• Title/Summary/Keyword: Metering System

Search Result 272, Processing Time 0.037 seconds

A Study of an Application Scheme for Smart Meter and Value Added Services Based on Korean Environment (한국형 스마트 전력량계 부가서비스 적용방안 연구)

  • Kim, Seok-Gon;Lee, Han-Byul;Lee, Young-Joo;Choi, Yong-Sung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.106-111
    • /
    • 2010
  • Electronic watt hour meters(WHM) for high pressure running in domestic were installed to the digital type meter and ones for low pressure are expected to complete within several years. Domestic power metering technology is being beyond a simple framework with an electronic type and is rapidly evolving to intelligent smart metering systems in conjunction with promotion of a national smart grid project. Major policy outlook of the world's major power company regarding Intelligent metering is the application of the fare structure diversification and is the improvement of level of service to customers. In addition, electric power companies should focus on the cost reduction and the improvement of management efficiency through an efficient operation of distribution facility. In this paper, we are about to make an observation of the additional services technology development trend of the overseas smart meter and to have a view of value-added services(VAS) system of smart meter suitable for the domestic environment based on the technology development of VAS utilizing electronic watt hour meter performed by recent research projects.

Power Quality Monitoring with Electronic Watt-hour meter and Wireless communication module (전자식 전력량계와 무선모듈을 이용한 전력품질 표시 및 모니터링)

  • Jung, Deug-Il;Son, Young-Dae
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.172-174
    • /
    • 2007
  • An electronic watt-hour meter with high-precision measurement technology can provide many valuable metering data of a real-time system measurements, such as per-phase voltage, ampere, active power, reactive power, apparent power, power factor, and system frequency. Also many of accumulated metering data such as active energy, reactive energy, apparent energy, and load profile can be gettable from an electronic watt-hour meter[1]. This paper presents an approach of the small-sized AMR (Automatic Meter Reading) that provides customers with a very valuable electrical service. This AMR service transmits lots of a valuable metering data by using ZigBee communication module, so that users resided in their premises can use the information to audit a power quality and improve their electrical conditions by using the PQ monitoring device equipped with ZigBee receiver. This PQ monitoring device shows metering data on LCD and transmits to the PC through an internal network. Also, the device can keep the valuable meter data into a built-in non-volatile memory. The final goal of this paper is to better understand the power quality of electrical systems and offer the power qualify information for the convenience of all power consumers.

  • PDF

A Study on the Design and Modeling of PWM Fuel Metering Unit for Miniature Turbo Engines (초소형 터보엔진용 PWM 연료조절장치의 설계 및 모델링에 관한 연구)

  • Joo Sang-Hyun;Choi Ho-Jin;Park Jong-Seung;Lim Jin-Shik
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.2
    • /
    • pp.95-101
    • /
    • 2006
  • A fuel metering unit using PWM(Pulse Width Modulated) solenoid valve has some advantages such as low cost, small size and simple structure. The mathematical model and its experimental rig of the fuel metering unit using PWM solenoid valve and CPDV(Constant Pressure Drop Valve) for miniature turbo engines were constructed. As the results of simulation, some major parameters which have dominant effects on the performance were found. And the experimental results verified the validity of established model by showing the good agreement with the numerical simulation results. Hence, this system modeling could be used effectively in the actual development of a PWM fuel control system.

Fluid Network Analysis for the Fuel-Supply Systems of Gaseous-Injection-Type LPG Engines (가스분사 방식 LPG 엔진의 연료공급시스템 관로 유동해석)

  • Yun, Jeong-Eui
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.10
    • /
    • pp.1019-1024
    • /
    • 2011
  • The gaseous fuel injection(GFI) type of LPG fuel-supply system is more advantageous than liquefied fuel injection(LFI) from the viewpoint of durability and cost reduction. However, compared with LFI types of LPG fuel-supply systems, in the GFI systems it is difficult to achieve precision fuel metering because of the compressible characteristic of the gaseous fuel. In this study, a Helmholtz resonator is proposed as an appropriate system for precision fuel metering in GFI systems, and the effects of the Helmholtz resonator on the fuel metering are simulated by the commercial flow-network-analysis package Flowmaster.

SDRE Based Optimal Nonlinear Observer-Controller Design for Ramp Metering System (진입로 신호등 시스템을 위한 SDRE 기반 최적 비선형 관측기 제어기 설계)

  • Lee, Kiho;Choi, Han Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.5
    • /
    • pp.533-536
    • /
    • 2014
  • In this paper, a near optimal decentralized observer-controller design method is proposed for ramp metering systems based on SDRE (State Dependent Riccati Equation) approach. The optimal nonlinear observer gain is parameterized in terms of the solution matrix of an SDRE. This paper gives a simple algorithm to compute the near optimal observer gain. The optimal control design problem is also considered. Finally, numerical simulation results are given to illuminate the effectiveness and practicality of the proposed design method.

