• 제목/요약/키워드: Metal Artifact

검색결과 106건 처리시간 0.022초

CNC 공작기계의 열변형 오차 보정 (I) - 보정장치 기초실험 - (Compensation of Thermal Error for the CNC Machine Tools (I) - The Basic Experiment of Compensation Device -)

  • 이재종;최대봉;곽성조;박현구
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 춘계학술대회 논문집(한국공작기계학회)
    • /
    • pp.453-457
    • /
    • 2001
  • One of the major limitations of productivity and quality in metal cutting is the machining accuracy of machine tools. The machining accuracy is affected by geometric and thermal errors of the machine tools. In this study, the compensation device is manufactured in order to compensate thermal error of machine tools under the real-time. This paper models of the thermal errors for error analysis and develops on-the-machine measurement system by which the volumetric error are measured and compensated. The thermal error is modeled by means of angularity errors of a column and thermal drift error of the spindle unit which are measured by the touch probe unit with a star type styluses, a designed spherical ball artifact, and five gap sensors. In order to compensate thermal characteristics under several operating conditions, experiments performed with five gap sensors and manufactured compensation device on the horizontal machining center.

  • PDF

작업조건에 따른 공작기계의 열변형 특성 해석 (Characteristics Analysis of Thermal Deformation for Machine Tools with respect to Operating Conditions)

  • 이재종;최대봉;박현구;곽성조;박홍석
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2000년도 추계학술대회논문집 - 한국공작기계학회
    • /
    • pp.449-453
    • /
    • 2000
  • In metal cutting, the machining accuracy is more affected by thermal errors than by geometric errors. This paper models of the thermal errors for error analysis and develops on-the-machine measurement system by which the volumetric error are measured and compensated. The thermal error is modeled by means of angularity errors of a column and thermal drift error of the spindle unit which are measured by the touch probe unit with a star type styluses, a designed spherical ball artifact, and five gap sensors. In order to analyze the thermal characteristics under several operating conditions, experiments performed with the touch probe unit and five gap sensors on the vertical and horizontal machining centers.

  • PDF

CT 영상에서 치아 상하악 분리 (Teeth Separation in CT Images)

  • 채정엽;이철희
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2018년도 춘계학술발표대회
    • /
    • pp.462-464
    • /
    • 2018
  • 본 논문은 촬영된 치아의 CT영상에서 치아의 상악과 하악의 분리 알고리즘을 제안한다. 촬영 기기의 노후화, metal artifact, 치아 부정합 등 외부 요인에도 강인한 성능을 보이도록 알고리즘을 설계하였다.

치아 임플란트와 보철에서 발생하는 자기공명영상의 인공물 감소방안 연구 (A Study on the Artifact Reduction Method of Magnetic Resonance Imaging in Dental Implants and Prostheses)

  • 신운재
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.1025-1033
    • /
    • 2019
  • 뇌 질환과 두경부 검사에서 전산화단층촬영의 선속 경화현상이 없는 자기공명영상이 조직의 높은 대조도와 우수한 분해능의 영상을 획득하는 검사 방법으로 인식되고 있지만 구강 내 금속 이식물이 있는 경우는 자화율 인공물(magnetic susceptibility artifact)이 발생되어 영상 진단에 장해 요소가 된다. 따라서 본 연구는 자기공명영상에서 치아 임플란트와 보철에 의한 인공물 감소 방안을 강구하고자 한다. 자기공명영상에서 임플란트에 의한 인공물 발생은 GE 기법에서 TE가 짧을수록 신호 크기가 증가하였고, 물의 온도 변화에서는 일관성이 없게 나타났다. SE 기법에서도 공기보다 물의 신호 크기가 전반적으로 높았지만, 신호대 잡음비는 공기와 온도에 의한 차이가 없었다. EPI 기법에서는 공기보다 물이 있을 때 정량적, 정성적으로 인공물이 적게 발생한 영상을 얻을 수 있었고, 특히 물 온도 20°와 30°에서 신호 대 잡음비가 가장 높게 측정되었다. 결론적으로 EPI 기법에서 물 온도 20°와 30°의 물주머니를 이용하여 뇌 확산강조영상을 획득하면 임플란트와 보철물에 의한 자화율인공물이 감소되어 보다 진단적 가치가 있는 영상을 획득할 수 있을 것으로 사료된다.

