• Title/Summary/Keyword: Metal line

Search Result 929, Processing Time 0.031 seconds

Immediate implant placement into extraction sites with periapical lesions in the esthetic zone: a case report (치근단 병소를 가진 치아의 발치 후 즉시 임플란트 식립 및 보철을 통한 심미성 회복)

  • Yi, Jae-Young;Kim, Jee-Hwan;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.191-197
    • /
    • 2012
  • Esthetics is important in restoring maxillary anterior area. Alveolar bone resorption and loss of interdental papilla may be minimized by immediate implantation. Previous studies showed successful results with the immediate implantation in healthy extraction socket, while many of these studies objected the immediate implantation into extraction sites with periapical lesions. Recent studies, however, reported successful results of the immediate implantation into extraction sites with periapical lesions with careful debridement of extraction sockets and general medication of antibiotics prior to implantation. A 73-year-old female visited the department of Prosthodontics in ${\bigcirc}{\bigcirc}$ University Dental Hospital with the chief complaint of fallen post-core and crown on left maxillary incisor. Although the incisor was with vertical root fracture and periapical lesion, the immediate implantation following the extraction of tooth was planned. Thorough socket debridement, irrigation with chlorhexidine, and tetracycline soaking were followed by immediate implantation. The general medication of antibiotics (Moxicle Tab.$^{(R)}$, 375 mg) was prescribed before and after the surgery. Immediate provisional restoration was delivered two days after the surgery, and the definitive metal-ceramic restoration was placed about six months later after reproducing the emergence profile from the provisional restoration. This case presents satisfying result esthetically and functionally upto two years after the placement of prosthesis with the harmonious gingival line and no loss of marginal bone.

Assessment of Airborne Welding Fume Concentration for Some Manufacturing Industries in Busan

  • Cha, Min-Ho;Kim, Jeong-Won;Kim, Jong-Eun;Cho, Young-Ha;Moon, Deog-Hwan
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.6
    • /
    • pp.506-512
    • /
    • 2007
  • This study was conducted to describe the exposure levels of welding fumes by the type of manufacturers, work process, welding type and the size of manufacturers, and to find out the trend of chronological changes of airborne welding fume levels. The subjects of this study were 509 manufacturers, consisting of 11 types of manufacturers, 3 work processes, 7 welding types, in Busan from January, 1997 to December, 2005. Airborne concentration of welding fume was determined by manual of National Institute for Occupational Safety and Health (NIOSH), and the data were analyzed by using SPSS 10.0 for Windows program. The mean concentration of airborne welding fume in all manufacturers was $1.29\;mg/m^3$ (Range: $0.01{\sim}3.00\;mg/m^3)$. The level of welding fume was the highest, as $1.96\;mg/m^3$, for manufactures of motor vehicles, trailers and semi-trailers, which was lower than $5.0\;mg/m^3$ of 8 hr-TWA in Korean permissible exposure limit for welding fume. There was a significant difference in the mean levels of welding fumes by work process, showing the highest in welding workshop ($1.39\;mg/m^3$), followed by pipeline welding workshop ($1.26\;mg/m^3$) and engineering workshop ($1.20\;mg/m^3$). Among welding types, the mean level of welding fume was the highest in the type of $CO_2$ & arc welding, as $1.46\;mg/m^3$, followed by $CO_2$ welding ($1.40\;mg/m^3$), shielded metal arc welding ($1.31\;mg/m^3$), spot welding ($1.27\;mg/m^3$), and so on. The highest mean level of welding fume was $1.58\;mg/m^3$ in work process of pipe line welding workshop for the manufacturers of basic iron and steel, and $2.27\;mg/m^3$ in the type of arc welding for the manufactures building ship and boats. By the size of manufacturers, the mean concentration of welding fume for manufactures in small scale with less than 50 workers was the highest as $1.45\;mg/m^3$ (Range: $0.07{\sim}3.00\;mg/m^3)$. The mean level of welding fume was the highest as $1.39\;mg/m^3$ both in 1997 and in 2005, showing a trend of fluctuating periodically within a range of $1.10{\sim}1.39\;mg/m^3$. The above results suggested that more effective control program for work environment producing welding fumes should be developed and applied since there were significant variations in welding fume levels by the type of manufacturers, work processes, welding types, the size of manufactures, and by year.

