• 제목/요약/키워드: Method of displacement

검색결과 4,852건 처리시간 0.039초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

전흉벽 늑연골의 리모델링 성형술을 이용한 누두흉수술의 임상적 고찰 초기합병증 (Clinecal Investigation and Acute Complications of Remodelling Plasty of Costochondral Rib Cage For Pectus Excavatum)

  • 허균;송철민;전철우;장원호;김현조;정윤섭;염욱
    • Journal of Chest Surgery
    • /
    • 제35권12호
    • /
    • pp.882-889
    • /
    • 2002
  • 누두흉 환자에 대해 최소침습적 방법으로 전흉벽 늑연골의 리모델링 성형술이 선호되고 있다. 본원에서 시행한 누두흉 환자들을 대상으로 늑연골의 리모델링 성형술의 시행시 발생할 수 있는 초기 합병증의 종류와 이에 대한 치료법의 연구이다. 대상 및 방법: 본원에서 1999년 9월에서부터 2002년 2월까지 오목가슴으로 인해 늑연골의 리모델링 성형술을 시행받은 55명을 대상으로 의무기록을 중심으로 후향적 분석을 시행하였다. 입원기간, 수술 후 관리, 수술 후 한 달 내에 발생한 합병증과 치료 방법 등을 분석하였다. 결과: 입원일은 5일에서 29일(8.6$\pm$4.2일)이었고 특별한 합병증이 없어도 퇴원하는 날까지 단순흥부촬영을 매일 시행하였으며 55명중 수술 후 합병증이 발생한 환자는 28명(51%)이었으며 기흉이 11명(20%), 혈흉이 6명(11%), 혈기흉이 3명(5%)이었으며 그 외 폐렴 및 무기폐등이 발생하였고 이중 3명(3%)은 상기 합병증과 더불어 철심의 변위 및 상처감염이 발생하였다. 28명의 합병증이 발생한 환자들 중 흉관삽입술이나 치료가 필요했던 환자들은 7명(13%)이었다. 결론: 늑연골의 리모델링 성형술후에 발생하는 합병증과 그의 치료에 대해 대부분의 환자들에서는 특별한 치료가 필요하지 않았으나 좀더 오랜 기간 추적관찰이 필요하다.

두 발의 위치에 따른 체형검사 결과 차이와 체간신전 동작 이미지 검사의 유용성 연구 (Study on the Differences in the Results of Body Shape Test According to the Position of the Two Feet and the Usefulness of the Neck and Body Motion Image Test)

  • 장완성;김송자;류서원;임덕준;정문영
    • 한국자연치유학회지
    • /
    • 제9권1호
    • /
    • pp.22-26
    • /
    • 2020
  • 목적: 본 연구는 체형검사 시 피험자의 선 자세(standing position)에서 두 발을 벌려 선 자세(normal standing position: NSP)와 두 발을 붙여 선 자세(straight standing position: SSP)가 각각 다른 체형검사 결과를 나타낼 수 있는지에 대하여 연구하고, 이미지 검사장치의 위치에 따라서도 다른 체형검사 결과를 나타낼 수 있는지에 대하여 연구하는 것이 목적이었다. 연구방법: NSP와 SSP에서 이미지 검사를 하여 두 자세의 사례 1과 사례 2의 인체형태를 비교하였다. 검사 시 카메라의 위치는 피검자의 후방 45 cm 지점에서 수직으로 2.3 m 위치의 카메라가 피검자 후면의 머리, 어깨, 등, 허리, 엉덩이, 종아리, 발뒤꿈치가 모두 포함되는 이미지를 캡처하였다. 캡처 시 피검자의 앞가슴이 나타나지 않도록 하였다. 결과: 체형검사 시 해부학적 자세의 생리적 특성은 생체이며, 이에 따라 인체의 후면이 보이게 수평면으로 관찰 하는 경우 NSP와 SSP 체형검사 결과 골반의 전방경사와 회전변위 이미지가 다르게 나타났다. 체간 신전 검사 결과에서 어깨, 팔, 목 주변 근육의 변형이 관찰되었다. 결론: 검사 시 NSP와 SSP의 골반의 위치 결과 이미지는 골반변위와 골반경사각이 다르게 평가되며, 체간의 신전을 유도하여 최대 신전 범위에서의 검사법에서 어깨 전면부 근육의 좌우 단축을 관찰 할 수 있는 것으로 나타나 체간의 신전을 유도하여 검사하는 방법도 유용한 방법으로 평가된다.