Conservation of the Lacquer Artifacts Excavated from Suchon-ri, Gongju, Korea

  • Song, Ji Ae;Jeong, Ah-reum;Kwon, Hyeok-nam;Han, Woo-rim;Lee, Hyun-sang
    • 보존과학회지
    • /
    • 제34권6호
    • /
    • pp.549-556
    • /
    • 2018
  • In November 2011, various artifacts were excavated from the No. 8 stone-lined tomb in Suchon-ri, Gongju by the Chungnam Institute of History and Culture. These included artifacts with lacquered mainframe and silvery metal ornament. These were recovered together with soil and underwent conservation treatment. In this paper, we discuss the scientific analysis and conservation treatment of the lacquered artifacts excavated from the Suchon-ri site. Among our findings is that the artifacts have three layers of lacquer coating and the metal parts are primarily composed of Ag. As the artifacts were recovered with soil from the site, the soil was removed from underneath and inside the artifacts. The inside of the lacquerware was reinforced with rayon paper using 3% funori, and the metal was treated with acrylic resin after removing the acrylic resin previously used to recover the artifact, followed by cleaning. The metal was also internally reinforced with gauze. Finally, the interior reinforcement was made using PVA and resin in pulp and attached with funori to preserve the shape of the lacquerware, and the exposed rayon was finished with acrylic paint. The main advantages of this study are its review of conservation treatment strategies for lacquer artifacts whose numbers have recently increased, and the application of new conservation treatment methods.

Does the metal artifact reduction algorithm activation mode influence the magnitude of artifacts in CBCT images?

  • Fontenele, Rocharles C.;Nascimento, Eduarda H.L.;Santaella, Gustavo M.;Freitas, Deborah Queiroz
    • Imaging Science in Dentistry
    • /
    • 제50권1호
    • /
    • pp.23-30
    • /
    • 2020
  • Purpose: This study was conducted to assess the effectiveness of a metal artifact reduction (MAR) algorithm activated at different times during cone-beam computed tomography (CBCT) acquisition on the magnitude of artifacts generated by a zirconium implant. Materials and Methods: Volumes were obtained with and without a zirconium implant in a human mandible, using the OP300 Maxio unit. Three modes were tested: without MAR, with MAR activated after acquisition, and with MAR activated before acquisition. Artifacts were assessed in terms of the standard deviation (SD) of gray values and the contrast-to-noise ratio (CNR) in 6 regions of interest with different distances (10 to 35 mm, from the nearest to the farthest) and angulations(70° to 135°) from the implant region. Results: In the acquisitions without MAR, the regions closer to the implant(10 and 15mm) had a higher SD and lower CNR than the farther regions. When MAR was activated (before or after), SD values did not differ among the regions (P>0.05). The region closest to the implant presented a significantly lower CNR in the acquisitions without MAR than when MAR was activated after the acquisition; however, activating MAR before the acquisition did not yield significant differences from either of the other conditions. Conclusion: Both modes of MAR activation were effective in decreasing the magnitude of CBCT artifacts, especially when the effects of the artifacts were more noticeable.

Influence of CBCT metal artifact reduction on vertical radicular fracture detection

  • Oliveira, Mariana Rodrigues;Sousa, Thiago Oliveira;Caetano, Aline Ferreira;de Paiva, Rogerio Ribeiro;Valladares-Neto, Jose;Yamamoto-Silva, Fernanda Paula;Silva, Maria Alves Garcia
    • Imaging Science in Dentistry
    • /
    • 제51권1호
    • /
    • pp.55-62
    • /
    • 2021
  • Purpose: This study evaluated the influence of a metal artifact reduction (MAR) tool in a cone-beam computed tomography (CBCT) device on the diagnosis of vertical root fractures (VRFs) in teeth with different root filling materials. Materials and Methods: Forty-five extracted human premolars were classified into three subgroups; 1) no filling; 2) gutta-percha; and 3) metallic post. CBCT images were acquired using an Orthopantomograph 300 unit with and without a MAR tool. Subsequently, the same teeth were fractured, and new CBCT scans were obtained with and without MAR. Two oral radiologists evaluated the images regarding the presence or absence of VRF. Receiver operating characteristic (ROC) curves and diagnostic tests were performed. Results: The overall area under the curve values were 0.695 for CBCT with MAR and 0.789 for CBCT without MAR. The MAR tool negatively influenced the overall diagnosis of VRFs in all tested subgroups, with lower accuracy (0.45-0.72), sensitivity (0.6-0.67), and specificity (0.23-0.8) than were found for the images without MAR. In the latter group, the accuracy, sensitivity, and specificity values were 0.68-0.77, 0.67-083, and 0.53-087, respectively. However, no significant difference was found between images with and without MAR for the no filling and gutta-percha subgroups (P>0.05). In the metallic post subgroup, CBCT showed a significant difference according to MAR use (P<0.05). Conclusion: The OP 300 MAR tool negatively influenced the detection of VRFs in teeth with no root canal filling, gutta-percha, or metallic posts. Teeth with metallic posts suffered the most from the negative impact of MAR.

