References
- Corletto D, Iori M, Paiusco M, et al. Inverse and forward optimization of one- and two-dimensional intensitymodulated radiation therapy-based treatment of concaveshaped planning target volumes: the case of prostate cancer. Radiother Oncol 2003;66:185-95. https://doi.org/10.1016/S0167-8140(02)00375-4
- Damen EM, Brugmans MJ, van der Horst A, et al. Planning, computer optimization, and dosimetric verification of a segmented irradiation technique for prostate cancer. Int J Radiat Oncol Biol Phys 2001;49:1183-95. https://doi.org/10.1016/S0360-3016(00)01525-X
- De Meerleer GO, Vakaet LA, De Gersem WR, De Wagter C, De Naeyer B, De Neve W. Radiotherapy of prostate cancer with or without intensity modulated beams: a planning comparison. Int J Radiat Oncol Biol Phys 2000;47:639-48. https://doi.org/10.1016/S0360-3016(00)00419-3
- Wolff D, Stieler F, Welzel G, et al. Volumetric modulated arc therapy (VMAT) vs. serial tomotherapy, step-and-shoot IMRT and 3D-conformal RT for treatment of prostate cancer. Radiother Oncol 2009;93:226-33. https://doi.org/10.1016/j.radonc.2009.08.011
- Cozzi L, Dinshaw KA, Shrivastava SK, et al. A treatment planning study comparing volumetric arc modulation with RapidArc and fixed field IMRT for cervix uteri radiotherapy. Radiother Oncol 2008;89:180-91. https://doi.org/10.1016/j.radonc.2008.06.013
- Goulet CC, Herman MG, Hillman DW, Davis BJ. Estimated limits of IMRT dose escalation using varied planning target volume margins. Phys Med Biol 2008;53:3777-88. https://doi.org/10.1088/0031-9155/53/14/005
- Chen ME, Johnston DA, Tang K, Babaian RJ, Troncoso P. Detailed mapping of prostate carcinoma foci: biopsy strategy implications. Cancer 2000;89:1800-9. https://doi.org/10.1002/1097-0142(20001015)89:8<1800::AID-CNCR21>3.0.CO;2-D
- Epstein JI, Walsh PC, Carmichael M, Brendler CB. Pathologic and clinical findings to predict tumor extent of nonpalpable (stage T1c) prostate cancer. JAMA 1994;271:368-74. https://doi.org/10.1001/jama.1994.03510290050036
- Kassim I, Dirkx ML, Heijmen BJ. Evaluation of the dosimetric impact of non-exclusion of the rectum from the boost PTV in IMRT treatment plans for prostate cancer patients. Radiother Oncol 2009;92:62-7. https://doi.org/10.1016/j.radonc.2009.02.004
- Zelefsky MJ, Fuks Z, Happersett L, et al. Clinical experience with intensity modulated radiation therapy (IMRT) in prostate cancer. Radiother Oncol 2000;55:241-9. https://doi.org/10.1016/S0167-8140(99)00100-0
- Zhu X, Ge Y, Li T, Thongphiew D, Yin FF, Wu QJ. A planning quality evaluation tool for prostate adaptive IMRT based on machine learning. Med Phys 2011;38:719-26. https://doi.org/10.1118/1.3539749
- Appenzoller LM, Michalski JM, Thorstad WL, Mutic S, Moore KL. Predicting dose-volume histograms for organs-at-risk in IMRT planning. Med Phys 2012;39:7446-61. https://doi.org/10.1118/1.4761864
- Moore KL, Brame RS, Low DA, Mutic S. Experience-based quality control of clinical intensity-modulated radiotherapy planning. Int J Radiat Oncol Biol Phys 2011;81:545-51. https://doi.org/10.1016/j.ijrobp.2010.11.030
- Zelefsky MJ, Harrison A. Neoadjuvant androgen ablation prior to radiotherapy for prostate cancer: reducing the potential morbidity of therapy. Urology 1997;49(3A Suppl):38-45. https://doi.org/10.1016/S0090-4295(97)00168-4
- Gauthier I, Carrier JF, Beliveau-Nadeau D, Fortin B, Taussky D. Dosimetric impact and theoretical clinical benefits of fiducial markers for dose escalated prostate cancer radiation treatment. Int J Radiat Oncol Biol Phys 2009;74:1128-33. https://doi.org/10.1016/j.ijrobp.2008.09.043
- Azcona JD, Li R, Mok E, Hancock S, Xing L. Automatic prostate tracking and motion assessment in volumetric modulated arc therapy with an electronic portal imaging device. Int J Radiat Oncol Biol Phys 2013;86:762-8. https://doi.org/10.1016/j.ijrobp.2013.03.007
- Das S, Liu T, Jani AB, et al. Comparison of image-guided radiotherapy technologies for prostate cancer. Am J Clin Oncol 2013 Feb 20 [Epub]. http://dx.doi.org/10.1097/COC.0b013e31827e4eb9.