요수근 관절의 골절-탈구에서 단요월상인대의 손상 형태에 따른 치료 결과의 비교 (Comparison of the Outcomes according to the Injury Type of the Short Radiolunate Ligament in Fracture-Dislocation of the Radiocarpal Joint)

  • 허윤무;김태균;송재황;장민구;이석원
    • 대한정형외과학회지
    • /
    • 제56권1호
    • /
    • pp.51-60
    • /
    • 2021
  • 목적: 요수근 관절 탈구는 고에너지 손상에 의해 발생하며 요골 경상돌기 골절 및 단요월상인대 손상을 동반한다. 단요월상인대는 요골 부착부에서 파열되기도 하지만 요골 월상골와의 전방연에서 견열 골편을 동반하여 발생하기도 한다. 이 연구의 목적은 요골 경상돌기 골절이 동반된 요수근 관절 탈구에서 단요월상인대의 손상 형태 및 치료 방법에 따라 결과의 차이가 있는지 알아보고자 한다. 대상 및 방법: 요수근 관절 탈구로 수술을 시행한 18명을 대상으로 하였다. 요수근 관절 탈구는 Dumontier 등의 방법을 이용하여 Group 1 (순순한 탈구 또는 요골의 작은 견열 골절)과 Group 2 (주상골와의 1/3 이상을 침범한 요골 경상돌기 골절)로 분류하였다. Group 2는 단요월상인대의 부착부가 파열되거나 작은 견열 골절을 동반한 경우를 2A, 비교적 큰 견열 골절을 동반하여 내고정이 가능한 경우를 2B로 분류하였다. 전자는 단요월상인대의 직접 봉합으로, 후자는 작은 나사를 이용한 견열 골편의 내고정으로 치료하였다. 최종 추시에서 통증, 관절 운동 범위와 파악력, 영상 검사를 확인하였다. 치료 결과는 patient-rated wrist evaluation(PRWE), modified Mayo wrist score (MMWS)를 이용하여 평가하였다. 결과: 모든 증례는 Group 2 (2A 6명, 2B 12명)로 분류되었다. 굴신 운동 범위는 건측의 79%, 파악력은 72.9%를 보였다. Group 2A가 2B보다 신전/굴곡/회전에서 더 큰 운동 범위를 보였다. 요사위/척사위/회외전과 통증, 파악력 회복은 차이는 없었다. PRWE, MMWS에서는 두 군의 차이가 없었다. 합병증으로 외상성 관절염 7예, 관절 불안정 5예가 있었다. 결론: 단요월상인대가 손상될 때 요골 월상골와의 전방연에서 발생한 견열 골절은 치료 결과에 영향이 없었다. 그러나 견열 골편이 전위되거나 회전되어 탈구의 정복을 방해하기 때문에 주의해야 하며, 골편에 부착하는 단요월상인대의 기능을 복원하기 위해 해부학적 정복과 견고한 내고정이 필요하다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

구강안면통증 환자의 치료결과와 예후에 관한 연구 (Treatment Outcome and Prognosis of the Outpatients with Orofacial Pain)

