• Title/Summary/Keyword: Metrology

Search Result 725, Processing Time 0.023 seconds

The Estimation of Fatigue Life for Al/CFRP Hybrid Laminated Composites using the Strain-Life Method (변형률-수명 평가기법을 이용한 Al/CFRP 하이브리드 적층 복합재의 피로수명 측정)

  • Yang, Seong Jin;Kwon, Oh Heon;Jeon, Sang Koo
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.3
    • /
    • pp.7-14
    • /
    • 2021
  • Hybrid laminated Al/carbon-fiber-reinforced plastic (CFRP) composites are attracting considerable attention from industries such as aerospace and automobiles owing to their excellent specific strength and specific rigidity. However, when this material is used to fabricate high-pressure fuel storage containers subjected to repeated fatigue loads, fatigue life evaluation for the working load is regulated as an important criterion for operational safety and ease of maintenance. Among the existing evaluation methods for these vessels, the burst test and the hydraulic repeat test require expensive facilities. Thus, the present study aims to develop an improved fatigue life test for Al/CFRP laminated hybrid composites. The test specimen was manufactured using a curved mold considering the shape of a type III high-pressure storage container. The strain-life method was used for fatigue life evaluation, and the life was predicted based on the transition life. The results indicate that the more complex the CFRP stacking sequence, the longer is the transition life. This test method is expected to be useful for ensuring the fatigue safety and economy of hybrid laminate composites.

Long Term Reliability of Fluroelastomer (FKM) O-ring after Exposure to High Pressure Hydrogen Gas

  • Choi, Myung-Chan;Lee, Jin-Hyok;Yoon, Yu-mi;Jeon, Sang-Koo;Bae, Jong-Woo
    • Elastomers and Composites
    • /
    • v.55 no.4
    • /
    • pp.270-276
    • /
    • 2020
  • The long-term durability of an FKM O-ring used as parts of a hydrogen station was investigated by exposing it to high-pressure gaseous hydrogen for 1, 3, and 7 days at room temperature. Changes in its sealing force were subsequently measured at 150℃ using intermittent compression stress relaxation (CSR). No changes in the tensile properties of FKM O-ring were observed, but its initial and overall sealing forces at 150℃ significantly decreased with increasing exposure time to hydrogen gas. Microvoid formation in the FKM O-ring upon exposure to high-pressure hydrogen was minimized over time after the ring was exposed to atmospheric pressure at room temperature, which prevented changes in its tensile properties. However, applying heat accelerated FKM O-ring oxidation, which decreased its sealing force. These results indicated that identifying changes in the sealing force of rubber materials using intermittent CSR is not sufficient for monitoring changes in mechanical properties under high-pressure hydrogen atmospheres; however, it is suitable for evaluating the long-term durability of sealing materials for hydrogen station applications under similar conditions.

Evaluation of peak-fitting software for magnesium quantification through k0-instrumental neutron activation analysis

  • Dasari, Kishore B.;Cho, Hana;Jacimovic, Radojko;Park, Byung-Gun;Sun, Gwang-Min
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.462-468
    • /
    • 2022
  • The selection and effective utilization of peak-fitting software for conventional gamma-ray spectrum analysis is significant for accurate determination of the mass fraction of elements, particularly in complex peak regions. Majority of the peak-fitting programs can derive similar peak characteristics for singlet peaks, but very few programs can deconvolute multi-peaks in a complex region. The deconvolution of multi-peaks requires special peak-fitting functions, such as left and right-skew distributions. In the this study, 843.76 keV (27Mg) peak area from the complex region (840 keV-850 keV) determined and compared using four different peak-fitting programs, namely, GammaVision, Genie2000, HyperLab, and HyperGam. The 843.76 keV peak interfered with 841.63 keV (152mEu) and 846.81 keV (56Mn). The total Mg concentration was determined through k0-instrumental neutron activation analysis by applying the isotopic interference correction factor 27Al(n,p)27Mg through the simultaneous determination of Al concentration. HyperLab and HyperGam peak-fitting programs reported consistent peak areas, and resultant concentrations agreed with the certified values of matrix-certified reference materials.

