• 제목/요약/키워드: Metal Connectors

검색결과 28건 처리시간 0.017초

New metal connectors developed to improve the shear strength of stone masonry walls

  • Karabork, Turan;Kocak, Yilmaz
    • Structural Engineering and Mechanics
    • /
    • 제50권1호
    • /
    • pp.121-135
    • /
    • 2014
  • Stone masonry structures are widely used around the world, but they deteriorate easily, due to low shear strength capacity. Many techniques have been developed to increase the shear strength of stone masonry constructions. The aim of this experimental study was to investigate the performance of stone masonry walls strengthened by metal connectors as an alternative shear reinforcement technique. For this purpose, three new metal connector (clamp) types were developed. The shear strength of the walls was improved by applying these clamps to stone masonry walls. Ten stone masonry walls were structurally tested in diagonal compression. Various parameters regarding the in-plane behavior of strengthening stone masonry walls, including shear strength, failure modes, maximum drift, ductility, and shear modulus, were investigated. Experimentally obtained shear strengths were confirmed by empirical equations. The results of the study suggest that the new clamps developed for the study effectively increased the levels of shear strength and ductility of masonry constructions.

3D FE modeling considering shear connectors representation and number in CBGB

  • Abbu, Muthanna A.;Ekmekyapar, Talha A.;Ozakca, Mustafa A.
    • Steel and Composite Structures
    • /
    • 제17권3호
    • /
    • pp.237-252
    • /
    • 2014
  • The use of composite structures is increasingly present in civil building works. Composite Box Girder Bridges (CBGB), particularly, are study of effect of shear connector's numbers and distribution on the behavior of CBGBs is submitted. A Predicti structures consisting of two materials, both connected by metal devices known as shear connectors. The main functions of these connectors are to allow for the joint behavior of the girder-deck, to restrict longitudinal slipping and uplifting at the element's interface and to take shear forces. This paper presents 3D numerical models of CBGBs to simulate their actual structural behavior, with emphasis on the girder-deck interface. Additionally, a Prediction of several FE models is assessed against the results acquired from a field test. A number of factors are considered, and confirmed through experiments, especially full shear connections, which are obviously essential in composite box girder. A good representation for shear connectors by suitable element type is considered. Numerical predictions of vertical displacements at critical sections fit fairly well with those evaluated experimentally. The agreement between the FE models and the experimental models show that the FE model can aid engineers in design practices of box girder bridges. Preliminary results indicate that number of shear studs can be significantly reduced to facilitate adoption of a new arrangement in modeling CBGBs with full composition. However, a further feasibility study to investigate the practical and economic aspects of such a remedy is recommended, and it may represent partial composition in such modeling.

Analysis and design of metal-plate-connected joints subjected to buckling loads

  • Hussein, R.
    • Structural Engineering and Mechanics
    • /
    • 제9권5호
    • /
    • pp.417-432
    • /
    • 2000
  • A comprehensive analytic study has been conducted to investigate the instability problems of metal-plate-connected (MPC) joints in light frame trusses. The primary objective in this study is to determine the governing factors that constitute the buckling of the metal connectors and their effects on the structural response of joints. Another objective is to recommend design curves for the daily structural design of these joints. The numeric data presented in this paper has emerged from a broad base that was founded on over 350 advanced computer simulations, and was supported by available experimental results obtained by others. This basic-to-applied research includes practical engineering parameters such as size of gaps, shear lengths, gauge (plate thickness) of connectors, size of un-braced areas, failure modes, and progressive disintegration of joints. Square-end members have been emphasized though the results cover the custom-made fitted joints. The results indicate that chord shears cause and dominate the buckling of MPC joints, and the shear length has a more pronounced effect than the size of gaps. Further, large gauges and small un-braced areas improve the buckling response. Several practical recommendations have been suggested throughout the paper such as keeping the ratio of gap/shear length below 3/4 for improving the buckling strength. The study reveals that multi-area joints should not be simplified as single web-to-chord MPC joints such as keeping the ratio of gap/shear length below 3/4 for improving the buckling strength, even where one web is in tension and the other in compression. Finally, the results obtained from this study favorably agree with experimental data by others, and the classic buckling theories for other structural components.

파이프골조 온실의 조립연결구 내력에 관한 실험적 연구 (Experimental Analysis on Yield Strength of Pipe Connectors and Joints for Pipe Framed Greenhouses)

  • 남상운;김문기;권혁진
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.271-274
    • /
    • 2001
  • Experiments on the yield strength of pipe connectors made of metal wire, joint pins, pole pipes, multi span insertion joints, and T-clamp joints used in pipe houses were conducted. The strength of connections of a pipe connector made of metal wire was adequate but it had a big difference according to loading direction. The collapse load of pipes connected with a joint pin was lower than that of single pipes. Also experimental results showed that pole pipes for use in a part of frame buried under the ground were safe, and the strength of multi span insertion joints should be increased. The resistant moment of T-clamp was about 13.7% of a single pipe.