  • 최세헌;김기석;김미은;이동주;진상배
    • Journal of Oral Medicine and Pain
    • /
    • 제31권2호
    • /
    • pp.155-165
    • /
    • 2006
  • 본 연구는 단국대학교 치과대학 부속병원 구강내과에 내원한 측두하악장애 환자를 포함한 구강안면동통 환자들을 대상으로 치료의 결과와 예후를 평가하기 위하여, 2002년 1월부터 2004년 12월까지 3년간 (치아질환을 제외한) 구강안면동통 환자 6300명 중에서 진료기록부 상에서 경과기록을 확인할 수 있는 환자들을, 측두하악장애, 신경병성동통장애, 연조직질환 및 이 중 둘 이상을 질환을 동시에 가지고 있는 복합질환으로 나누어 치료기간, 치료유형 및 치료효과를 비교하여 다음의 결과를 얻었다. 1. 평균 진료기간은 신경병성 동통장애에서 가장 길었고 연조직질환, 복합 질환, 관절장애, 근육-관절 복합장애, 근육장애의 순이었다. 2. 사용된 치료방법을 비교하면 약물요법은 연조직질환과 신경병성 동통장애에서, 장치요법은 관절장애군에서, 물리치료는 근육장애군에서 사용빈도가 높았다. 3. 진단분류별 물리치료의 사용경향은 근육장애군은 EAST와 초단파요법의 사용빈도가 높았고, 관절장애군은 초음파 치료, 신경병성 동통 장애와 연조직 질환은 저출력 레이저 요법이 많이 사용되었다. 4. 통증에 대한 치료결과는 통증이 지속되는 경향이 신경병성 동통장애에서 가장 높았으며, 완화되거나 완전 소실되는 경향은 측두하악장애에서 높았다. 5. 측두하악장애 환자에서 근육장애, 정복성 관절원판장애, 비정복성 관절원판 장애 및 근육-관절 복합장애 세분하여 치료 후 개구량의 변화를 조사하였을 때는 진단군 간에 유의한 차이를 볼 수 없었으나 개구량 측정방법간에는 무통성 최대개구량이 치료 후 가장 증가하였고, 환자 스스로가 벌리는 능동적 최대개구량은 비정복성관절원판장애에서 가장 증가하였다. 이상의 결과로 볼 때, 구강안면통증 영역에서 현재 시행하고 있는 치료법들은 측두하악장애에서는 동통조절 및 기능개선에 좋은 결과를 보여주고 있으므로 그 예후가 좋은 반면, 연조직질환이나 신경계 질환 같은 기타의 구강안면통증은 길고 지속적인 치료를 요구하는 어려운 질환이라고 할 수 있겠다.

모형실험을 통한 암반사면의 파괴거동에 대한 연구 (Investigation of Rock Slope Failures based on Physical Model Study)

  • 조태진;석재욱;이성암;엄정기
    • 지질공학
    • /
    • 제18권4호
    • /
    • pp.447-457
    • /
    • 2008
  • 절리면의 거칠기, 충전물 등의 공학적 특성과 활동면 경사, 수압하중을 고려하여 암반사면의 파괴거동을 고찰하고 파괴시기를 예측하기 위하여 모형실험이 수행되었다. 절리면 거칠기는 폭, 길이, 높이 등을 고려하여 톱니형으로 제작하였다. 충전물은 거칠기의 돌출부 높이에 대하여 일정한 충전물두께를 유지하는 방식으로 0에서 돌출부 높이의 1.2배까지 증가시켰다. 수압증가에 따른 사면의 거동양상을 파악하기 위해서는 인장균열에 완전히 가해질 수 있는 수압을 100%로 하여 0.5%/min 및 1%/min의 속도로 0%에서 파괴 시 까지 수압하중을 증가시켰다. 모형실험은 활동면 경사각 $30^{\circ}$$35^{\circ}$에서 각각 거칠기, 충전물 두께, 수압하중증가 등의 조합을 변화시키면서 총 50회 수행하였다. 모형실험결과 절리면의 거칠기가 없는 경우의 파괴거동 양상은 수압하중 증가 조건과 충전물의 유무에 관계없이 선형 변위거동으로 나타나는 것이 특징적이다. 거칠기가 존재할 경우에는 충전물 두께가 거칠기 높이보다 낮을 때 계단형 변위거동이, 거칠기 높이 이상일 때 지수형 변위거동이 특징적이다. 이는 충전물 두께가 거칠기의 높이를 넘어서면 절리면의 거동특성이 충전물의 공학적 특성에 좌우되기 때문인 것으로 판단된다. 파괴를 유발하는 수압하중의 크기는 절리면의 거칠기가 증가함에 따라 증가한다. 충전물의 두께가 증가할수록 거칠기의 영향이 작아져 파괴 시 수압하중은 감소한다 파괴가 임박한 시점에서 3차 크립 형태의 변위거동을 보이는 지수형의 경우에는 inverse velocity를 이용한 파괴시기 예측이 가능한 것으로 판단된다. 다만 실험에서 나타난 거동특성이 완전한 지수형이 아니고 계단형과 지수형의 중간형태로 나타나는 경우가 대부분이므로 정확한 파괴시기 예측을 위해서는 다수에 걸친 파괴시간 추정이 필요할 것으로 사료된다.

