• Title/Summary/Keyword: Metal Filter

Search Result 347, Processing Time 0.029 seconds

A Study on the Status of Fine Dust Generated from Construction Waste Intermediate Treatment Plants in Rural Area and Its Impact on Neighboring Areas (농촌지역 건설폐기물 중간처리 사업장에서 발생하는 미세먼지의 발생 현황 및 인근 지역에 미치는 영향 연구)

  • Jang, Kyong-Pil;Park, Ji-Sun;Kim, Byung-Yun
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.25 no.4
    • /
    • pp.9-16
    • /
    • 2023
  • In this study, the status and characteristics of fine dust and its impact on neighboring areas were investigated to proactively respond to the government's environmental regulations expected in the future and to minimize the damage by the fine dust generated at construction waste intermediate treatment plants. In addition, since there are no such plants that can affect the surroundings with no houses or other waste treatment sites nearby, an independently located construction waste intermediate treatment plant was selected to compare the characteristics of fine dust with that from the construction waste intermediate treatment sites located in the downtown area. The conclusions of the study are as follows. (1) The measurement results of PM10 at 4 points in the plant showed that the location where the crushing facility was operating had an elevated level of fine dust at 80㎍/m3 on average and a maximum of 124㎍/m3, and the level rose to 110㎍/m3 at points where vehicles frequent. (2) The PM2.5 measurement results inside the plant showed that the average concentration of the reference point was 16㎍/m3 and the maximum value was 20㎍/m3, which was distributed within the management standard. (3) It was found that the average concentration of PM10 in the nearby area ranged from 28 to 38㎍/m3, which was similar to or lower than 36㎍/m3 of the reference point. Therefore, the concentration of the fine dust generated in the plant had a negligible effect on the increase in concentration of fine dust in nearby areas. (4) The heavy metal contents were measured from the filter paper collected from the plant. The PM10 was found to be about 14 to 26ng/m3, and PM 2.5 was 25 to 28ng/m3, which was the average of domestic atmospheric concentrations. (5) The SEM-EDX analysis results showed that the PM10 contained Si and O around 40% similarly for both. The SiO2, a component of silica occupied the most and C was present as CaCO3, which was assumed to be a limestone component. The remaining components included NaO, Al2O3, and CaO as trace oxides. (6) The SEM-EDX analysis results showed that the PM 2.5 contained 5 to 7% of Cl, which is a chlorine ion, and a small amount of K was detected at 2.51% in the sample from the shutdown plant.

Deep vein thrombosis caused by malignant afferent loop obstruction

  • Kang, Eun Gyu;Kim, Chan;Lee, Jeungeun;Cha, Min-uk;Kim, Joo Hoon;Park, Seo-Hwa;Kim, Man Deuk;Lee, Do Yun;Rha, Sun Young
    • Journal of Yeungnam Medical Science
    • /
    • v.33 no.2
    • /
    • pp.166-169
    • /
    • 2016
  • Afferent loop obstruction following gastrectomy is a rare but fatal complication. Clinical features of afferent loop obstruction are mainly gastrointestinal symptoms. A 56-year-old female underwent radical total gastrectomy with Roux-en-Y esophagojejunostomy for treatment of advanced gastric cancer. After fourteen months postoperatively, she showed gradual development of edema of both legs. Computed tomography (CT) scan showed disease progression at the jejunojejunostomy site and consequent dilated afferent loop, which resulted in inferior vena cava (IVC) compression. A drainage catheter was placed percutaneously into the afferent loop through the intrahepatic duct and an IVC filter was placed at the suprarenal IVC, and self-expanding metal stents were inserted into bilateral common iliac veins. With these procedures, sympotms related with afferent loop obstruction and deep vein thrombosis were improved dramatically. The follow-up abdominal CT scan was taken 3 weeks later and revealed the completely decompressed afferent loop and improved IVC patency. Surgical treatment should be considered as the first choice for afferent loop obstruction; however, because it is more immediate and less invasive, non-surgical modalities, such as percutaneous catheter drainage or stent placement, can be effective alternatives for inoperable cases or risky patients who have severe medical comorbidities.

Source Identification of Ambient PM-10 Using the PMF Model (PMF 모델을 이용한 대기 중 PM-10 오염원의 확인)

