• 제목/요약/키워드: Micro Injection

검색결과 452건 처리시간 0.025초

A Vision Based Bio-Cell Recognition for Biomanipulation with Multiple Views

  • Jang, Min-Soo;Lee, Seok-Joo;Lee, Ho-Dong;Kim, Byung-Kyu;Park, Jong-Oh;Park, Gwi-Tae
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2435-2440
    • /
    • 2003
  • Manipulation of the nano/micro scale object has been a key technology in biology as the sizes of DNA, chromosome, nucleus, cell and embryo are within such order. For instance, for embryo cell manipulation, the cell injection is performed manually. The operator often spends over a year to carry out a cell manipulation project. Since the typical success rate of such operation is extremely low, automation of such biological cell manipulation has been asked. As the operator spends most of his time in finding the position of cell in the Petri dish and in injecting bio-material to the cell from the best orientation. In this paper, we propose a new strategy and a vision system, by which one can find, recognize and track nucleus, polar body, and zona pellucida of the embryo cell for automatic biomanipulation. The deformable template matching algorithm has been used in recognizing the nucleus and polar body of each cell. Result suggests that it outperforms the conventional methods.

  • PDF

Analysis on Tracking Schedule and Measurements Characteristics for the Spacecraft on the Phase of Lunar Transfer and Capture

  • Song, Young-Joo;Choi, Su-Jin;Ahn, Sang-Il;Sim, Eun-Sup
    • Journal of Astronomy and Space Sciences
    • /
    • 제31권1호
    • /
    • pp.51-61
    • /
    • 2014
  • In this work, the preliminary analysis on both the tracking schedule and measurements characteristics for the spacecraft on the phase of lunar transfer and capture is performed. To analyze both the tracking schedule and measurements characteristics, lunar transfer and capture phases' optimized trajectories are directly adapted from former research, and eleven ground tracking facilities (three Deep Space Network sties, seven Near Earth Network sites, one Daejeon site) are assumed to support the mission. Under these conceptual mission scenarios, detailed tracking schedules and expected measurement characteristics during critical maneuvers (Trans Lunar Injection, Lunar Orbit Insertion and Apoapsis Adjustment Maneuver), especially for the Deajeon station, are successfully analyzed. The orders of predicted measurements' variances during lunar capture phase according to critical maneuvers are found to be within the order of mm/s for the range and micro-deg/s for the angular measurements rates which are in good agreement with the recommended values of typical measurement modeling accuracies for Deep Space Networks. Although preliminary navigation accuracy guidelines are provided through this work, it is expected to give more practical insights into preparing the Korea's future lunar mission, especially for developing flight dynamics subsystem.

침액식 세정설비의 마이크로버블을 이용한 철강산업 공정의 산세조 발생 염화수소 제거 (Hydrochloric Acid Gas Removal from Iron and Steel Industry Using Micro-bubbles of a Dip Injection Wet Scrubber System)

  • 김예진;정재억;정용준
    • 한국습지학회지
    • /
    • 제17권1호
    • /
    • pp.75-79
    • /
    • 2015
  • 대기오염물질인 염화수소의 배출 규제가 2ppm으로 강화됨에 따라 기존의 제철공장 습식세정 장치에 DIWS 시스템이 도입되었다. 침액식 스크러버 시스템으로 제철공정에서 발생되는 염화수소를 처리하기 위한 파일럿 연구를 수행하였다. DIWS 시스템의 운전에 따른 응축수 pH는 연돌에서 6.0으로 증가하였다. 산세 Fume 정제설비의 평균 유입 염화수소는 13.3ppm, 평균 배출가스는 0.43ppm, 평균 제거율은 96.9%로 나타났다. TMS 장치로 장기간 측정한 데이터를 비교하였을 때 DIWS 장치는 안정적인 제거율을 나타냈지만, TMS의 type별 데이터 불균일 현상이 관찰되었다.

