• 제목/요약/키워드: Metal artifacts

검색결과 140건 처리시간 0.022초

Conservation of the Lacquer Artifacts Excavated from Suchon-ri, Gongju, Korea

  • Song, Ji Ae;Jeong, Ah-reum;Kwon, Hyeok-nam;Han, Woo-rim;Lee, Hyun-sang
    • 보존과학회지
    • /
    • 제34권6호
    • /
    • pp.549-556
    • /
    • 2018
  • In November 2011, various artifacts were excavated from the No. 8 stone-lined tomb in Suchon-ri, Gongju by the Chungnam Institute of History and Culture. These included artifacts with lacquered mainframe and silvery metal ornament. These were recovered together with soil and underwent conservation treatment. In this paper, we discuss the scientific analysis and conservation treatment of the lacquered artifacts excavated from the Suchon-ri site. Among our findings is that the artifacts have three layers of lacquer coating and the metal parts are primarily composed of Ag. As the artifacts were recovered with soil from the site, the soil was removed from underneath and inside the artifacts. The inside of the lacquerware was reinforced with rayon paper using 3% funori, and the metal was treated with acrylic resin after removing the acrylic resin previously used to recover the artifact, followed by cleaning. The metal was also internally reinforced with gauze. Finally, the interior reinforcement was made using PVA and resin in pulp and attached with funori to preserve the shape of the lacquerware, and the exposed rayon was finished with acrylic paint. The main advantages of this study are its review of conservation treatment strategies for lacquer artifacts whose numbers have recently increased, and the application of new conservation treatment methods.

척추 MRI 검사 시 척추 유합술로 인한 금속 인공물 억제 방법에 대한 고찰 (Consideration on Methods to Suppress Metal Artifacts Caused by Spinal Fusion during Spine MRI Study)

  • 유세종;권순용;김성호
    • 한국방사선학회논문지
    • /
    • 제17권7호
    • /
    • pp.1123-1131
    • /
    • 2023
  • 본 연구는 척추 MRI 검사 시 척추 유합술로 인한 금속 인공물을 효과적으로 억제하는 방법을 제시하고자 하였다. 이를 위해 척추 수술용 나사로 제작된 팬텀을 제작하여 금속 인공물을 재현하였다. 그리고 1.5T 그리고 3.0T MRI 장치로 영상을 획득하여 자기장 세기에 따른 금속 인공물의 변화를 평가하였다. 더불어 수신대역폭을 200, 400, 800 Hz/PX로 증가시키며 금속 인공물을 평가하였다. 그 결과 1.5T MRI 장치에서 획득한 영상에서 발생한 금속 인공물은 3.0T MRI 장치에서 획득한 영상과 비교하여 약 52.2% 감소하여 유의한 차이를 보였다(p<0.05). 특히, 신호 감쇄 및 신호 누적 영역이 각각 약 52.81%, 42.71% 감소하여 금속 인공물 억제에 큰 효과가 있었다. 반면, 수신대역폭을 200에서 800 Hz/PX까지 증가시키며 영상을 획득한 경우는 1.5T MRI 장치의 경우 최대 8.93%, 3.0T MRI 장치의 경우 최대 10.98% 감소하여 유의미한 효과가 없었다(p>0.05). 본 연구의 결과, 수신대역폭의 증가는 신호 감쇄를 줄여 일부 금속 인공물을 줄였지만 신호 누적을 억제하지 못해 큰 효과가 없었다. 하지만 3.0T에서 1.5T로 자기장의 세기를 줄인 경우, 신호 감쇄와 신호 누적이 크게 감소해 금속 인공물을 효과적으로 개선할 수 있었다. 따라서 척추 유합술로 인한 금속 인공물을 억제하기 위해서는 저 자기장 MRI 장치에서 검사하는 것이 가장 효과적인 방법이라고 할 수 있다.

경산시 임당유적 출토 유물 보존처리-금속 및 칠기유물을 중심으로 (Conservation of artifacts excavated from Imdang, Kyǒngsan Province-Metals and Lacquerware)

  • 유재은;신의경;황진주;고동하
    • 보존과학연구
    • /
    • 통권19호
    • /
    • pp.109-132
    • /
    • 1998
  • According to excavation of Imdang site, these sites were excavated place to a various of sites from Early lron period to the Koryo Kingdom. Artifacts to be conserved were excavated from A, D and E district. Metal artifacts were excavated from D and E district and lacquer ware artifacts were excavated from Adistrict. Metal artifacts including lacquer ware iron sword, imitative bronze mirror, Osujen and bronze artifact with letter and so on. Bronze artifacts were covered with soil and rust and performed consolidation after passivation treatment with Benzotriazole solution. Also, iron artifacts performed desalting treatment with 0.1M sesquicarbonate solution. After desalinization, adhesive of these artifacts were processed with Araldite(rapid type) after consolidation with20%∼30% NAD-10 solution. Lacquer ware artifacts remained fragments of lacquer to be all corroded and soiled. Therefore these artifacts retained its original form. Fragments of lacquer joined with Caparol 1%∼3% solution and the soil of relics coated with PSNY 3%∼6% solution. There were many kinds of lacquer were. Lacquer ware artifacts presumed to a string instrument that provide important clues for lacquer ware research. As for lacquer fragments inquire, paints grain size were $2∼5\mum$ and conformed to vanished three times.