To Compare and Analyze Costumes in the Film "The Great Gatsby" and Y&Kei Collection (영화 "The Great Gatsby" 의상과 Y&Kei 컬렉션 비교 분석)

  • O, Ji-Hye;Lee, In-Seong
    • The Research Journal of the Costume Culture
    • /
    • v.16 no.6
    • /
    • pp.1050-1063
    • /
    • 2008
  • A movie is a fiction made on a basis of an author's and a writer's imagination, but all sorts of properties mixed with each other and most realistically expresses the era which becomes the background of a movie and acts as a carrier that connects designers with consumers. Thus, this study was carried out to review how the fashion products that designer's intention and commercial value added are expressed in collections by comparing and analysing the costumes in the movie "The Great Gatsby" that described the life of America's upper-class in 1920s and the 04 S/S Y&Kei collection which were proceeding after getting inspiration from this movie. For this, literature materials were inspected in order to make a theoretical review on social and cultural background and costumes history background in 1920s and the photo materials on movie costume were collected and analysed using DVD video captures, as well as the photo materials on 04 S/S Y&Kei were collected and analyzed through the institute providing domestic fashion information. The following conclusion was deduced through this study. First, in 1920s which becomes the background of this study, the slim shape of Flapper which looks like a young and boy became an ideal figure condition and the straight silhouette with low waist line and the short skirt that rose to knee was popular. Second, as a result of analysing movie costume by classifying it in silhouette, colors, and materials, straight silhouette of low waistline with a near colored - tone seen in the pastel series, including white, beige, pink, and gray was mainly constituted and the metal colors like silver and gold were used. As a material, chiffon, satin, velvet, flower patterned prints, and beads were used, which represented luxurious life of women in the upper classes. Third, as a result of comparing and analysing, it turned out that there was a similarity. However, in dress collection for a heroine, some dissimilarity differentiated from a movie costumes was found out in that the dresses in collection expressed moderate beauty and modernism and elegant beauty at the same time by matching a variety of materials and using black color.

  • PDF

Analysis of Studies on Ojeok-san for Establishment of Evidence Based Medicine (EBM 기반 구축을 위한 오적산 연구 논문 분석)

  • Lee, Nam-Hun;Ha, Hye-Kyung;Lee, Ho-Young;Jung, Da-Young;Choi, Ji-Yoon;Lee, Jun-Kyoung;Shin, Hyun-Kyoo
    • Herbal Formula Science
    • /
    • v.16 no.2
    • /
    • pp.1-9
    • /
    • 2008
  • Objective : The purpose of this report was to provide the information about activity and safety of Ojeok-san by analyzing domestic/international papers about Ojeok-san. Methods : Domestic/international papers related to Ojeok-san were reviewed and analyzed. These papers were then classified by year, experimental method and subject. Results : The following results were obtained in this study. 1. The studies of Ojeok-san started from 1984 and has continuously increased. The studies were mainly focused on experimental models rather than clinical studies. 2. By subject, papers related to safety were most common with 5 papers among 20 papers. Besides there were papers related to efficacy of analgesic, anti-hyperlipidemic, anti-blood stasis and treatment for uterine myoma. 3. The papers related to safety were mainly focused on the effect of Okeok-san on liver function, renal function or metal concentration of organs such as blood, brain, liver, kidney and bone. Ojeok-san proved to be safe, but more clinical studies regarding the safety are needed hereafter. 4. Papers related to analgesic, anti-pyretic, anti-phlogistic activities of Ojeok-san were in vivo studies, and other papers were about anti-hyperlipidemic activity, apoptosis inducing activity on uterine myeloma cell line and anti blood static activity on hydrocortisone acetate induced blood statis model. 5. Case reports were about anti-lipidemia, analgesic effect for mastalgia/back pain and anxiety disorder due to climacteric changes. Conclusion : Ojeok-san is being used in various ways with analgesic, anti-pyretic, anti-phlogistic, anti-hyperlipidemic, anti-tumor or anti-blood statis activity. However, mechanism study should be conducted at the molecular biology level and more clinical studies on the efficacy of Ojeok-san are needed.

