• Title/Summary/Keyword: Method comparison

Search Result 14,585, Processing Time 0.041 seconds

An Effect of the Selection of Excellent Design Product on the Business Performance in the Start-up: Focusing on 2013, 2014 and 2015 Design Awarded Companies (우수디자인제품 선정이 창업기업 경영성과에 미치는 영향: 2013년, 2014년, 2015년 우수디자인제품 선정기업들 중심으로)

  • Yoo, joung houn;Bae, byung Yun;Jeon, Ki suk
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.13 no.4
    • /
    • pp.211-216
    • /
    • 2018
  • This study was intended to analyze the effects of the selection of excellent design product by the KIDP(Korea Institute of Design Promotion) on the business performance of the company focused on the start-up with relatively low competitiveness. According to the statistics of KIDP in 2013, a design accounted for 27.53% of the factors affecting the sales of products and a design was the most important factor among the factors affecting the sales of products for the small sized company in terms of the scale of company. In addition, looking at the trend by industry in the data collected for this study, the technology-based industry showed a relatively higher growth rate than the retail industry and other industries. In this study, the author surveyed 186 companies of the companies that recognized the importance of design in difficult management conditions and received excellent design product certificate from KIDP(2013, 2014 and 2015) and empirically verified whether there was any difference in business performance between the start-ups with a business history of less than 7 years and the ongoing firms with a business history of more than 7 years. To evaluate the value of design, we used analytical method of measuring related values by comparison between groups. In addition, we also analyzed the difference in business performance(sales) between manufacturing companies, where the role of design was relatively large, and non-manufacturing companies among companies that received the excellent design product certificate. We have established a study hypothesis that the selection of excellent design product by the KIDP would have more positive effect on the business performance(sales) of the start-up compared to the ongoing firm, and conducted an empirical analysis by comparing both the year before and the year after the selected year. As a result, we found that the selection of excellent design product by the KIDP has a positive effect on the business performance of the start-up, and the selection of excellent design product has a significant effect on the difference in business performance between manufacturing and non-manufacturing companies. This study was conducted in the hope that the government actively supports the design-related policies so that the selection of excellent design product become an important indicator of the business performance of the start-up, and thus the design management will be a way to enhance the competitiveness of the start-up.

Development of Automated Region of Interest for the Evaluation of Renal Scintigraphy : Study on the Inter-operator Variability (신장 핵의학 영상의 정량적 분석을 위한 관심영역 자동설정 기능 개발 및 사용자별 분석결과의 변화도 감소효과 분석)

  • 이형구;송주영;서태석;최보영;신경섭
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.41-50
    • /
    • 2001
  • The quantification analysis of renal scintigraphy is strongly affected by the location, shape and size of region of interest(ROI). When ROIs are drawn manually, these ROIs are not reproducible due to the operators' subjective point of view, and may lead to inconsistent results even if the same data were analyzed. In this study, the effect of the ROI variation on the analysis of renal scintigraphy when the ROIs are drawn manually was investigated, and in order to obtain more consistent results, methods for automated ROI definition were developed and the results from the application of the developed methods were analyzed. Relative renal function, glomerular filtration rate and mean transit time were selected as clinical parameters for the analysis of the effect of ROI and the analysis tools were designed with the programming language of IDL5.2. To obtain renal scintigraphy, $^{99m}$Tc-DTPA was injected to the 11 adults of normal condition and to study the inter-operator variability, 9 researchers executed the analyses. The calculation of threshold using the gradient value of pixels and border tracing technique were used to define renal ROI and then the background ROI and aorta ROI were defined automatically considering anatomical information and pixel value. The automatic methods to define renal ROI were classified to 4 groups according to the exclusion of operator's subjectiveness. These automatic methods reduced the inter-operator variability remarkably in comparison with manual method and proved the effective tool to obtain reasonable and consistent results in analyzing the renal scintigraphy quantitatively.