  • PDF

나주 복암리 3호분 출토 철제유물의 금속학적 조사 (Microstructure investigation of iron artifacts excavated from No. 3 tomb of Bogam-ri in Naju City, Chollanam-do Province)

  • 유재은;고형순;황진주
    • 보존과학연구
    • /
    • 통권22호
    • /
    • pp.115-132
    • /
    • 2001
  • No. 3 Tomb of Bogam-ri, in Naju City, Chollanam-do Province, was a site excavated and inspected from 1996 to 1998 and had a various grave forms, including jar-coffins, stone-chambers and stone-cists. Although most of the metal artifacts excavated from it were severely corroded, we could implement microstructure investigation by collecting samples from the iron axes, iron coffin-nails and iron clamps in which the metal parts were remained. The metal structures were inspected by using metallographic microscope and SEM, and fine components analysis was implemented by ICP. To examine the hardness differences in accordance with the structure distribution, we measured the hardness by structures with Vickers hardness testing machine. As a result of the metal structure inspection, most of them were pure iron, ferrite, and also pearlite, cementite and widmannstaten structures were displayed. We could confirm carbonization was formed on the surface of the iron axes-B, iron coffin-nails-B, and iron clamps-A. There was no carbonization in the rest of the artifacts, and it is not certain that whether the carbonized parts were peeled off through extreme corrosion or they were not carbonized when they were made. In the particular part of a blade, the quality of the material was strengthened through processing. Due to the processing re-grain was caused and fine grain particles were formed. As a result of the ICP component analysis, there were no addition atoms because pure irons were used as materials. In the mean time, No. 17 jar-coffin where the iron axes-A are excavated, is chronologically ordered as from the late-fourth century to the mid-fifth century, and No. 1 and No. 2 stone chambers, where the rest of the artifacts were excavated, as the early-sixth century. It was difficult to relate the periodic differences with the manufacture technique artifacts which we inspected because there were no distinct characteristics of the manufacture technique of the metal structures and it is impossible to conclude the artifacts and sites are at the same period although their periods are different.

  • PDF

반자성 물질을 이용한 자기공명영상검사에서의 인공물 감소 (Reduction of Artifacts in Magnetic Resonance Imaging with Diamagnetic Substance)

  • 최우전;김동현
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.581-588
    • /
    • 2019
  • 자기공명영상검사는 조직의 대조도 와 해상력이 우수하지만, 인공물이 발생 될 경우 진단에 영향을 주어 판독이 불가능한 영상을 생성하기도 한다. 치아에 삽입된 금속은 강자성체 또는 상자성체로 되어있는 경우가 대부분이며 자화율 차이로 인하여 기하학적 왜곡을 유발하여 영상진단에 저해되는 경우가 많으며 이를 저감시킬 필요가 있다. 이에 본 연구는 반자성 물질을 사용에 따른 금속 인공물 분석을 실시하고자 한다. 자성 물질로는 치아교정용 와이어와 브라켓인 스테인리스 스틸이 사용되었고 반자성 물질은 구리, 아연, 비스무트를 사용하였다. 검사장비는 1.5T, 3T가 사용되었으며 사용된 시퀀스는 SE, TSE, GE, EPI을 사용하여 측정하였다. 자체 제작된 팬텀을 물질은 균등한 신호를 위하여 아가로스 겔(10%)을 사용하였으며 인공물 유발 물질은 스테인리스 스틸은 팬텀의 정중앙에 위치시켜 검사하고 각 길이 10mm의 정 육면체 반자성 물질의 씌워 검사하였다. 인공물 측정은 Image J를 사용하여 순수한 팬텀 영상에서 자성물질을 포함한 영상을 감산하여 얻은 영상에서 Low Threshold 값을 10으로 설정 한 후 Wand tool을 사용하여 인공물 영역설정 후 면적을 구하였다. 스테인리스 스틸에서 발생한 금속 인공물은 반자성 물질 중 비스무트를 사용한 영상에서 금속 인공물이 가장 많이 감소하였으며 구리와 아연은 약간은 감소하지만, 그 정도의 차이는 크지 않다고 하겠다. 이러한 이유는 비스무트의 반자성 자화율이 가장 작아서 강자성체에서의 자화율을 가장 많이 상쇄하였기 때문이라고 생각된다. 1.5T 와 3T 모두에서 비스무트를 사용한 영상의 인공물이 가장 적게 나왔다. 시퀀스별 인공물 감소는 1.5T에서는 TSE에서 가장 많이 인공물이 감소하였으며 3T에서는 SE에서 가장 많은 인공물이 감소하였다. 따라서 반자성물질의 따른 인공물 변화의 결과는 자화율(${\chi}$)이 가장 낮은 비스무트를 사용한 영상에서 금속인공물이 기준인 Implant 인공물 보다 줄어든 양상을 보여 자화율이 낮은 물질일수록 금속 인공물이 줄어든다는 것을 알 수 있었으며, 기존 금속 인공물의 해결 방법의 단점으로 지적되어온 스캔 시간의 증가 등이 나타나지 않으면서도 인공물을 줄일 수 있는 방법으로 향후 치아 교정 물질뿐만 아니라 치아 보철물 전체에 대한 금속 인공물 저감에 관한 연구의 기초 자료로 사용될 것으로 사료된다.