  • PDF

석류석과 녹염석간의 철-알루미늄 교환에 관한 실험암석학적 연구

  • 김형식;김진섭;김기영;이설경;신의철;권용완
    • The Journal of the Petrological Society of Korea
    • /
    • v.3 no.3
    • /
    • pp.185-195
    • /
    • 1994
  • An experimental study of iron-aluminium partitioning between synthetic garnet and synthetic epidote was carried out, as equilibrium was maintained in the exchange reaction expressed as follows : $Ca_3Fe_2Si_3O_12\+\2\Ca_2Al_2AlSi_3O_12$(0H) = $Ca_3Al_2Si_3O_12\+\Ca_2Al_2FeSi_3O_12$(0H) Temperature has a pronounced effect on the distribution of Fe and A1 between the minerals. However, the pressure effect is not so drastic as in the exchange reaction. With increasing temperature, $Fe^{+3}$ becomes redistributed from garnet into epidote, whereas A1 becomes redistributed from epidote into garnet. This is in line with the general principle of phase correspondence, as the temperature increases the more electropositive metal aluminium redistributes from epidote into garnet. The agreement between the experimental results of this study and the natural samples suggests that $K_D=X^{Ep}_{Fe}/X^{Gr}_{Fe}$ may be a useful geothermometer for metamorphic rocks containing garnet and epidote that are close to binary Fe-A1 compounds.

  • PDF

Toxicity Assessment of Heavy Metals (As, Cr and Pb) Using the Rates of Survival and Population Growth in Marine Rotifer, Brachionus plicatilis (해산로티퍼 (Brachionus plicatilis)의 생존 및 개체군 성장률을 이용한 중금속 (As, Cr, Pb) 독성평가)

  • Lee, Ju-Wook;Ryu, Hyang-Mi;Heo, Seung;Hwang, Un-Ki
    • Korean Journal of Environmental Biology
    • /
    • v.34 no.3
    • /
    • pp.193-200
    • /
    • 2016
  • Toxicity assessment of heavy metals (As, Cr and Pb) has been investigated by using the rate of survival and population growth(r) of marine rotifer, Brachionus plicatilis. The survival rate was determined after 24 hours of exposure to As, Cr and Pb. As and Cr reduced survival rate in dose-dependent manner and a significant reduction were occurred at concentration of greater than 30 and $150mg\;L^{-1}$, but Pb had no effect on survival rate. The r was determined after 72 hours of exposure to As, Cr and Pb. As, Cr and Pb reduced r in dose-dependent manner and a significant reduction were occurred at concentration of greater than 5, 25 and $50mg\;L^{-1}$. The toxicity of heavy metals were ranked As>Cr>Pb, with $EC_{50}$ values of 12.98, 82.34 and $110.14mg\;L^{-1}$, respectively. The no-observed-effect-concentration (NOEC) of r in As, Cr and Pb exposure were 1, 12.5 and $50mg\;L^{-1}$, respectively. The lowest-observed-effect-concentration (LOEC) of r in As, Cr and Pb exposure were 5, 25, and $50mg\;L^{-1}$, respectively. From the results, the concentration of As, Cr and Pb (greater than 5, 25 and $50mg\;L^{-1}$, respectively) have toxic effect on the r of B. plicatilis in natural ecosystems. These results (including NOEC and $EC_{50}$) might be useful for the mixing toxicity assessment and toxic guide line of heavy metals in marine ecosystems.