  • 황인조;김동술
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.6
    • /
    • pp.701-717
    • /
    • 2003
  • The objective of this study was to extensively estimate the air quality trends of the study area by surveying con-centration trends in months or seasons, after analyzing the mass concentration of PM-10 samples and the inorganic lements, ion, and total carbon in PM-10. Also, the study introduced to apply the PMF (Positive Matrix Factoriza-tion) model that is useful when absence of the source profile. Thus the model was thought to be suitable in Korea that often has few information about pollution sources. After obtaining results from the PMF modeling, the existing sources at the study area were qualitatively identified The PM-10 particles collected on quartz fiber filters by a PM-10 high-vol air sampler for 3 years (Mar. 1999∼Dec.2001) in Kyung Hee University. The 25 chemical species (Al, Mn, Ti, V, Cr, Fe, Ni, Cu, Zn, As, Se, Cd, Ba, Ce, Pb, Si, N $a^{#}$, N $H_4$$^{+}$, $K^{+}$, $Mg^{2+}$, $Ca^{2+}$, C $l^{[-10]}$ , N $O_3$$^{[-10]}$ , S $O_4$$^{2-}$, TC) were analyzed by ICP-AES, IC, and EA after executing proper pre - treatments of each sample filter. The PMF model was intensively applied to estimate the quantitative contribution of air pollution sources based on the chemical information (128 samples and 25 chemical species). Through a case study of the PMF modeling for the PM-10 aerosols. the total of 11 factors were determined. The multiple linear regression analysis between the observed PM-10 mass concentration and the estimated G matrix had been performed following the FPEAK test. Finally the regression analysis provided source profiles (scaled F matrix). So, 11 sources were qualitatively identified, such as secondary aerosol related source, soil related source, waste incineration source, field burning source, fossil fuel combustion source, industry related source, motor vehicle source, oil/coal combustion source, non-ferrous metal source, and aged sea- salt source, respectively.ively.y.

A Study on Filtration Efficiency of Several Dust Masks for Stainless Steel arc Welding fume (방진마스크의 Stainless steel arc 용접흄 여과효율에 관한 연구)

  • Song, Kyung-Seuk;Kwon, Yong-Shick;Han, Kuy-Tae;Chung, Kyu-Hyuck;Lee, Yong-Mook;Yu, Il-Je
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.1
    • /
    • pp.42-47
    • /
    • 2001
  • The purpose of this study was to investigate for filtration efficiency of several dust masks, comparing with filtration efficiency certified by KOSHA(Korea Occupational Safety & Health Agency), and to require of the right use of protective respirators. Using a welding fume generator and chamber, several dust masks, which were widely used in the workplaces in korea, were tested for their filtering efficiency for stainless steel arc welding fume. The filtration efficiency testing system consisted of a welding fume generator, a chamber and a filtration unit. The filtration unit was made of a mask which was inserted into the sampling cassette and another sampling cassette, which contained mixed cellulose ester filter paper. These two cassettes were connected with tubing. Stainless steel arc welding fume generator was delivered into an chamber. The welding fume in the chamber was passed into the filtration unit with flow rate of 30 liter/min. The welding fume filtration efficiency was evaluated by gravimetric measurement. Metal concentrations in the welding fume before and after filtration were measured with inductive coupling plasma analyzer. Following results were obtained: Filtration efficiency of welding fume for common hygienic mask was 63.82% and the average efficiencies for A, B, C, D, E, F and G masks were 94.62%, 96.58%, 83.20%, 82.76%, 77.25%, 86.55% and 93.22%, respectively. Our results indicate that dust masks used widely in the welding workplaces in korea are not proper for protecting worker's health and then the use of fume mask should be required.

  • PDF

The Extraction of Metal Contaminants using Supercritical CO2 (초임계이산화탄소를 이용한 방사성 금속이온 추출)

  • Ju, Minsu;Kim, Jung-Hoon;Kang, Se-Sik
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.5
    • /
    • pp.660-667
    • /
    • 2016
  • Conventional decontamination methods utilize water-based systems, which generate high amounts of secondary wastes. Herein, we describe an environmentally benign decontamination method using liquid and supercritical $CO_2$. The use of $CO_2$ as a solvent affords effective waste reduction by its ability to be recycled, thereby leaving be hind only the contaminants upon its evaporation. In this study, a $CO_2$ solution process was assessed using t-salen(t-butylsalen), DC18C6 (dicyclohexano-18Crown6), 8-HQN(8-hydroxyquinoline), NEt4PFOSA(perfluoro-1-octanesulfonic acid tetra-ethyl ammonium salt), and NEt4PFOA(pentadecafluorooctanoic acid ammonium salt) to extract spiked radioactive contaminants(Nb,Zr,Co,Sr) from an inert sample matrix, namely filter paper. With the static extraction method, Sr was extracted with a maximum extraction rate of 97%, and Nb was extracted with a maximum extraction rate of 75%. Additionally, we were also able to extract Co and Zr with maximum extract ion ratesof 73% and 64%, respectively.

Cone-beam Reconstruction using Limited EPID Projections for Seeds Localization (Seed의 위치 확인을 위한 제한된 EPID 영상을 이용한 콘빔 재구성)

  • Chang, Ji-Na;Jung, Won-Kyun;Park, Sung-Ho;Cheong, Kwang-Ho;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.19 no.3
    • /
    • pp.186-190
    • /
    • 2008
  • In this study, we describe the preliminary application for the delineation of a metal object using cone-beam reconstruction (CBR) based on limited electronic portal imaging device (EPID) projections. A typical Feldkamp, Davis and Kress (FDK) reconstruction algorithm accompanying the edge preserving smoothing filter was used as only a few projections are acquired for reconstruction. In a correlation study of the projection numbers, we found that the size of the seeds and their location depicted by these CBR images were almost identical. Limited views were used for CBR, and our method is inexpensive and competitive for use in clinical applications.

