• Title/Summary/Keyword: Meter-out control

Search Result 81, Processing Time 0.039 seconds

Optimal Amount and Mixture Ratio of Seeding of the Exotic and Native Plants for Slope Revegetation(II) (사면 녹화용 외래초종과 재래 목·초본식물의 적정 파종량 및 혼파비에 관한 연구(II))

  • Jeon, Gi-Seong;Woo, Bo-Myeong
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.2 no.2
    • /
    • pp.43-52
    • /
    • 1999
  • This study was carried out to verify results of the nursery seedbeds. From November of 1997 to September of 1998, the artificial banking slopes in the greenhouse of the College of Agriculture and Life Sciences, Seoul National University were seeded with the mixtures of those species. Most of exotic species showed relatively poor development of root as short as 30cm. Also the green weight of root biomass of the native species was more than two times than that of the exotic species. On the other hand, it was found that the exotic species have relatively well-developed fine roots. Thus, it was concluded that the seed-mixture of the native species with long and thick roots and the exotic species with fine roots be the most effective method for topsoil erosion control on banking-slopes. The artificial rainfall system treatment(30mm/hr, 60mm/hr, 100mm/hr) on $30^{\circ}$ banking-slopes did not cause any significant change in the amount of soil loss by erosion. The root system was best developed in the plot of 1,000 seedlings per square meter and it performed well for soil erosion control. Consequently, in the case of seeding of single herbaceous species without mixing any woody seeds, the expected seedlings were 1,000 to 2,000 per square meter.

  • PDF

A Study on Dynamic Behaviour of the Nonlinear Pneumatic System (비선형 공압시스템 특성해석)

  • Kim, Dong-Su;Kim, Hyeong-Ui
    • 연구논문집
    • /
    • s.27
    • /
    • pp.153-166
    • /
    • 1997
  • In industry pneumatic control system has become a important means to obtain automation because of its simplicity, fast speed and low cost. However Due to of the compressibility of air and damping friction between moving parts, it is difficult to achieve high speed driving, accurate positioning and stopping without overshoot in one pneumatic control system. This paper describes the dynamic behaviors of pneumatic linear actuator. The results will be very useful in the prediction of actuated dynamics and for the manufacturers to improve the techniques in their redesign and get better performance. Also, the experimental data is very important for the dynamic simulation and theoretical analysis.

  • PDF

ANGLES ONLY ORBIT DETERMINATION FROM SINGLE TRACKING STATION

  • Lee Byoung-Sun;Hwang Yoola
    • Bulletin of the Korean Space Science Society
    • /
    • 2004.10b
    • /
    • pp.304-307
    • /
    • 2004
  • Satellite orbit determination using angles only data from single ground station is carried out. The KOMPSAT-1 satellite mono-pulse angle tracking data from 9-meter S-band antenna at KARI site in Daejeon are used for the orbit determination. Various angle tracking arcs from one-day to five-day are processed and the orbit determination results are analyzed. Antenna pointing data are predicted based on the orbit determination results to check the possibility of re-acquisition and tracking of the satellite signal. Normal satellite mission operations including orbit determination, antenna prediction, satellite re-acquisition and automatic tracking from predicted antenna angle pointing data are concluded to be possible when three-day angle tracking data from single tracking station are used for the orbit determination.

  • PDF

Improvement of the Degreasing Performance of Surface Treating Steel Sheet by the Automatic Control of Alkaline Degreasing Process (알칼리탈지공정 자동화관리에 의한 표면처리용 강판의 탈지능 향상)

  • 박노범;박대수;박정렬;유민수
    • Journal of the Korean institute of surface engineering
    • /
    • v.29 no.2
    • /
    • pp.132-139
    • /
    • 1996
  • Experiments on the automatic control of NaOH concentration and on the spraying condition of NaOH solution in the alkaline degreasing process of a continuous hot-dip galvanizing line have been carried out in order to improve degreasing performance of a galvanizing sheet steel using laboratory degreasing and galvanizing simulators. The concentration of NaOH for the good degreasing has been determined to be 6.0% and more and this concentration has been able to be automatically well controlled within $\pm$0.1% by employing a solution electrical conductivity meter under a flow injection analysis condition rather than by employing a sodium ion selective electrode in the degreasing simulator. Frequent blocking of the spraying nozzles of the solution has been reduced considerably by the set-up and periodical operation of an automatic valve system in the nozzle system. By applying this automatic valve system and by automatic controlling the NaOH concentration and other ordinary variables in the degreasing process, the degreasing performance has been increased from the conventional 76% to the new 85%.