Design and Fabrication of an Off-axis Elliptical Zone Plate in Visible Light

  • Anh, Nguyen Nu Hoang;Rhee, Hyug-Gyo;Kang, Pilseong;Ghim, Young-Sik
    • Current Optics and Photonics
    • /
    • v.6 no.1
    • /
    • pp.44-50
    • /
    • 2022
  • An off-axis zone plate is able to focus on a single order while neglecting the zeroth order in a visible imaging system. This allows one to enhance the contrast quality in diffractive images, which is the major advantage of this type of zone plate. However, most previous reflection zone plates are used in focusing X-rays with a small grazing incident angle and are intricately designed with the use of a local grating period. In this study, we suggest the design of an off-axis elliptical zone plate (EZP) that is used to focus a monochromatic light beam with separation between the first and unfocused orders under a large grazing incident angle of 45°. An assumption using the total grating period, which depends on the average and constant grating period, is proposed to calculate the desired distance between the first and zeroth order and to simplify the construction of a novel model off-center EZP. Four diffractive optical elements (DOEs) with different parameters were subsequently fabricated by direct laser lithography and then verified using a performance evaluation system to compare the results from the assumption with the experimental results.

XGBoost Based Prediction Model for Virtual Metrology in Semiconductor Manufacturing Process (반도체 공정에서 가상계측 위한 XGBoost 기반 예측모델)

  • Hahn, Jung-Suk;Kim, Hyunggeun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2022.05a
    • /
    • pp.477-480
    • /
    • 2022
  • 반도체 성능 향상으로 신호를 전달하는 회로의 단위가 마이크로 미터에서 나노미터로 미세화되어 선폭(linewidth)이 점점 좁아지고 있다. 이러한 변화는 검출해야 할 불량의 크기가 작아지고, 정상 공정상태와 비정상 공정상태의 차이도 상대적으로 감소되어, 공정오차 및 공정조건의 허용범위가 축소되었음을 의미한다. 따라서 검출해야 할 이상징후 탐지가 더욱 어렵게 되어, 높은 정밀도와 해상도를 갖는 검사공정이 요구되고 있다. 이러한 이유로, 미세 공정변화를 파악할 수 있는 신규 검사 및 계측 공정이 추가되어 TAT(Turn-around Time)가 증가하게 되었고, 웨이퍼가 가공되어 완제품까지 도달하는데 필요한 공정시간이 증가하여 제조원가 상승의 원인으로 작용한다. 본 논문에서는 웨이퍼의 검계측 데이터가 아닌, 제조공정 과정에서 발생하는 다양한 센서 및 장비 데이터를 기반으로 웨이퍼 제조 결과가 양품인지 그렇지 않으면 불량인지 구별할 수 있는 가상계측 모델을 제안한다. 기계학습의 여러 알고리즘 중에서 다양한 장점을 갖는 XGBoost 알고리즘을 이용하여 예측모델을 구축하였고, 데이터 전처리(data-preprocessing), 주요변수 추출(feature selection), 모델 구축(model design), 모델 평가(model evaluation)의 순서로 연구를 수행하였다. 결과적으로 약 94% 이상의 정확성을 갖는 모형을 구축하는데 성공하였으나 더욱 높은 정확성을 확보하기 위해서는 반도체 공정과 관련된 Domain Knowledge 를 반영한 모델구축과 같은 추가적인 연구가 필요하다.

Evaluation of uncertainty in measurement of floor impact sound insulation of buildings using standard heavy impact source (표준중량충격원을 이용한 건축물의 바닥 충격음 차단성능 측정불확도 평가)

  • Yong-Bong Lee;Hyok-Je Kwon;Chang-Whan Kim;Man-Hee Cho;Hang Kim;SungSoo Jung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.2
    • /
    • pp.143-151
    • /
    • 2023
  • In this paper, a method for evaluating the measurement uncertainty is proposed when measuring of floor impact sound insulation of buildings using standard heavy impact source. In addition to the effect of repeated measurements, several other factors such as measurement location, impact location, equipment used for sound pressure measurement, and heavy impact source, were considered. A mathematical model for the average maximum impact sound level and the uncertainty evaluation method for each factor were proposed. The present proposed method was applied to measurement results to evaluate the average maximum impact sound pressure level and the measurement uncertainty.

Study of Surfactant Sensitized Fluorescence of Europium-Salicylic Acid Complex for the Determination of Salicylic Acid (Salicylic Acid 정량을 위한 Europium-Salicylic Acid 복합체의 계면활성제 증감 형광법에 관한 연구)

  • Alam, MD R-Mahmnur;Kamruzzaman, Mohammad;Kim, So Yeon;Jo, Hae Jin;Lee, Sang Hak;Kim, Young Ho;Suh, Jung Kee
    • Applied Chemistry
    • /
    • v.15 no.1
    • /
    • pp.29-32
    • /
    • 2011
  • Surfactant enhanced fluorescence (FL) of europium-salicylic acid (SA) complex has been studied. It was observed that weak FL of Eu(III) at the wavelength of 589 nm and 612 nm was found to be enhanced after addition of salicylic acid and cetyltrimethylammonium bromide (CTAB) surfactant upon excitation at 395 nm. Under optimized condition, FL intensity of Eu(III) at 612 nm responded linearly with the concentration of SA in the range of 5.5×10-9 to 1.5×10-6 M of SA. The detection limit was calculated from the calibration curve(3Sb/m) as 9.27×10-9 M.