  • PDF

구치부 고정성 국소의치에서 전부도재 시스템에 따른 응력분포에 관한 연구 (A STUDY ON THE STRESS DISTRIBUTION OF POSTERIOR FIXED PARTIAL DENTURE WITH VARIOUS ALL-CERAMIC SYSTEMS)

  • 강한중;동진근;오상천;이해형;송기창
    • 대한치과보철학회지
    • /
    • 제43권2호
    • /
    • pp.204-217
    • /
    • 2005
  • Purpose. The purpose of this study was to analyze stress distribution of all ceramic posterior fixed partial denture using a three dimensional finite element method. Material and method. A three dimensional finite element model was created to demonstrate all-ceramic posterior fixed partial denture and then this computer model measured the stress distribution of the all ceramic bridges which has a ceramic core materials such as Zirconia, IPS Empress. 2. In-Ceram zirconia, Metal-Ceramic. Also the stress distribution was examined according to loading sites when force was applied to sites such as the central area of second premolar the mesial connector of pontic, the central fossa of pontic, the distal connector of pontic, and the central fossa of second molar. Results. 1. In all the materials of the core in this study, von Mises stress indicated that the stress increased as force was applied to loaded sites, just at those points, on the connector, and the margin in the area adjacent to the connectors. 2. The maximum principal stress was much higher in the lower part of the connectors than in any other region. 3. As the load was applied to the different locations, the research showed a consistent increase of stress in the lower connectors. The maximum value of the von Mises stress was two or three times greater when the load was applied directly to the connectors rather than indirectly through another stressed region. 4. In the case of In-Ceram zirconia, the stress in lower connectors was the highest of all the reference points, the stress showed 75% of all the maximum stress. Ziconia showed 72%, Metal Ceramic 67% and IPS Empress 2 50%. 5. In the case of Ziconia, the stress was well dispersed in each reference point that the stress differences were smaller when compared to In-Cream ziconia.

파이프 골조 온실의 조립 연결구 내력 시험 (Experimental Analysis on Yield Strength of Pipe Connectors and Joints for Pipe Framed Greenhouses)

  • 남상운
    • 한국농공학회지
    • /
    • 제43권6호
    • /
    • pp.113-119
    • /
    • 2001
  • Experiments on the yield strength of pipe connectors made of metal wire, joint pins, pole pipes, multi span insertion joints, and T-clamp joints used in pipe houses were conducted. The strength of connections of a pipe connector made of metal wire was adequate but it had a big difference according to loading direction. Therefore as it is installed, its direction should be taken into consideration. The collapse load of pipes connected with a joint pin was lower than that of single pipes. In the part of frame member at which the great bending moment occurs, the use of joint pin should be avoided. Also experimental results showed that pole pipes for use in a part of frame buried under the ground were safe, and the strength of multi span insertion joints should be increased. The resistant moment of T-clamp was about 13.7% of a single pipe. In case that the external forces acting on left and right rafter are different. a unsymmetrical rotational force is produced at the multi span joint. If it is expected that the actual bending moment on the multi span joint is larger than resistant moment of T-clamp, a reinforcement to safely resist the rotational force is required.

  • PDF

휴대폰용 금속 프론트 케이스의 프레스 성형공정에서 프레임의 형상오차 저감을 위한 연결부 형상설계 (Connector Design in Press Forming Process to Prevent Frame Twisting of Metal Front Case for Mobile Phone)

  • 이인규;이찬주;손영기;이정민;김동환;김병민
    • 소성∙가공
    • /
    • 제20권2호
    • /
    • pp.104-109
    • /
    • 2011
  • The metal front case of a mobile phone is manufactured by press forming and welding of thin metal sheets. Twisting of the frame after the forming process is one of main obstacle for the assembly with reinforcement by welding. This study introduces a method preventing twisting of the metal front case frame in press forming. The spring-back after forming produces twisting of the frame, which leads to a low structural stiffness. To reduce twisting, connectors are required to reinforce the structural stiffness of the frame. In this study, the twisting profile is evaluated using a finite element(FE) analysis for various connector shapes. The actual connector shape is determined by minimization of the frame twisting within the tolerance of the FE-analysis. To verify the validity of the proposed blank shape, a forming experiment is performed and the twisting profile is measured using a 3D laser scanning method. The dimensional accuracy is found to be within the tolerance and in good agreement with the FE-analysis.