박형 도광판의 음각, 양각 마이크로 패턴 성형성에 관한 연구 (Study on the gate cutting of light guiding plate for mobile using quenching element)

  • 황철진;김종선;민인기;김종덕;윤경환
    • Design & Manufacturing
    • /
    • 제2권5호
    • /
    • pp.1-4
    • /
    • 2008
  • LCD-BLU (Liquid Crystal Display - Back Light Unit) is one of kernel parts of LCD unit and it consists of several optical sheets(such as prism, diffuser and protector sheets), LCP (Light Guide Plate), light source (CCFL or LED) and mold frame. The LGP of LCD-BLU is usually manufactured by forming numerous dots with $50-200{\mu}m$ in diameter on it by erosion method. But the surface of the erosion dots of LGP is very rough due to the characteristics of the erosion process during the mold fabrication, so that its light loss is high along with the dispersion of light into the surface. Accordingly, there is a limit in raising the luminance of LCD-BLU. Especially, the negative and positive micro-lens pattern fabricated by modified LiGA with thermal reflow process was applied to the optical design of LGP.

  • PDF

Dynamic SPME를 이용한 공기 중 지방산 분석 (Analysis of Volatile Fatty Acids in Air by Dynamic SPME)

  • 유미선;양성봉;하남기
    • 한국환경과학회지
    • /
    • 제19권12호
    • /
    • pp.1447-1454
    • /
    • 2010
  • In this study, the detection limits of lower fatty acids in air were investigated by using Dynamic SPME(Solid Phase Micro-Extraction), i.e. improved Head Space - SPME method(HS-SPME). This Dynamic SPME, called SPDE(Solid Phase Dynamic Extraction), is the analytical method for volatile compounds in air with the extraction by using a stainless steel needle of which inner surface is coated with adsorption material and following the gas chromatographic analysis by inserting the needle into a injection port of GC and subsequently, desorption of the volatile compounds into a gas-chromatographic column. Extraction was carried out by passing the sample air through the needle with a suction pump which has been used for a detection tube. The result of measurement for the 6 lower fatty acids showed that the detection limits ranged from 0.10 ppm to 0.44 ppm and the linear correlation coefficients were over 0.99. Relative standard deviations obtained from 5 analytical repetition of a ca. 1.6 ppm standard mixture were in the range of 1.87%~2.47%. This method has been shown to be a adequate for the measuring C2~C5 fatty acids in air in the concentrations of over several hundreds ppb.

RTM 공정에 의한 탄소/페놀 복합재료의 제조 및 특성 분석 (Preparation and Characterization of Carbon/Phenol Composite by RTM Process)

  • 진다영;이현재;임성찬;김연철;윤남균;이승구
    • 한국염색가공학회지
    • /
    • 제28권4호
    • /
    • pp.239-245
    • /
    • 2016
  • In this study, carbon/phenol composites were prepared from carbon fiber preform and phenol resin by RTM(resin transfer molding) process. And changes in the properties of the composite according to the pre-treatment of phenol resin was mainly studied. RTM process conditions were deduced from viscosity and thermal analysis of phenol resin which were rheometer and thermogravimetric analyzer(TGA). RTM process was performed under various injection and molding temperature. Characterization of the prepared C/P composites were evaluated by various analysis. Morphology of composites was analyzed by Micro-CT(MCT), Mechanical properties of composites were measured through the flexural properties. As results, volatile impurities of phenol resin were effectively removed at resin pre-treatment temperature of $100^{\circ}C$ and composite was sufficiently cured at molding temperature of $180^{\circ}C$.

