• Title/Summary/Keyword: Metallic stent

Search Result 43, Processing Time 0.026 seconds

Development of $^{166}Ho$-Stent for the Treatment of Esophageal Cancer (식도암 치료용 $^{166}Ho$-Stent 개발)

  • Park, Kyung-Bae;Kim, Young-Mi;Kim, Kyung-Hwa;Shin, Byung-Chul;Park, Woong-Woo;Han, Kwang-Hee;Chung, Young-Ju;Choi, Sang-Mu;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.62-73
    • /
    • 2000
  • Purpose: Esophageal cancer patients have a difficulty in the intake of meals through the blocked esophageal lumen, which is caused by an ingrowth of cancer cells and largely influences on the prognosis. It is reported that esophageal cancer has a very low survival rate due to the lack of nourishment and immunity as the result of this. In this study a new radioactive stent, which prevents tumor ingrowth and restenosis by additional radiation treatment, has been developed. Materials and Methods: Using ${\ulcorner}HANARO{\lrcorner}$ research reactor, the radioactive stent assembly ($^{166}Ho$-SA) was prepared by covering the metallic stent with a radioactive sleeve by means of a post-irradiation and pre-irradiation methods. Results: Scanning electron microscopy and autoradiography exhibited that the distribution of $^{165/166}Ho\;(NO_3)$ compounds in polyurethane matrix was homogeneous. A geometrical model of the esophagus considering its structural properties, was developed for the computer simulation of energy deposition to the esophageal wall. The dose distributions of $^{166}Ho$-stent were calculated by means of the EGS4 code system. The sources are considered to be distributed uniformly on the surface in the form of a cylinder with a diameter of 20 mm and length of 40 mm. As an animal experiment, when radioactive stent developed in this study was inserted into the esophagus of a Mongrel dog, tissue destruction and widening of the esophageal lumen were observed. Conclusion: We have developed a new radioactive stent comprising of a radioactive tubular sleeve covering the metallic stent, which emits homogeneous radiation. If it is inserted into the blocked or narrowed lumen, it can lead to local destruction of the tumor due to irradiation effect with dilatation resulting from self-expansion of the metallic property. Accordingly, it is expected that restenosis esophageal lumen by the continuous ingrowth and infiltration of cancer after insertion of our radioactive stent will be decreased remarkably.

  • PDF

Postoperative Clinical Outcomes of Colonic Stent Placement as Bridge-to-surgery vs. Emergency Surgery in Left-sided Malignant Colonic Obstruction

  • Choe, Eun Ju;Lee, Yong Kang;Jeon, Han Ho;Choi, Jong Won;Park, Byung Kyu;Won, Sun Young;Seo, Jeong Hun;Lee, Chun Kyon;Cho, Yong Suk
    • Journal of Digestive Cancer Reports
    • /
    • v.9 no.2
    • /
    • pp.43-49
    • /
    • 2021
  • Background/Aims: Colonic stenting as a bridge to elective surgery is an alternative for emergency surgery in patients with acute malignant colonic obstruction. However, since its benefits are uncertain, we aimed to establish whether it has better clinical outcomes. Methods: The patients with acute malignant left-sided colon obstruction enrolled from January 2009 to December 2018 in National Health Insurance Service Ilsan Hospital. The patients were enrolled to undergo colonic stenting as a bridge to elective surgery or emergency surgery. The following oncological outcomes were assessed: incidence of complete remission, disease progression, local recurrence, and systemic recurrence. Results: Out of 40 patients, 33 received self-expanding metallic stent (SEMS) as a bridge-to-surgery, and 7 underwent emergency surgery. More stoma was made in case of emergency surgery with statistical significance (p < 0.001). There were no significant differences in complete remission rate in curable left-sided malignant colonic obstruction between SEMS as a bridge-to-surgery and emergency surgery. Complete remission was achieved for 3 patients (42.9%) in the non-stent group and 27 patients (81.8%) in the stent group. There was no statistically significant difference in oncologic outcomes between the two groups (p = 0.069). According to multi-variate analysis, advanced TNM stage, Adjuvant chemotherapy, and SEMS bridge-to-surgery were significantly associated with disease-free survival. Disease-free survival rate differed significantly between the two groups (p = 0.024). Conclusions: SEMS as a bridge-to-surgery might be an effective strategy and reduce stoma formation in acute malignant left-sided colon obstruction.