  • PDF

Effects of Iterative Reconstruction Algorithm, Automatic Exposure Control on Image Quality, and Radiation Dose: Phantom Experiments with Coronary CT Angiography Protocols (반복적 재구성 알고리즘과 관전류 자동 노출 조정 기법의 CT 영상 화질과 선량에 미치는 영향: 관상동맥 CT 조영 영상 프로토콜 기반의 팬텀 실험)

  • Ha, Seongmin;Jung, Sunghee;Chang, Hyuk-Jae;Park, Eun-Ah;Shim, Hackjoon
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.28-35
    • /
    • 2015
  • In this study, we investigated the effects of an iterative reconstruction algorithm and an automatic exposure control (AEC) technique on image quality and radiation dose through phantom experiments with coronary computed tomography (CT) angiography protocols. We scanned the AAPM CT performance phantom using 320 multi-detector-row CT. At the tube voltages of 80, 100, and 120 kVp, the scanning was repeated with two settings of the AEC technique, i.e., with the target standard deviations (SD) values of 33 (the higher tube current) and 44 (the lower tube current). The scanned projection data were reconstructed also in two ways, with the filtered back projection (FBP) and with the iterative reconstruction technique (AIDR-3D). The image quality was evaluated quantitatively with the noise standard deviation, modulation transfer function, and the contrast to noise ratio (CNR). More specifically, we analyzed the influences of selection of a tube voltage and a reconstruction algorithm on tube current modulation and consequently on radiation dose. Reduction of image noise by the iterative reconstruction algorithm compared with the FBP was revealed eminently, especially with the lower tube current protocols, i.e., it was decreased by 46% and 38%, when the AEC was established with the lower dose (the target SD=44) and the higher dose (the target SD=33), respectively. As a side effect of iterative reconstruction, the spatial resolution was decreased by a degree that could not mar the remarkable gains in terms of noise reduction. Consequently, if coronary CT angiogprahy is scanned and reconstructed using both the automatic exposure control and iterative reconstruction techniques, it is anticipated that, in comparison with a conventional acquisition method, image noise can be reduced significantly with slight decrease in spatial resolution, implying clinical advantages of radiation dose reduction, still being faithful to the ALARA principle.

First-pass Stress Perfusion MR Imaging Findings of Apical Hypertrophic Cardiomyopathy: with Relation to LV Wall Thickness and Late Gadolinium-enhancement (심첨형 비후성 심근병증에서의 스트레스 부하 관류 자기공명영상 소견: 좌심실 벽 비후 정도와 지연 조영 증강 간의 관련성)

  • Yoo, Jin Young;Chun, Eun Ju;Kim, Yeo-Koon;Choi, Sang Il;Choi, Dong-Ju
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.7-16
    • /
    • 2014
  • Purpose : To evaluate the prevalence and pattern of perfusion defect (PD) on first-pass stress perfusion MR imaging in relation with the degree of left ventricular hypertrophy (LVH) and late gadolinium-enhancement (LGE) in patients with apical hypertrophic cardiomyopathy (APH). Materials and Methods: Cardiac MR imaging with first-pass stress perfusion, cine, and LGE sequence was performed in 26 patients with APH from January 2008 to December 2012. We analyzed a total of 416 segments for LV wall thickness on end-diastolic phase of cine images, and evaluated the number of hypertrophied segment and number of consecutive hypertrophied segment (NCH). We assessed the presence or absence of PD and LGE from all patients. If there was PD, we subdivided the pattern into sporadic (sporadic-PD) or ring (ring-PD). Using univariate logistic method, we obtained the independent predictor for presence of overall PD and ring-PD. Results: PD on stress perfusion MRI was observed in 20 patients (76.9%), 12 of them (60%) showed ring-PD. Maximal LV wall thickness and number of hypertrophied segment were independent predictors for overall PD (all, p < 0.05). NCH with more than 3 segments was an additional independent factor for ring-PD. However, LGE was not statistically related with PD in patients with APH. Conclusion: About three quarters of the patients with APH showed PD, most of them represented as ring-PD. LVH degree or distribution was related with pattern of PD, however, LGE was not related with PD. Therefore, the clinical significance of PD in the patients with APH seems to be different from those with non-APH, and further comparison study between the two groups should be carried out.

Comparison of TME Values of Imported Corns and ME Values Determined by In vitro Method (수입 옥수수들의 TME가와 In vitro 방법에 의해 측정한 ME가의 비교)