C5210-H(HP)와 NKT322-EH 소재의 협피치 커텍터에서 단조 가공에 의한 소재 폭 변화에 관한 연구 (A study on the change of material width by forging processing in fine pitch connector of C5210-H(HP) and NKT322-EH materials)

  • 신미경;이춘규
    • Design & Manufacturing
    • /
    • 제14권3호
    • /
    • pp.17-22
    • /
    • 2020
  • As devices such as smartphones, tablet PC, and wearable devices have been miniaturized, the connectors that go into the devices are also designed to be very small. The connector combines the plug and the receptacle to transfer electricity. As devices are miniaturized, the contact shape is formed by partially thinning the thickness of the raw material of the terminal in order to lower the coupling height of the plug and receptacle. The product used in this study is a receptacle terminal used for 0.4mm pitch board to board connector among fine pitch connectors. When the material thickness is reduced by forging the receptacle terminal, the width change of the pin is checked. To reduce the thickness of the material by forging, pre-notching is applied in the first step, forging in the second step, and notching in the third step. After forming the width dimension of the pin to 0.28 mm in the pre-notching process, in the forging process, the material thickness 0.08 mm and 0.02 mm (25%) were forged and the thickness was changed to 0.06 mm and the width change amount of the pin was measured. The facility produced 10,000 pieces at 400 SPM using a Yamada Dobby (MXM-40L) press, and thirty pins were measured and the average value was shown. After forging by using C5210-H (HP) and NKT322-EH, which are frequently used in connectors, analyze the amount of change in each material. The effect of punching oil on forging is investigated by appling FM-200M, which is highly viscous, and FL-212, fast drying oil. This study aims to minimize mold modification by predicting the amount of material change after forging.

Fatigue behavior of stud shear connectors in steel and recycled tyre rubber-filled concrete composite beams

  • Han, Qing-Hua;Wang, Yi-Hong;Xu, Jie;Xing, Ying
    • Steel and Composite Structures
    • /
    • 제22권2호
    • /
    • pp.353-368
    • /
    • 2016
  • This paper extends our recent work on the fatigue behavior of stud shear connectors in steel and recycled tyre rubber-filled concrete (RRFC) composite beams. A series of 16 fatigue push-out tests were conducted using a hydraulic servo testing machine. Three different recycled tyre rubber contents of concrete, 0%, 5% and 10%, were adopted as main variable parameters. Stress amplitudes and the diameters of studs were also taken into consideration in the tests. The results show that the fatigue lives of studs in 5% and 10% RRFC were 1.6 and 2.0 times greater of those in normal concrete, respectively. At the same time, the ultimate residual slips' values of stud increased in RRFC to highlight its better ductility. The average ultimate residual slip value of the studs was found to be equal to a quarter of studs' diameter. It had also been proved that stress amplitude was inversely proportional to the fatigue life of studs. Moreover, the fatigue lives of studs with large diameter were slightly shorter than those of smaller ones and using larger ones had the risk of tearing off the base metal. Finally, the comparison between test results and three national codes was discussed.

GFRP 보강적층판 및 GFRP rod를 이용한 낙엽송 집성재 접합부의 모멘트저항 성능평가 (Moment Resistance Performance Evaluation of Larch Glulam Joints using GFRP-reinforced Laminated Plate and GFRP Rod)

  • 정홍주;송요진;이인환;홍순일
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권1호
    • /
    • pp.40-47
    • /
    • 2016
  • 구조용 집성재 라멘 접합부에 일반적으로 사용되는 접합철물을 대신하여 단판과 GFRP (Glass Fiber Reinforced Plastic)를 복합시킨 GFRP 보강적층판과 삽입 접착형 GFRP rod를 접합물로 사용하였다. 이들을 적용시킨 접합부에 대한 모멘트저항 성능평가 결과, 접합철물을 이용한 실험체(Type-1)와 비교하여 GFRP 보강적층판과 GFRP rod 핀을 사용한 실험체의 항복모멘트는 4% 낮게 측정되었으나 회전강성은 29% 높게 측정되었다. 또한 GFRP 보강적층판과 목재(Eucalyptus marginata)핀을 사용한 실험체는 Type-1 실험체와 비교하여 항복모멘트 11%, 회전강성 56% 높게 측정되며 가장 양호한 성능을 나타냈었다. 파괴형상과 완전탄소성 분석을 통해서도 핀에 의한 전단내력으로부터의 취성파괴가 아닌 연성거동을 나타내며, 접합내력이 상승하고 부재의 일체화가 이루어짐을 확인하였다. 반면, GFRP rod를 삽입 접착한 실험체는 접착 불량으로 측정이 불가하거나 접합성능이 매우 낮게 측정되었다.