Investigation of Etching Characteristics for Powered Edge-Ring Utilizing PI-VM in Capacitively Coupled Argon/SF6/O2 Plasma (PI-VM을 이용한 용량 결합 Ar/SF6/O2 플라즈마에서의 전력 인가 에지 링 식각 특성 조사)

  • Hyunju Lee;Jaemin Song;Taejun Park;Nam-Kyun Kim;Gon-Ho Kim
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.4
    • /
    • pp.7-12
    • /
    • 2023
  • The edge ring placed on the outside of the electrostatic chuck (ESC) is a key component for protecting the ESC and controlling the etching uniformity of the edge of the wafer. Therefore, it is very important to understand the etching phenomenon of edge rings for edge ring management and equipment homeostasis. In this study, a specimen with SiO2 hard mask and underlying Si mold was installed on the edge ring surface and the etching results were measured by varying the edge ring 2MHz RF power. By developing PI-VM model with high prediction accuracy and analyzing the roles of key parameters in the model, we were able to evaluate the effect of plasma and sheath characteristics around the edge ring on edge ring erosion. This analysis method provided information necessary for edge ring maintenance and operation.

  • PDF

Assessment of Wear Resistance in Tooth-Colored Materials for Primary Molar Crown Restoration in Pediatric Dentistry

  • Hyun Seok Kang;Yooseok Shin;Chung-Min Kang;Je Seon Song
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.51 no.1
    • /
    • pp.22-31
    • /
    • 2024
  • The objective of this study was to assess the wear resistance of tooth-colored materials used in crown restoration for primary molars with a chewing simulator. In this study, four groups-three experimental groups and one control group-were included. They consisted of three-dimensional (3D) printed resin crowns (NextDent and Graphy), milled nano-hybrid ceramic crowns (MAZIC Duro), and prefabricated zirconia crowns (NuSmile). Twelve mandibular second molar specimens were prepared from each group. In the wear experiment, 6.0 × 105 cycles were conducted with a force of 50 N, and a 6 mm-diameter steatite ball was used as an antagonist. The amount of wear was calculated by comparing the scan files before and after the chewing simulation using 3D metrology software, and the worn cross-section was confirmed by scanning electron microscopy (SEM). The resin and ceramic groups did not exhibit any statistically significant differences. However, compared to other crown groups, the zirconia crown group demonstrated notably reduced levels of wear (p < 0.05). In SEM images, layers and cracks were observed in the 3D-printed resin crown groups, which differed from those in the other groups.

Analysis of Patent Trends and Cooperative Network of Future-leading Items in the Field of Autonomous Driving (완전 자율주행분야 미래선도품목의 특허동향 및 협력 네트워크 분석)

  • Junghwan Lee;Jinyong Kim;Ji-hyuk Cho;Hyengsuk Kim
    • Journal of Information Technology Applications and Management
    • /
    • v.29 no.6
    • /
    • pp.1-12
    • /
    • 2022
  • In recent years, technological competition in the automobile sector is accelerating. This study analyzes the status of patents from a global perspective of three promising future items that Korea has selected as core technologies in the field of autonomous driving,. And the technological cooperation ecosystem was identified through network analysis centered on scientific metrology. As a result of the analysis, it was confirmed that the growth of individual technologies has been strengthened in recent years, and although key source technologies have been largely preempted in major global countries, a close cooperative ecosystem between institutions, companies, and universities in major countries has not yet been formed. Specifically, the US and Japan have the technological leadership, while China is rapidly rising, and Korea is chasing after it as a latecomer. Therefore, it is necessary to continuously strengthen technological cooperation such as R&D of core technology to overcome technological limitations and strengthening of infrastructure construction, attracting excellent foreign talents and international exchanges. This analysis is meaningful in that it explores the global status of Korea's technology and the possibility of technological cooperation from various perspectives in the future from the viewpoint of preoccupation of future technology, rather than grasping the trend of a specific technology.