양호한 연속체 암반사면의 예비 판정기준 설정 연구 (A Study on Setup for Preliminary Decision Criterion of Continuum Rock Mass Slope with Fair to Good Rating)

  • 김형민;이수곤;이벽규;우재경
    • 지질공학
    • /
    • 제29권2호
    • /
    • pp.85-97
    • /
    • 2019
  • 암반으로 구성되어 있는 급경사($65{\sim}80^{\circ}$) 암반사면들이 장기간 안정한 상태로 유지되고 있는 것을 관찰할 수 있다. 이와 유사한 지반상태로 이루어진 굴착 암반사면에서 불연속구조가 비탈면의 안정성에 유리한 방향으로 분포하고 있는 경우에는 발파암 경사기준인 1 : 0.5 ($63^{\circ}$)보다 급한 경사를 적용할 수 있을 것이다. 비탈면 설계기준의 경사 결정 과정에서 급경사로 적용할 수 있는 예비 암반조건이 정량적으로 설정되어 있으면 설계 실무측면에서 지침으로 활용할 수 있을 것이다. 이 연구에서는 상기 암반을 양호한 연속체 암반으로 정의하고, 양호한 연속체 암반조건에 대해 공학적인 준거를 제공할 목적으로 범용적인 RMR, SMR, GSI 분류를 활용하여 정량적인 설정기준 범위를 제안하고자 하였다. 연구방법으로는 다음과 같다. 암석종류별로 급경사 $65{\sim}80^{\circ}$)에서 안정한 비탈면을 연구 대상으로 선정하고, Face mapping 결과를 반영하여 RMR과 SMR 및 GSI 분류하였다. Hoek-Brown 파괴기준을 활용하여 산정된 강도정수를 현 상태의 암반사면 안정해석에 적용하여 나타난 결과를 검토하였다. 급경사로 안정하게 유지되는 지반조건으로서 예비기준의 타당성을 검증하기 위한 것이다. 상기 연구방법으로 분석 검토한 결과, 양호한 연속체 암반비탈면은 Basic RMR ${\geq}50$ (퇴적암에서는 45), GSI SMR ${\geq}45$로 설정할 수 있을 것으로 분석되었다. 한계평형 해석의 안전율은 Fs = 14.08~67.50 (평균 32.9)이고, 유한요소해석의 변위는 0.13~0.64 mm (평균 0.27 mm)이다. 이는 급경사($65{\sim}80^{\circ}$)로 오랜 기간 동안 안정하게 유지되고 있는 양호한 연속체 암반사면의 안정성을 정량적으로 표현하고 확인하는 결과로 볼 수 있다. 양호한 연속체 암반사면에 대한 암반기준 설정범위는 자료가 축적되면 좀 더 세부적인 설정기준을 확립할 수 있을 것이고 추후 연구과제이기도 하다. 1 : 0.1~0.3의 급경사에서도 안정할 경우에, 해외 설계기준 및 사례를 참고하여 급경사의 상한 기준을 1 : 0.3으로 설계하면 경제성과 친환경성을 확보하는 이점이 있게 된다. 또한 굴착기술과 식생기술 발달 및 다양한 친환경적 사면 설계기법으로 급경사에 따른 심리적 불안감과 급격한 지반이완을 극복할 수 있을 것이다.

치아의 활주 이동시 브라켓 폭이 브라켓과 호선 사이의 마찰력에 미치는 효과 (The effect of bracket width on frictional force between bracket and arch wire during sliding tooth movement)

