박막이 부착된 마이크로 채널 내의 유동해석 (flow analysis in Micro Channel with a Couple of Fins)

  • 정재택
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 춘계 학술대회논문집
    • /
    • pp.228-233
    • /
    • 2005
  • Two-dimensional Stokes flows through a micro channel with a couple of symmetric vertical fins are investigated. At far up- and down-stream from the fins, the plane Poiseuille flow exists in the channel. The slip boundary conditions are applied to take account of the Knudsen number effects. For the analysis, the method of eigen function expansion and collocation method are employed. By the results, the streamline patterns and pressure distributions are shown and the force exerted on the fin and the excess pressure drop due to the fins are determined as functions of the length of the fin and Knudsen number. It may be conjectured that the force and the excess pressure drop are almost independent of the Knudsen number.

  • PDF

비등열전달 향상을 위한 초소형 핀 제작공정에 관한 연구 (A Study on the microcooling Fin Fabrication Process for Enhancing Boiling Heat Transfer)

  • 유삼상;임태우;정석권;박종운
    • 수산해양교육연구
    • /
    • 제19권3호
    • /
    • pp.366-372
    • /
    • 2007
  • This paper presents the fabrication techniques of microcooling fins for microelectronics applications. The various types of cooling fins have been fabricated on the surface of a silicon wafer (4inch-N type) by using wet etching technique. The designed micro fins and micro channels are considered as an effective method for cooling microelectronics devices generating high heat flux. Further we extensively investigate the design processes fabricating micro fins and channels which can cool the heat generated from high density electronics devices.

마이크로 휜 표면의 분무냉각 열전달에 관한 실험적 연구 (Experimental Study on Spray Cooling Heat Transfer of Micro-Fins Surfaces)

  • 김영찬
    • 한국분무공학회지
    • /
    • 제14권4호
    • /
    • pp.178-183
    • /
    • 2009
  • Spray cooling heat transfer was experimentally investigated for water sprays impacting on mico-fins structured surfaces in the single phase and nucleate boiling regions. The heat transfer surfaces consist of cubic fins and triangular grooved fins. The spray produced using full cone spray nozzles, and experiments were made under the test condition of $Q=4.92{\times}10^{-6}{\sim}15.83{\times}10^{-6}\;m^3/s$, $T_f=35{\sim}55^{\circ}C$. From the experimental results, it was found that cubic fins surface had the largest heat flux enhancement relative to the smooth surface.

  • PDF

원형 단면관 내 미세 휜의 형상 변화에 따른 열.유동 특성 및 최적 형상 개발에 관한 수치 해석 (Numerical Investigation of Thermal Characteristics and Geometrical Optimization in circular tubes with micro fins)

  • 한동혁;이규정
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1113-1118
    • /
    • 2006
  • A numerical investigation of single phase heat and flow characteristics in circular tubes with a single set of spiral micro fins was performed with varying geometrical parameters like fin height, spiral angle, and number of fins. The properties of $40^{\circ}C$ water was used as a working fluid to simulate a condenser and the RNG $k-{\epsilon}$ turbulence model was adopted. Calculation results were obtained in fully developed turbulent flow with constant surface heat flux boundary condition. Relative terms were introduced to investigate the substitution effect of conventional smooth tubes. The dimensionless terms were the heat transfer enhancement factor, the pressure drop penalty factor, and the efficiency index. Additionally, a numerical optimization was carried out to maximize thermal performance with the concept of the robust design. A statistical analysis showed that fin height interacts with number of fins and spiral angle.

  • PDF

500W 급 마이크로 가스터빈을 위한 파형 휜을 가지는 리큐퍼레이터의 열성능 비교 (Comparison of the Thermal Performance of Recuperators with Corrugated Fins for a 500W Class Micro Gas Turbine Generator)

  • 도규형;김태훈;한용식;최병일;김명배
    • 한국군사과학기술학회지
    • /
    • 제16권6호
    • /
    • pp.847-856
    • /
    • 2013
  • In this study, thermal performance of recuperators with plain and offset strip fins is investigated to enhance the thermal efficiency of a micro gas turbine. Thermal cycle analysis is conducted to determine major design parameters of a single-pass counterflow recuperator. In order to evaluate the performance of the recuperator, the effectiveness and the pressure drop in the recuperators are chosen as the objective function and the design constraint, respectively. The optimized geometries for internal structure of the recuperators with plain and offset strip fins are obtained with varying the fin spacing and height. From the result, the recuperator with offset strip fins has better thermal performance when the fin spacing, s, is smaller than 1.45mm and the thermal performance of the recuperator with plain rectangular fins is higher than that with offset strip fins in the region of $s{\geq}1.45mm$. In addition, it is found that the entrance region effect and the longitudinal wall heat conduction effect should be taken into account for accurately predicting the thermal performance of the recuperators with both plain and offset strip fins.

오프셋 스트립 휜을 가지는 리큐퍼레이터의 내부 형상 최적화 (Optimization for the Internal Structure of a Recuperator with Offset Strip Fins)

  • 도규형;한용식;최병일;김명배
    • 한국군사과학기술학회지
    • /
    • 제14권6호
    • /
    • pp.1178-1185
    • /
    • 2011
  • In the present study, a recuperator is suggested to improve the thermal efficiency of a micro gas turbine. Primary design parameters of the recuperator are determined from the ideal cycle analysis. The counter flow plate-fin heat exchanger with offset strip fins is chosen as the type of the recuperator. In order to satisfy the design constraints which are the minimum effectiveness and the maximum pressure drop, the optimization for the internal structure of the recuperator is performed with varying the fin spacing and the fin height of offset strip fins. Also the effects of the thermal conductivity of fins and separation plates and the longitudinal heat conduction on the thermal performance of the recuperator are investigated.

