• Title/Summary/Keyword: Metal-framework

Search Result 258, Processing Time 0.031 seconds

Evaluation of marginal and internal gaps in single and three-unit metal frameworks made by micro-stereolithography

  • Kim, Dong-Yeon;Lee, Ha-Na;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.239-243
    • /
    • 2017
  • PURPOSE. The purpose of this study is to compare single and three-unit metal frameworks that are produced by micro-stereolithography. MATERIALS AND METHODS. Silicone impressions of a selected molar and a premolar were used to make master abutments that were scanned into a stereolithography file. The file was processed with computer aided design software to create single and three-unit designs from which resin frameworks were created using micro-stereolithography. These resin frameworks were subjected to investment, burnout, and casting to fabricate single and three-unit metal ones that were measured under a digital microscope by using the silicone replica technique. The measurements were verified by means of the Mann-Whitney U test (${\alpha}=.05$). RESULTS. The marginal gap was $101.9{\pm}53.4{\mu}m$ for SM group and $104.3{\pm}62.9{\mu}m$ for TUM group. The measurement of non-pontics in a single metal framework was $93.6{\pm}43.9{\mu}m$, and that of non-pontics in a three-unit metal framework was $64.9{\pm}46.5{\mu}m$. The dimension of pontics in a single metal framework was $110.2{\pm}61.4{\mu}m$, and that of pontics in a three-unit metal framework was $143.7{\pm}51.8{\mu}m$. CONCLUSION. The marginal gap was smaller for the single metal framework than for the three-unit one, which requires further improvement before it can be used for clinical purposes.

A STUDY OF PRECISE FIT OF THE CAM ZIRCONIA ALL-CERAMIC FRAMEWORK (CAM Zirconia 완전도재 구조물의 정밀 적합도에 관한 연구)

  • Jeon Mi-Hyeon;Jeon Young-Chan;Jeong Chang-Mo;Lim Jang-Seop;Jeong Hee-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.5
    • /
    • pp.611-621
    • /
    • 2005
  • State of problem: Zirconia all-ceramic restoration fabricated with CAM system is on an increasing trend in dentistry. However, evaluation of the marginal and internal fits of zirconia bridge seldomly have been reported. Purpose: This study was to evaluate the at of margin and internal surface in posterior 3-unit zirconia bridge framework fabricated with CAM system(DeguDent, Germany). Material and Method: Preparations of secondary premolar and secondary molar on artificial resin model were performed for fabrication of 3-unit posterior bridge framework. Fits of 5 zirconia bridge framework were compared with 5 precious ceramo-metal alloy framework(V-GnathosPlus, Metalor, Switzerland), and prepared margins were designed to chamfer and shoulder finishing line. Each framework was cemented to epoxy resin model with reinforced glass ionomer(FujiCEM, GC Co., Japan), embedded in acrylic resin and sectioned in two planes, mesio-distal and buccolingual. Samples were divided into six pieces by sectioning and had two pieces of each surface(i.e mesial, distal, buccal and lingual surface) per abutment, so there were eight measuring points in each abutment. External gap was measured at the margin and internal gaps were measured at the margin, axial and occlusal surface. Gaps were observed under the measuring microscope(Compact measuring microscope STM5; Olympus, Japan) at a magnification of $\times100$. T-test were used to determine the statistic significance of the different gaps between zirconia and metal framework. Results and Conclusion: 1. External and internal marginal gaps of zirconia and metal framework were in clinically acceptable range. External marginal gaps were not different significantly between zirconia$(81.9{\mu}m)$ and metal $(81.3{\mu}m)$ framework and internal marginal gaps of zirconia $(44.6{\mu}m)$ were smaller than those of metal framework $(58.6{\mu}m)$. 2. Internal axial gaps of zirconia framework$(96.7{\mu}m)$ were larger than those of metal frame-work$(78.1{\mu}m)$ significantly and adversely, internal occlusal gaps of zirconia frame-work$(89.4{\mu}m)$ were smaller than those of metal framework $(104.9{\mu}m)$ significantly. 3. There were no significant differences in external and internal marginal gaps between chamfer and shoulder finish line when zirconia frameworks were fabricated.