  • PDF

Chemical characteristics of ions and trace metallic element of PM2.5 in Busan metropolitan area (부산지역 $PM_{2.5}$의 이온 및 미량 금속성분의 화학적 특성)

  • 전보경;서정민;최금찬
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.4
    • /
    • pp.63-71
    • /
    • 2001
  • PM 2.5/ samples were measured at two sites, Hadan(suburban site) and Anrak (roadside site) in Busan area. PM 2.5/ sampling was performed for 24-hour intervals by the FH9.5 particulate sampler. Aerosol samples were collected on PTFE filter. A total of 60 particulate samples were collected, dad samples were measured for Particulate mass concentration, metallic elements (Cr, Mn, Ni. Cu. Se, Fe, Pb, and Zn) and waer-soluble elements (C $l^{[-10]}$ , N $O_{3}$$^{[-10]}$ ,S $O_{4}$$^{2-}$, N $H_{4}$$^{+}$, $Ca_{2}$$^{+}$, $Mg_{2}$$^{+}$ and $^{+}$.Mass concentration in Hadan ranged 24.23~57.12 $\mu\textrm{g}$/㎥ and 60.22~72.12 $\mu\textrm{g}$/㎥m Yellow Sand Events. Major cations in Hadan and Anrak site is N $H_{4}$$^{+}$and N $a^{+}$ respectively. SO42$^{[-10]}$ was the abundant specie in the PM 2.5 fraction for Hadan site an dAnrak site. Hadan site showed igher concentration in S $O_{4}$$^{2.1}$ and N $H_{4}$ $^{+}$ In Anrak site the concentration of S $O_{4}$/sip 2-/and N $a^{+}$ was higher than other ions Prominent metallic elements were Fe and Pb in two sites. Principal component analysis showed that main source of PM 2.5 aerosol particles was non-metal related source which was resulted in relating elements as Cr, Ni, and Pb at Hadan site, Anrak site also has resulted PM2.5 aerosol paricles source, which was related its element like Zn, and Ni,. The SAS package analysis also showed that long-range transport effect at Hadan area due to Yellow Sand Event by the prevailing weaterlies.ling weaterlies.

  • PDF

Nano-Sized Mullite(3Al2O3.42SiO2) Colloids Fabricated by Spray Combustion Synthesis (SCS) Technique (분무연소합성(SCS)법에 의한 나노크기 물라이트(3Al2O3.42SiO2) 콜로이드 제조)

  • Lee, Sang-Jin;Jun, Byung-Sei
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.4
    • /
    • pp.297-301
    • /
    • 2004
  • Nano-sized mullite (3Al$_2$O$_3$$.$2SiO$_2$) colloids were prepared by use of the spray combustion method. For combustion reaction, Al(NO$_3$)$_3$$.$9$H_2O$, and CH$_{6}$N$_4$O were used as an oxidizer and a fuel respectively, and then colloidal silica was also added as 2SiO$_2$source for mullite. The temperature of the reaction chamber was kept at 80$0^{\circ}C$ to initiate the ignition of droplets of the mixed precursors. For preventing droplet coagulation, the droplet number concentration was reduced using the metal screen filter, and the residence time of aerosol was kept at 2.5 seconds for laminar flow. The synthesized colloidal particles had an uniform spherical shape with 130 nanometer size and the crystalline phase showed the mullite with stoichiometry in the observations of XRD and TEM.

A CMOS Intermediate-Frequency Transceiver IC for Wireless Local Loop (무선가입자망용 CMOS 중간주파수처리 집적회로)

  • 김종문;이재헌;송호준
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.8A
    • /
    • pp.1252-1258
    • /
    • 1999
  • This paper describes a COMS IF transceiver IC for 10-MHz bandwidth wireless local loops. It interfaces between the RF section and the digital MODEM section and performs the IF-to-baseband (Rx) and baseband-to-IF (Tx) frequency conversions. The chip incorporates variable gain amplifiers, phase-locked loops, low pass filters, analog-to-digital and digital-to-analog converters. It has been implemented in a 0.6 -${\mu}{\textrm}{m}$ 2-poly 3-metal CMOS process. The phase-locked loops include voltage-controlled oscillators, dividers, phase detectors, and charge pumps on chip. The only external complonents are the filter and the varactor-tuned LC tank circuit. The chip size is 4 mm $\times$ 4 mm and the total supply current is about 57 mA at 3.3 V.

  • PDF

Development of recognition system of a slab number in the steel production line (철강공정 슬라브번호 자동인식 시스템 개발)

  • 이종학;박상국;이문락
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.986-989
    • /
    • 2003
  • In the steel production line, the molten metal of a furnace is transformed into slab material and then move to the hot strip line, This paper describe about the real time recognition system of material management number, which is marked at the surface of a slab in the steel production line. This recognition processing should be performed before the slab is moved to the hot strip line. This system include following recognition steps. First, we remove noise from the captured slab image by use pre-filter. Second, we extract rough area, which is include slab number and then, we extract individual number area. Finally, we recognize material management number by use KLT(Karhunen-Loeve transform) algorithm. We applied our system to the real slave image, which was captured in the process line. In the results, we recognized slave number to the 94% accuracy.

  • PDF