. The velocity signals of flow in the proboscis show periodic variation. This seems to be resulted from the beating of the pharyngeal pump which works as driving power. To analyze the pumping mechanism, the temporal variation of the pharyngeal pump was visualized using the synchrotron X-ray micro-imaging technique. The volume variation was estimated by the help of digital image processing techniques. Once the main mechanism of blood sucking process was found, a effective micro-pumping system with high efficiency would be developed in near future.

  • PDF

Simulation을 통한 미세 PUMP 내에서의 유체흐름 연구 (A simulation study on fluid flowing in micro pump)

  • 김용천;류근걸
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2002년도 추계학술발표논문집
    • /
    • pp.163-166
    • /
    • 2002
  • 21세기에 가장 시급하게 확보되어야 하는 기술은 BT (Biotechnology)와 NT(Nano technology)를 접목시키는 기술이다. 특히, 이들을 종합한 MEMS에 관한 연구는 가장 광범위한 분야에서 활발하게 이루어지고 있어 그 기술적 가치가 점차 중요시되고 있다 본 연구는 Simulation을 통하여 Bio-MEMS기술에서 사용되는 미세Pump 내에서의 유체흐름을 Fluent 프로그램을 사용하여 알아보고자 하였다. 즉, 미세Pump 내로 유체가 흐를 경우, 유체의 압력변화나 온도 변화 및 Model에 따른 유동의 흐름을 관찰하여 미세pump 내에서의 최적의 외부조건과 최적의 Pump모델을 알아보고자 실험하였다. 유동의 흐름을 조사해 본 결과 Chamber의 유무에 따라 압력과 온도의 변화를 관찰할 수 있었다. Chamber가 있는 경우 압력의 변화가 적었고 온도의 변화 또한 적었다. 따라서 Chamber가 있는 Pump가 유체의 흐름에 영향을 적게 줌을 알 수 있었으며 이는 Chamber가 있는 Pump를 설계하는 것이 필요하다고 할 수 있다.

진행파 여진에 의한 굴곡 신축진동을 이용하는 압전 펌프 (A piezoelectric pump using extensional vibration of lateral surface by traveling wave)

  • 오진헌;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.322-322
    • /
    • 2010
  • In this paper, we propose a novel type valveless micro-pump that uses extensional vibration mode of traveling wave as a volume transporting means for solving some problems about check valves, essential parts of usual pumps. The proposed pump consists of two piezoelectric ceramic rings and a metal body located in the middle of them respectively. Because the drift of bended surface that results from the traveling wave excitation controls the fluid flow, check valves are not needed in this pump model. In accordance with the variation of the pump body dimension, we analyzed the vibration displacement characteristics of pump model, determined the optimal design condition, fabricated the prototype pump from the analysis results and evaluated its efficiency.

  • PDF

네트워크 기반 유도전동기 제어를 위한 고성능 LonWorks 제어모듈 개발 (Development of High Performance LonWorks Fieldbus Control Modules for Network-based Induction Motor Control)

  • 김중곤;홍원표
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.319-324
    • /
    • 2005
  • The interface between host processor and the ShortStack Micro Server may be a Serial Communication Interface(SCI). The LonWorks control module with a high performance is developed, which is composed of the 8 bit PIC Microprocessor for host processor and the smart neuron chip for the ShoretStack Micro Server. This intelligent control board is verified as proceeding the various function tests from experimental system with an boost pump and inverter driving systems. It is also confirmed that the developed control module provides stably 0-10VDC linear signal to the input signal of inverter driving system for varying the induction motor speed. Thus, the experimental results show that the fabricating intelligent board carried out very well the various functions in the wide operating ranges of boost pump system. This developed control module expect to apply to industrial fields to require the comparatively exact control and monitoring such as multi-motor driving system with inverter, variable air volume system and the boost pump water supply systems.

  • PDF

밸브레스 연동(連動) 압전펌프의 설계 및 특성 (Design of valveless type peristaltic micro-pump)

  • 오진헌;정의환;임종남;임기조;송재성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1301_1302
    • /
    • 2009
  • Recently, there has been increased incessantly an interest in research area on micro-fluidic pump for electronic and biological applications. The proposed pump takes an unobtrusive operation into the simple displacing mechanism using peristaltic traveling waves without the physical moving valves. And, this piezopump makes up a panel type design. The ATILA simulation was performed to estimate the operating frequency of the vibrating wave mode, to optimize the design conditions of piezopump such as structure, elastic body material, piezoelectric ceramics, and to analyze the distribution of vibration displacement. The best measured value of the pumping rate is about $118{\mu}l$/min under the following parameters : 4-wave mode, 50kHz operating frequency, $200V_p$.

  • PDF

자기변형 박막을 이용한 마이크로 펌프의 제작과 시험 (Fabrication and Test of a Micro Pump with a Magnetostrictive diaphragm)

  • 서지훈;정옥찬;양상식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1017-1019
    • /
    • 1998
  • In this paper, the fabrication of a micropump with two giant magnetostrictive films of Sm-Fe and Tb-Fe is presented. The pump consist of one silicon wafer and one cover glass. The micropump consists of an actuator diaphragm, a paired nozzle and diffuser, and two through holes. The Structure of the micropump is fabricated by the chemical vapor deposition, the etching and the sputtering of the magnetostrictive films. The deflection of the actuator measured diaphragm is measured by using the laser vibrometer and the flow rate of the micro pump is observed by using a video microscope.

  • PDF