• Title/Summary/Keyword: Mesurement system

Search Result 28, Processing Time 0.027 seconds

Design of Facial Image Data Collection System for Heart Rate Measurement (심박수 측정을 위한 안면 얼굴 영상 데이터 수집 시스템 설계)

  • Jang, Seung-Ju
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.7
    • /
    • pp.971-976
    • /
    • 2021
  • In this paper, we design a facial facial image data collection system for heart rate measurement using a web camera. The design content of this paper is a function of collecting user face image information using a web camera and measuring heart rate using the user's face image information. There is a possibility that an error may occur due to non-contact heart rate measurement using a web camera. Therefore, in this paper, it is to be used for correcting heart rate program errors through classification of data in cases of error and normal. The data in case of error can be used for the purpose of reducing the error. Experiments were conducted on the proposed ideas and designed in this paper. As a result of the experiment, it was confirmed that it operates normally.

A STUDY ON THE BITING FORCE OF ANTERIOR OPENBITE AND NORMAL OCCLUSION ADULTS (정상교합자와 전치부 개방교합자의 교합력에 관한 연구)

  • Kim, Dong-Ho;Lee, Dong-Joo
    • The korean journal of orthodontics
    • /
    • v.25 no.4
    • /
    • pp.487-495
    • /
    • 1995
  • This study was undertaken to compare each maximum biting force and to investigate its relationship with the facial skeketal form, number and position of tooth contact between anterior openbite and normal occlusion adults, using the T-scan system and the lateral cephalogram. The subjects of this study consisted of a group of 25 individuals with normal occlusion and another group of 14 with anterior openbite. The obtained results of this study were as follows : 1. The maximum biting force of anterior openbite adults was less than that of normal occlusion adults. 2. In anterior openbite adults, there were negative correlations between the maximum, biting force and SN/MP, FMA, PP/MP mesurement of lateral cephalogram. 3. In anterior openbite adults, as the mesial angulation of lower first molar against the occlusal plane increased, the more the biting force decreased. 4. In both groups, the greater the number of tooth contact, the more the biting force increased. 5. In both groups, the center of effort for anteroposterior occlusal contact was located on the first molar region.

  • PDF

The Graft Polymerization of Acrylic Acid in Vapour Phase onto Poly(ethylene terephthalate) by Cold Plasma Part (I) (저온 Plasma를 이용한 Poly(ethylene terephthalate)에의 Acrylic Acid의 기상 Graft 공중합 반응(I))

  • 천태일;최석철;모상영
    • Textile Coloration and Finishing
    • /
    • v.1 no.1
    • /
    • pp.7-18
    • /
    • 1989
  • The distinguishing characteristic of the glow discharge is that chemical reaction induced by partially ionized gases are limited only to the substrate surface. Most studies have been done on the plasma etching and polymerization. The graft polymerization in vapour phase by cold plasma has been rarely investigated. In this study the system of tub3ar reaction chamber with capacitively coupled electrode of alternative current of 60 Hz was employed for the graft polymerization. The graft polymerization of Acylic Acid(AA) onto the poly (ethylene terephthalate) (PET) was carried out by treatment of PET film and fabric by cold plasma (glow discharge of argon gas), followed by the supply of AA vapour. The graft yield was about 1 wt%. The surface property was determined by contact angle, the surface tension was evaluated by zisman’s plot and equation of surface tension mesurement. The results were as follows: 1. In order to obtain lower contact angle, it was effective to avoid the vicinity of electrodes for a setting position of substrate. 2. Contact angle affected on the monomer pressure and its duration of exposure to the acid vapour. 3. Polymer radical formation was influenced by the changes of the value of current density and plasma treatment time. 4. Total surface tension of plasma grafted PET film increased. With an increase in the carboxylic acid content, the dispersion force decreased, while, the polar force and hydrogen bonding force increased. 5. The contact angle decreased from $75^\circ$ to around $30^\circ$ by plasma grafting. There was no ageing effect on the contact angle after 4 months.

