• Title/Summary/Keyword: Micro Flow Control

Search Result 173, Processing Time 0.031 seconds

A Study About PDMS-Glass Based Thermopneumatic Micropump Integrated with Check Valve (체크밸브가 달린 열공압 방식의 PDMS-유리마이크로 펌프에 관한 연구)

  • Ko, Young-June;Cho, Woong;Ahn, Yoo-Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.9
    • /
    • pp.720-727
    • /
    • 2008
  • Microfluidic single chip integrating thermopneumatic micropump and micro check valve are developed. The micropump and micorvalve are made of biocompatible materials, glass and PDMS, so as to be applicable to the biochip. By using the passive-type check valve, backward flow and fluid leakage are blocked and flow control is stable and precise. The chip is composed of three PDMS layers and a glass substrate. In the chip, flow channel and pump chamber were made on the PDMS layers by the replica molding technique and pump heater was made on the glass substrate by Cr/Au deposition. Diameter of the pump chamber is 7 mm and the width and depth of the channel are 200 and $180{\mu}m$, respectively. The PDMS layers chip and the heater deposited glass chip are combined by a jig and a clamp for pumping operation, and they are separable so that PDMS chip is used as a disposable but the heater chip is able to be used repeatedly. Pumping performance was simulated by CFD software and investigated experimentally. The performance was the best when the duty ratio of the applied voltage to the heater was 33%.

Collaborative Streamlined On-Chip Software Architecture on Heterogenous Multi-Cores for Low-Power Reactive Control in Automotive Embedded Processors (차량용 임베디드 프로세서에서 저전력 반응적 제어를 위한 이기종 멀티코어 협력적 스트리밍 온-칩 소프트웨어 구조)

  • Jisu, Kwon;Daejin, Park
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.17 no.6
    • /
    • pp.375-382
    • /
    • 2022
  • This paper proposes a multi-core cooperative computing structure considering the heterogeneous features of automotive embedded on-chip software. The automotive embedded software has the heterogeneous execution flow properties for various hardware drives. Software developed with a homogeneous execution flow without considering these properties will incur inefficient overhead due to core latency and load. The proposed method was evaluated on an target board on which a automotive MCU (micro-controller unit) with built-in multi-cores was mounted. We demonstrate an overhead reduction when software including common embedded system tasks, such as ADC sampling, DSP operations, and communication interfaces, are implemented in a heterogeneous execution flow. When we used the proposed method, embedded software was able to take advantage of idle states that occur between heterogeneous tasks to make efficient use of the resources on the board. As a result of the experiments, the power consumption of the board decreased by 42.11% compared to the baseline. Furthermore, the time required to process the same amount of sampling data was reduced by 27.09%. Experimental results validate the efficiency of the proposed multi-core cooperative heterogeneous embedded software execution technique.

Remote-controlled micro locking mechanism for plate-type nuclear fuel used in upflow research reactors

  • Jin Haeng Lee;Yeong-Garp Cho;Hyokwang Lee;Chang-Gyu Park;Jong-Myeong Oh;Yeon-Sik Yoo;Min-Gu Won;Hyung Huh
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4477-4490
    • /
    • 2023
  • Fuel locking mechanisms (FLMs) are essential in upward-flow research reactors to prevent accidental fuel separation from the core during reactor operation. This study presents a novel design concept for a remotely controlled plate-type nuclear fuel locking mechanism. By employing electromagnetic field analysis, we optimized the design of the electromagnet for fuel unlocking, allowing the FLM to adapt to various research reactor core designs, minimizing installation space, and reducing maintenance efforts. Computational flow analysis quantified the drag acting on the fuel assembly caused by coolant upflow. Subsequently, we performed finite element analysis and evaluated the structural integrity of the FLM based on the ASME boiler and pressure vessel (B&PV) code, considering design loads such as dead weight and flow drag. Our findings confirm that the new FLM design provides sufficient margins to withstand the specified loads. We fabricated a prototype comprising the driving part, a simplified moving part, and a dummy fuel assembly. Through basic operational tests on the assembled components, we verified that the manufactured products meet the performance requirements. This remote-controlled micro locking mechanism holds promise in enhancing the safety and efficiency of plate-type nuclear fuel operation in upflow research reactors.

