• 제목/요약/키워드: Micro Glass Bubble

검색결과 10건 처리시간 0.028초

새로운 기포동력 마이크로펌프 제작 및 실험 (Novel Fabrication and Testing of a Bubble-Powered Micropump)

  • 정정열;곽호영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1196-1200
    • /
    • 2004
  • Micropump is very useful component in micro/nano fluidics and bioMEMS applications. In this study, a bubble-powered micropump was fabricated and tested. The micropump consists of two-parallel micro line heaters, a pair of nozzle-diffuser flow controller and a 1 mm in diameter, 400 ${\mu}m$ in depth pumping chamber. The two-parallel micro line heaters with 20 ${\mu}m-width$ and 200 ${\mu}m-length$ were fabricated to be embedded in the silicon dioxide layer of a wafer which serves as a base plate for the micropump. The pumping chamber, the pair of nozzle-diffuser unit and microchannels including the liquid inlet and outlet port were fabricated by etching through another silicon wafer. A glass wafer (thickness of $525{\pm}15$ ${\mu}m$) having two holes of inlet and outlet ports of liquid serve as upper plate of the pump. Finally the silicon wafer of the base plate, the silicon wafer of pumping chamber and the glass wafer were aligned and bonded (Si-Si bonding and anodic bonding). A sequential photograph of bubble nucleation, growth and collapse was visualized by CCD camera. Clearly liquid flow through the nozzle during the period of bubble growth and slight back flow of liquid at the end of collapsing period can be seen. The mass flow rate was found to be dependent on the duty ratio and the operation frequency. As duty ratio increases, flow rate decreases gradually when the duty ratio exceeds 60%. Also as the operation frequency increases, the flow rate of the micropump decreases slightly.

  • PDF

100㎛급 글라스 버블 혼입 시멘트계 초경량 무기 단열재의 단열 및 난연특성 (Thermal Insulation and Flame Retardant Properties of Cement Based Super Light-weight Inorganic Thermal Insulation using 100㎛ Grade Glass Bubble)

  • 손배근;송훈
    • 한국건설순환자원학회논문집
    • /
    • 제9권4호
    • /
    • pp.642-649
    • /
    • 2021
  • 건축물의 에너지 절약기준이 강화되면서 외단열 공법의 적용과 단열재 두께가 증가하고 있다. 유기계 단열재는 시공성, 경제성 등 시공비용 절감 효과와 뛰어난 단열성능을 가지고 있다. 하지만, 유기계 단열재 특성상 열에 매우 취약하므로 화재 발생 시 급격한 화재확산과 유독가스 발생으로 심각한 피해가 발생한다. 무기계 단열재는 기본적으로 불연성능을 가지나 무겁고 유기계 단열재에 비해 단열성능이 떨어진다. 글라스 버블은 소다 라임 보로실리케이트 유리로 밀도가 매우 낮고, 내부가 비어 있는 구형의 입자로 볼베어링 효과로 유동성이 개선된다. 또한, 무기계 단열재에 혼입하여 사용할 경우 밀도와 단열성능이 개선된다. 본 연구는 시멘트계 재료와 글라스 버블을 혼합하여 무기 단열재를 제조하였고 단열, 난연 및 불연성능을 평가하였다. 연구 결과, 글라스 버블의 혼입률이 증가할수록 열린 기공을 형성하고 있으나, 기공 및 셀 벽에 분포됨에 따라 충분한 단열성능을 보인다. 또한, 글라스 버블의 혼입률은 10% 이하로 사용하는 것이 바람직하다.

An Experimental Study on the Improvement of Microscopic Machinability of Glass using the Discharging Peak Control Techniques in the Electrochemical Discharge Machining Technologies

  • Chang, In-Bae;Kim, Nam-Hyeock;Kim, Byeong-Hee;Kim, Heon-Young
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.315-316
    • /
    • 2002
  • Electrochemical discharge machining is a very recent technique for non-conducting materials such as ceramics and glasses. ECDM is conducted in the NaOH solution and the cathode electrode is separated from the solution by $H_2$ gas bubble. Then the discharge is appeared and the non-conductive material is removed by spark and some chemical reactions. In the ECDM technology, the $H_2$ bubble control is the most important factor to stabilize the discharging condition. In this paper, we proposed the discharge peak monitoring/ discharging duty feedback algorithms for the discharge stabilization and the feasibility of this algorithm is verified by various pattern machining in the constant preload conditions for the cathode electrode.