초음파진동을 이용한 미세분무냉각 열전달에 관한 실험적 연구 (The Experimental Study on Mist Cooling Heat Transfer)

  • 김영찬
    • 한국분무공학회지
    • /
    • 제15권4호
    • /
    • pp.202-207
    • /
    • 2010
  • Mist cooling is widely employed as a cooling technique of high temperature surfaces, and it has heat transfer characteristics similar to boiling heat transfer which has the convection, nucleate and film boiling regions. In the present study, mist cooling heat transfer was experimentally investigated for the mist flow impacting on the heated surfaces of mico-fins. The mist flow was generated by supersonic vibration. Experiments were conducted under the test conditions of droplet flow rate, $Q=6.02{\times}10^{-9}{\sim}3.47{\times}10^{-8}\;m^3/s$ and liquid temperature, $T_f=30{\sim}35^{\circ}C$. From the experimental results, it is found that an increase in the droplet flow rate improves mist cooling heat transfer in the both case of smooth surface and surfaces of micro-fins. Micro-fins surfaces enhance the mist cooling heat transfer. Besides, the experimental results show that an increase in the droplet flow rate decrease the heat transfer efficiency of mist cooling.

강제대류 및 핵비등영역에 있어서 마이크로 휜 형상이 분무냉각 열전달에 미치는 영향 (Effects of Micro-fin Structure on Spray Cooling Heat Transfer in Forced Convection and Nucleate Boiling Region)

  • 김영찬
    • 대한기계학회논문집B
    • /
    • 제34권11호
    • /
    • pp.983-990
    • /
    • 2010
  • 본 연구에서는 냉각면의 표면온도가 비교적 낮은 강제대류 및 핵비등영역에서 다양한 종류의 마이크로 휜이 가공된 냉각면의 분무냉각 열전달에 대해 실험적으로 연구하였다. 실험결과로부터 냉각면 표면에 가공된 마이크로 휜은 분무냉각 열전달을 촉진시키며, 냉각휜의 크기와 종류에 상관없이 분무유량이 증가할수록 분무냉각 열전달도 큰 폭으로 증가하고 있음을 알 수 있었다. 또한 희박한 분무영역에서는 냉각면에 가공된 휜의 크기와 형상이 분무냉각 열전달에 큰 영향을 미치고 있으나, 분무유량이 증가할수록 이러한 경향은 점차 약해져 본 실험에서 가장 높은 분무유량조건에서는 편평한 냉각면을 제외한 모든 냉각면의 열유속이 거의 동일하게 나타나고 있음을 알 수 있었다.

마이크로핀관에서의 냉매 R-22, R-407C의 응축전열특성에 관한 연구 (Condensation heat transfer characteristics of R-22 and R-407C in micro-fin tubes)

  • 노건상
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권1호
    • /
    • pp.50-56
    • /
    • 2008
  • Experimental results for forced convection condensation of Refrigerant-22 and ternary Refrigerant-407C(HFC-32/125/134a 23/25/52 wt%) which is being considered as a substitute R-22 inside a horizontal micro-fin tube are presented. The test section was horizontal double-tube counterflow condenser with a length 4,000 mm micro-fin tube, having 8.53 mm ID, 0.2 mm fin height and 60 fins. The range of parameters of mass velocity were varied from 102.1 to 301.0 kg/(m2.s) and inlet quality 1.0. At the given experimental conditions. the average heat transfer coefficients for R-407C were lower than that for R-22 at a micro-fin tube. Over the mass velocity range tested. the PF(penalty factor) for R-22, R-407C were lower than the increasing ratio of heat transfer area by fins, and the EF(enhancement factor) for R-22, R-407C were higher than the increasing ratio of heat transfer area by fins.

3성분 혼합냉매 R-407c의 수평 마이크로핀관내 응축압력강하에 관한 연구 (Study on the pressure drop of ternary refrigerant R-407c during condensation inside horizontal micro-fin tubes)

  • 정재천
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권2호
    • /
    • pp.210-218
    • /
    • 1998
  • Experimental results for forced convection condensationof Refrigerant-22 and ternary Refrigerant-407c(HFC-32/125/134a 23/25/52 wt%) considered as a substitute R-22 inside horizontal micor-fin tubes are presented. The test section was horizontal double-tubed counterflow condenser with a length 4000 mm micro-fin tube having 9.53 mm OD., 0.2 mm fin height and 60 fins. The refrigerants R-22 and R-407c were cooled by a coolant circulated in a surrounding annulus. The range of parameters of mass velocity was varied from 102.1 to 301.0kg/($\textrm{m}^{2}.s$) with inlet quality 1.0. Both refrigerant R-22 and its alternative refrigerant R-407c were tested within the same range of parameters. At the given experimental conditions for R-22 and R-407c the pressure drops for R-407c were considerably higher than those for R-22 at micro-fin tubes. Over the mass velocity range tested the PF(penalty factor)was lower than the increasing ratio of heat transfer area by fins. Based on the data correlation was proposed for predicting the frictional pressure drops for R-22 and R-407c for a duration of condensation inside a horizontal micro-fin tube.

  • PDF