• Title/Summary/Keyword: Metrology frame

Search Result 7, Processing Time 0.023 seconds

Mechanical Design for an Optical-telescope Assembly of a Satellite-laser-ranging System

  • Do-Won Kim;Sang-Yeong Park;Hyug-Gyo Rhee;Pilseong Kang
    • Current Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.419-427
    • /
    • 2023
  • The structural design of an optical-telescope assembly (OTA) for satellite laser ranging (SLR) is conducted in two steps. First, the results of a parametric study of the major design variables (e.g. dimension and shape) of the OTA part are explained, and the detailed structural design of the OTA is derived, considering the design requirements. Among the structural-shape concepts of various OTAs, the Serrurier truss concept is selected in this study, and the collimation of the telescope according to the design variables is extensively discussed. After generating finite-element models for different structural shapes, self-gravity analyses are performed. To minimize the deflection and tilt of the mirror and frame for the OTA under the limited design requirements, a parametric study is conducted according to design variables such as the shapes of the upper and lower struts and the spider vane. The structural features found in the parametric study are described. Finally, the OTA structure is designed in detail to maintain the optical alignment by balancing the gravity deflections of the upper and lower trusses using the optimal combination of the parameters. Additionally, thermal analysis of the optical telescope design is evaluated.

Video-based Height Measurements of Multiple Moving Objects

  • Jiang, Mingxin;Wang, Hongyu;Qiu, Tianshuang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.9
    • /
    • pp.3196-3210
    • /
    • 2014
  • This paper presents a novel video metrology approach based on robust tracking. From videos acquired by an uncalibrated stationary camera, the foreground likelihood map is obtained by using the Codebook background modeling algorithm, and the multiple moving objects are tracked by a combined tracking algorithm. Then, we compute vanishing line of the ground plane and the vertical vanishing point of the scene, and extract the head feature points and the feet feature points in each frame of video sequences. Finally, we apply a single view mensuration algorithm to each of the frames to obtain height measurements and fuse the multi-frame measurements using RANSAC algorithm. Compared with other popular methods, our proposed algorithm does not require calibrating the camera, and can track the multiple moving objects when occlusion occurs. Therefore, it reduces the complexity of calculation and improves the accuracy of measurement simultaneously. The experimental results demonstrate that our method is effective and robust to occlusion.

Implementation on the Portable Blood Gas Analyzer and Performance Estimation/A Study on the Hydrometer Calibration System using Image Processing (영상처리 기법을 이용한 부액계 자동 교정 시스템 구현)

  • Lee, Yong-Jae;Chang, Kyung-Ho;Oh, Chae-Youn;Jung, Sang-Duk
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.258-264
    • /
    • 2003
  • The present paper studies how to calibrate hydrometer using image process. The method aligns particular scales of hydrometer selected for calibrating the hydrometer with the horizontal plane of the reference liquid automatically without man's operation. Major parts composing the system are CCD camera, frame grabber, stepping motor and image process program. The image process program is composed of a part that locates the meniscus and aligns it with a scale and a part that controls the step motor. To verify the performance of the developed method, this study compares the meniscus and scale observed directly with the naked eye with the result of calibration by the manual calibration method. The differences between the corrections were less than $0.004\;kg/m^3$ with uncertainty of $0.06\;kg/m^3$. These showed that the calibration results of the developed hydrometer calibration using image process nearly equal to manual method.

Measuring Methods for Two-dimensional Position Referring to the Target Pattern (참조패턴 기반의 2차원 변위 측정 방법론)

  • Jung, Kwang Suk;Lee, Sang Heon;Park, Sung-Jun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.1
    • /
    • pp.77-84
    • /
    • 2013
  • In this paper, we review two-dimensional measuring methods referring to target patterns. The patterns consist of two linearly-repeated patterns or is designed repeatedly in two-dimension. The repeated properties are reflectivity, refractivity, air-gapping distance, capacitance, magnetic reluctance, electrical resistance and sloping gradient, etc. However, the optical methods are generally used for high speed processing and density, and their encoding principles are treated here. In case of two-dimensional pattern, as there is not inherently error between single units encoding the pattern except for the metrology frame errors, the end-effector position of an object accompanying the pattern can be measured with respect of the global frame without via error. Therefore, it is regarded as a substitute for laser interferometer with severe environmental constraints and has been applied to the high-accurate planar actuator.

Development of a Deadweight Force Standard Machine with Weight Change Mechanism (추교환식 실하중 힘표준기의 개발)

  • Kim, Gab-Soon;Song, Hou-Keun;Kang, Dae-Im;Lee, Jeong-Tae;Park, Yon-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.8
    • /
    • pp.203-212
    • /
    • 1999
  • This paper describes a deadweight force standard machine with the weight change mechanism which can be used as a primary force standards at a national metrology institute. Since commercial deadweight force machine can generate forces by hanging weights to the weight supporter serially, force steps from deadweight force measuring devices of each having different capacity. In order to increase the force steps, we have specially designed a weight mechanism in which the machine can select the necessary weights and generate the load by hanging the selected weights to the weight supporter. The machine can generate 속 force of the range of 2 kN to 110 kN with force step of 1 kN. All weights have been accurately compensated and calibrated by a mass comparator and its standard uncertainty is less than 2.2 ${\times}\;10^{-6}$. The relative expanded uncertainty of the machine is 1.3 ${\times}\;10^{-5}$.

  • PDF

Evaluation of Flow Experience by using Psychophysiological Visual Feedbacks

  • Kim, Jung Yong;Min, Seung Nam;Park, Yong Duck
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.6
    • /
    • pp.481-487
    • /
    • 2013
  • Objective: The present study aims to evaluate the visual reactions of users when they are playing games of different flow levels, and to explore the visual variables that can sensitively reflect the different flow levels. Background: The flow is defined as a psychological state where interface users feel their actions in a virtual setting identical to those in real environment. To measure the flow states of users, the questionnaire-based FSS(Flow State Scale) has mostly been used. However, this method is a qualitative test that has limits in terms of the accuracy of users' flow experiences. Therefore, more accurate methods to measure users' flow experiences are required. Method: Ten subjects participated in the experiment, where the independent variables were three games with different flow levels(puzzle games, dot drawing and coloring) and the time frame(the first and last 10 seconds in game playing), whereas the dependent variables included the pupil size and the frequency and duration of eye blinking. This study was a within-subject design. Each participant performed three types of games with different flow levels 3 times for each for 10 minutes, and their visual reactions to each game were measured. Results: The higher the flow cause the bigger pupil size(p<0.01) and the lower eye blinking frequency(p<0.1), indicating that different types of games lead to different flow levels. The pupil size during the last 10 seconds when the flow level was higher was bigger by 2.1% compared with that during the first 10 seconds in game playing(p<0.1), and the eye blinking frequency decreased by 12%(p<0.01). Conclusion: It was found out that the pupil size and the frequency and duration of eye blinking were psychophysiological indices for evaluating users' flow experiences, which could quantify the flow states users go through. The psychophysiological variables capable of measuring diverse aspects of the flow need diversifying to be applicable to precise measurement of the flow. Application: These studies are warranted for both quantitative analysis of flow levels and qualitative improvement of cyber leisure in line with development of healthy games.