A Study on the Sensibility Evaluation on the Color Temperatures of Electrodeless HID Lamp (무전극 HID 램프의 색온도 감성평가에 관한 연구)

  • Pak, Hyensou;Park, Bonjour;Jang, Woojin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.4
    • /
    • pp.9-15
    • /
    • 2014
  • An experiment was carried out to evaluate the emotion and sensibility evoked from the different color temperatures(CCT) of electrodeless HID (ELHID) lamp. For this purpose, three ELHID lamps and a metal halide lamp were used as the experimental light sources and thirty Korean adjectives related to the lighting affectiveness were selected for the evaluation. The results showed that ELHID lamps induced different sensibilities according to their color temperature. In particular, 6500 K ELHID was similar to metal halide which has the CCT of 5600 K in the evaluation. Based on the results, we suggested some Korean adjectives and their corresponding English ones which are thought to be suitable for the verbal descriptions of ELHID lamps.

Operating Performance of hair-tail angling vessel using the LED and metal halide fishing lamp combination (LED와 메탈핼라이드 집어등을 겸용한 갈치채낚기 어선의 조업 성능)

  • An, Heui-Chun;Bae, Bong-Seong;Lee, Kyoung-Hoon;Park, Seong-Wook;Bae, Jae-Hyun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.48 no.4
    • /
    • pp.337-345
    • /
    • 2012
  • One of representative Korean fisheries, jigging and angling has 5,700 vessels for squid and hairtail. Hairtail angling is the most typical fishery in Jeju and has an enormous impact on regional economy. However, the price hike in oil and labor costs triggered the necessity of developing a high efficient and energy saving fish luring lamp in recent times. For that reason, this study aimed to analyze the fishing performance of the aircooled LED lamp targeting hairtail angling fishery. The experiment was conducted from September through October in 2009-2011 for a 9.77 ton of fishing vessel setting up 100 lamps. The fishing performance was tested compared with 6 vessels using metal halide lamps in the same waters. As the LED lamp's performance goes up, different lamps were used in 2008 for 80W, 2009 for 120W and 2011 for 180W respectively. The catch and CPUE of the experimental vessel have gradually increased respectively taking the $4^{th}$ and $6^{th}$ place in 2009, the $4^{th}$ and $2^{nd}$ place in 2010, the $1^{st}$ and $1^{st}$ place in 2011 among the 7 vessels. In summary, the LED fishing lamp showed higher fishing performance than comparison groups. It saved 33% of oil consumption and cut down on operating expenses and greenhouse gases emission.

Analysis of Wall Blackening Reason in Ceramic Metal Halide Lamp by Shape of Arc-tube and Degradation Condition (방전관 형태 및 열화 조건에 따른 세라믹 메탈할라이드 램프의 흑화원인 분석)

  • Kim, Woo-Young;Lee, Se-Il;Yang, Jong-Kyung;Jeong, Young-Gi;Park, Dae-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.12
    • /
    • pp.2262-2267
    • /
    • 2010
  • In order to analyze the reason of wall blackening, which affect the decline of lifetime in a ceramic metal halide lamp, we carried out the deterioration of ceramic tubes by a change in operating conditions with arc tubes of two types of spherical and cylindrical, and we have confirmed the cause of wall blackening through the analysis of element composition and spectrum from SEM/EDS and spectrum analyzer. Wall blackening of tungsten was shown by sputtering from ignition in 20 minute on/off condition and wall blackening from chemical reaction between PCA wall and rare earth halides was shown significantly in a condition without on/off test. Especially, the wall blackening and the decline of luminous flux were reduced by inner convection in spherical type arc tube. Moreover, the color temperature and color coordinate were changed by reduction of emission spectrum of Dy which causes the chemical reaction with PCA wall.

High-Power Electronic Ballast Design for Metal-Halide Lamp without Acoustic Resonance (음향 공명 현상을 제거한 MHL용 고출력 전자식 안정기 설계)

  • Park, Chong-Yun;Kim, Ki-Nam;Lee, Bong-Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1187-1194
    • /
    • 2008
  • This paper presents a high-power electronic ballast for a metal-hallide lamp(MHL) that employs frequency modulation(FM) technique to eliminate acoustic resonance(AR). The proposed ballast consists of a full-bridge rectifier, a power factor correction(PFC) circuit, a full-bridge(FB) inverter, an ignitor using LC resonance and an FM control circuit. Whereas a manual PFC provides advantages in terms of high reliability and low cost for constructing the circuit, it is difficult to supply a stable voltage because of the output voltage ripple that occurs with a period of 120Hz. Although the ballast can be designed with a small size and a light weight if it is driven at a switching frequency between 1 and 100 kHz, AR will occur if the eigen-value frequency of the lamp coincides with the inverter's operation frequency. The operation frequency was modulated in real time according to the output voltage ripple to compensate for the variation in power supplied to the lamp and eliminate AR. Performance of the proposed technique was validated through numerical analysis, computer simulation using PSPICE and by applying it to an electronic ballast for a prototype 1kW MHL.