Evaluation of the mechanical properties of current biliary selfexpandable metallic stents: axial and radial force, and axial force zero border

  • Wataru Yamagata;Toshio Fujisawa;Takashi Sasaki;Rei Ishibashi;Tomotaka Saito;Shuntaro Yoshida;Shizuka No;Kouta Inoue;Yousuke Nakai;Naoki Sasahira;Hiroyuki Isayama
    • Clinical Endoscopy
    • /
    • v.56 no.5
    • /
    • pp.633-649
    • /
    • 2023
  • Background/Aims: Mechanical properties (MPs) and axial and radial force (AF and RF) may influence the efficacy and complications of self-expandable metallic stent (SEMS) placement. We measured the MPs of various SEMSs and examined their influence on the SEMS clinical ability. Methods: We evaluated the MPs of 29 types of 10-mm SEMSs. RF was measured using a conventional measurement device. AF was measured using the conventional and new methods, and the correlation between the methods was evaluated. Results: A high correlation in AFs was observed, as measured by the new and conventional manual methods. AF and RF scatterplots divided the SEMSs into three subgroups according to structure: hook-and-cross-type (low AF and RF), cross-type (high AF and low RF), and laser-cut-type (intermediate AF and high RF). The hook-and-cross-type had the largest axial force zero border (>20°), followed by the laser-cut and cross types. Conclusions: MPs were related to stent structure. Hook-and-cross-type SEMSs had a low AF and high axial force zero border and were considered safest because they caused minimal stress on the biliary wall. However, the increase in RF must be overcome.

Prospective Multicenter Study of the Challenges Inherent in Using Large Cell-Type Stents for Bilateral Stent-in-Stent Placement in Patients with Inoperable Malignant Hilar Biliary Obstruction

  • Yang, Min Jae;Kim, Jin Hong;Hwang, Jae Chul;Yoo, Byung Moo;Lee, Sang Hyub;Ryu, Ji Kon;Kim, Yong-Tae;Woo, Sang Myung;Lee, Woo Jin;Jeong, Seok;Lee, Don Haeng
    • Gut and Liver
    • /
    • v.12 no.6
    • /
    • pp.722-727
    • /
    • 2018
  • Background/Aims: Although endoscopic bilateral stent-instent placement is challenging, many recent studies have reported promising outcomes regarding technical success and endoscopic re-intervention. This study aimed to evaluate the technical accessibility of stent-in-stent placement using large cell-type stents in patients with inoperable malignant hilar biliary obstruction. Methods: Forty-three patients with inoperable malignant hilar biliary obstruction from four academic centers were prospectively enrolled from March 2013 to June 2015. Results: Bilateral stent-in-stent placement using two large cell-type stents was successfully performed in 88.4% of the patients (38/43). In four of the five cases with technical failure, the delivery sheath of the second stent became caught in the hook-cross-type vertex of the large cell of the first stent, and subsequent attempts to pass a guidewire and stent assembly through the mesh failed. Functional success was achieved in all cases of technical success. Stent occlusion occurred in 63.2% of the patients (24/38), with a median patient survival of 300 days. The median stent patency was 198 days. The stent patency rate was 82.9%, 63.1%, and 32.1% at 3, 6, and 12 months postoperatively, respectively. Endoscopic re-intervention was performed in 14 patients, whereas 10 underwent percutaneous drainage. Conclusions: Large cell-type stents for endoscopic bilateral stent-in-stent placement had acceptable functional success and stent patency when technically successful. However, the technical difficulty associated with the entanglement of the second stent delivery sheath in the hook-cross-type vertex of the first stent may preclude large cell-type stents from being considered as a dedicated standard tool for stent-in-stent placement.

Endovascular Repair in Acute Complicated Type B Aortic Dissection: 3-Year Results from the Valiant US Investigational Device Exemption Study

  • Lim, Chang Young
    • Journal of Chest Surgery
    • /
    • v.50 no.3
    • /
    • pp.137-143
    • /
    • 2017
  • Acute complicated type B aortic dissection (TBAD) is a potentially catastrophic, life-threatening condition. If left untreated, there is a high risk of aortic rupture, irreversible organ or limb damage, or death. Several risk factors have been associated with acute complicated TBAD, including age and refractory hypertension. In the acute phase, even uncomplicated patients are more prone to develop complications if hypertension and pain are left medically untreated. Innovations in stent graft technologies have incrementally improved outcomes since their first use for this condition in 1999, though improvement is needed in mitigating periprocedural complications, adverse events, and mortality. In the past decade, endovascular repair has become the preferred treatment because of its superior outcomes to open repair and medical therapy. The Valiant Captivia Thoracic Stent Graft System is a third-generation endovascular stent graft with advancements in minimally invasive delivery, conformability to the anatomy, and the minimization of adverse sequelae. Herein, this stent graft is briefly reviewed and its 3-year outcomes are presented. Freedom from all-cause and dissection-related mortality was 79.1% and 90.0%, respectiv ely. The Valiant Captiv ia Stent Graft represents a safe, effective intervention for acute complicated TBAD. Continued surveillance is needed to verify its longer-term durability.