Marginal Fidelity and Fracture Strength of OPTIMAL PRESSABLE CERAMIC Crown according to Margin Types (OPTIMAL PRESSABLE CERAMIC 금관의 변연형태에 따른 변연적합도와 파절강도에 관한 연구)

  • Lee, Ju-Seog;Kim, Ki-Suk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.1
    • /
    • pp.13-25
    • /
    • 2000
  • Optimal Pressable Ceramic is one of the all-ceramic restorations with a shaded translucent pressed core and layering porcelains. The purpose of this study was to evaluate the marginal fidelity according to margin types and measurement sites, and to evaluate fracture strength according to margin types. Twenty seven OPC crowns made according to 3 types of cervical finishing lines were used in this study. Marginal gaps were measured before and after cementation. A Steromicroscope(SZ-ST(R), Olympus, Japan) was used to measure the space between the margin of OPC crown and the finishing line of metal model. Marginal gaps were measured at the labial, mesial, lingual and distal site, which were demonstrated in advance. Fracture strength testing was carried out using an Instron(Model M100EC, Mecmesin, England) at a cross head speed of 5 mm/min. All crowns were loaded until catastrophic failures occurred. The result were as follow: 1. In comparison according to variable margin before cementation, the marginal gap were increased in chamfer margin($47.50{\pm}18.39{\mu}m$), $120^{\circ}$shoulder margin ($55.21{\pm}14.4{\mu}m$) and $90^{\circ}$shoulder margin($71.18{\pm}13.30{\mu}m$) in ascending order, and there were significant differences between chamfer margin and $90^{\circ}$shoulder margin, $120^{\circ}$shoulder margin and between $120^{\circ}$shoulder margin and $90^{\circ}$shoulder margin respectively(p<0.05). 2. In comparison according to variable margin after cementation, the gap discrepancies were increased in chamfer margin($60.78{\pm}30.37{\mu}m$), $120^{\circ}$shoulder margin($66.67{\pm}11.18{\mu}m$) and $90^{\circ}$shoulder margin($85.78{\pm}17.23{\mu}m$) in ascending order, but there was significant difference only between chamfer margin and $90^{\circ}$shoulder margin(p<0.05). 3. Labio-lingual points showed a better marginal fidelity than that of proximal point(p<0.05). 4. Chamfer margin($48.76{\pm}8.45kgf$) showed higher fracture strength than $120^{\circ}$ shoulder margin($40.57{\pm}7.90kgf$) and $90^{\circ}$ shoulder margin(32.7.90kgf) (p<0.05), but there was significant difference only between chamfer margin and $90^{\circ}$ shoulder margin(p<0.05).

  • PDF

A STUDY ON THE FRACTURE RESISTANCE AND CHARACTERISTICS OF TEETH IN CLASS II CAVITY RESTORATIONS (2급(級) 와동(窩洞) 수복시(修復時) 치아파괴(齒牙破壞) 저항성(抵抗性) 및 귀열양상(龜裂樣相)에 관(關)한 연구(硏究))