PET/CT 검사에서 선량변화와 QAC기법 적용 시 Metal Artifact 유무에 따른 SUV 비교분석 (A Comparative Analysis According to a Presence or Absence of Metal Artifacts when a Dose Change and QAC Technique are Applied in PET/CT Tests)

  • 윤선희;김양중;강영직;박수영;김호신;류형기
    • 핵의학기술
    • /
    • 제19권1호
    • /
    • pp.51-56
    • /
    • 2015
  • Purpose As medical radiation exposures on patients are being social issues an interest in a relief of radiation exposures on patients is increasing. Further, there are many cases where some patients among who are getting PET/CT tests choose to get implanted with metal artifacts in their bodies. This study is to find out effects of presence or absence of metal artifacts when dose change or CT attenuation correction for the relief of radiation exposures are applied using phantoms through changes in standard uptake value (SUV). Materials and Methods GE company's Discovery 710 machine was used for PET/CT test equipments. We used NEMA IEC body phantoms. We also used screw and mesh cage made of titanium which are used in real clinical processes for the metal artifacts. Two experiments were conducted: One is to test and measure repeatedly about SUV about differences in CT attenuation corrections according to dose changes and another is to do the same procedure for SUV about the presence and absence of the metal artifacts. We injected $^{18}F-FDG$ into NEMA IEC body phantoms with a TBR ratio of 4:1 and then put the metal material into the transformation phantoms. Once a scanning for the metal artifacts was done we eliminated the metal artifacts and went on non-metal artifacts. For the each two experiments, we scanned repeatedly with CT kVp (140, 120, 100, 80) and mA (120, 80, 40, 20, 10) for an experimental condition. For PET, we reconstructed each with standard AC (STD) technique and quantitation achieved cnsistently QAC) technique among CT attenuation correction methods. We conducted a comparative analysis on measured average values and variations which were measured through repeated measure of SUV of region 1, 2, 3 spheres for each conditions of non-metal /metal scan. Results For each kVp, 120, 80, 40 (mA) of non/metal (screw, mesh cage) showed low frequency of fluctuation rates of above 2%. In 20, 10 mA above 2% of fluctuation rates appeared in high frequency. Also, when we compared the fluctuation rates of STD and QAC techniques in non/metal (screw, mesh cage) tests QAC technique showed about 1-10% of differences for each conditions compared to STD technique. In addition, metal types did not have significant effects on fluctuation rates. Conclusion We confirmed that SUV fluctuation rates for both STD and QAC techniques increase as dosage is lower. We also found that the SUV of PET data was maintained steadily in a low dosage for QAC technique when compared with STD technique. Hence, when the low dosage is used for the relief of radiation exposures on patients QAC technique may be exploited helpfully and this could be applied in the same way for patients with metal artifacts implanted in their bodies.

  • PDF

Manufacturing Techniques and Alloying Compositions of Metal Decorative Artifacts in 18th Century, Myanmar