Serious Complications after Self-expandable Metallic Stent Insertion in a Patient with Malignant Lymphoma

  • Cho, Sung Bae;Cha, Seon Ah;Choi, Joon Young;Lee, Jong Min;Kang, Hyeon Hui;Moon, Hwa Sik;Kim, Sei Won;Yeo, Chang Dong;Lee, Sang Haak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.78 no.1
    • /
    • pp.31-35
    • /
    • 2015
  • An 18-year-old woman was evaluated for a chronic productive cough and dyspnea. She was subsequently diagnosed with mediastinal non-Hodgkin lymphoma (NHL). A covered self-expandable metallic stent (SEMS) was implanted to relieve narrowing in for both main bronchi. The NHL went into complete remission after six chemotherapy cycles, but atelectasis developed in the left lower lobe 18 months after SEMS insertion. The left main bronchus was completely occluded by granulation tissue. However, the right main bronchus and intermedius bronchus were patent. Granulation tissue was observed adjacent to the SEMS. The granulation tissue and the SEMS were excised, and a silicone stent was successfully implanted using a rigid bronchoscope. SEMS is advantageous owing to its easy implantation, but there are considerable potential complications such as severe reactive granulation, stent rupture, and ventilation failure in serious cases. Therefore, SEMS should be avoided whenever possible in patients with benign airway disease. This case highlights that SEMS implantation should be avoided even in malignant airway obstruction cases if the underlying malignancy is curable.

Flexible covered stent ; development and clinic application (Flexible covered stent의 개발과 임상응용)

  • Suh, S.W.;Kim, I.Y.;Hong, T.M.;Kim, W.K.;Choo, S.W.;Do, Y.S.;Choo, I.W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.335-336
    • /
    • 1996
  • Flexible, self-expanding metallic stent were developed using igzag wire bend and segmented polyurethane. Mechanical properties of these stents were tested using INSTRON. These stents were used for palliative treatment of mallignant esophagogastric strictures(3 case) and bawl preparation of collorectal obstruction(10 case). All stents were inserted with fluoroscopic guidance without techinal failures. According to the results, these stents are easy to insert, safe, and very effective for dilation of strictures in curved GI tract.

  • PDF

Optimal endoscopic drainage strategy for unresectable malignant hilar biliary obstruction

  • Itaru Naitoh;Tadahisa Inoue
    • Clinical Endoscopy
    • /
    • v.56 no.2
    • /
    • pp.135-142
    • /
    • 2023
  • Endoscopic biliary drainage strategies for managing unresectable malignant hilar biliary obstruction differ in terms of stent type, drainage area, and deployment method. However, the optimal endoscopic drainage strategy remains unclear. Uncovered self-expandable metal stents (SEMS) are the preferred type because of their higher functional success rate, longer time to recurrent biliary obstruction (RBO), and fewer cases of reintervention than plastic stents (PS). Other PS subtypes and covered SEMS, which feature a longer time to RBO than PS, can be removed during reintervention for RBO. Bilateral SEMS placement is associated with a longer time to RBO and a longer survival time than unilateral SEMS placement. Unilateral drainage is acceptable if a drainage volume of greater than 50% of the total liver volume can be achieved. In terms of deployment method, no differences were observed in clinical outcomes between side-by-side (SBS) and stent-in-stent deployment. Simultaneous SBS boasts a shorter procedure time and higher technical success rate than sequential SBS. This review of previous studies aimed to clarify the optimal endoscopic biliary drainage strategy for unresectable malignant hilar biliary obstruction.

A Mouse Colon Model to Investigate Stent-Induced Tissue Hyperplasia (쥐 대장에서 스텐트 삽입 후 발생하는 조직 과증식 모델 형성을 위한 연구)

  • Kim, Min Tae
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.439-445
    • /
    • 2020
  • The purpose of this study was to investigate the feasibility of stent placement and the evaluation of tissue hyperplasia caused by bare metallic stent placement in a mouse colon model. In a pilot study, C57BL/6 mouse were used to verify diameter of colon. Mean diameter size was 4.05 mm. Twenty C57BL/6 mice were divided into two groups to assess differing stent diameters (Group A, 5 mm diameter; Group B. Group B, 4 mm diameter). Follow-up, 1-week fluoroscopic imaging, 4-week endoscopic imaging were obtained. Mice were sacrificed 4-week after stent placement. Microscopic findings were evaluated. Stent placement was technically successful except one mouse in Group A. Data from the mouse was omitted. During follow-up, five mice in Group A died within 7 days after stent placement, and one stent in Group B was migrated into the rectum. The incidence of stent-related complication was 60% and 10% between group A and Group B, respectively. Gross and Endoscopic findings showed tissue hyperplasia through the mesh, and all the stents had become incorporated into the wall of the colon. Microscopic findings were no statistically significant difference. colonic stent placement was technically feasible, and stent-induced tissue hyperplasia was evident in a mouse model. With stent large size, there was the highest incidence of colon perforation.