  • Joo, Ik-Nam;Park, Sang-Jin;Min, Byung-Soon;Choi, Ho-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.13 no.2
    • /
    • pp.337-348
    • /
    • 1988
  • The purpose of this study was to examine the fracture strength and characteristics of teeth with MOD cavity preparation. Freshly extracted sound maxillary premolars were cleaned and stored in normal saline solution $37^{\circ}C$ for 72 hours before experiments. The roots of teeth were embedded in a self-curing resin, and the exposed crown were maintained in a vertical position by a modelling wax in a brass ring. The MOD cavities were prepared with No. 57 carbide bur under high speed to a depth of 2.0mm and a width of 2.0mm(Fig.1). All the prepared teeth specimens were divided into 7 groups according to the mode of cavity form and restorative materials (Table 1, 2): Group I, unpreapred, intact teeth as control Group II, prepared cavity without restoration Group III, prepared teeth restored with amalgam Group IV, prepared teeth restored with composite resin (P-10) Group V, prepared teeth with beveled enamel margins restored with composite resin (P-10) Group VI, prepared teeth restored with light-cured composite resin (P-30) Group VII, prepard teeth with beveled enamel margins restored with light-cured composite resin (P-30) After placement of restorations, all of the specimens were stored in water at $37^{\circ}C$ for 72 hours before testing. All of the specimens were tested on the Instron Universal Testing machine (No. 6025) in order to evaluate the strength of fracture. One metal ball 5.0mm in diameter contacting the specimens parallel to the occlusal surface was used to in this study (Fig. 1). The fracture characteristics of the specimens were examined with naked eye and in the scanning electron microscope (JSM-20). The results obtained from this study were as follows: 1. The mean fracture strength was the highest in group VI and that in group II was the lowest. 2. The progress of crack of teeth propagated into the pulp cavity. 3. In case of the group of the restored teeth, the crack occurred to be accompanied with cuspal fracture. 4. The crack of restored teeth was initiated along the pulpo-axial line angle of the cavity.

  • PDF

Development of Surface Myoelectric Sensor for Myoelectric Hand Prosthesis (근전의수용 소형 표면 근전위 센서의 개발)

  • Choi, Gi-Won;Sung, So-Young;Moon, Inhyuk
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.42 no.6
    • /
    • pp.67-76
    • /
    • 2005
  • This paper proposes a compact-sized surface myoelectric sensor for the myoelectric hand prosthesis. To fit the surface myoelectric sensor in the socket for the myoelectric hand prosthesis, the sensor should be a compact size. The surface myoelectric sensor is. composed of a skin interface and a single processing circuit that are mounted on a single package. The skin interface has one reference and two input electrodes, and the reference electrode is located in the center of two input electrodes. In this paper we propose two types of sensors with the circle- and bar-shaped reference electrode, but all input electrodes are the bar-shaped. The metal material of the electrodes is the stainless steel (SUS440) that endures sweat and wet conditions. Considering the conduction velocity and the median frequency of the myoelectric signal, we select the inter-electrode distance (IED) between two input electrodes as 18mm, 20mm, and 22 mm. The signal processing circuit consists of a differential amplifier with a band pass filter, a band rejection filter for rejecting 60Hz power-line noise, amplifiers, and a mean absolute value circuit. We evaluate the proposed sensor from the output characteristics according to the IED and the shape of the reference electrode. From the experimental results we show the surface myoelectric sensor with the 18mm IED and the bar-shaped reference electrode is suitable for the myoelectric hand prosthesis.

The PMOLED data driver circuit improving the output current deviation problem (출력 전류 불균일 현상을 개선한 PMOLED 데이터 구동 회로)

  • Kim, Jung-Hak;Kim, Seok-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.1
    • /
    • pp.7-13
    • /
    • 2008
  • This paper proposes a newly structured circuit that can compensate current deviation of a data driver circuit for OLED. A conventional data drivel circuit for OLED cannot compensate the current deviation at the data drivel circuit output terminal generated by MOS process change, but the proposed data drivel circuit can authorize uniform value of current to an OLED panel by calibrating the current deviation at the output terminal. The proposed circuit can minimize current deviation of the output current via process change by connecting the circuit for data output current with a common interconnect line through addition of a switching transistor to the existing data output circuit. The circuit proposed in this paper has been designed based on an OLED panel supporting $128{\times}128$ resolution, and the process used for driver circuit development is 0.35um. As a result of the experiment in this study, the output current of the data driver circuit proposed here has 1% range of error, while 9% range of severe changes was demonstrated in the case of the previous data driver circuit. When using the data driver circuit for OLED proposed in this paper, high definition OLED display can be actualized and the circuit can be applied to mobile display devices requiring high quality display features.