  • Cho, J.H.;Paik, I.K.;Hyun, Y.
    • Journal of Animal Science and Technology
    • /
    • v.49 no.6
    • /
    • pp.737-744
    • /
    • 2007
  • An experiment was conducted to compare the ME values of imported corns measured by In vivo(TME) and In vitro(MEn, ME and MEpc) methods and to investigate the true amino acid availability(TAAA) and the true nutrient availability(TNA) of imported corns. For TME assay, twenty four 57-weeks-old Hy-Line roosters were assigned to fasting group(4 roosters) and four corn groups(5 roosters each): USA; corn produced in the United States, ARG; corn produced in Argentina, CHN; regular corn produced in China, CHNP; premium corn produced in China. The MEn, ME and MEpc values were determined by equations based on chemical analysis. The TME value of USA(3,745kcal/kg) in as fed basis was significantly (P<0.01) higher than ARG(3,555kcal/kg) and CHNP(3,518kcal/kg) but was not significantly different from CHN(3,671kcal/kg). The TME value of USA(4,144kcal/kg) in DM basis was not significantly different from CHN(4,060kcal/kg) and CHNP(4,008kcal/kg) but was significantly(P<0.05) higher than ARG(4,001kcal/kg). There were significant differences in TAAA of phenylalanine, histidine and arginine among imported corns. Those of USA were highest but overall TAAA was not significantly different among imported corns. True availability of NFE of USA, ARG and CHN was significantly(P<0.05) higher than that of CHNP. However, true availability of crude protein, crude fat, crude fiber and crude ash were not significantly different among corns. The correlation coefficient between TME and MEn value was 0.91 which was significant at P<0.1 but correlation coefficient between TME and ME value and between TME and MEpc value was 0.90 and 0.83, respectively which was not significant at P<0.1. In conclusion, US corn was highest in TME values and Chinese premium corn was not significantly different from regular Chinese corn. The MEn value obtained by equation based on chemical analysis may be used as a tool to evaluate TME value of corn.

Evaluation of Dose and Position Compensation of Parotid Gland Using CT On-rail System in Head-and-Neck Cancer (두경부 암환자 치료 시 CT On-rail System을 이용한 이하선의 위치 보정 및 선량 평가)

  • Jang, Hyeong-Jun;Im, Chung-Geun;Chun, Geum-Sung;Jeong, Il-Seon;Kim, Hoi-Nam
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.83-89
    • /
    • 2008
  • Purpose: The checking method of target and normal structure are used by MVCBCT, KVCBCT, CT On-rail System, Ultrasound in H&N cancer patient. In case of MVCT, the utilization of bone structure is valuable to check around tissue. But the utilization of soft tissue is not enough. The point of this paper is dose variation in movable parotid and changeable volume of H&N cancer patient of CT On-rail System. Materials and Methods: The object of H&N cancer patient is 5 in this hospital. The selected patient are scanned ARTISTE CT Vision (CT On-ral System) a triweekly. After CT scanning, tranfered coordinates are obtained by movable of parotid gland comparison with planning image. Checking for the changeable volume of parotid gland. A Obtained CT image are tranfered to the RTP System. So dose variation are checked by following changed volume. Results: The changes of target coordinate by the parotid gland movement are X: -0.4~0.4 cm, Y: -0.4~0.3 cm, Z: -0.3~0.3 cm. the volume of GTV is decreased to about 7.11%/week and then both parotid gland volume are shrinked about 4.81%/week (Lt), 2.91%/week (Rt). At the same time, each parotid gland are diminished in radiation dose as 3.66%/week (Lt), 2.01%/week. Conclusion: Images from CT on the rail System which are able to aquire the better quality images of soft tissue in Target area than MVCBCT. After replanning and dose redistribution by required images, It could gain not only the correction of the patient set-tup errors but exact dose distribution. Accordingly, the delivery of compensated dose, It makes that we could do Adaptive Targeting Radiotherapy and need Real Time Adaptive Targeting Radiotherapy by reduce beam delivary time.

  • PDF

A Pilot Study for the Remote Monitoring of IMRT Using a Head and Neck Phantom (원격 품질 보증 시스템을 사용한 세기변조 방사선치료의 예비 모니터링 결과)

  • Han, Young-Yih;Shin, Eun-Hyuk;Lim, Chun-Il;Kang, Se-Kwon;Park, Sung-Ho;Lah, Jeong-Eun;Suh, Tae-Suk;Yoon, Myong-Geun;Lee, Se-Byeong;Ju, Sang-Gyu;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.25 no.4
    • /
    • pp.249-260
    • /
    • 2007
  • Purpose: In order to enhance the quality of IMRT as employed in Korea, we developed a remote monitoring system. The feasibility of the system was evaluated by conducting a pilot study. Materials and Methods: The remote monitoring system consisted of a head and neck phantom and a user manual. The phantom contains a target and three OARs (organs at risk) that can be detected on CT images. TLD capsules were inserted at the center of the target and at the OARs. Two film slits for GafchromicEBT film were located on the axial and saggital planes. The user manual contained an IMRT planning guide and instructions for IMRT planning and the delivery process. After the manual and phantom were sent to four institutions, IMRT was planed and delivered. Predicted doses were compared with measured doses. Dose distribution along the two straight lines that intersected at the center of the axial film was measured and compared with the profiles predicted by the plan. Results: The measurements at the target agreed with the predicted dose within a 3% deviation. Doses at the OARs that represented the thyroid glands showed larger deviations (minimum 3.3% and maximum 19.8%). The deviation at OARs that represented the spiral cord was $0.7{\sim}1.4%$. The percentage of dose distributions that showed more than a 5% of deviation on the lines was $7{\sim}27%$ and $7{\sim}14%$ along the horizontal and vertical lines, respectively. Conculsion: Remote monitoring of IMRT using the developed system was feasible. With remote monitoring, the deviation at the target is expected to be small while the deviation at the OARs can be very large. Therefore, a method that is able to investigate the cause of a large deviation needs to be developed. In addition, a more clinically relevant measure for the two-dimensional dose comparison and pass/fail criteria need to be further developed.

