• Title/Summary/Keyword: Methodist Materials

Search Result 8, Processing Time 0.023 seconds

A Study for Materials Collaboration between the Methodist Church Organizations (감리교 기관의 자료 협력을 위한 연구)

  • Park, Hyun-Young;Nam, Tae-Woo
    • Journal of Information Management
    • /
    • v.41 no.4
    • /
    • pp.119-140
    • /
    • 2010
  • Methodist church materials are classified with three types, centered on the organizations manufacturing and holding materials such as 1) 'materials of the Methodist headquarter' governing all of the Methodist churches in Korea, 2) 'materials of theological seminary libraries' holding academic study books related to theology, and 3) 'materials manufactured in individual churches'. In this manner, the Methodist church materials imply homogeneity in theme, but the materials have identity from each other, because organizations are different each other, too. By a characteristic of each organizations, to use Methodist church document done a director of each organization is demanded collaboration between the material departments of each organizations, this study intends to analysis material department operation status of three Methodist church organizations. As a result of analysis, it is necessary to perform the prior tasks, such as reconstructing organization to accomplish an original function of the Methodist headquarter, developing operation regulation classified with the Methodist church group, and constructing material management system.

A predictive model to guide management of the overlap region between target volume and organs at risk in prostate cancer volumetric modulated arc therapy

  • Mattes, Malcolm D.;Lee, Jennifer C.;Elnaiem, Sara;Guirguis, Adel;Ikoro, N.C.;Ashamalla, Hani
    • Radiation Oncology Journal
    • /
    • v.32 no.1
    • /
    • pp.23-30
    • /
    • 2014
  • Purpose: The goal of this study is to determine whether the magnitude of overlap between planning target volume (PTV) and rectum ($Rectum_{overlap}$) or PTV and bladder ($Bladder_{overlap}$) in prostate cancer volumetric-modulated arc therapy (VMAT) is predictive of the dose-volume relationships achieved after optimization, and to identify predictive equations and cutoff values using these overlap volumes beyond which the Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC) dose-volume constraints are unlikely to be met. Materials and Methods: Fifty-seven patients with prostate cancer underwent VMAT planning using identical optimization conditions and normalization. The PTV (for the 50.4 Gy primary plan and 30.6 Gy boost plan) included 5 to 10 mm margins around the prostate and seminal vesicles. Pearson correlations, linear regression analyses, and receiver operating characteristic (ROC) curves were used to correlate the percentage overlap with dose-volume parameters. Results: The percentage $Rectum_{overlap}$ and $Bladder_{overlap}$ correlated with sparing of that organ but minimally impacted other dose-volume parameters, predicted the primary plan rectum $V_{45}$ and bladder $V_{50}$ with $R^2$ = 0.78 and $R^2$ = 0.83, respectively, and predicted the boost plan rectum $V_{30}$ and bladder $V_{30}$ with $R^2$ = 0.53 and $R^2$ = 0.81, respectively. The optimal cutoff value of boost $Rectum_{overlap}$ to predict rectum $V_{75}$ >15% was 3.5% (sensitivity 100%, specificity 94%, p < 0.01), and the optimal cutoff value of boost $Bladder_{overlap}$ to predict bladder $V_{80}$ >10% was 5.0% (sensitivity 83%, specificity 100%, p < 0.01). Conclusion: The degree of overlap between PTV and bladder or rectum can be used to accurately guide physicians on the use of interventions to limit the extent of the overlap region prior to optimization.

Comparison study of intensity modulated arc therapy using single or multiple arcs to intensity modulated radiation therapy for high-risk prostate cancer

