• Title/Summary/Keyword: Micro Bubble

Search Result 196, Processing Time 0.025 seconds

A Study for Micro-patterning using an Electrostatic Inkjet (정전기력 잉크젯 프린팅을 이용한 마이크로 패터닝에 관한 연구)

  • Kim, Jun-Woo;Choi, Kyoung-Hyun;Kim, Dong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1103-1106
    • /
    • 2008
  • For the current display process, the innovative micro pattern fabrication process using semiconductor process should be developed, which requires the expensive equipment, the limited process environment and the expensive optic-sensitive material. The effort of process innovation during past several years ends up the limit of cost reduction. The existing ink jet technologies such as a thermal bubble ink jet printing and a piezo ink jet printing are required to shorten the nozzle diameter in order to apply to the micro pattern fabrication. In this paper, as one way to cope these problems the micro pattern equipment based on the electrostatic ink jet has been developed and carried out some experiments.

  • PDF

Experimental and Numerical Study on the Binary Fluid Flows in a Micro Channel (마이크로 채널 내의 이상유동에 대한 실험 및 수치해석적 연구)

  • Park, Jae-Hyoun;Heo, Hyeung-Seok;Suh, Young-Kweon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.86-91
    • /
    • 2006
  • In this parer, we present the bubble forming and motion in the micro channel by using the two-dimensional numerical computation and experiment. In the numerical computation, The Lattice Boltzmann method(LBM) and free-energy model is used to treat the interfacial force and deformation of binary fluid system, drawn in to a micro channel and a numerical simulation is carried out by using the parallel computation method. The urn in this investigation is to examine the applicability of LBM to numerical analysis and experimental method of binary fluid separation and motion in the micro channel.

  • PDF

Wahsing Effect of Micor-Bubbles and Changes in Quality of Lettuce (Lacutuca sativa L.) during Storage (마이크로버블에 의한 상추의 세척효과 및 저장 중 품질변화)

  • Lee, Seon-Ah;Youn, Aye-Ree;Kwon, Ki-Hyun;Kim, Byeong-Sam;Kim, Sang-Hui;Cha, Hwan-Soo
    • Food Science and Preservation
    • /
    • v.16 no.3
    • /
    • pp.321-326
    • /
    • 2009
  • We assessed quality changes in and washing effects (time and method) on lettuce (Lactuca sativa L.) treated with micro-bubbles. Samples were treated with micro-bubbling for 1, 3, or 5 min, and the 5-min treatment yielded the best results in terms of reduced total microorganism counts, sensory aspects, and degree of washing. Total microorganism counts were 4.30 log colony-forming units (CFU)/g in unwashed lettuce(CT), 4.10 log CFU/g in hand-washed lettuce (HW), 3.98 log CFU/g in conventional, bubble-washed lettuce (BW) and 3.25 log CFU/g in micro-bubble-washed lettuce (MW). In comparison, total counts of samples examined after 10 days of storage were 7.00 log CFU/g for CT, 6.19 log CFU/g for HW, 6.02 log CFU/g for BW, and 5.89 log CFU/g for MW. The lowest counts were seen after micro-bubble treatment. BW and MW samples showed significantly higher counts than did CT and HW samples. In general, BW and MW samples did not vary significantly in count numbers. MW showed a 2.3-fold lower residual pesticide level compared with CT, and also had the lowest level of impurities. HW and BW samples were not well washed.

Improvement of Medium and Small Urban Stream Water Quality and Applicability of Design Factor Using Biological and Physicochemical Processing (도심지역 내 중·소하천 수질 개선을 위한 가압부상 및 관로형 미생물 부착 공정 적용에 관한 연구)

  • Kim, Moon-Ki;Choi, Jung-Su;Kim, Sam-Ju;Kim, Hyun-Gu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.7
    • /
    • pp.509-517
    • /
    • 2013
  • The purpose of this study is to assess the applicability of device-type stream coagulation process which combines physiochemical, biological processing for efficient improvement of water quality in small, middle-sized urban streams. The stream purification facility of this study is compose of pressure flotation type Micro Bubble Process(MBP) to remove TSS and TP and conduit line type Attached Microbial Pipe System(AMPS) to remove BOD. Test conditions of each device were set by floating stay time and change of ultra fine bubble injection amount of MBP, and change of AMPS stay time. Also, removal efficiency of pollution sources of each process were assess by change of season. As result of continuous operation of each process, MBP showed a maximum of TSS 83.69%, TP 95.15% process efficiency and AMPS showed a maximum of 52.95% TBOD5 removal efficiency. Also as result of circular operation of each process, MBP showed a maximum of TSS 69.75%, TP 70.17% process efficiency and AMPS showed a maximum of 68.58% TBOD5 removal efficiency. Therefore, it is considered that this stream coagulation process is effective in improving the water quality of streams in urban areas.

An Experimental Study on Direct Cooling Performance using Pool Boiling from Micro-Porous Coated Surface (마이크로다공성 코팅된 발열체에서의 풀비등 직접냉각 성능에 관한 실험적 연구)

  • Kim, Tae-Gyun;Lee, Kyu-Jung;Kim, Yong-Chan;Park, Chan-Sung
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1353-1358
    • /
    • 2004
  • An experimental study of pool boiling behavior on micro-porous enhanced square heater surfaces immersed in PF5060 is performed. The effects of heater orientation, Subcooling and substrate distance on the pool boiling heat transfer performance for the double heaters were investigated under increasing heat-flux conditions. The boiling performance of micro-porous coated surface was better than that of plain surface. The double heaters with upper substrate of 0.2cm substrate interval have lower boiling performances compared with the results for the double heaters with that of 0.5cm and 1.0cm substrate interval and without the substrate. In comparison to upper heater and below heater with orientation, the upper heater has lower superheat temperature than the below heater due to the bubble sweeping.

