• Title/Summary/Keyword: Micro Air Bubble

Search Result 54, Processing Time 0.023 seconds

Comparison of Dissolved Air and Micro-Bubble Concentration by a Micro-Bubble Generating Pump (미세기포 발생 펌프에서 생성되는 기포농도와 용존공기농도의 비교)

  • Lee, Chang-Han;Ahn, Kab-Hwan
    • Journal of Environmental Science International
    • /
    • v.23 no.11
    • /
    • pp.1835-1842
    • /
    • 2014
  • The goal of this study was to evaluate micro-bubble concentration ($C_{air}$) in water by air/water ratio (A/W ratio) with a micro-bubble generating pump. The estimation of micro-bubble concentration is based on the balance of inlet/outlet air and water flow rate. On net A/W ratio to be generated micro-bubble, we found that the obtained the $C_{air}$ are shown as a function of discharge pressure ($P_g$) of the micro-bubble generating pump. The correlation of the $C_{air}$ and the $P_g$ ($C_{air}=3.261P_g-1.754$) was adequately described by the least square methods with a high correlation coefficient (r = 0.9459) and calculated values fit the experimental data quite well. The $C_{air}$ was lower than theoretical dissolved air concentration ($C_{aq}$) calculated by Henry's law. The $C_{air}$ for being operated the micro-bubble generating pump was 6.75 - 39.53 mL/L, however, we found that the optimum of the $C_{air}$ to generate micro-bubble was the range from 10 to 12 mL/L.

Prediction of Micro-Bubble Releasing Concentration with the Retention Time of a Micro-Bubble Generating Pump (미세기포 발생펌프 내 체류시간에 따른 미세기포의 발생 농도 예측)

  • Ambrosia, Matthew Stanley;Lee, Chang-Han
    • Journal of Environmental Science International
    • /
    • v.25 no.6
    • /
    • pp.829-837
    • /
    • 2016
  • The mechanism of micro-bubble generation with a pump is not clarified yet, so the design of water treatment systems with a micro-bubble generating pump is based on trial and error methods. This study tried to explain clearly quantitative relationships of experimental micro-bubble concentration ($C_{air}$) of continuous operation tests with a micro-bubble generating pump and theoretical air solubility. Operation parameters for the tests were discharge pressure ($P_g$), water ($Q_{w0}$) and air ($q_0$) flow rates, orifice diameter ($D_o$), and retention time (t). The experimental micro-bubble concentrations ($C_{air}$) at 4.8 atm of discharge pressure ($P_g$) were in the range of 21.04 to 25.29 mL/L. When the retention time (t) by changing the pipe line length ($L_p$) increased from 1.22 to 6.77s, the experimental micro-bubble concentrations ($C_{air}$) increased from 25.86 to 30.78 mL air/L water linearly. The dissolved and dispersed micro-bubble concentrations ($C_{air}$) are approximately 4 times more than the theoretical air solubility.

Micro-Bubble Generating Properties on Gas/Liquid Flow Rate Ratio with the Sludge Flotation/Thickening Apparatus (슬러지 부상농축장치의 기·액 유량비에 따른 미세기포 발생 특성)

  • Lee, Chang-Han;Park, Jong-Won;Ahn, Kab-Hwan
    • Journal of Environmental Science International
    • /
    • v.23 no.1
    • /
    • pp.97-104
    • /
    • 2014
  • The sludge flotation/thickening apparatus equipped a micro-bubble generating pump was used to investigate micro-bubble generating properties on operational parameters. We evaluated micro-bubble generating properties as results to be operated the apparatus by operational parameters which are pump discharge pressure, air/water ratio(A/W ratio), air flow rate, and water flow rate. Micro-bubble generating efficiencies in pumps without recycling flow and with 50% of recycling flow was found to be very efficient on optimum A/W ratio from 1.06 to 3.62% and optimum A/W ratio from 1.05 to 4.06%, respectively. In condition of 3.6% of A/W ratio, we showed that the apparatus could be generated 36,000 ppm of micro-bubble concentration to be optimum treatment efficiency in sludge thickening process.