Microfluidic Control for Biological Cell Orientation

  • Namkung, Young-Woo;Park, Jung-Yul;Kim, Byung-Kyu;Park, Jong-Oh;Kim, Jin-Oh
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2457-2460
    • /
    • 2003
  • There is a great demand to manipulate biological cell autonomously since biologist should spend much time to obtain skillful manipulation techniques. For this purpose, we propose a cell chip to control, carry, fix and locate the cell. In this paper, we focus on the cell rotator to rotate individual biological cell based on a micro fluidics technology. The cell rotator consists of injection hole and rotation well to rotate a biological cell properly. Under the variation of flow rate in injection hole, the angular velocity of a biological cell is evaluated to find the feasibility of the proposed rotation method. As a practical experiment, Zebrafish egg is employed. Based on this research, we find the possibility of non-contact rotation way that can highly reduce the damage of the biological cell during manipulation. To realize an autonomous biological cell manipulation, a cell chip with manipulation well and micro channel in this research will be utilized effectively in near future.

  • PDF

PWM Control of Hydraulic Motor Systems Using High Speed Solenoid Valves (고속응답 전자밸브에 의한 유압 모터계의 PWM 제어)

  • 김도태
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.387-392
    • /
    • 1999
  • The micro electronic control technology with developing microcomputers make great contribution to electrohydraulic control systems. The electrohydraulic pulse control simplifies in conjunction with power electronic amplifier and high speed operated solenoid valves. It is necessary to valves to convert electronic pulse signal to hydraulic pulse flow as fast as possible. This study deals with the speed control of an oil hydraulic motor operated by two way high speed solenoid valves. The valves acts as converters of electronic-pulse signals to hydraulic power. By constructing systems in which a hydraulic motor is operated by two solenoid valves, the pulse with modulation method (PWM) has adopted as the speed control of hydraulic motor systems. The static and dynamic characteristics of the systems are investigated by the experiment. It is clarify that a hydraulic motor operated PWM show good performance as a control component, achieving accurate velocity control.

  • PDF

In vivo quantification of mandibular bone remodeling and vascular changes in a Wistar rat model: A novel HR-MRI and micro-CT fusion technique

  • Song, Dandan;Shujaat, Sohaib;Zhao, Ruiting;Huang, Yan;Shaheen, Eman;Van Dessel, Jeroen;Orhan, Kaan;Velde, Greetje Vande;Coropciuc, Ruxandra;Pauwels, Ruben;Politis, Constantinus;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.50 no.3
    • /
    • pp.199-208
    • /
    • 2020
  • Purpose: This study was performed to introduce an in vivo hybrid multimodality technique involving the coregistration of micro-computed tomography (micro-CT) and high-resolution magnetic resonance imaging (HR-MRI) to concomitantly visualize and quantify mineralization and vascularization at follow-up in a rat model. Materials and Methods: Three adult female rats were randomly assigned as test subjects, with 1 rat serving as a control subject. For 20 weeks, the test rats received a weekly intravenous injection of 30 ㎍/kg zoledronic acid, and the control rat was administered a similar dose of normal saline. Bilateral extraction of the lower first and second molars was performed after 10 weeks. All rats were scanned once every 4 weeks with both micro-CT and HR-MRI. Micro-CT and HR-MRI images were registered and fused in the same 3-dimensional region to quantify blood flow velocity and trabecular bone thickness at T0 (baseline), T4 (4 weeks), T8 (8 weeks), T12 (12 weeks), T16 (16 weeks), and T20 (20 weeks). Histological assessment was the gold standard with which the findings were compared. Results: The histomorphometric images at T20 aligned with the HR-MRI findings, with both test and control rats demonstrating reduced trabecular bone vasculature and blood vessel density. The micro-CT findings were also consistent with the histomorphometric changes, which revealed that the test rats had thicker trabecular bone and smaller marrow spaces than the control rat. Conclusion: The combination of micro-CT and HR-MRI may be considered a powerful non-invasive novel technique for the longitudinal quantification of localized mineralization and vascularization.

Effect of Steam Activation Parameters on Characteristics of Pine Based Activated Carbon

  • Manocha, S.M.;Patel, Hemang;Manocha, L.M.
    • Carbon letters
    • /
    • v.11 no.3
    • /
    • pp.201-205
    • /
    • 2010
  • Activated carbons are well known as adsorbents for gases and vapors. Micro porous carbons are used for the sorption/separation of light gases, whereas, carbon with bigger pore size are applied for removal of large molecules. Therefore, the control of pore size of activated carbon plays a vital role for their use in specific applications. In the present work, steam activation parameters have been varied to control pore size of the resulting activated carbon. It was found that flow rate of steam has profound effect on both surface characteristic and surface morphology. The flow rate of steam was optimized to retain monolith structure as well as higher surface area.