  • PDF

Improvement of VSWR Measurement for Various Modulated Signals at 1.8 GHz Band (다양한 변조 신호의 1.8 GHz 대역 VSWR 측정 개선에 관한 연구)

  • Park, Sang-Jin;Kang, Sung-Min;Koo, Kyung-Heon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.9
    • /
    • pp.833-839
    • /
    • 2011
  • This paper has suggested a technique for measuring VSWR at 1.8 GHz band for various modulated signals. By using directional coupler the power of incident and reflected wave is measured, and in order to minimize the size and cost of the measuring circuit, a SPDT(Single Pole Double Throw) switch is adopted to realize the circuit with just one detector and one A/D(Analog to Digital) converter. MCU(Micro Control Unit) is used to calculate the voltage reflection coefficient and VSWR, and the measured VSWR error has improved by approximately 0.2 with applying a simple bubble sorting algorithm to reduce the measurement error, the MCU process time and load.

Development of Micro-chip Removal Equipment Using Bubble (버블을 이용한 미세칩 제거장치의 개발)

  • Choi, Sung-Yun;Kwon, Dae-Gyu;Lee, Sea-Han;Park, Tae-hyun;Wang, Duck Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.10
    • /
    • pp.88-94
    • /
    • 2021
  • Machining operations require the removal of chips to keep the water-soluble cutting oil clean and fresh throughout the operation time. Water-soluble cutting oil for metal processing is diluted using a 3-8% solution in water which is generally replaced every three to six months. This study aims to develop multiple purification devices to efficiently remove fine contaminating particles from water-soluble cutting oil. The 2D concept designs were created using AutoCAD. The designs were drawn using the 3D modelling feature of CATIA. Flow analysis was performed in a bubble purifier using Ansys computational fluid dynamics (CFD). This analysis has aided in improving the design and structure of the device to create the final prototype. Experiments were conducted to check the prototype's performance. Comparisons of the effects of each process variable on the experiment was carried out using ANOVA.

An Experimental Study on Boiling Heat Transfer of PF5060 on the Shape and Orientation of Micro-Fin Surfaces (마이크로휜 표면과 발열체 기울기에 따른 PE5060의 비등 열전달에 관한 실험적 연구)

  • Kim Yoon-Ho;Kim Choong;Lee Kyu-Jung;Kim Youngchan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.1 s.244
    • /
    • pp.74-81
    • /
    • 2006
  • Experiments to measure the pool boiling heat transfer on the micro-fin surfaces were performed with PF5060. The effects of various orientation and subcooling of heat surface on pool boiling performance were investigated under various heat-flux conditions for plain and micro-fin surfaces. The comparison between the results of this study and those of previous work shows a similar trend at the same conditions. From the results, it is proved that nucleate boiling performance is strongly dependent on the orientation, the micro-fin structure and the subcooling of heat surface. The heat flux on the surface with orientation angles of $45^{\circ}$ and $90^{\circ}$ was larger than that on horizontal surface(${\theta}=0^{\circ}$) at same wall superheat because of the effect of bubble sweeping. The nucleate boiling performance of micro-fin surfaces is enhanced by decreasing the fin size(WxL) and the pitch, respectively. The subcooling makes nucleate boiling performance lower for both micro-fin and plain surfaces.

Heavy Metal Removal Efficiency in Accordance with Changes in Acid Concentrations in a Micro-nano Bubble Soil Washing System and Pickling Process (마이크로나노버블 토양세척시스템 및 산세척 복합공정의 산 농도변화에 따른 중금속 제거효율에 관한 연구)

  • Jung, Jin-Hee;Choi, Ho-Eun;Jung, Byung-Gil;Sung, Nak-Chang;Yi, Gi-Chul;Choi, Young-Ik
    • Journal of Environmental Science International
    • /
    • v.26 no.1
    • /
    • pp.23-28
    • /
    • 2017
  • This study was aimed at determining the changes in heavy metal removal efficiency at different acid concentrations in a micro-nanobubble soil washing system and pickling process that is used to dispose of heavy metals. For this purpose, the initial and final heavy metal concentrations were measured to calculate the heavy metal removal efficiency 5, 10, 20, 30, 60, and 120 min into the experiment. Soil contaminated by heavy metals and extracted from 0~15 cm below the surface of a vehicle junkyard in the city of U was used in the experiment. The extracted soil was air-dried for 24 h, after which a No. 10 (2 mm) was used as a filter to remove large particles and other substances from the soil as well as to even out the samples. As for the operating conditions, the air inflow rate in the micro-nano bubble soil washing system was fixed at 2 L/min,; with the concentration of hydrogen peroxide being adjusted to 5%, 10%, or 15%. The treatment lasted 120 min. The results showed that when the concentration of hydrogen peroxide was 5%, the efficiency of Zn removal was 27.4%, whereas those of Ni and Pb were 28.7% and 22.8%, respectively. When the concentration of hydrogen peroxide was 10%, the efficiency of Zn removal was 38.7%, whereas those of Ni and Pb were 42.6% and 28.6%, respectively. When the concentration of hydrogen peroxide was 15%, the efficiency of Zn removal was 49.7%, whereas those of Ni and Pb were 57.1% and 42.6%, respectively. Therefore, the efficiency of removal of all three heavy metals was the highest when the hydrogen peroxide concentration was 15%.