  • Lee, Jae Sung;Win, Yee Yee;Lee, Bonnie;Yu, Jae Eun
    • 보존과학회지
    • /
    • 제36권4호
    • /
    • pp.296-305
    • /
    • 2020
  • Konbaung Dynasty was the last unified dynasty that ruled Myanmar from 18th to 19th century. During this time Buddhist art flourished in Myanmar due to the interest of the rulers toward their traditional culture. Metal decorative artifacts in the 18th century are classified into structures and Buddha statues. They are further subdivided into gilt-bronze and bronze objects, depending on their material component. Three-dimensional gilt-bronze decorative artifacts were cast with a brass alloy of Cu-Zn-Sn-Pb and their surfaces were gilded with extremely thin gold leaves (less than 1 ㎛ in thickness). The gilded layer approximately comprised 10 wt% silver in addition to the main element, gold. The lack of Hg in the gilded layer, indicated that the amalgam gilding technique was not applied. The analysis results indicated that the lacquered gilding technique was applied to the objects. Bronze decorative artifacts without gilding were cast with materials containing Cu-Sn-Pb. The bronze pavilions and bronze Buddha staues were crafted using the same alloy of high-tin bronze, which approximately contained 20 wt% Sn. No heat treatment was applied to reduce the brittleness of the objects after they were cast with a large amount of Sn. The most significant difference between the gilt-bronze and bronze decorative artifacts lie in their elemental compositions. The gilt-bronze decorative artifacts with their gilded surface were manufactured using brass containing zinc, while the unplated bronze decorative artifacts were composed of bronze containing tin. Artifacts of the same type and size are classified differently depending on the materials utilized in the surface treatment such as gilding.

Metal Area Segmentation in X-ray CT Images Using the RNA (Relevant Neighbor Ar ea) Principle

  • Kim, Youngshin;Kwon, Hyukjoon;Kim, Joongkyu;Yi, Juneho
    • 한국멀티미디어학회논문지
    • /
    • 제15권12호
    • /
    • pp.1442-1448
    • /
    • 2012
  • The problem of Metal Area Segmentation (MAS) in X-ray CT images is a very hard task because of metal artifacts. This research features a practical yet effective method for MAS in X-ray CT images that exploits both projection image and reconstructed image spaces. We employ the Relevant Neighbor Area (RNA) idea [1] originally developed for projection image inpainting in order to create a novel feature in the projection image space that distinctively represents metal and near-metal pixels with opposite signs. In the reconstructed result of the feature image, application of a simple thresholding technique provides accurate segmentation of metal areas due to nice separation of near-metal areas from metal areas in its histogram.

Magnitude of beam-hardening artifacts produced by gutta-percha and metal posts on cone-beam computed tomography with varying tube current

  • Gaeta-Araujo, Hugo;Nascimento, Eduarda Helena Leandro;Fontenele, Rocharles Cavalcante;Mancini, Arthur Xavier Maseti;Freitas, Deborah Queiroz;Oliveira-Santos, Christiano
    • Imaging Science in Dentistry
    • /
    • 제50권1호
    • /
    • pp.1-7
    • /
    • 2020
  • Purpose: This study was performed to evaluate the magnitude of artifacts produced by gutta-percha and metal posts on cone-beam computed tomography (CBCT) scans obtained with different tube currents and with or without metal artifact reduction (MAR). Materials and Methods: A tooth was inserted in a dry human mandible socket, and CBCT scans were acquired after root canal instrumentation, root canal filling, and metal post placement with various tube currents with and without MAR activation. The artifact magnitude was assessed by the standard deviation (SD) of gray values and the contrast-to-noise ratio (CNR) at the various distances from the tooth. Data were compared using multi-way analysis of variance. Results: At all distances, a current of 4 mA was associated with a higher SD and a lower CNR than 8 mA or 10 mA (P<0.05). For the metal posts without MAR, the artifact magnitude as assessed by SD was greatest at 1.5 cm or less (P<0.05). When MAR was applied, SD values for distances 1.5 cm or closer to the tooth were reduced (P<0.05). MAR usage did not influence the magnitude of artifacts in the control and gutta-percha groups(P>0.05). Conclusion: Increasing the tube current from 4 mA to 8 mA may reduce the magnitude of artifacts from metal posts. The magnitude of artifacts arising from metal posts was significantly higher at distances of 1.5 cm or less than at greater distances. MAR usage improved image quality near the metal post, but had no significant influence farther than 1.5 cm from the tooth.

미세구조 관찰에 의한 철제금속유물의 특성화 (Characterization of Ferrous Metal Artifacts by Microstructure Observation)

  • 허우영;이철
    • 분석과학
    • /
    • 제11권4호
    • /
    • pp.316-320
    • /
    • 1998
  • An image analysis was used for the interpretation of microstructures of ferrous metal artifacts. For the purposes, various microstructural features such as average grain size, phase area, shape factor, and composition of the inclusions, were parameterized for the information about manufacturing techniques such as casting, heating and tempering. The carbon content was determined through the evaluation of the amount of pearlite phase. As the amount of pearlite phase increased the shape factor also increased. Grain size was relatively smaller in trans-section than in cross-section. The manufacturing direction was trans-sectional because the orientation of inclusions was elongated lengthwise. All inclusions was of silicate groups and the manufacturing temperature was estimated up to $1450^{\circ}C$.

  • PDF