Evaluation of Efficiency on Glass Precision Machining by using Abrasive Water-jet (연마재 워터젯 가공을 이용한 유리 미세 가공 성능 평가)

  • Bahk, Yeon-Kyoung;Park, Kang-Su;Kim, Hyung-Hoon;Shin, Bo-Sung;Ko, Jong-Soo;Go, Jeung-Sang
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.7
    • /
    • pp.87-93
    • /
    • 2010
  • This paper presents an evaluation of efficiency on glass precision machining by using abrasive water-jet machine. In this study, problems of conventional water-jet machining are examined experimentally and are analysized numerically. Especially, the reason of whitening on the machined surface of biochip glass is determined. It is found that the mass flow rate of abrasive input and transverse speed of water-jet are key parameters to control the direct machining of micro hole and channel on a glass substrate. Based on results of experimental analysis, possibility of direct fabrication of micro holes and channels on a glass substrate is successfully confirmed.

The crack propagation of fiber-reinforced self-compacting concrete containing micro-silica and nano-silica

  • Moosa Mazloom;Amirhosein Abna;Hossein Karimpour;Mohammad Akbari-Jamkarani
    • Advances in nano research
    • /
    • v.15 no.6
    • /
    • pp.495-511
    • /
    • 2023
  • In this research, the impact of micro-silica, nano-silica, and polypropylene fibers on the fracture energy of self-compacting concrete was thoroughly examined. Enhancing the fracture energy is very important to increase the crack propagation resistance. The study focused on evaluating the self-compacting properties of the concrete through various tests, including J-ring, V-funnel, slump flow, and T50 tests. Additionally, the mechanical properties of the concrete, such as compressive and tensile strengths, modulus of elasticity, and fracture parameters were investigated on hardened specimens after 28 days. The results demonstrated that the incorporation of micro-silica and nano-silica not only decreased the rheological aspects of self-compacting concrete but also significantly enhanced its mechanical properties, particularly the compressive strength. On the other hand, the inclusion of polypropylene fibers had a positive impact on fracture parameters, tensile strength, and flexural strength of the specimens. Utilizing the response surface method, the relationship between micro-silica, nano-silica, and fibers was established. The optimal combination for achieving the highest compressive strength was found to be 5% micro-silica, 0.75% nano-silica, and 0.1% fibers. Furthermore, for obtaining the best mixture with superior tensile strength, flexural strength, modulus of elasticity, and fracture energy, the ideal proportion was determined as 5% micro-silica, 0.75% nano-silica, and 0.15% fibers. Compared to the control mixture, the aforementioned parameters showed significant improvements of 26.3%, 30.3%, 34.3%, and 34.3%, respectively. In order to accurately model the tensile cracking of concrete, the authors used softening curves derived from an inverse algorithm proposed by them. This method allowed for a precise and detailed analysis of the concrete under tensile stress. This study explores the effects of micro-silica, nano-silica, and polypropylene fibers on self-compacting concrete and shows their influences on the fracture energy and various mechanical properties of the concrete. The results offer valuable insights for optimizing the concrete mix to achieve desired strength and performance characteristics.

Design and Analysis of IPMC Actuator-driven ZNMF Pump for Air Flow Control of MAV's Wing (IPMC 작동기로 구동되는 초소형 비행체 날개의 공기흐름 조절용 ZNMF(zero-net-mass-flux) 펌프의 예비설계 및 해석)

  • Lee, Sang-Gi;Kim, Gwang-Jin;Park, Hun-Cheol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.3
    • /
    • pp.22-30
    • /
    • 2006
  • In this paper, a systematic design method on an IPMC(ionic polymer-metal composite)-driven ZNMF(zero-net-mass-flux) pump is introduced for the flow control of an MAV's (micro air vehicle) wing. Since the IPMC is able to generate a large deformation under a low input voltage along with its ability to operate in air, and is easier to be manufactured in a small size, it is considered to be an ideal material of the actuating diaphragm. Through the numerical methods, an optimal shape of the IPMC diaphragm was found for maximizing the stroke volume. Based on the optimal IPMC diaphragm, a proto-type ZNMF pump with a slot, was designed. By using the flight speed of the MAV considered in this work, the driving frequencies(~ 40 Hz) of IPMC diaphragm, and the flow velocity through the pump's slot, the calculated non-dimensional frequency and the momentum coefficient ensure the feasibility of the designed ZNMF pump as a flow control device.