  • PDF

An Experimental Study on the Improvement of Microscopic Machinability of Glass using the Discharging Peak Control Techniques in the Electrochemical Discharge Machining Technologies

  • Chang, In-Bae;Kim, Nam-Hyeock;Kim, Byeong-Hee;Kim, Heon-Young
    • KSTLE International Journal
    • /
    • 제3권2호
    • /
    • pp.95-100
    • /
    • 2002
  • Electrochemical discharge machining is a very recent technique for non-conducting materials such as ceramics and glasses. ECDM is conducted in the NaOH solution and the cathode electrode is separated from the solution by H$_2$ gas bubble. Then the discharge is appeared and the non-conductive material is removed by spark and some chemical reactions. In the ECDM technology, the H$_2$ bubble control is the most important factor to stabilize the discharging condition. In this paper we proposed the discharge peak monitoring/discharging duty feedback algorithms fur the discharge stabilization and the feasibility of this algorithm is verified by various pattern machining in the constant preload conditions for the cathode electrode.

마이크로 복수 분지관에서의 버블거동에 관한 연구 (Bubble Behavior in a Micro-Multi-Branched-Channel)

  • 김경천;류건호
    • 한국가시화정보학회지
    • /
    • 제4권2호
    • /
    • pp.32-36
    • /
    • 2006
  • Recently there are many researches about single flow and two-phase flow phenomena in the mini and microchannel. But from this result the principle in the microchannel was not explained clearly. In this paper two-phase flow pattern was visualized in the micro-multi-branched-channel using a high speed camera. Microchannel was fabricated with PDMS and glass slide. The velocity profile was obtained by a Micro PIV. Then flow boiling at the near inlet area was occurred and vapor was moved in the micro-multi-branched-channel.

  • PDF

두 개의 챔버를 갖는 마이크로 버블펌프의 개발 (Development of having double-chamber in micro-bubble pump)

  • 최종필;박대섭;반준호;김병희;장인배;김헌영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1186-1190
    • /
    • 2003
  • In this paper, a valveless bubble-actuated fluid micropump was has been developed and its performance was tested. The valveless micropump consists of the lower plate, the middle plate, the upper plate and a resistive heater. The lower plate includes the nozzle-diffuser elements and the double-chamber. Nozzle-diffuser elements and a double-chamber are fabricated on the silicon wafer by the DRIE(Deep Reactive Ion Etching) process. The lower plate also has inlet/outlet channels for fluid flow. The middle plate is made of glass and plays the role of the diaphragm. The chamber in the upper plate is filled with deionized water, and which contacts with the resistive heater. The resistive heater is patterned on a silicon substrate by Ti/Pt sputtering. Three plates and the resister heater are laminated by the aligner and bonded in the anodic bonder. Since the bubble is evaporated and condensed periodically in the chamber, the fluid flows from inlet to outlet with respect to the diffusion effect. In order to avoid backflow, the double chamber system is introduced. Analytical and experimental results show the validity of the developed double-chamber micropump.

  • PDF

탄소나노튜브 및 마이크로 글래스 버블 기반 열전 복합재 (Thermoelectric Composites Based on Carbon Nanotubes and Micro Glass Bubbles)

  • 강구혁;성광원;김명수;김인국;방인철;박형욱;박영빈
    • Composites Research
    • /
    • 제28권2호
    • /
    • pp.70-74
    • /
    • 2015
  • 본 논문에서는 탄소나노튜브(CNT)와 마이크로 글래스 버블(GB)을 포함한 폴리아마이드 6(PA6) 복합재의 열전 특성을 다뤘다. 복합재에 포함된 GB은 복합재 내에서 큰 공간을 차지하게 되는데, 이때 CNT는 GB가 없는 공간으로 밀려나면서 고밀도로 격리된(segregated) 네트워크를 형성한다. CNT의 분산을 위해, 소니케이션(Sonicatoin)으로 CNT를 분산시킨 PA6, 포름산 용액을 증류수를 이용하여 응고시킨 후 압축성형하여 복합재 판을 제조하였다. 복합재 판의 열전성능을 평가하기 위해서 열전도도, 전기전도도, 제벡계수(Seebeck coefficient) 등을 측정하였고, 최고 0.016의 성능지수를 얻었다.

