• Title/Summary/Keyword: Metering rate

Search Result 91, Processing Time 0.025 seconds

Evaluation of Metering Accuracy of Hydrogen Station Using Master Meter Method (표준유량계법을 적용한 수소 충전소 계량 정확도 평가)

  • Han, Wonguk;Yim, Sangsik;Song, Bohee;Kil, Sunghee;Kim, Younggyu;Kim, Hongchul
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.67-73
    • /
    • 2019
  • Hydrogen is difficult to accurately measure the amount of charge due to sudden temperature changes and pressure rise when charging the vehicle. In order to construct a hydrogen infrastructure, it is important to precisely measure the amount of charge that can be a sensitive issue in commercial transactions. In this study, the accuracy of metering of domestic hydrogen stations was evaluated as a study for metering management of hydrogen dispenser. For the experiment, we constructed metering system using master meter method and measured the flow rate in the actual hydrogen vehicle charging environment. As a result of error occurred about 10% on average, and the hydrogen loss per one charge was found to be up to 60g.

A study on Development of a Pneumatic Granular Applicator for Paddy Field (I) - Granular Discharge Rate, Diffuser and Optimal Application Conditions - (수도작용 송풍식 입제살포기 재발에 관한 연구 (I) - 입제 배출량, 분두 및 적정살포조건 -)

  • 정창주;정선옥;장영창;최영수;최중섭
    • Journal of Biosystems Engineering
    • /
    • v.22 no.2
    • /
    • pp.127-136
    • /
    • 1997
  • This study was accomplished to develop a pneumatic granular applicator that can be attached to the conventional ride-on rice transplanter. Operating conditions of a metering device for the applicator were determined so as to obtain the required discharge rate of granules for field application. The shape and size of diffuser was selected for the applicator and the spacing between diffusers on a boom and the boom height were determined as an optimal application condition for uniform distribution. The diffuser spacing of 1m for the fertilizer and the diffuser spacing of 0.8m for the pesticide at the boom height over 0.8m were acceptable.

  • PDF

Design of Single Rate Three Color Marker using FPGA (EPGA를 이용한 Single Rate Three Color Marker 설계)

  • Park, Chung-Kwan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.12
    • /
    • pp.141-148
    • /
    • 2005
  • This paper addresses the design of srTCM (single rate Three Color Marker) described in RFC2697. It has proposed for srTCM to be used at the ingress of Differentiated Service network that provides AF PHB (Assured Forwarding Per Hop Behavior). srTCM is the marker with the metering function, and consists of the token updating function and the marking function. The token updating function uses the dual token bucket. The marking function compares the token values with the length of input packet, and then marks the result into IP QoS field (ToS field). This paper designs srTCM function and then implements it in one chip using VHDL and FPGA technology.

Development of Automatic Nutrient-Solution Mixing System Using a Low-Cost and Precise Liquid Metering Device (액제 정밀계량 장치를 이용한 양액 자동조제 시스템 개발)

  • 이규철;류관희;이정훈;김기영;황호준
    • Journal of Biosystems Engineering
    • /
    • v.22 no.4
    • /
    • pp.469-478
    • /
    • 1997
  • This study was conducted to develop an automatic nutrient-solution mixing system for small-scale sewers. The nutrient-solution mixing system consisted of a low-cost and precise metering device and data acquisition & control system with a personal computer. and, the metering device was composed of three parts those were supply pumps, metering cylinders and venturi tube. The system controlled electric conductivity(EC) and pH of nutrient-solution based on the time-based feedback control method with the information about temperature, EC, and pH of the nutrient-solution. The performance of the nutrient-solution mixing system was evaluated through the control of EC and pH while compared with those of commercial system. Also an experimental cultivation of tomato was conducted to verify and to improve the developed system. Results of this study were as follows. 1. The correlation coefficient of meteing device between the flow rate and operating time was 0.9999, and the linear reuession equation computed was y=21.759x, where y is the discharge($g$) and x is the operating time(s). 2. Calculated errors for the developed metering device and two commercial pump were $\pm$0.3% $\pm$2.45% and $\pm$1.38 % FS error respectively. 3. An automatic nutrient-solution mixing system based on a low-cost and precise metering device was developed. 4. The full scale errors of the developed system in controlling EC and pH at 23$\pm$1$^{\circ}C$ were $\pm$0.05mS/cm and $\pm$0.2, respectively 5. When using the commercial system, the controlled values of EC and pH of the 500 $\ell$ of water were 1.29 mS/cm and 6.1 pH for the setting points of 1.4 mS/cm and 6.0 pH respectively at 23$pm1^{\circ}C$. 6. The developed nutrient-solution control system showed $\pm$0.05 ms/cm of deviation from the setting EC value over the experimental cultivation period. 7. The deviation from the average values of Ca and Mg mass content in the several nutrient-solution were 0.5% and 1.8% respectively.