  • PDF

Design and Implementation for DC Motor controller Using Embedded Target (Embedded Target을 이용한 DC Motor제어가 설계 및 구현)

  • Shin, Wee-Jae
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.13 no.1
    • /
    • pp.56-62
    • /
    • 2012
  • This paper presents design and implementation of the speed controller for DC motor system using Embeded Target for TI C2000 DSP library in Matlab/Simulink is introduced. Speed controller are easily design and implemented by using the Matlab/Simulink program. Feedback of motor speed is processed through eZdsp F2812 AID converter using encoder and pulse meter as speed sensor. Real-time program of controller is drawn using Simulink and converted program code for speed control of P control, PID control and parameter estimation base adaptive control is downloaded into the TI eZdsp 2812 board. Experiments were carried out to examine validity of speed response for implemented controllers. And even if controlled plant becomes alteration studied controller design and implementation easily method.

Development and Evaluation of a PMV Sensor for the Control of Indoor Thermal Environment (실내 온열환경 제어를 위한 PMV 센서의 개발 및 적용성 평가연구)

  • 윤동원;강효석;안병욱
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.10
    • /
    • pp.870-878
    • /
    • 2003
  • The maintenance of thermal equilibrium between the human body and its environment is one of the primary requirements for health, wellbeing and comfort. For the effective control of indoor thermal environment, thermostat or humidistat is used. But, it is not sufficient to control the indoor thermal environment using only one or two parameters as human response for the indoor comfortable environment. So an environmental thermal index is required for the control of indoor thermal environment effectively. In this study, a PMV sensor has been developed which has integrated from various kinds of individual sensors for temperature, humidity, air velocity, radiant temperature. After applying the PMV and PPD equation, it is possible to monitor the indoor thermal environment with the sensor system, which is adopted to the circuit for optimization according to the human response with the metabolic rate and activities. The measurement was carried out to verify the performance of the integrated sensor system in comparison with existing measurement system, the PMV meter. As a result, the possibility of applying the PMV sensor to control the indoor thermal environment simultaneously was examined.

Nurses' Influenza A (H1N1) Infection Control Performance and Stress at Hub Hospitals in Honam Region (호남지역 거점병원 간호사의 신종인플루엔자 감염관리 수행도와 스트레스)

  • Park, Jin-Hee;Kang, Jeong-Hee;Kim, Hyun-Ju
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.17 no.4
    • /
    • pp.520-530
    • /
    • 2010
  • Purpose: In this study influenza A (H1N1) infection control performance and stress in nurses were surveyed, to identify factors influencing stress for the nurses, and to provide basic materials for promoting infectious disease control by nurses. Method: The participants were 447 nurses who had worked at isolation clinics and/or isolation rooms in hub hospitals in the Honam region during the period of the outbreak of 2009 pandemic influenza A (H1N1) virus. Data were collected in February 2010 using self-report questionnaires. Results: The performance of participants from clinics was high for 'helping patients wearing masks', but low for 'maintaining distance over 1 meter among waiting patients'. The performance of participants from hospital rooms was high for 'putting a surgical mask on a patient going out of the room', but low for 'keeping patients' family out of the room'. The participants' stress was higher in those younger and less experienced nurses, those working at a hospital with 500-999 beds, those working at both isolation clinics and rooms, and those working at a clinic longer. Conclusion: In order to lower nurses' stress from working at isolation clinics/rooms for infectious diseases, we may need to deploy experienced nurses and limit their working days to five or less.