  • 최원철;김태우;박주영;곽재혁;나효정;박두남
    • 대한치과교정학회지
    • /
    • 제34권3호
    • /
    • pp.253-260
    • /
    • 2004
  • 치아의 활주 이동시 교정용 브라켓과 호선 사이의 마찰력은 많은 요인들, 예를 들면 브라켓과 호선의 크기, 형태 그리고 재료, 결찰방법 그리고 브라켓-호선간 각도 등과 관련이 있다. 이런 요인들 대부분에 관하여 명확한 결론이 내려져 있지만 브라켓 폭이 마찰력에 미치는 효과에 관해서는 논란이 있다. 이번 연구는 임상에서와 비슷한 모의 치아 이동시 브라켓 폭이 발생되는 마찰력의 양에 미치는 효과를 조사하기 위해 고안되었다. 폭이 다른 세 가지 브라켓 $(0.018{\times}0.025\;standard)$ 즉 좁은 것 (2.40mm), 중간 것 (3.00mm), 그리고 넓은 것(4.25mm) 등을 $0.016{\times}0.022$ 스테인레스 스틸 호선과 함께 사용하였다 세 가지 브라켓-호선 조합들은 분속 0.5mm로 4분 동안 장치 에서 움직이도록 하였고 각각 7회씩 반복 측정하였다. 생물학적인 상태를 재현하기 위해 치 아 치조 모형은 치근막과 유사한 탄성을 갖는 재료를 이용하는 간접법으로 제작되었다. 게다가 결찰력의 효과를 최소화하기 위하여 브라켓에 레진을 덧붙여서 고무로 결찰함으로써 브라켓 폭의 차이를 보상해주었다. 결과는 다음과 같다: 1. 각 브라켓-호선 조합의 최대 마찰력은; 좁은것(2.40mm): $m4.69gmf$ 중간것 (3.00mm): $72.7\pm54.98gmf$ 넓은것(4.25mm): $72.5\pm94.54gmf$ 2. 호선이 브라켓 슬롯을 지나서 나아갈수록 마찰력은 증가하였다. 3. ANOVA 사후검정 결과 임상과 비슷한 모의 실험에서 브라켓 폭은 마찰력에 아무런 영향을 미치지 않았다(p>0.05).

의료영상 분석과 유한요소법을 통한 추체 성형술의 다양한 인자들에 대한 생체 역학적 효과 분석 (A Biomechanical Study on the Various Factors of Vertebroplasty Using Image Analysis and Finite Element Analysis)

  • 전봉재;권순영;이창섭;탁계래;이권용;이성재
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권3호
    • /
    • pp.171-182
    • /
    • 2004
  • 본 연구에서는 의료 영상과 유한요소 해석을 이용하여 골절된 척추체의 치료를 위해 골 시멘트를 주입하는 추체 성형술(vertebroplasty)에 영향을 미치는 여러 인자들에 대해 생체 역학적으로 분석하여 평가하고자 하였다. 의료 영상을 통해 구현된 모델들은 분석하고자 하는 인자에 대하여 크게 단분절과 다분절 유한요소 모델의 2 가지 형태로 구분하였다. 단분절 유한요소 모델을 통해 골다공증의 정도, 주입된 골 시멘트의 양, 골 시멘트의 주입량 및 환자에게 주입된 골 시멘트 양의 적절성을 평가하였으며, 골 시멘트의 주입이 척추체의 구조적 안정성에 미치는 효과를 분석하기 위하여 척추체 상종판에 수직 압축하중을 가하여 이때의 최대 수진 변위량을 분석하였다. 또한 단분절 척추체의 강성도(stiffness) 값을 산출한 뒤, 정상 상태의 척추체의 강성도 값으로 정규화 하였다. 다분절 유한요소 모델의 경우, 압박 골절 상태를 적용하여 척추 만곡의 변화가 인체에 미치는 영향을 분석하기 위하여 골절의 정도를 3 가지로 구현하였으며, 모델의 최상부에 압축 하중을 가한 후의 척추 만곡의 변화 정도를 분석하였다. 추체 성형술에 대한 다양한 인자들에 대한 분석 결과, 추체 성형술을 통해 환자의 골밀도가 상대적으로 높은 경우(BMD 50mg/$m\ell$이상)와 환자의 척추체 망상골 부피의 약 15%에 해당하는 골 시멘트 주입 시 가장 큰 척추체의 구조적 안정성의 증가 효과를 가져올 것으로 예측되었다. 또한 척추 골절이 미치는 영향에 대한 분석 결과, -2.8$^{\circ}$의 정상적인 후만곡을 가지는 T12∼L2 운동 분절이 골절의 모델링 후 약 9∼17$^{\circ}$의 큰 전만곡을 가지게 되었으며 이러한 척추 만곡의 변화는 동일한 하중 하에서 급격한 척추 만곡의 변화를 야기하는 것으로 나타났다. 또한 골절의 정도가 심할수록 척추 변형은 더욱 크게 증가하는 것으로 나타났다. 이러한 연구 결과들로부터, 전반적으로 추체 성형술은 골 시멘트의 주입량 또는 골밀도에 상관없이 약화된 척추체의 자체의 구조적 안정성의 증가 효과를 가져왔으며 골절로 인해 추체의 높이가 손상되었을 경우 이를 회복하는 것이 중요한 인자의 하나임을 나타내는 결과로 사료되어진다.