Clinical Study on Hemolytic Uremic Syndrome in Children: Review of 23 Cases (소아 용혈성 요독 증후군 23예에 대한 임상적 고찰)

  • Oh Seungjin;Yook Jinwon;Kim Ji Hong;Kim Pyung-Kil
    • Childhood Kidney Diseases
    • /
    • v.4 no.2
    • /
    • pp.136-143
    • /
    • 2000
  • Purpose : The hemolytic uremic syndrome (HUS) is characterized by microangiopathic hemolytic anemia thrombocytopenia, and acute renal failure. It is ole of tile most common cause of acute renal failure in children but few reports are available in Korea. Thus we investigated the 23 patients diagnosed as HUS during last 14 years. Method : We retrospectively investigated the etiologic factor, clinical manifestations laboratory findings, treatment modalities, and final outcomes of the patients. Then patients were divided into two groups according to outcome, md comparison was performed. Group A(8) comprised patients who progressed to end-stage renal disease or expired. Group B(15) comprised patients who completely recovered after dialysis treatment. Result The number of patients aged less than 4 years were 17; between 5 and 10 were 4 and more than 10 were 2. The gende ratio was M:F=2 : 1. The etiologic factors were as follows: acute gastroenteritis in 14 patients including 4 bloody diarrhea, upper respiratory tract infection in 7 patients, and 1 patient with herbal mediation. The overall mortality rate was 22$\%$: 2 patients died of US complications, 2 patients died of sepsis, and 1 patient died of pulmonary hemorrhage. Group A (Hb 4.8${\pm}$1.2 g/dL) showed lower value in hemoglobin than group B (Hb 6.3${\pm}$1.7 g/dL) during hospital stay (P< 0.05), And the time interval between tile disease onset and dialysis treatment was significantly longer in group A ($11.9{\pm}9.1\;days\;vs\;2.8{\pm}2.1\;days$) (P< 0.05). Conclusion : Overall mortality rate was 22$\%$. Low hemoglobin value and the prolonged time interval between the disease onset and dialysis treatment were related with poor prognosis. So early diagnosis and appropriate intensive care including dialysis treatment is essential to achieve better outcome in children.

  • PDF

Effect of Omentum, Pleura, Diaphragm on Tracheal Autograft Survival (자가이식기관의 생존에 필요한 장막, 흉막, 횡격막의 역할 분석)

  • Keum, Dong-Yoon
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.461-467
    • /
    • 2005
  • Pleura, diaphragm, pericardial fat pad, intercostal muscles and omentum can be used to protect and revascularize the bronchial suture line of tracheal transplantation, lung transplantation and pulmonary resection. The purpose of the present study is to compare the influence of the pleura, diaphragm and omentum in survival of isolated tracheal segments in the experimental animals. Material and Method: Sprague-Dawley rats weighing 250- 350g were used. The animals were divided in three groups; the pleura, omentum and diaphragm. Following intraperitoneal anesthesia, endotracheal intubation was performed. Then the trachea was exposed. A three-ring sec- tion of cervical trachea was excised. The resected trachea was implanted at each sites. After 2 weeks, rats were sacrificed. Histopathological examination of the tracheal segments was performed. For comparison of each groups, histopathological viability of resected tracheal segment was scored by three tissue layers; epithelium, submucosa, and cartilage. The results were presented as average score. Result: In histopathological examination, submucosa and cartilage using tracheal segment necrosis scoring system. The pleural group showed well preserved tissue. There was minimal necrosis and inflammation compared with other groups. In the pleural group, tracheal necrosis scores were $2.17\pm0.983$at epithelium, $1.67\pm0.516$ at submucosa and $2.17\pm0.753$ at cartilage. At the omental group, scores were $1.00\pm0.00,\;1.60\pm0.548\;and\;1.80\m0.447$. In the diaphragmatic group, scores were $1.40:\pm0.894,\;2.40\pm0.547\;and\;2.20\pm0.447$. Total necrosis score were $6.00\pm1.789$ in the pleural group, $4.40\pm0.894$ in the omental group and $6.00\pm1.414$ in the diaphragmatic group. Conclusion: There were no significant viability differences in terms of total necrosis score for the viability of resected tracheal segment. But the best result was achieved in the omental group. Therefore, omental wrapping on tracheal graft site will be beneficial for the prevention of graft necrosis.