Analytical Study on the Behavior of the Bubble in the Micro Two-Phase Closed Thermosyphon (초소형 밀폐형 이상 써모싸이폰 기포의 거동에 관한 해석적인 연구)

  • Lee, Y.P.;Lee, Y.S.;Lee, Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.2
    • /
    • pp.85-93
    • /
    • 1993
  • The rise of a large gas bubble or slug in a Micro Two-Phase Closed Thermosyphon with a thin wire insert has been analiged by the potential flow theory. The effect of the interfacial surface tension is explicitly accounted by application of the Kelvin-Laplace equation and solved for the bubble shape. The solution is expressed in terms of the Stokes stream function which consists of an infinite series of Bessel functions. The conditions of the bubble movement in a Micro Two-Phase Closed Thermosyphon were theoretically ascertained.

  • PDF

Effect of Micro Bubble on the High-Voiume Slag Concrete Mixed with Emulsified Refined Cooking Oil (마이크로버블이 유화처리 정제유지류(ERCO)혼입 고로슬래그 다량 치환 콘크리트의 특성에 미치는 영향)

  • Kim, Min-Yoyng;Park, Young-Jun;Baek, Doo-Hwan;Baek, Byung-Hoon;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.44-45
    • /
    • 2015
  • Although the carbonation problem of high-volume slag concrete has been solved by the mixed use of emulsified refine cooling oil as the pilot study, there was an instance of securing air quantity and frost resistance followed by the use of Expancel due to the problem of having vulnerability in frost resistance in result as the air quantity has not been secured. But due to the problem of Expancel not being economical, air quantity and frost resistance of high-volume slag concrete mixed with ERCO are attempted to be secured using micro bubble that can remain in the water for a long time as a relatively economical and very microscopic bubble.

  • PDF

An Effect of the Micro Bubble Formation Depending on the Saturator and the Nozzle in the Dissolved Air Flotation System (DAF 공정에서 공기포화장치와 노즐 특성 별 미세기포 발생에 미치는 영향)

  • Park, S.C.;Oh, H.Y.;Chung, M.K.;Song, S.L.;Ahn, Y.H.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.929-936
    • /
    • 2013
  • The saturator and injection nozzle are important facilities on the dissolved air flotation process. To increase the formation of micro bubble, it is required to improve the air dissolving performance in the saturator and keep the pressure uniform from the saturator to the nozzle. This study aimed to evaluate the performance of the saturator and the hydraulic effect of the nozzle and the pipe structure. The air volume concentration, bubble size and bubble residual time were measured in the test. The saturator, which had mounted with the spray nozzle, showed a good performance for bubble formation. Also, the characteristics of micro bubble formation were influenced by pressure uniformity and flow velocity through the orifice in the nozzle.

Study on the Characteristics of Bubble and Liquid Slugs for Gas-Liquid Taylor Flow in a Rectangular Micro-channel (사각 마이크로 채널 내 Taylor Flow의 기포 및 액체 슬러그 유동 특성에 대한 연구)

  • Lee, Jun Kyoung;Lee, Kwan Geun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.520-526
    • /
    • 2015
  • The characteristics of gas-liquid Taylor (Slug) flow in a square micro-channel of $600{\sim}600{{\mu}m}$ were investigated experimentally in this paper. The test fluids were nitrogen and water. The liquid and gas superficial velocities were 0.01~3 m/s and 0.1~3 m/s, respectively. Bubble and liquid slug length, bubble velocity, and frequency were measured by analyzing optical images using a high speed camera. Bubble length decreased with higher liquid flow rate, which increased dramatically with higher gas flow rate. However, slug length did not vary with changes in inlet liquid conditions. Additionally, bubble velocities and frequencies increased with higher liquid and gas flow rates. It was found that measured bubble lengths were in good agreement with the empirical models in the existing literature, but slug lengths were not.