  • Ashamalla, Hani;Tejwani, Ajay;Parameritis, Ioannis;Swamy, Uma;Luo, Pei Ching;Guirguis, Adel;Lavaf, Amir
    • Radiation Oncology Journal
    • /
    • v.31 no.2
    • /
    • pp.104-110
    • /
    • 2013
  • Purpose: Intensity modulated arc therapy (IMAT) is a form of intensity modulated radiation therapy (IMRT) that delivers dose in single or multiple arcs. We compared IMRT plans versus single-arc field (1ARC) and multi-arc fields (3ARC) IMAT plans in high-risk prostate cancer. Materials and Methods: Sixteen patients were studied. Prostate ($PTV_P$), right pelvic ($PTV_{RtLN}$) and left pelvic lymph nodes ($PTV_{LtLN}$), and organs at risk were contoured. $PTV_P$, $PTV_{RtLN}$, and $PTV_{LtLN}$ received 50.40 Gy followed by a boost to $PTV_B$ of 28.80 Gy. Three plans were per patient generated: IMRT, 1ARC, and 3ARC. We recorded the dose to the PTV, the mean dose ($D_{MEAN}$) to the organs at risk, and volume covered by the 50% isodose. Efficiency was evaluated by monitor units (MU) and beam on time (BOT). Conformity index (CI), Paddick gradient index, and homogeneity index (HI) were also calculated. Results: Average Radiation Therapy Oncology Group CI was 1.17, 1.20, and 1.15 for IMRT, 1ARC, and 3ARC, respectively. The plans' HI were within 1% of each other. The $D_{MEAN}$ of bladder was within 2% of each other. The rectum $D_{MEAN}$ in IMRT plans was 10% lower dose than the arc plans (p < 0.0001). The GI of the 3ARC was superior to IMRT by 27.4% (p = 0.006). The average MU was highest in the IMRT plans (1686) versus 1ARC (575) versus 3ARC (1079). The average BOT was 6 minutes for IMRT compared to 1.3 and 2.9 for 1ARC and 3ARC IMAT (p < 0.05). Conclusion: For high-risk prostate cancer, IMAT may offer a favorable dose gradient profile, conformity, MU and BOT compared to IMRT.

Understanding the Material Removal Mechanisms of Abrasive Water Jet Drilling Process by Acoustic Emission Technique

  • Kwak, Hyo-Sung;Kovacevic, Radovan
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.03a
    • /
    • pp.40-52
    • /
    • 1998
  • Among the non-traditional machining methods, Abrasive waterjet machining process shows big promise in drilling difficult-to-machine materials due to its numerous advantages such as absence of heat affect zone and thermal distortion. Acoustic emission signal technique is used to understand about material removal mechanisms during abrasive waterjet drilling process. More information about the drilling process is derived through frequency decomposition of auto regressive moving average modeling representing acoustic emission signals.

  • PDF

Hippocampal Sparing Whole Brain Radiotherapy and Integrated Simultaneous Boost vs Stereotactic Radiosurgery Boost: A Comparative Dosimetric Planning Study

  • Cheah, Soon Keat;Matthews, Thomas;Teh, Bin Sing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.9
    • /
    • pp.4233-4235
    • /
    • 2016
  • Background: Whole brain radiotherapy (WBRT) and stereotactic radiosurgery were frequently used to palliate patients with brain metastases. It remains controversial which modality or combination of therapy is superior especially in the setting of limited number of brain metastases. The availability of newer medical therapy that improves survival highlighted the importance of reducing long term radiation toxicity associated with WBRT. In this study, we aim to demonstrate the hippocampal sparing technique with whole brain and integrated simultaneous boost Materials and Methods: Planning data from 10 patients with 1-5 brain metastases treated with SRS were identified. Based on the contouring guideline from RTOG atlas, we identified and contoured the hippocampus with 5mm isocentric expansion to form the hippocampal avoidance structure. The plan was to deliver hippocampal sparing whole brain radiotherapy (HSWBRT) of 30 Gy in 10 fractions and simultaneous boost to metastatic lesions of 30 Gy in 10 fractions each. Results: The PTV, hippocampus and hippocampal avoidance volumes ranges between 1.00 - 39.00 cc., 2.50 - 5.30 cc and 26.47 - 36.30 cc respectively. The mean hippocampus dose for the HSWBRT and HSWBRT and SIB plans was 8.06 Gy and 12.47 respectively. The max dose of optic nerve, optic chiasm and brainstem were kept below acceptable range of 37.5 Gy. Conclusions: The findings from this dosimetric study demonstrated the feasibility and safety of treating limited brain metastases with HSWBRT and SIB. It is possible to achieve the best of both worlds by combining HSWBRT and SIB to achieve maximal local intracranial control while maintaining as low a dose as possible to the hippocampus thereby preserving memory and quality of life.

