Browse > Article
http://dx.doi.org/10.5207/JIEIE.2002.16.2.001

Development of Simulator to Electronic Ballast for HID Lamp  

장목순 (강원대학교 전기공학과)
조계현 (동대학원 전기공학과 (박사과정))
조호찬 (동대학원 전기공학과 (석사과정))
박종연 (강원대)
Publication Information
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers / v.16, no.2, 2002 , pp. 1-8 More about this Journal
Abstract
The electronic ballast have much more shaking of arc than magnetic ballast because of acoustic resonance phenomenon. but it has used mare than before. In this paper, we made metal halide lamp modeling by modifying modeling of mercury lamp. To avoid acoustic resonance phenomenon, We calculated acoustic resonance frequency band. We proposed design of LCC circuit. Also, electronic ballast simulator for metal halide lamp was developed by simulink LCC parameters of inverter was decided on the basis of simulation results. After development of prototype ballast, it was verified the characteristics of simulator.
Keywords
MHD lamp; Simulator; Acoustic Resonance; Electronic Ballast;
Citations & Related Records
연도 인용수 순위
  • Reference
1 E. L. Laskowski, “Dynamics and Control of a Mercury ARC Lamp”, Doctoral thesis The Cleveland State University pp.59-107 Sep, 1978.
2 M. C. Cosby, Jr, and R. M. Nelms, “A Resonant Inverter for Electronic Ballast applications”, IEEE Trans on I.E Col41, No.4, pp.418-425 Aug, 1994.   DOI   ScienceOn
3 S. wada, A. Okada, S. Morii, “Study of HID Lamps with Reduced Acoustic Resonances”, J. Illum pp.162-175, 1987.
4 M. Nakamichi and M.Ihara, “Trands of Electronic Technologies for HID Lamps Luminaries”, J.Illum. Inst. Jpn, vol 77. No.5, pp.233-237, 1993.   DOI
5 김기정 “메탈할라이드 램프의 음향공명현상을 감소시킨 전자식 안정기의 개발” 강원대학교 전기공학과 대학원 공학박사학위논문. 2. 2000.
6 “Special Issue for Metal Halide Lamps and its applications”, J. Illum. Jpn, Inst, Jpn, vol. 77, No.12, pp.4-35.