EPMA를 이용한 ZnO 세라믹 바리스터 입계의 원소분포와 열화특성 분석 (Analysis of Element distribution and Degradation Characteristics in the grain boundary of ZnO Ceramic Varistors with EPMA)

  • 소순진;김영진;박영순;박춘배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 전자세라믹스 센서 및 박막재료 반도체재료 일렉트렛트 및 응용기술
    • /
    • pp.64-67
    • /
    • 2000
  • Element distribution analysis and degradation characteristics of the ZnO varistors fabricated at the ambient sintering-process is investigated in this study. ZnO varistors made of Matsuoka's composition were fabricated by standard ceramic techniques. The ambient sintering-process is performed at the special electrical-furnace which is equipped with the vacuum system. The Gases of injection at sintering- process were oxygen, air, nitrogen and argon respectively. Element and quantitative analysis in the microstructure of ZnO varistors made use of EPMA equipment. Degradation characteristics were showed by DC degradation tests at $115{\pm}2\;^{\circ}C$ for period up to 13 h. From above analysis, it is found that at the DC degradation test the ZnO varistor sintered in oxygen atmosphere showed the excellent prop properties among them and these results could be explain by element and quantitative analysis in ZnO microstructure.

  • PDF

An Injection-Locked Based Voltage Boost-up Rectifier for Wireless RF Power Harvesting Applications

  • Lee, Ji-Hoon;Jung, Won-Jae;Park, Jun-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2441-2446
    • /
    • 2018
  • This paper presents a radio frequency-to-direct current (RF-to-DC) converter for special RF power harvesting application at 915 MHz. The major featured components of the proposed RF-to-DC converter is the combination of a cross-coupled rectifier and an active diode: first, the cross-coupled rectifier boosts the input voltage to desired level, and an active diode blocks the reverse current, respectively. A prototype was implemented using $0.18{\mu}m$ CMOS technology, and the performance was proven from the fact that the targeted RF harvesting system's full-operation with higher power efficiency; even if the system's input power gets lower (e.g., from nominal 0 to min. -12 dBm), the proposed RF-to-DC converter constantly provides 1.47 V, which is exactly the voltage level to drive follow up system components like DC-to-DC converter and so on. And, maximum power conversion efficiency is 82 % calculated from the 0 dBm input power, 2.3 mA load current.

레이저 펄스 에너지를 이용한 무통증 마이크로젯 약물전달시스템 (Painless Microjet Injector Using Laser Pulse Energy)

  • 여재익;한태희;하정무
    • 대한기계학회논문집B
    • /
    • 제35권5호
    • /
    • pp.547-550
    • /
    • 2011
  • 레이저 기반의 무바늘 액체 약물전달장치는 계속해서 개발되어왔다. 레이저 빔이 고무 챔버 내부의 액체에 모이게 된다. 초점이 맞춰진 레이저 빔은 공기방울을 생성시키고 급격히 팽창하게 된다. 밀봉된 챔버 안쪽에서의 급격한 부피변화는 액체약물을 마이크로 노즐을 통해 빠르게 밀어내어 마이크로 약물젯을 생성한다. 노즐의 출구지름은 100 ${\mu}m$ 이하이며 본 연구팀은 생성된 마이크로 약물젯의 속도가 인체의 연조직으로 침투시키기에 충분함을 확인하였다. 이 실험에서는 사람의 혈전을 모사한 무게 비 5%의 젤라틴 수용액을 냉각시킨 샘플과 돼지 지방층을 사용하여 침투실험을 수행하였다.

방전에너지 제어용 외부 커패시터를 이용한 대기압 마이크로 플라즈마 소스 개발 (Development of a Microplasma Source under Atmospheric Pressure using an External Ballast Capacitor)

  • 하창승;이제현;손의정;박차수;이호준
    • 조명전기설비학회논문지
    • /
    • 제27권6호
    • /
    • pp.31-38
    • /
    • 2013
  • A pulse driven atmospheric plasma jet controlled by external ballast capacitor is developed. Unlike the most commonly use DBD sources, the proposed device utilizes bare metal electrode. The discharge energy per pulse can precisely be determined by changing voltage and capacitance of the ballast capacitor. It is shown that the device can provide wide range of plasma, from stable glow mode to near arc state. Current-voltage waveforms, optical emission spectra and discharge images are investigated as a function of an injection energy. The OES shows that He and oxygen lines are increased as a function of the external ballast capacitor. Ozone and rotational temperature have similar tendency with a power consumption. The feeding gas is He and the applied DC voltage is from 400V to 800V when the gap distance is $500{\mu}m$.