Studies on canine babesiosis in Korea I. In vitro isolation and antigenic properties of Babesia gibsoni (개 바베시아병에 관한 연구 I. Babesia gibsoni의 시험관내 분리와 항원성상에 관한 연구)

  • Lee, Ho-kweon;Suh, Myung-deuk
    • Korean Journal of Veterinary Research
    • /
    • v.36 no.3
    • /
    • pp.681-692
    • /
    • 1996
  • The present study was conducted to isolate Babesia gibsoni by culture method of the microaerophilous stationary phase(MASP) and analyse the antigenic properties of the parasite by SDS-PAGE and immunoblot. The results obtained were summarized as follows. The protozoan parasite Babesia gibsoni multiplied in canine erythrocytes in RPMI 1640 medium(pH7.0) containing 20 40% normal canine serum under the MASP condition of 5% CO2 and 95% air at $37^{\circ}C$ incubator. The levels of parasitaemia in the erythrocytes were shown more higher by exchanging the medium at 24 hours interval. Under the above condition of MASP, the percentage of parasitized erythrocytes(PPE) after incubation for 8 days increased about 14 times more than that in the initiation of the 1% infected canine erythrocyte culture. The parasites were purely isolated from the MASP culture of red blood cells collected from dogs infected with Babesia gibsoni naturally or artificially. Among the total of 36 canine(Pit-bullterier) blood samples the parasites were isolated from 17 cases(47.2%) in the MASP culture while the parasites were detected from 20 cases(56%) and 12 cases(33.3%), respectively, by indirect fluorescent antibody(IFA) test and direct light microscopy(DLM). On the other hand, Babesia gibsoni was isolated by MASP culture from 15 cases(75%) and 11 cases(92%) of positive cases of IFA and DLM, respectively. In the analysis of the erythrocytic merozoite(AEOM) antigen derived from infected dog approximately 11 antigenic bands in molecular weight of 130, 120, 97.4, 92, 80, 52, 50, 42, 36, 30 and 29 KDa were observed on SDS-PAGE. Antigenic bands in the endoerythrocytic merozoite(CEOM) antigen derived from infected erythrocyte (sediment) in MASP culture were much similar to those of AEOM bands. In the exoerythrocytic merozoite(CEEM) antigen derived from supernatant of the infected erythrocyte culture approximately 20 antigenic bands were observed and the molecular weight of the major bands among these were 140, 120, 114, 105, 96, 93, 92, 80, 60, 52, 50, 38, 36, 30, 24, 18.5 and 16 KDa. In the protein patterns of AEOM and CEOM antigen by immunoblot 15 bands were observed and these patterns were much similar between each other. The molecular weight of the major bands in the both antigens were 130, 120, 80, 60, 52, 50, 42, 30, 29, 18.5 and 16 KDa. Approximately 21 bands were observed in CEEM antigen and the molecular weight of the major bands were 140, 120, 96, 92, 85, 80, 76, 60, 52, 50, 37, 30, 24, 16 and 15 KDa. The specific antigenic bands in the artificially infected dogs were firstly observed at 3 weeks afrer inoculation of infected blood and these antigenic bands were maintained up to 18 months after inoculation. In the immunoblot of the sera of the splenectomized dogs the specific antigenic bands with the molecular weight of 93 KDa and 52 KDa, respectively, were observed weakly comparing to those of non-splenectomized dog. In immunoblot of the sera collected from the naturally infected dogs the antigenic bands were observed as same as those of artificially infected dogs while antigenic band of 29 KDa in some individual dog showed strongly. In comparison of immunoblot of the sera collected from dogs non-treated and treated with diminazene aceturate(7mg/kg, IM) after artificial infection no differences of antigenic bands were observed. In analysis of antigenic bands by digoxigenin glycan/protein double labeling, antigenic bands in the molecular weight of 106, 60 58, 36, 30 and 29 KDa were determined as glycoproteins.

  • PDF