• Title/Summary/Keyword: Mercury measurement

Search Result 90, Processing Time 0.04 seconds

Replacing Mercury Sphygmomanometers With Mercury-Free Sphygmomanometers for the National Health Survey in Children: Direct Comparisons Applying Two Types of Mercury-Free Sphygmomanometer

  • Sung Hye Kim;Yu-Mi Kim;Seong Heon Kim;Jinho Shin;Eun Mi Lee
    • Korean Circulation Journal
    • /
    • v.54 no.5
    • /
    • pp.270-287
    • /
    • 2024
  • Background and Objectives: Blood pressure (BP) measurement using an auscultatory sphygmomanometer is recommended for diagnosing hypertension in children. As mercury sphygmomanometers (MSs) are banned owing to environmental concerns, it is crucial to determine the accuracy of mercury-free sphygmomanometers to replace them. We analyzed the accuracy of these devices to guide the National Survey selection. Methods: BP was measured thrice each with MS, auscultatory device (AD), and oscillometric device (OD) in 104 participants aged 10-18 using the National Survey data. The difference in BP was defined as the difference between MS and other devices. The BP differences, correlations, and influencing factors were analyzed. The frequencies of hypertension were also compared. Results: Systolic BP (SBP) and diastolic BP (DBP) differences between MS and AD were 0.88±3.36 mmHg and 0.63±3.95 mmHg, and those between MS and OD were 0.43±5.83 mmHg and 4.57±6.89 mmHg, respectively. The absolute error of <10 mmHg for DBP between MS and OD was 76%. The concordance correlation coefficient between MS and AD was 0.94 for SBP and 0.90 for DBP, and 0.81 and 0.67, respectively for MS and OD. Arm circumference negatively correlated with BP differences except for SBP between the MS and OD. The frequency of hypertension was not different between MS and AD but was underestimated by OD. Conclusions: AD correlated well with MS, while OD did not, especially for DBP. The superiority of AD over OD suggests AD as a possible alternative for MS in the National Survey.

Evaluating the Accuracy of Blood Pressure Measurement (혈압측정의 정확성 평가)

  • Cho, Sung-Hyun;Hwang, Jeong-Hae;Kim, Eun-Gyung;Oh, Byung-Hee;Kim, Chang-Yup
    • Quality Improvement in Health Care
    • /
    • v.3 no.1
    • /
    • pp.94-103
    • /
    • 1996
  • Background : Blood pressure is an important indicator in diagnosis and assessing treatment of a patient. Clinical staffs use blood pressure on the assumption that measured value is accurate and reliable. However, whether measured blood pressure is accurate has been rarely investigated in Korea. Objectives : The aims of this study are to evaluate clinical staffs' knowledge and technique as well as accuracy of sphygmomanometer. Also the program to improve the measurement is developed. Methods : Seventy-three registered nurses were asked nine multiple choice questions including Korotkoff sound, cuff size, and deflation rate. Simultaneously characteristics of nurses were examined, age, working place, duration of employment and academic degree. A testing videotape(Standardizing Measurement Video-Tutored Course) was used for evaluating the accuracy of measurement. Testees were to read and record the 12 cases of blood pressure measurement, watching a falling mercury column and hearing Korotkoff sounds. After 10 minutes' education, they were again tested with the same cases. Additionally, 83 mercury sphygmomanometers were checked to find defects such as inaccurate calibration and zero setting, leaky bladder, etc. Results: For the knowledge testing correct response rate was 41.1%. They were the lowest in selecting the proper cuff size and Korotkoff sound. In examining accuracy of blood pressure with videotape, nurses had 67.7% correct response rate. The correct response rate was significantly improved by a session of education. About 23% of sphygmomanometers was without discernable defects. Conclusion : The knowledge and skill of clinical staffs along with the accuracy of equipment have to be improved. A properly designed education program would contribute to the accuracy improvement of blood pressure measurement. Also, more concerns should be given to the precision and maintenance of equipment.

  • PDF

Changes in Atmospheric Mercury Concentrations in Seoul, Korea and its Significance: A Case Study Between 1997 and 2002

  • Kim Ki-Hyun;Kim Min-Young;Hong SM
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.E1
    • /
    • pp.1-11
    • /
    • 2005
  • The concentration levels of gaseous elemental mercury (GEM) in ambient air have been investigated from a monitoring station located in Yang Jae district of Seoul, Korea for a long-term period covering 1997 through 2002. The mean concentration of Hg, if computed based on its hourly measurement data for this six-year period, was $5.32\pm3.53 ng m^{-3} (N = 27,170)$. The inspection of the diurnal distribution patterns indicated the presence of notably high concentration levels during nighttime relative to daytime (e.g., the mean hourly value as high as $9 ng m^{-3}$ in winter nighttime). When divided seasonally, the highest mean of $6.12 ng m^{-3}$ was also observed during winter followed by spring, fall, and summer. The results of our analysis confirmed the relative dominance of winter (seasonally) or nighttime (diurnally), while exhibiting a complicated trend on a long-term basis. Examination of our data over a different temporal scale consistently indicated that dynamic changes in Hg concentrations occurred through time in line with changes in the strength and diversity of the source processes. It is thus acknowledged that the presence of unusually high Hg levels is the consequence of intense man-made activities, while such signatures can vary in a competitive manner.