- Yang Y, Ford EC, Wu B, et al. An overlap-volume-histogram based method for rectal dose prediction and automated treatment planning in the external beam prostate radiotherapy following hydrogel injection. Med Phys 2013;40:011709. https://doi.org/10.1118/1.4769424
- Susil RC, McNutt TR, DeWeese TL, Song D. Effects of prostaterectum separation on rectal dose from external beam radiotherapy. Int J Radiat Oncol Biol Phys 2010;76:1251-8. https://doi.org/10.1016/j.ijrobp.2009.07.1679
- Pinkawa M, Corral NE, Caffaro M, et al. Application of a spacer gel to optimize three-dimensional conformal and intensity modulated radiotherapy for prostate cancer. Radiother Oncol 2011;100:436-41. https://doi.org/10.1016/j.radonc.2011.09.005
- Marks LB, Yorke ED, Jackson A, et al. Use of normal tissue complication probability models in the clinic. Int J Radiat Oncol Biol Phys 2010;76(3 Suppl):S10-9. https://doi.org/10.1016/j.ijrobp.2009.07.1754
- Breitman K, Rathee S, Newcomb C, et al. Experimental validation of the Eclipse AAA algorithm. J Appl Clin Med Phys 2007;8:76-92.
- Rodgers JL, Nicewander AW. Thirteen ways to look at the correlation coefficient. Am Stat 1988;42:59-66.
- Mohan R, Wang X, Jackson A, et al. The potential and limitations of the inverse radiotherapy technique. Radiother Oncol 1994;32:232-48. https://doi.org/10.1016/0167-8140(94)90023-X
- Hunt MA, Jackson A, Narayana A, Lee N. Geometric factors influencing dosimetric sparing of the parotid glands using IMRT. Int J Radiat Oncol Biol Phys 2006;66:296-304. https://doi.org/10.1016/j.ijrobp.2006.05.028
- Vineberg KA, Eisbruch A, Coselmon MM, McShan DL, Kessler ML, Fraass BA. Is uniform target dose possible in IMRT plans in the head and neck? Int J Radiat Oncol Biol Phys 2002;52:1159-72. https://doi.org/10.1016/S0360-3016(01)02800-0
- Wu B, Ricchetti F, Sanguineti G, et al. Patient geometry-driven information retrieval for IMRT treatment plan quality control. Med Phys 2009;36:5497-505. https://doi.org/10.1118/1.3253464
- Wu B, McNutt T, Zahurak M, et al. Fully automated simultaneous integrated boosted-intensity modulated radiation therapy treatment planning is feasible for head-and-neck cancer: a prospective clinical study. Int J Radiat Oncol Biol Phys 2012;84:e647-53. https://doi.org/10.1016/j.ijrobp.2012.06.047
- Cheung MR, Tucker SL, Dong L, et al. Investigation of bladder dose and volume factors influencing late urinary toxicity after external beam radiotherapy for prostate cancer. Int J Radiat Oncol Biol Phys 2007;67:1059-65. https://doi.org/10.1016/j.ijrobp.2006.10.042
- Michalski JM, Gay H, Jackson A, Tucker SL, Deasy JO. Radiation dose-volume effects in radiation-induced rectal injury. Int J Radiat Oncol Biol Phys 2010;76(3 Suppl):S123-9. https://doi.org/10.1016/j.ijrobp.2009.03.078
Cited by
- Modulation index for VMAT considering both mechanical and dose calculation uncertainties vol.60, pp.18, 2014, https://doi.org/10.1088/0031-9155/60/18/7101
- The effect of extremely narrow MLC leaf width on the plan quality of VMAT for prostate cancer vol.11, pp.None, 2016, https://doi.org/10.1186/s13014-016-0664-0
- Dosimetric Validation of the Acuros XB Advanced Dose Calculation Algorithm for Volumetric Modulated Arc Therapy Plans vol.27, pp.4, 2014, https://doi.org/10.14316/pmp.2016.27.4.180
- Optimal Density Assignment to 2D Diode Array Detector for Different Dose Calculation Algorithms in Patient Specific VMAT QA vol.42, pp.1, 2014, https://doi.org/10.14407/jrpr.2017.42.1.9
- Simultaneous optimization of mixed photon energy beams in volumetric modulated arc therapy vol.46, pp.9, 2014, https://doi.org/10.1002/mp.13700
- Implementation of an optimization method for parotid gland sparing during inverse planning for head and neck cancer radiotherapy vol.24, pp.1, 2020, https://doi.org/10.1016/j.canrad.2019.09.006
- Tree-based exploration of the optimization objectives for automatic cervical cancer IMRT treatment planning vol.94, pp.1123, 2014, https://doi.org/10.1259/bjr.20210214
- Multi-criteria optimization for planning volumetric-modulated arc therapy for prostate cancer vol.16, pp.9, 2021, https://doi.org/10.1371/journal.pone.0257216