The treatment of sewage using DAF pump system with micro bubble and non-powered flotation tank (응집제 자동혼합형 미세기포 발생장치와 무동력 부상분리조를 이용한 하수의 처리)

  • Kim, Dong-Ha;Lee, Soo-Young;Jung, Eui-Taek
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.659-666
    • /
    • 2011
  • Although DAF(Dissolved Air Flotation) has been successfully accepted for water and wastewater treatment, the fundamental characteristics of the process have not been fully investigated. Water is saturated with compressed air to dissolve the air into the water at high pressure in saturation tank. Then the water containing dissolved air is released into a floatation tank at a lower pressure, generating micro-bubbles that rise gently through the water and carry the suspended matter to the surface. This study investigated the removal of sewage using automatic mixture type DAF pump and non-powered flotation tank. Characteristics of two devices were compared and analyzed with samples. The results showed that the PAC exhibited higher performance than other coagulants. When air dosage was 2.5ml/l/min, treatment was stable in operation. In the DAF pump with a pressure of 4 atm., the average size of bubbles was 36.2${\mu}m$. Removal efficiency of SS was 80%. At this time removal efficiency of COD was about 80%, of T-N was 30% and T-P was 70% in stable operation. It was concluded that DAF pump system with micro bubble performed higher efficiencies compared to general DAF system for treating wastewater.

Study on Micro-bubble Generation Characteristics in Venturi Cavitation using Laser Diffractometer (레이저 회절 측정기를 이용한 벤츄리 캐비테이션에서의 마이크로버블 발생 특성 연구)

  • Lim, Yun Gyu;Yang, Hae Jeong;Kim, Yung Il
    • Journal of Drive and Control
    • /
    • v.16 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • The use of micro bubbles in industrial fields has been increasing in the recent years., particularly micro-bubble sterilization and water purification effects. Various methods have been developed for the generation of micro-bubbles. Depending on the method of generating bubbles, the micro-bubbles can be roughly classified into saturation molding, cavitation and rotation flow types. The objective of this study was to use ventilated tube type as a method of generating micro-bubbles in order to purify large amount of water quality such as lakes and reservoirs. This method shows a difference in efficiency in which micro-bubbles are generated depending on the contact ratio of gas to liquid. The study also investigated the optimal gas liquid contact ratio by applying various orifice methods and investigated the optimum condition of micro-bubble generation by gas Based on this, a technology to develop a micro-bubble generator with a venturi type nozzle shape that has a high water purification effect was developed.

Zeta Potential Measurement of Micro Bubbles Generated by Electrolysis (전기분해(電氣分解)시 알루미늄 극판(極板)에서 발생(發生)한 미세기포(微細氣泡)의 제타전위(電位) 측정(測定))

  • Kim, Won-Tae;Han, Moo-Young;Lee, Sung-Woo;Han, Yi-Seon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.4
    • /
    • pp.343-349
    • /
    • 2000
  • Techniques such as dissolved air flotation and electroflotation, which utilize micro bubbles, are increasingly used for water and wastewater treatment. Most studies have concentrated on particle characteristics. Pretreatments that manipulate particle size and zeta potential were considered important. A recent study, which modeled the collision mechanism between micro bubbles and particles in dissolved air flotation, suggested bubble characteristics should also be important. Hydrogen micro bubbles were generated electrolytically and their zeta potentials measured under various conditions using a novel electrophoresis method. Effects of several parameters were investigated. Bubble zeta potentials were found to be pH dependent, and to have a negative value around neutral pH, becoming zero or positive at lower pH. The pH at zero zeta potential was 5.0 under study conditions. Using artificial solution and tap water, at fixed pH, bubble zeta potentials varied with solution composition. Zeta potentia]s of bubbles were affected by the types of cations and anions in solution but not by the voltage applied. These findings will help improve efficiencies of particle removal processes that utilize micro bubbles. As bubble zeta potential varies with solution composition, it needs to be measured for each composition to understand those effects, which increase removal efficiency.

  • PDF