  • PDF

470-MHz-698-MHz IEEE 802.15.4m Compliant RF CMOS Transceiver

  • Seo, Youngho;Lee, Seungsik;Kim, Changwan
    • ETRI Journal
    • /
    • v.40 no.2
    • /
    • pp.167-179
    • /
    • 2018
  • This paper proposes an IEEE 802.15.4m compliant TV white-space orthogonal frequency-division multiplexing (TVWS)-(OFDM) radio frequency (RF) transceiver that can be adopted in advanced metering infrastructures, universal remote controllers, smart factories, consumer electronics, and other areas. The proposed TVWS-OFDM RF transceiver consists of a receiver, a transmitter, a 25% duty-cycle local oscillator generator, and a delta-sigma fractional-N phase-locked loop. In the TV band from 470 MHz to 698 MHz, the highly linear RF transmitter protects the occupied TV signals, and the high-Q filtering RF receiver is tolerable to in-band interferers as strong as -20 dBm at a 3-MHz offset. The proposed TVWS-OFDM RF transceiver is fabricated using a $0.13-{\mu}m$ CMOS process, and consumes 47 mA in the Tx mode and 35 mA in the Rx mode. The fabricated chip shows a Tx average power of 0 dBm with an error-vector-magnitude of < 3%, and a sensitivity level of -103 dBm with a packet-error-rate of < 3%. Using the implemented TVWS-OFDM modules, a public demonstration of electricity metering was successfully carried out.

A Mainline Metering Strategy at Toll Plaza Considering Queue Imbalance Among Lanes (차로간 Queue 불균형을 고려한 Toll Plaza 본선미터링 전략)

  • Jang, Sunghoon;Lee, Yong-Gwan;Kho, Seung-Young;Lee, Chungwon
    • Journal of Korean Society of Transportation
    • /
    • v.33 no.1
    • /
    • pp.1-13
    • /
    • 2015
  • This study aims to develop a mainline metering strategy considering queue imbalance among lanes that can reduce congestion at a toll plaza section by managing queue caused by mainline metering. The suggested strategy considers simultaneously optimizing the number of cars in merging area and managing queue by lane. This study analyzes the effectiveness of the strategy with respect to the average travel time and the occurrence rate of spillback using the PARAMICS. The results show that the suggested strategy has an effect on reducing congestion and improving operation efficiency at toll plaza. In particular, the congestion become more intensified when the length of waiting space is shorter; however, this study shows that the suggested strategy can relieve the congestion in that condition.

Research Regard to Necessity of Smart Water Management Based on IoT Technology (IoT 기술을 활용한 스마트 물관리 필요성에 관한 연구)

  • Choi, Young Hwan;Kim, Yeong Real
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.22 no.4
    • /
    • pp.11-18
    • /
    • 2017
  • The Objective of this Study is to Prove the Effectiveness of a Smart Water Management(SWM) Technology. The SWM Technology can Reduce the Production Cost using Internet of Thing(IoT) Technology that Utilizes Remote Metering of Consumer's Water usage and Reduce the Leakage of Supply Facilities. The SWM Demonstration Model Installed a Remote Water Leakage Sensor, Smart Metering and Micro Multi Sensor in Water Supply Facility, and Provided Real-Time Monitoring of the Operation Status. Consumers can be Provided the usage of Tap Water and the Water Puality through a Smart Phone Application. At this Time, we Surveyed Whether Consumers save the Tap Water or Drinking Directly using the Tap Water usage Information. Also, this Study is to Verify the Degree of Improvement of Water Supply Rates and Drinking Water Rate, and to Decrease Consumer's Complaints, Operating Costs, and Water Consumption by the SWM Technology. It is also Established a SWM Model Combined with the IoT Sensor at Supply Facilities, operator monitoring system and explored recovery solution detected events. It means the upbringing of the domestic water industry by developing the related technologies and spreading the SWM to advanced levels.