  • PDF

MARGINAL FIDELITY AND FRACTURE STRENGTH OF IN-CERAM CROWNS ACCORDING TO VARIOUS RESIN CEMENTS (접착재의 종류에 따른 In-Ceram 도재관의 변연적합도와 파절강도에 관한 연구)

  • Lim, Ju-Hwan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.6
    • /
    • pp.888-899
    • /
    • 1998
  • In-Ceram system is one of contemporary esthetic all ceramic restorations and has relatively high flexural strength. The purpose of this study was to evaluate the marginal fidelity according to type of resin cement and measuring position, and to evaluate fracture strength according to type of resin cement. In this study, twenty seven In-Ceram crowns were fabricated on the metal master die of prepared maxillary right central incisor and devided into three groups. All specimens were cemented with Panavia 21 (group PV), Super-bond (group SB) and Lute-it (group LI) on the metal master die. After cementation, specimens were measured marginal gap between the margin of the In-Ceram crown and the finishing line of metal master die by using a stereomicroscope (SZ-ST, Olympus, Japan). Marginal gaps were recorded at the labial, lingual, mesial and distal measuring points on the metal master die. For the mesurement of fracture strength, lingual surfaces of cemented specimens were loaded at a distance of 1mm from incisal edge by using the Autograph S-2000 (Shimadzu, Japan). The results of marginal fidelity and fracture strength were statistically analyzed with the SPSS version 8.0 programs. The results of this study were as follows: 1. In comparison of marginal fidelity according to the measuring points, there was no significant difference. 2. The marginal fidelity according to the type of resin cement was decreased in order of group $LI\;(63.75{\mu}m),\;SB\;(77.78{\mu}m),\;PV\;(86.53{\mu}m)$, and there was significant difference between group LI and PV (p<0.05). 3. The fracture strength according to the type of resin cement was showed descending order of group $LI\;(60.00kg/cm^2),\;SB\;(56.80kg/cm^2),\;PV\;(56.11kg/m^2)$, but there was no significant difference.

  • PDF

COMPARISON OF IMAGE REFORMATION USING PERSONAL COMPUTER WITH CT SCAN RECONSTRUCTION (CT 스캔 영상재구성과 개인용 컴퓨터를 이용한 영상 재형성과의 비교에 관한 연구)

  • Jung Gi-Hun;Kim Eun-Kyung;Kim Sang-Joon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.361-368
    • /
    • 1994
  • Radiographic planning is needed for implant placement in order to determine implant length, jaw bone volume, anatomical stucture and so on. Radiographic examination includes conventional radiography, conventional tomography and CT scan. The most accurate mesurement can be obtained from CT scan. For the cross-sectional view of mandible, CT scan reconstruction is generally needed. But the cross-sectional view of mandible can be reformed by personal computer. This study was performed to examine the clinical usefulness of reformed image using personal computer in comparison with CT scan reconstructed image. CT axial slices of 4 mandibles of 4 volunteers were used. Digital imaging system was composed of Macintosh Ⅱ ci computer, high resolution Sony XC-77 CCD camera, Quick Capture frame grabber board and 'NIH Image' program. Seven reconstructed cross-sectional images within CT machine(CT group) were obtained. And seven reformed cross-sectional images(PC group) after digitization of CT axial slices into the personal computer were obtained. PC group was compared with CT group in the objective and subjective aspects. The results were as follow: 1. Measurement of mandibular height & width in both group showed insignificant difference(P>0.05). 2. Subjective assessment of the mandibular canal in both group showed insignificant difference(P>0.05). 3. Image reformation using personal computer could provide panoramic view, which could not be obtained in CT scan reconstruction.