Assessment of the efficiency of a pre- versus post-acquisition metal artifact reduction algorithm in the presence of 3 different dental implant materials using multiple CBCT settings: An in vitro study

  • Shahmirzadi, Solaleh;Sharaf, Rana A.;Saadat, Sarang;Moore, William S.;Geha, Hassem;Tamimi, Dania;Kocasarac, Husniye Demirturk
    • Imaging Science in Dentistry
    • /
    • 제51권1호
    • /
    • pp.1-7
    • /
    • 2021
  • Purpose: The aim of this study was to assess artifacts generated in cone-beam computed tomography (CBCT) of 3 types of dental implants using 3 metal artifact reduction (MAR) algorithm conditions (pre-acquisition MAR, post-acquisition MAR, and no MAR), and 2 peak kilovoltage (kVp) settings. Materials and Methods: Titanium-zirconium, titanium, and zirconium alloy implants were placed in a dry mandible. CBCT images were acquired using 84 and 90 kVp and at normal resolution for all 3 MAR conditions. The images were analyzed using ImageJ software (National Institutes of Health, Bethesda, MD) to calculate the intensity of artifacts for each combination of material and settings. A 3-factor analysis of variance model with up to 3-way interactions was used to determine whether there was a statistically significant difference in the mean intensity of artifacts associated with each factor. Results: The analysis of all 3 MAR conditions showed that using no MAR resulted in substantially more severe artifacts than either of the 2 MAR algorithms for the 3 implant materials; however, there were no significant differences between pre- and post-acquisition MAR. The 90 kVp setting generated less intense artifacts on average than the 84 kVp setting. The titanium-zirconium alloy generated significantly less intense artifacts than zirconium. Titanium generated artifacts at an intermediate level relative to the other 2 implant materials, but was not statistically significantly different from either. Conclusion: This in vitro study suggests that artifacts can be minimized by using a titanium-zirconium alloy at the 90 kVp setting, with either MAR setting.

Vertical root fracture diagnosis in teeth with metallic posts: Impact of metal artifact reduction and sharpening filters

  • Debora Costa Ruiz;Lucas P. Lopes Rosado;Rocharles Cavalcante Fontenele;Amanda Farias-Gomes;Deborah Queiroz Freitas
    • Imaging Science in Dentistry
    • /
    • 제54권2호
    • /
    • pp.139-145
    • /
    • 2024
  • Purpose: This study examined the influence of a metal artifact reduction (MAR) tool, sharpening filters, and their combination on the diagnosis of vertical root fracture (VRF) in teeth with metallic posts using cone-beam computed tomography (CBCT). Materials and Methods: Twenty single-rooted human premolars - 9 with VRF and 11 without - were individually placed in a human mandible. A metallic post composed of a cobalt-chromium alloy was inserted into the root canal of each tooth. CBCT scans were then acquired under the following parameters: 8 mA, a 5×5 cm field of view, a voxel size of 0.085 mm, 90 kVp, and with MAR either enabled or disabled. Five oral and maxillofacial radiologists independently evaluated the CBCT exams under each MAR mode and across 3 sharpening filter conditions: no filter, Sharpen 1×, and Sharpen 2×. The diagnostic performance was quantified by the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. These metrics were compared using 2-way analysis of variance with a significance level of α=5%. Intra- and inter-examiner agreement were assessed using the weighted kappa test. Results: Neither MAR nor the application of sharpening filters significantly impacted AUC or specificity (P>0.05). However, sensitivity increased when MAR was combined with Sharpen 1× and Sharpen 2× (P=0.015). The intra-examiner agreement ranged from fair to substantial (0.34-0.66), while the inter-examiner agreement ranged from fair to moderate (0.27-0.41). Conclusion: MAR in conjunction with sharpening filters improved VRF detection; therefore, their combined use is recommended in cases of suspected VRF.

Assessment of metal artifacts in three-dimensional dental surface models derived by cone-beam computed tomography

  • Nabha, Wael;Hong, Young-Min;Cho, Jin-Hyoung;Hwang, Hyeon-Shik
    • 대한치과교정학회지
    • /
    • 제44권5호
    • /
    • pp.229-235
    • /
    • 2014
  • Objective: The aim of this study was to assess artifacts induced by metallic restorations in three-dimensional (3D) dental surface models derived by cone-beam computed tomography (CBCT). Methods: Fifteen specimens, each with four extracted human premolars and molars embedded in a plaster block, were scanned by CBCT before and after the cavitated second premolars were restored with dental amalgam. Five consecutive surface models of each specimen were created according to increasing restoration size: no restoration (control) and small occlusal, large occlusal, disto-occlusal, and mesio-occluso-distal restorations. After registering each restored model with the control model, maximum linear discrepancy, area, and intensity of the artifacts were measured and compared. Results: Artifacts developed mostly on the buccal and lingual surfaces. They occurred not only on the second premolar but also on the first premolar and first molar. The parametric values increased significantly with increasing restoration size. Conclusions: Metallic restorations induce considerable artifacts in 3D dental surface models. Artifact reduction should be taken into consideration for a proper diagnosis and treatment planning when using 3D surface model derived by CBCT in dentofacial deformity patients.