마이크로 혼합기와 반응기로 구성된 DNA 결찰용 바이오칩에 관한 연구 (A Study About Biochip Combined with Micro Mixer and Reactor for DNA Ligation)

  • 강도형;안유민;황승용
    • 대한기계학회논문집A
    • /
    • 제32권8호
    • /
    • pp.624-632
    • /
    • 2008
  • In this research, we developed new PDMS-glass based microbiochip consisted of the micromixer and microreactor for DNA ligation. The micromixer was composed of a straight channel integrated with nozzles and pillars, and the microreactor was composed of a serpentine channel. We coated the PDMS chip surface with the 0.25wt.% PVP solution to prevent the bubble generation which was caused by the hydrophobicity of the PDMS. The new micomixer was passive type and the mixing was enhanced by a convective diffusion using the nozzle and pillar. The 10.33mm long micromixer showed the good mixing efficiency of 87.7% at 500 l/min flow rate. We could perform the DNA ligation successfully in the microbiochip, and the ligation time was shortened from 4 hours in conventional laboratory method to 5 min in the microbiochip.

Raman Microscope를 이용한 진사 유약 발색 특성 분석 (Analysis of the Coloration Characteristics of Copper Red Glaze Using Raman Microscope)

  • 어혜진;이병하
    • 한국세라믹학회지
    • /
    • 제50권6호
    • /
    • pp.518-522
    • /
    • 2013
  • This study investigatesthe coloration mechanism by identifying the factor that affects thered coloration of copper red glazesin traditional Korean ceramics. The characteristics of the reduction-fired copper red glaze's sections are analyzed using an optical microscope, Raman spectroscopy, scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDX). The sections observed using an optical microscope are divided into domains of surface, red-bubble, and red band. According to the Raman micro spectroscopy analysis results, the major characteristic peak is identified as silicate in all three domains, and the intensity of $Cu_2O$ increases toward the red band. In addition, it is confirmed that the most abundant CuO exists in the glaze bubbles. Moreover, CuO and $Cu_2O$ exist as fine particles in a dispersed state in the surface domain. Thus, Cu combined with oxygen is distributed evenly throughout the copper red glaze, and $Cu_2O$ is more concentrated toward the interface between body and glaze. It is also confirmed that CuO is concentrated around the bubbles. Therefore, it is concluded that the red coloration of the copper red glaze is revealed not only through metallic Cu but also through $Cu_2O$ and CuO.

통합형 오일 정제 시스템의 개발 (Development of an Integrated Oil Purification System)

  • 홍성호;이경희;정남화
    • Tribology and Lubricants
    • /
    • 제38권4호
    • /
    • pp.121-127
    • /
    • 2022
  • This study presents the development of an integrated oil purification system consisting of moisture removal, oil flushing, and oil filtering devices. In this system, the oil flushing device is combined with a micro-bubble generator. Oil purification is necessary for ensuring the high performance of the lubricant through the efficient removal of contaminants and thus enables good maintenance of mechanical systems. The developed purification system removes moisture, varnish, and solid particles. Moreover, during oil purification, the oil flushing device separates foreign materials and contaminants remaining in the lubricating oil piping or mechanical systems. The microbubble generator, which is combined with the oil flushing device, can separate harmful contaminants, such as sludge, wear particles, and rust, from piping or lubrication systems through the cavitation effect. Moisture is removed using a double high-vacuum chamber, while sludge and varnish are removed via electro-absorption using a high-voltage generator. Additionally, the total maintenance cost of the system is reduced through the use of domestically fabricated cartridge filters composed of glass fiber and cellulose. The heater, which maintains the temperature of the lubricant at 60℃, can process 41,000 L of lubricant simultaneously. Multiple tests confirmed that the proposed integrated purification system exhibits good performance in oil flushing and removal of water and varnish.