Manufacturing of metal-framework for maxillary removable partial dentures using milling wax-blocks (Wax-block milling을 이용한 상악 가철성 국소의치 금속구조물 제작 증례)

  • Seo, A-Ra;Kwon, Soon-Suk
    • Journal of Technologic Dentistry
    • /
    • v.44 no.1
    • /
    • pp.24-30
    • /
    • 2022
  • This research introduces the manufacturing process of the metal-framework of one of the maxillary partial dentures, the "obturator", using milling wax-blocks, for patients with palate loss due to oral cancer. It explains the protocol of taking the patient's oral impression, preparation of a working cast, scanning, designing using a computer-aided design program, investing the milling wax-blocks, and completing the obturator. This method does not follow the traditional wax and agar process thereby reducing the errors arising during the manufacturing process and decreasing the time, material, and labor required. Moreover, the retention, stability, and compatibility of the metal framework were observed to be high in both the working cast and oral cavity.

Evaluation of marginal and internal gap of three-unit metal framework according to subtractive manufacturing and additive manufacturing of CAD/CAM systems

  • Kim, Dong-Yeon;Kim, Eo-Bin;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.6
    • /
    • pp.463-469
    • /
    • 2017
  • PURPOSE. To evaluate the fit of a three-unit metal framework of fixed dental prostheses made by subtractive and additive manufacturing. MATERIALS AND METHODS. One master model of metal was fabricated. Twenty silicone impressions were made on the master die, working die of 10 poured with Type 4 stone, and working die of 10 made of scannable stone. Ten three-unit wax frameworks were fabricated by wax-up from Type IV working die. Stereolithography files of 10 three-unit frameworks were obtained using a model scanner and three-dimensional design software on a scannable working die. The three-unit wax framework was fabricated using subtractive manufacturing (SM) by applying the prepared stereolithography file, and the resin framework was fabricated by additive manufacturing (AM); both used metal alloy castings for metal frameworks. Marginal and internal gap were measured using silicone replica technique and digital microscope. Measurement data were analyzed by Kruskal-Wallis H test and Mann-Whitney U-test (${\alpha}=.05$). RESULTS. The lowest and highest gaps between premolar and molar margins were in the SM group and the AM group, respectively. There was a statistically significant difference in the marginal gap among the 3 groups (P<.001). In the marginal area where pontic was present, the largest gap was $149.39{\pm}42.30{\mu}m$ in the AM group, and the lowest gap was $24.40{\pm}11.92{\mu}m$ in the SM group. CONCLUSION. Three-unit metal frameworks made by subtractive manufacturing are clinically applicable. However, additive manufacturing requires more research to be applied clinically.

Alternate metal framework designs for the metal ceramic prosthesis to enhance the esthetics

  • Vernekar, Naina Vilas;Jagadish, Prithviraj Kallahalla;Diwakar, Dr Srinivasan;Nadgir, Ramesh;Krishnarao, Manjunatha Revankar
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.3
    • /
    • pp.113-118
    • /
    • 2011
  • PURPOSE. The objective of the present study was to evaluate the effect of five different metal framework designs on the fracture resistance of the metal-ceramic restorations. MATERIALS AND METHODS. For the purpose of this study, the central incisor tooth was prepared, and the metal analogue of it and a master die were fabricated. The counter die with the 0.5 mm clearance was used for fabricating the wax patterns for the metal copings. The metal copings with five different metal framework designs were designed from Group 1 to 5. Group 1 with the metal collar, Group 2, 3, 4 and 5 with 0 mm, 0.5 mm, 1 mm and 1.5 mm cervical metal reduction respectively were fabricated. Total of fifty metal ceramic crown samples were fabricated. The fracture resistance was evaluated with the Universal Testing Machine (Instron model No 1011, UK). The basic data was subjected to statistical analysis by ANOVA and Student's t-test. RESULTS. Results revealed that the fracture resistance ranged from 651.2 to 993.6 N/$m^2$. Group 1 showed the maximum and Group 5 showed the least value. CONCLUSION. The maximum load required to fracture the test specimens even in the groups without the metal collar was found to be exceeding the occlusal forces. Therefore, the metal frameworks with 0.5 mm and 1 mm short of the finish line are recommended for anterior metal ceramic restoration having adequate fracture resistance.