Development and Performance Test of DC Smart Metering System for the DC Power Measurement of Urban Railway (도시철도 직류 전력량 계측을 위한 직류용 스마트미터링 시스템 개발 및 성능시험)

  • Jung, Hosung;Shin, Seongkuen;Kim, Hyungchul;Park, Jongyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.5
    • /
    • pp.713-718
    • /
    • 2014
  • DC urban railway power system consists of DC power network and AC power network. The DC power network supplies electric power to railway vehicles and the AC power network supplies electric power to station electric equipment. Recently, because of power consumption reduction and peak load shaving, intelligent measurement of regenerative energy and renewable energy adapted on DC urban railway is required. For this reason, DC smart metering system for DC power network shall be developed. Therefore, in this paper, DC voltage sensor, current sensor, and DC smart meter were developed and evaluated by performance test. DC voltage sensor was developed for measuring standard voltage range of DC urban railway, and DC current sensor was developed as hall effect split core type in order to install in existing system. DC smart meter possesses function of general intelligent electric power meter, such as measuring electricity and wireless communication etc. And, DC voltage sensor showed average 0.17% of measuring error for 2,000V/50mA, and current sensor showed average 0.21% of measuring error for ${\pm}2,000V/{\pm}4V$ in performance test. Also DC smart meter showed maximum 0.92% of measuring error for output of voltage sensor and current sensor. In similar environment for real DC power network, measuring error rate was under 0.5%. In conclusion, accuracy of DC smart metering system was confirmed by performance test, and more detailed performance will be verified by further real operation DC urban railway line test.

Development of two-component polyurethane metering system for in-mold coating (인몰드 코팅을 위한 2액형 폴리우레탄 공급장치 개발)

  • Seo, Bong-Hyun;Lee, Ho-Sang
    • Design & Manufacturing
    • /
    • v.10 no.2
    • /
    • pp.18-23
    • /
    • 2016
  • Injection molded thermoplastic parts may need to be coated to facilitate paint adhesion, or to satisfy other surface property requirements, such as appearance, durability, and weather resistance. In this paper, a two-component polyurethane metering system was developed for the simultaneous injection and surface coating of a plastic substrate. The system was composed of storage tanks, feed pumps, axial piston pumps, mixing head. The tank was designed to be double-jacket structured and fabricated for polyol and isocyanate, respectively. A temperature chamber was used to maintain the material temperature to be $80^{\circ}C$ during flowing from storage tank to mixing head. Inside the chamber, feed pump, low pressure filter, high pressure pump, high pressure filter, pressure sensor, flow meter were installed. A mixing head of L-type was used for homogeneous mixing of polyol and isocyanate. Inside the mixing head, a cartridge heater and a temperature sensor were installed to control the temperature of the materials. The flow rate of axial-piston pump was controlled by using closed-loop feedback control algorithm. The input flow-rates were compared with the measured values. The output error was 6.7% for open-loop control, whereas the error was below 2.2% for closed-loop control. In addition, the pressure generated through mixing-head nozzle increased with increasing flow rate. It was found that the pressure drop between metering pump and mixing-head nozzle was almost 10 bar.

Improvement of ALINEA Model Using Speed (속도를 이용한 ALINEA 모델 보완에 관한 연구)

  • Cho, Han-Seon;Lee, Jun;Lee, Ho-Won;Kim, Eun-Mi
    • Journal of Korean Society of Transportation
    • /
    • v.26 no.5
    • /
    • pp.73-80
    • /
    • 2008
  • ALINEA algorithm, which is one of the best on-ramp metering algorithms, was designed to control the traffic volume from on-ramp in order to maintain the optimal occupancy rate of the detectors installed downstream of the merge area. But, the reliability of occupancy rate estimated from the loop detectors, which are used most commonly in Korea, is relatively lower than other parameters such as speed and volume. Moreover, because occupancy rate depends on the length of loop detectors and site, lots of calibration work is required whenever they are installed in order to estimate the occupancy rate. Therefore, there exists room for improvement of ALINEA algorithm because only occupancy rate having some problems is considered as a control parameter in ALINEA algorithm. Practically it is difficult to measure or perceive the occupancy rate for traffic engineers and drivers. On the other hand, speed can be good alternative which can overcome the defect induced by using occupancy. In this study, occupancy based ALINEA algorithm is converted to speed based ALINEA assuming the linear relationship between density and speed.