  • PDF

The Concept and Mesurement of Resource Rent and Profit (자원 렌트와 이익의 개념 및 측정에 관한 연구)

  • Nam, Soo-Hyun
    • The Journal of Fisheries Business Administration
    • /
    • v.49 no.1
    • /
    • pp.67-89
    • /
    • 2018
  • In fisheries, as well as in other natural resource-based industries, there is difference between profit and rent. The former is a basic indicator for gauging the business performance of firms, while the latter is for the evaluation of the contribution of resources and industry to economic welfare. Put simply, resource economists are mainly concerned about rent, including pure resource rent and producer surplus (intra-marginal rent [IMR]). In other hand, business economists are mainly concerned about the profitability of the firms comprising the industry. In the academic literature, there are not always clear definitions of the profit and rent concepts and their use in actual analyses. This article will mainly discuss and clarify differences and similarities in profit and rent concepts. In the classical fisheries economic model with one-dimensional homogenous effort and a constant cost per unit of effort, no rent exists in open-access equilibrium. A simple change in this model, for example by introducing heterogeneous effort, opens it to the existence of rent, specifically IMR, at open-access equilibrium. We estimated resource rent and profit from the data using SNA(system of national accounts) and accounting data methods. RR(resource rent) is composed of value-added, compensation of employees, consumption of fixed capital and normal profit in SNA. RR(resource rent) is composed of EBT, Depreciation of fishing rights, financial costs of fishing rights and calculated interests on equity in accounting data methods. We found that the result of two methods is equal. RR is composed of excess profit, rent and interest expenses. In Korea, the magnitude of RR and profit is not different significantly.

The Analysis of the Factors and Weights for the Performance Mesurement of Hospital CRM System (병원의 CRM시스템 성과측정을 위한 주요요인 및 가중치 분석)

  • Hong, Hyun-Gi;Chun, Je-Ran
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.4
    • /
    • pp.915-923
    • /
    • 2007
  • Recently we can see many cases that the CRM Systems are implemented and operated in Hospitals. The reason for such situation is the management environments in medical service market is changing rapidly one hand, and on the other hand the competitions among the Hospitals became more severe. In this paper we try to present the factors and weights as index for the measurement of Hospital CRM's System Performance. To achieve this goal, we derived the primary factors for the success of the CRM Systems based on the precedent researches, and futhermore carry out the verification of the rightness of those factors. For the verification of the rightness of the factors, we employ the Structured-Model-Analysis Method of AMOS. This enhance the meaning of the analysis result of the factors. And we use the AHP method to compare the importance grade of each success factors, because the comparison of importance level of each success factor is very crucial for the measurement of the Hospital CRM's system performance. As a result, we derived the primary factors and analyzed the weights in this paper, which might be used as the guiding Index for the measurement of the Hospital CRM' System Performance.

  • PDF

A Study on the Development of Capacitor Exchange Type GDU of Propulsion Control Device of Electric Railway Vehicle Capable of Life Diagnosis (수명진단이 가능한 전기철도차량 추진제어장치의 커패시터 교환 형 GDU 개발에 관한 연구)

  • Kim, Sung Joon;Chae, Eun Kyung;Kang, Jeong Won
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.7
    • /
    • pp.475-484
    • /
    • 2018
  • The propulsion control device of an electric railway vehicle is a key main component corresponding to an engine of an automobile, and a device for controlling this is a device called a GDU (Gate Drive Unit). Also, when the frequency of failure of the propulsion control system was analyzed, the nonconformity ratio of GDU was the highest. GDU was not able to access core technologies due to the introduction of foreign products, and there were general problems with overall maintenance activities due to discontinuation of GDU of the manufacturer. The GDU has reached the end of its life with 23 to 14 years of long-term use.In order to solve these problems, this study was designed to identify the proper life span by analyzing compatible GDU's acquisition and failure, and to improve the existing system of maintenance focusing on health inspection. Maintenance of the components with a short life span compared to the entire service life is essential. Most foreign parts introduced at the beginning of the construction are not replaced due to technical problems or long-term operation. However, due to the characteristics of railway vehicles with a long life span of more than 25 years, it is necessary to maintain them for a long period of time. The study should be more concrete and empirical. The replacement type GDU of capacitors was able to easily measure the life of the capacitance by removing the capacitor modules, measure the life span of each unit test, and accurately perform preventive maintenance of the capacitor.