Development and Performance Test of DC Smart Metering System for the DC Power Measurement of Urban Railway (도시철도 직류 전력량 계측을 위한 직류용 스마트미터링 시스템 개발 및 성능시험)

  • Jung, Hosung;Shin, Seongkuen;Kim, Hyungchul;Park, Jongyoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.5
    • /
    • pp.713-718
    • /
    • 2014
  • DC urban railway power system consists of DC power network and AC power network. The DC power network supplies electric power to railway vehicles and the AC power network supplies electric power to station electric equipment. Recently, because of power consumption reduction and peak load shaving, intelligent measurement of regenerative energy and renewable energy adapted on DC urban railway is required. For this reason, DC smart metering system for DC power network shall be developed. Therefore, in this paper, DC voltage sensor, current sensor, and DC smart meter were developed and evaluated by performance test. DC voltage sensor was developed for measuring standard voltage range of DC urban railway, and DC current sensor was developed as hall effect split core type in order to install in existing system. DC smart meter possesses function of general intelligent electric power meter, such as measuring electricity and wireless communication etc. And, DC voltage sensor showed average 0.17% of measuring error for 2,000V/50mA, and current sensor showed average 0.21% of measuring error for ${\pm}2,000V/{\pm}4V$ in performance test. Also DC smart meter showed maximum 0.92% of measuring error for output of voltage sensor and current sensor. In similar environment for real DC power network, measuring error rate was under 0.5%. In conclusion, accuracy of DC smart metering system was confirmed by performance test, and more detailed performance will be verified by further real operation DC urban railway line test.

A demonstration case study on the multiple-customer smartgrid power metering system (다수용가 스마트그리드 전력계량시스템에 대한 실증사례 연구)

  • Lee, Il-Ho;Song, Kwang-Jae;Song, Sang-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.26-27
    • /
    • 2015
  • 본 연구에서는 다수용가형 집합건물, 공장형 아파트 및 빌딩에 적합한 다채널 전력계량시스템(MCMS:Multi Customer Metering System)의 성능평가방법 및 현장실증의 결과를 제시하고, 핵심 요소인 mA CT의 성능평가방법 및 표준현황 연구를 통해 향후 MCMS 국내 도입을 위한 시험인프라 구축 및 관련 제품의 적합성을 제시하고자 한다.

  • PDF

A Economic Evaluation for Demand-Side Resource using Smart Metering System (스마트계량시스템을 활용한 수요관리자원에 대한 가치평가연구)

  • Lim, Sang-Kug;Shin, Hee-Sang;Cho, Sung-Min;Lee, Hee-Tae;Yoon, Yong-Tae;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.2
    • /
    • pp.44-50
    • /
    • 2010
  • Recently, the crude oil price per one barrel in 2005 cost 49.4 dollars. But the value of crude oil in 2007 had ascended 68.4 dollars which was skyrocketed 38.5[%] owing to the sudden rise of energy price. As it has been growing the necessity of energy efficiency, energy intentive companies actively try to implement energy management system It has been studied to improve the energy saving for household sector using the smart metering system which can give the information of energy prices, pattern on real time to energy consumers and voluntarily lead the activities of energy saving. In this paper, we estimated potential benefits and value of smart metering system through california test.

A case study for installing of Energy Metering Systems in an Office Building (사무소 건물의 에너지 미터링 시스템 구축에 관한 사례연구)

  • Han, Hye-Sim;Lee, Na-Eun;Lee, Jin-Sook;Jeong, Hak-Geun;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.51-57
    • /
    • 2013
  • Energy saving starts by knowing how much energy is being consumed. A building factor is easier than any other things in energy saving. Since, especially, it is closely connected with user's space-use-patterns and manager's utility-operation-style. An energy metering system lets building users know about energy consumption pattern in buildings and measure energy in real time. Development and materialization of metering systems need more careful plans, so that they depend on a demand of individual facilities and available infrastructures they used to use. But, so far, there is no guidelines how to install metering systems. This paper suggested how to install meters and researched a method for how to analyze by using metered data. For that, Green Building in KIER is used as a test bed. As the results, nevertheless the smallest number of meters is basically one for the whole building energy measuring, it is too limited in analysis. So we needed to add the sort of fuel and utility types and found that it depends on all cases. For this reasons, a guideline should be created in order to install meters as soon as possible. It would be suggest a way to save more energy in building factor.

Selection of Expressway Ramp Metering Sites and Priority Making (고속도로 램프미터링 도입지점 및 우선순위 선정)

  • Choi, Keechoo;Shim, Sangwoo;Lee, Eui-Eun;Kim, In-Su
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.5D
    • /
    • pp.579-585
    • /
    • 2009
  • In spite of the proven effectiveness of ramp metering system, it has not been successfully implemented in Korean setting. The purpose of this paper is to select target locations to introduce ramp metering into the Korean expressway system. For this, domestic standards to introduce ramp metering have been presented after reviewing those of the US. The major criteria are level of service (LOS), the existence of detour route, space for queue build-up and opened ramp. 15 different locations were selected and AHP has been used to make priority among them. Intuitively, the result of priority was in accordance with the congestion and traffic volume. The core results identified in this paper is expected to be used in different cities and expressway networks elsewhere.