Atmospheric Chemistry of Mercury in the Polar Regions and its Environmental Implications (극지환경 수은의 대기화학과 환경학적 의미)

  • Schroeder, WH;Kim, Min-Young;Hong, Sung-Min;Shon, Zang-Ho;Kim, Ki-Hyun
    • Journal of the Korean earth science society
    • /
    • v.24 no.5
    • /
    • pp.420-427
    • /
    • 2003
  • The results of recent studies indicate that atmospheric distribution of Hg in the arctic environment is unique enough to show strong depletion during spring followed by notable increases during summer. The observations of this abnormal trend contrast quite sharply with what had been recognized as Hg geochemical behavior in air over the past decades. Using the long-term measurement data of Hg obtained from both the Arctic and Korea, we attempted to provide valuable insights into the unique mercury depletion phenomenon (MDP) in the polar regions of the globe.

The study of X-ray detection characteristic and fabrication photoconductor film thickness for Screen printing method (Screen printing method로 제작된 의료용 광도전체 필름의 Tickness의 따른 X선 검출 특성 평가)

  • Lee, Y.K.;Yon, M.S.;KIM, D.H.;Chun, S.L.;Jung, B.D.;Gang, Sang-Sik;Park, J.G.;Mun, C.W.;Nam, S.H.
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.2
    • /
    • pp.11-16
    • /
    • 2009
  • Mercury Iodide as good sensitivity at radiation and has an easy peculiarity that operates at low voltage for other photoconductors(a-Se, a-Si, Ge, etc) Based on this characteristic, we studied about an efficiency of the digital x-ray detector in acccordance with the thickness of photoconductor. To solve the problem that is difficult to make a large area film using PVD(Physical Vapor Deposition)method, we used a PIB(Particle In Binder)method. To make a binder paste, we used a PVB(Polyvinylbutyral) as a binder and a DGME(Diethylene Glycol Monobutyl Ether), DGMEA(Diethylene Glycol Monobutyl Ether Acetate) as a solvent. Using this binder paste, we made a polycrystal mercury iodide film that has an each thickness. To evaluate the electrical properties of this films, we measured a darkcurrent, sensitivity and SNR(Signal to Noise Ratio). Mercury iodide film of the 200um thickness has good electrical properties as a result of the measurement. From this result there is a good chance that replace the existing a-Se(Amnorphous seleinum; a-se) with the mercury iodide.

  • PDF

Effect of SO2 on the Simultaneous Removal of Mercury and NOx over CuCl2-loaded V2O5-WO3/TiO2 SCR Catalysts (CuCl2가 담지된 V2O5-WO3/TiO2 SCR 촉매에 의한 수은 및 NOx 동시 제거에서 SO2의 영향)

  • Ham, Sung-Won
    • Clean Technology
    • /
    • v.28 no.1
    • /
    • pp.38-45
    • /
    • 2022
  • CuCl2-loaded V2O5-WO3/TiO2 catalyst showed excellent activity in the catalytic oxidation of elemental mercury to oxidized mercury even under SCR condition in the presence of NH3, which is well known to significantly inhibit the oxidation activity of elemental mercury by HCl. Moreover, it was confirmed that, when SO2 was present in the reaction gas together with HCl, excellent elemental mercury oxidation activity was maintained even though CuCl2 supported on the catalyst surface was converted to CuSO4. This is thought to be because not only HCl but also the SO4 component generated on the catalyst surface promotes the oxidation of elemental mercury. However, in the presence of SO2, the total mercury balance before and after the catalytic reaction was not matched, especially as the concentration of SO2 increased. In order to understand the cause of this, further studies are needed to investigate the effect of SO2 in the SnCl2 aqueous solution employed for mercury species analysis and the effect of sulfate ions generated on elemental mercury oxidation. It was confirmed that SO2 also promotes NOx removal activity, which is thought to be because the increase in acid sites by SO4 generated on the catalyst surface by SO2 facilitates NH3 adsorption. The composition change and structure of the components present on the catalyst surface under various reaction conditions were measured by XRD and XRF. These measurement results were presented as a rational explanation for the results that SO2 enhances the oxidation activity of elemental mercury and the NOx removal activity in this catalyst system.

3rd Order Type Mercury Rotate Marine Light with LED Optical System (LED광학 시스템이 포함된 3등대형 수은조식 해상용 등명기 개량)

  • Kim, Yeong-Jae;Kang, Dae-Woong;Lee, Yong-Jae;Jeong, Hwan;Lee, Jong-Bok;Shin, Kyung-Ho;Park, Kwang-Woo;Yoo, Seong-Hwan
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2017.11a
    • /
    • pp.206-208
    • /
    • 2017
  • In recent years, we have been working on the improvement project of mercury 3-lecture type at the Geummundo lighthouse for more than 100 years. We have installed toxic mercury removal, LED light source, and dualization system for nonstop. It can be seen as an example. Circular restoration of the entire frame is performed, and the real-time status can be grasped through the installation of the double-ball bearing and the remote control system. After installation, optical measurement through Hanvit secured the optical performance of 2,000,000 cd of floating brightness of 300cd, proving the efficient possibility of introducing the domestic rotary type light source using LED light source.

  • PDF