EFFECT OF SECONDARY HEAT TREATMENT ON DIMENSIONAL CHANGES OF ACRYLIC RESIN PARTIAL DENTURE BASE (2차 가열에 의한 국소의치상의 변형에 관한 실험적 연구)

  • Jang, Byung-Gun;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.27 no.1
    • /
    • pp.193-211
    • /
    • 1989
  • The purpose of this study was to investigate the effect of secondary heat treatment on dimensional changes of acrylic resin partial denture base. For this study, 6 specimens were made: 2 groups of 2 specimens, each was treated with $125^{\circ}C$ dry heat and glycerine heat for 3 minutes, and the others were prepared for control group. The change of the internal diameter of specimens were measured after 3 hrs, 1 day, 1 week, 2 weeks, 4 weeks by three-dimensional space analyzer. The results were as follows : 1. All of the acrylic resin denture bases showed tissue ward thermal contraction. 2. Thermal contraction of the mesial area reinforced with metal framework was lesser than that of the distal area without metal framework. 3. Thermal contraction of the lingual flange reinforced with metal framework occured more slowly than that of the buccal flange without the metal framework. 4. The thermal contraction of dry heat treated acrylic resin base, compared to glycerine heat group, was moderately greater and occurred acutely.

  • PDF

Understanding the Mechanism of Hydrogen Adsorption into Metal Organic Frameworks (Metal-Organic Framework의 수소 흡착 메커니즘의 이해)

  • Lee, Tae-Bum;Kim, Dae-Jin;Yoon, Ji-Hye;Choi, Sang-Beom;Kim, Ja-Heon;Choi, Seung-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.634-637
    • /
    • 2005
  • Hydrogen adsorption mechanism onto the porous metal-organic frameworks (MOFs) has been studied by density functional theory calculation. The selected functionals for the predict ion of interact ion energies between hydrogen and potential adsorption sites of MOF was utilized after the evaluation with the various functionals for interaction energy of $H_2C_6H_6$ model system the adsorption energy of hydrogen molecule into MOF was investigated with the consideration of the favorable adsorption sites and the orientations. We also calculated the second favorable adsorption sites by geometry optimization using every combination of two first absorbed hydrogen molecules. Based on the calculation of first and second adsorption sites and energies, the hydrogen adsorption into MOF follows a cooperative mechanism in which the initial metal sites initiate the propagation of the hydrogen adsorption on the whole frameworks. In addition, it was found that the interaction strength between the simple benzene ring with hydrogen is significantly reinforced when the benzene ring has been incorporated into the framework of MOFs.

  • PDF

Green synthesis of aluminum-based metal organic framework for the removal of azo dye Acid Black 1 from aqueous media

  • Jung, Kyung-Won;Choi, Brian Hyun;Lee, Seon Yong;Ahn, Kyu-Hong;Lee, Young Jae
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.67
    • /
    • pp.316-325
    • /
    • 2018
  • Aluminum based metal-organic framework using a di-carboxylate linker succinic acid (Al-SA MOF), are synthesized in water with minimal generation of secondary pollutants. The physicochemical properties of Al-SA MOF were examined, followed by its utility for the adsorption of Acid Black 1 (AB1) in aqueous media. Influences of key parameters such as pH, contact time, initial AB1 concentration,temperature, and selectivity on the adsorption process were assessed. A series of adsorption mechanisms are proposed, which involve electrostatic, hydrogen bonding, and hydrophobic interactions. These findings suggest that Al-SA MOF is a potent candidate in removing complex azo dyes molecules from aqueous media.