Compensation of Error in Noninvasive Blood Pressure Measurement System Using Optical Sensor (광학 센서를 이용한 비관혈적 혈압 측정의 오차 보정)

  • Ko, J.I.;Jeong, I.C.;Lee, D.H.;Park, S.W.;Hwang, S.O.;Park, S.M.;Kim, G.Y.;Joo, H.S.;Yoon, H.R.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.178-186
    • /
    • 2007
  • This study is attempted to correct an error of electronic blood pressure meter with an optical sensor. In general, for a hospitalized patient, ECG, blood pressure, oxygen saturation, and respiration are basically measured to monitor the patient's condition. Opening of a blood vessel after it is occluded by pressurizing the cuff influences the blood flow of peripheral blood vessels as well as oscillation changes in the cuff. Blood vessels are occluded and peripheral blood flow disappears at cuff pressure above the examinee's blood pressure, while blood vessels are opened and peripheral blood flow appears again at cuff pressure under the examinee's blood pressure. Then Disappear-Appear Point Length(DAPL) of peripheral blood flow can be judged with the signal of peripheral blood flow, thus is available as a factor of error correction for electronic blood pressure meter. Also, systolic or diastolic blood pressure can be corrected with Appear-Point-Pressure(APP) of cuff pressure at a point where blood flow occurs and Appear-Maximum Pressure(AMP) of cuff pressure at the maximum amplitude point of peripheral blood flow after peripheral blood flow appears again. For verification, 27 examinees were selected, and their blood value was obtained through experimental procedure of 4 stages including induction of blood pressure change. The examinees were divided into two groups of experimental group and control group, regression analysis was conducted for experimental group, and correction of a blood pressure error was verified with optical signal by applying the regression equation calculated in experimental group to control group. As an experimental result, mean of the whole measurement errors was 5mmHg or more, which did not meet the standard fur blood pressure meter. As a result of correcting blood pressure measurements with data of DAPL, APP, and AMP as drawn out of PPG signal, systolic blood pressure, mean blood pressure, and diastolic blood pressure were $-0.6{\pm}4.4mmHg,\;-1.0{\pm}3.9mmHg$ and $-1.3{\pm}5.4mmHg$, respectively, indicating that mean of the whole measurement errors was greatly improved, and standard deviation was decreased.

Development of Intelligent Compaction System for Efficient Quality Control (효율적 품질관리를 위한 지능형 다짐 시스템 개발)

  • Lee, Soomin;Park, Sangil;Lee, Riho;Seo, Jongwon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.751-760
    • /
    • 2018
  • Currently, the quality measurement of the work is carried out by the supervisor's visual inspection, as the workers individually judge the number of resolutions, thickness, speed and vibration. After work, we are conducting follow-up work through traditional spot test, which is less representative. Therefore, it is impossible to check the results of the resolution, and there is always the possibility that problems will arise due to poor construction. This study demonstrates the feasibility of using the continuous compaction strength measurement method by comparing the continuous compaction strength measurement method and the conventional compaction strength measurement method after performing the compaction in the actual field scale in various test conditions. The validity is verified by analyzing the Compaction Meter Value of an Intelligent Compaction roller composed of a Global Positioning System and an accelerometer, Based on the proven results, a full range of quality can be confirmed without a single test. The quality confirmation is visualized in the compaction control program developed in this study, This enables the field manager to perform real-time quality monitoring at the same time as compaction.

Characteristic Comparison on Internal Cushion Devices at High-speed Pneumatic Cylinders (고속 공기압 실린더 내장용 쿠션기구의 특성 비교)

  • Kim, Dotae;Zhang, Zhong Jie
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.6
    • /
    • pp.24-30
    • /
    • 2013
  • This paper studies the comparative analysis on two different internal cushion devices (the types of needle and relief valve) used to absorb the energy which is generated when the pneumatic cylinder moves with the load at meter-out speed control system. The effect at varying the piston velocity under same driving condition is mainly investigated. The simulation results on pressure in the cushion chamber and the dynamic behavior of the relief valve type cushion device are compared with the needle valve type. Design and performance are improved with the cushion configuration of better quality at high-speed pneumatic cylinder. Based on the relation between absorbed energy and impact energy at cushion process, cushion performance at pneumatic cylinder is evaluated.