Infrasound Wave Propagation Characteristics in Korea (국내 인프라사운드 전파특성 연구)

  • 제일영
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.63-69
    • /
    • 2000
  • Korea Institute of Geology Mining and Materials(KIGAM) cooperating with Southern Methodist University(SMU) has been operating seismo-acoustic array in Chul-Won area to discriminate man-made explosions from natural earthquakes since at the end of July 1999. In order to characterize propagation parameters of detected seismo-acoustic signal and to associate these signals as a blast event accompanying seismic and acoustic signals simultaneously it is necessary to understand infrasound wave propagation in the atmosphere. Two comparable Effective Sound Velocity Structures(ESVS) in atmosphere were constructed by using empirical model (MSISE90 and HWM93) and by aerological observation data of Korea Meteorological Administration (KMA) at O-San area. Infrasound propagation path computed by empirical model resulted in rare arival of refracted waves on ground less than 200km from source region. On the other hand Propagation paths by KMA more realistic data had various arrivals at near source region and well agreement with analyzed seismo-acoustic signals from Chul-Won data. And infrasound propagation in specific direction was very influenced by horizontal wind component in that direction. Linear travel time curve drawn up by 9 days data of the KMA in autumn season showed 335.6m/s apparent sound velocity in near source region. The propagation characteristics will be used to associate seismo-acoustic signals and to calculate propagation parameters of infrasound wave front.

  • PDF

The Installation of Chul-Won Seismo-Acoustic Array (철원 지진-공중음파 관측망 설치)

  • ;;;;;;;Brian stump;Christ Hayward
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1999.10a
    • /
    • pp.52-57
    • /
    • 1999
  • Korea Earthquake Monitoring System(KEMS) in the Korea Institute of Geology Mining and Materials(KIGAM) as detected more than 1000 events since the end of 1998. But not all events are interpreted as earthquakes because many events are concentrated on daytime. It strongly implies that in addition to earthquake these events include artificial effects such as industrial blasting. Before the determination of eathquake charactertistics in the korean peninsula it is necessary to discriminate the detected events as earthquakes or artificial events. For the discriminant study KIGAM and SMU(Southern Methodist University) installed a triangular four-element 1-km aperture seismo-acoustic array at Chul-Won area northeast of Seoul Korea. Each array element includes a GS-13 seismometer in the bottom of borehole and a Validyne DP250-14 microbarometer sensor mounted inside of the borehole 1,2 meter deep connected to a 11 arm radial array of 10m porous soaker hoses. This array introduce the use of 2.4-GHz radios for inter-array self-contained solar-charged power system and GPS time-keeping system. A 24-bit digital data acquisition system performs 40 SPS in the infrasound and seismometer data. Velocity and direction of wind and temperature are also measured at hub site and included to the data stresam. This seismo-acoustic array will be used to identify and locate associated with industrial blasting and these identified and located events will be applied to form a ground truth database useful to assist the other development of discriminant studies.

  • PDF

DEVELOPMENT OF FOREIGN ASTRONOMY EDUCATION PROGRAMS : CAMBODIA (해외 천문학 교육 프로그램 개발: 캄보디아)

  • KIM, SANG CHUL;LYO, A-RAN;PARK, CHANGBOM;LEE, JEONG AE;LEE, KANG-HWAN;SHIN, YONG-CHEOL;SHIN, NAEUN;SHIN, ZIHEY;CHOI, YOONHO;KWON, SUN-GILL;KIM, TAEWOO;YOON, HOSEOP;PARK, SOONCHANG;SUNG, EON-CHANG;PAK, SOOJONG
    • Publications of The Korean Astronomical Society
    • /
    • v.34 no.2
    • /
    • pp.17-28
    • /
    • 2019
  • The Korean Astronomical Society (KAS) Education & Public Outreach Committee has provided education services for children and school teachers in Cambodia over the past three years from 2016 to 2018. In the first year, 2016, one KAS member visited Pusat to teach astronomy to about 50 children, and in the following two years of 2017 and 2018, three and six KAS members, respectively, executed education workshops for ~ 20 (per each year) local school teachers in Sisophon. It turned out that it is desirable to include both teaching of astronomical knowledge and making experiments and observations in the education in order for the program to be more effective. Language barrier was the main obstacle in conveying concepts and knowledge, and having a good interpreter was very important. It happens that some languages, such as the Khmer of Cambodia, do not have astronomical terminologies, so that lecturers and even the education participants together are needed to communicate and create appropriate words. Handout hard-copies of the education materials (presentation files, lecture/experiment summaries, terminologies, etc.) are extremely helpful for the participants. Actual performing of assembling and using astronomical telescopes for night sky observations has been lifetime experience for some of the participants, which might promote zeal for knowledge and education. It is hoped that these education services for developing countries like Cambodia can be regularly continued in the future, and further extended to other countries such as Laos and Myanmar.