Development of the Adaptive Igniter for Expanding HID Lamp Life (HID 램프 수명 연장을 위한 적응형 점화기 개발)

  • Park, Chong-Yeun;Jo, Gye-Hyun;Song, Myoung-Suk
    • Journal of Industrial Technology
    • /
    • v.24 no.A
    • /
    • pp.75-81
    • /
    • 2004
  • The metal halide lamps are now widely used in the application and commercial lighting due to their attracting properties such as good color rendering and high efficiency. But, they have the serious problem of acoustic resonance for high frequency operation and they need the high voltage to ignite. So, they have not been applied to indoors. Over the past few years, a considerable number of studies have been conducted on the electronic ballast together with hot restarting and resonance phenomenon. But, very few attempts have been made with the adaptive ignition method according to the lamp state. In this paper, electronic ballast is proposed for metal halide lamps with an igniter for adaptive ignition. The proposed electronic ballast can generate different ignition voltages according to the arc tube state.

  • PDF

Development of the Igniter to Expand HID Lamp Life (HID 램프 수명 연장을 위한 점화기 개발)

  • 조계현;송명석;박종연
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.7
    • /
    • pp.370-376
    • /
    • 2004
  • The metal halide lamps are now widely used in the application and commercial lighting due to their attracting properties such as good color rendering and high efficiency. But, they have the serious problem of acoustic resonance for high frequency operation and they need the high voltage to ignite. So, they have not been applied to indoors. Over the past few years, a considerable number of studies have been conducted on the electronic ballast together with hot restarting and resonance phenomenon. But, Very few attempts have been made with the adaptive ignition method according to the lamp state. In this paper, electronic ballast is proposed for metal halide lamps with an igniter for adaptive ignition. The proposed electronic ballast can generate different ignition voltages according to the arc tube state.

The Development of Dimmable Electronic Ballast for 250W Metal Halide Lamp (250 Watt 메탈할라이드 램프용 전자식 Dimming 안정기 개발)

  • Park, Chong-Yeon;Jung, Kwang-Hyun;Shin, Dong-Suk;Park, Young-Gil
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.103-107
    • /
    • 2006
  • In this paper, the dimmable electronic ballast for the 250W metal halide lamp was realized by three stage structure. We developed stable the dimming ballast by using a Micro-controller, and measured the output wattage in the dimming range(illumination) from 100% to about 20%. Under the 35% dimming level, it is possible to cause the redution of lamp's life. The dimming performance can reduce the light system's wattage but can reduce the luminance efficiency (lux/watt).

  • PDF

(Development of A Digital Controller of The Electronic Ballast using High Frequency Modulation Method for The Metal Halide Lamp) (메탈 할라이드 램프용 고주파 변조 방식 전자식 안정기의 디지털 제어기 개발)

  • O, Deok-Jin;Kim, Hui-Jun;Jo, Gyu-Min
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.3
    • /
    • pp.228-238
    • /
    • 2002
  • This paper presents a digital controller of the electronic ballast using high frequency modulation method for the metal halide lamp. The proposed controller includes the control algorithm for soft starting, no load protection, over current protection and power control. The proposed digital controller, moreover, has the high frequency modulation scheme and the tracking algorithm to avoid acoustic resonance phenomena. For the math production with the low cost using the ASICs (Application Specific Integrated Circuit), the proposed digital controller has been designed with the FPGAs(Field Programmable Gate array) only, without any microprocessor. In this paper, the detail digital control algorithms are described and the experimental results of prototype 150w metal halide electronic ballast are presented.

Development of Simulator to Electronic Ballast for HID Lamp (HID Lamp용 전자식 안정기의 시뮬레이터 개발)

  • 장목순;조계현;조호찬;박종연
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.1-8
    • /
    • 2002
  • The electronic ballast have much more shaking of arc than magnetic ballast because of acoustic resonance phenomenon. but it has used mare than before. In this paper, we made metal halide lamp modeling by modifying modeling of mercury lamp. To avoid acoustic resonance phenomenon, We calculated acoustic resonance frequency band. We proposed design of LCC circuit. Also, electronic ballast simulator for metal halide lamp was developed by simulink LCC parameters of inverter was decided on the basis of simulation results. After development of prototype ballast, it was verified the characteristics of simulator.

A High Frequency Complex Modulation Method of the Electronic Ballast for Metal Halide Lamps (메탈 할라이드 램프용 전자식 안정기의 고주파 복합 변조법)

  • 오덕진;김희준;조규민
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.40 no.3
    • /
    • pp.215-224
    • /
    • 2003
  • This paper presents an electronic ballast using a novel complex modulation method for the metal halide lamp. The proposed modulation method, which has a modulating signal of swept complex frequency, can eliminate the acoustic resonance more effectively than the conventional modulation method, which has a modulating signal of constant frequency. For the purpose of future application specific integrated circuits (ASIC). the controller of the proposed ballast has been designed only with erasable programmable logic devices (EPLDs), but without a microprocessor. In this paper, detailed proposed modulation schemes are described and experimental results on the proto type 150W metal halide lamp ballast with the proposed modulation method ate discussed.