• Title/Summary/Keyword: Mercury Lamp

Search Result 149, Processing Time 0.02 seconds

Investigation of Turn-off Condition for Reliable Operation of Mercury Vapor Lamp

  • Park, Jun-Sung;Jeong, Sang-Sik;Lee, Seung-Gyu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1152-1154
    • /
    • 2007
  • The distributions of mercury (Hg) in the bulb of a mercury vapor lamp are significantly affected by its turn-off conditions. Most of mercury should be attached to the electrodes before ignition by a proper turn-off condition. In the present study, the effect of the transient profiles of lamp cooling after turn-off on the distribution of Hg was investigated.

  • PDF

Characteristics of Mercury Concentration in Vapor Phase from Compact Fluorescent Lamp (소형형광등(Compact Fluorescent Lamp)의 파쇄에 따른 기상에서의 수은농도 특성)

  • Rhee, Seung-Whee
    • Korean Chemical Engineering Research
    • /
    • v.52 no.5
    • /
    • pp.652-656
    • /
    • 2014
  • Mercury amount in vapor phase from 3 types of CFL(compact fluorescent lamp) are estimated by measuring mercury concentration in vapor phase. The mercury concentration in vapor phase from CFL is sharply decreased during initial time and then the change in the mercury concentration is slightly decreased up to 24 hours. The mercury concentration in vapor phase is almost constant after 42 hours, which can be called by stabilized concentration. It can be estimated that the stabilized concentration is caused by the evaporation of mercury in the residues of broken CFL and can be affected by temperature and pressure in crushing apparatus. The mercury concentration for CFL manufactures are in the order of A < B < C as the same results of the initial mercury concentration and the stabilized concentration in vapor phase. As increased air flow rate, the partial pressure of mercury is decreased and the amount of mercury is reduced. Initially, the mercury concentration in vapor phase emitted from CFLs is higher than the regulatory level of $0.1mg/m^3$ in the specific facilities regardless of air flow rate. Hence, it is absolutely necessary that mercury in vapor phase should be controlled at the point of crushing campact fluorescent lamp.

Fluid Flow and Heat Transfer in a Super high-Pressure Mercury Lamp using CFD

  • Jang, Dong Sig;Lee, Yeon Won;Li, Kui Ming;Parthasarathy, Nanjundan;Choi, Yoon Hwan
    • International Journal of Safety
    • /
    • v.11 no.2
    • /
    • pp.5-9
    • /
    • 2012
  • The discharge properties of super high-pressure mercury lamp are due to resistance heating for energy input, and results in temperature increase. The cooling equilibrium state is reached by the heat conduction, convection and radiation. In order to predict the fluid flow and heat transfer in and around the mercury lamp accurately, its visualization is of utmost importance. Such visualization is carried out by CFD program in this study. We focus on Anode shape to calculate four cases, namely AA, AB, AC and AD separately, and compare the temperature distribution and velocity vector in each case to predict cooling capacity and fluid flow properties. It can be concluded that the shape of anode plays an important role that affects the fluid flow and heat transfer in a mercury lamp.

Electronic Temperature and Density of Mixed Gases in Inductively Coupled Plasma Lighting System (Ne:Xe) (Inductively Coupled Plasma 광원 시스템의 Ne:Xe 혼합가스의 전자온도 및 전자밀도 특성)

  • Choi, Yong-Sung;Gu, Hal-Bon;Lee, Jin;Lim, Jong-Yeol;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.12a
    • /
    • pp.91-95
    • /
    • 2006
  • In whole world consciousness of environment maintenance have increased very quickly for the end of the 20th century. To use and disuse toxic substances have been controled at the field of industry. Also the field of lighting source belong to environmental control. And in the future the control will be strong. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem root. In the mercury free lighting source system the Xe gas lamp is one type. And the Ne:Xe mixing gas lamp improvements firing voltage of Xe gas lamp. Purpose and subject of this study are understand, efficiency, ideal of Ne:Xe plasma which mercury free lamp. Before ICP was designed, basic parameters of plasma, which are electron temperature and electron density, were measured and calculated by langmuir probe data. Property of electron temperature and electron density were confirmed by changing ratio of Ne:Xe.

  • PDF

Effects of the Xe content on the electro-optical properties in the mercury-free Flat Fluorescent Lamp

  • Chung, Kyu-Yong;Lee, Sang-Mok;Jeong, Yoon-Chul;Sohn, Sang-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1577-1579
    • /
    • 2007
  • Xe content is one of important factors related to characteristics of the mercury-free flat fluorescent lamp. The electro-optical properties of lamp were investigated for wide range of Xe content in Xe-Ne mixing gas. The maximum luminance of $9,289\;cd/m^2$ and efficacy of 3 lm/W was obtained with Xe 90 %.

  • PDF

A Growth Responses of Indoor Ground Cover Plants according to a Light Source of Aritificial Light (인공광의 광원에 따른 실내 지피식물의 생육반응)

  • 방광자;박혜경;최경옥
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.27 no.5
    • /
    • pp.114-119
    • /
    • 2000
  • This study was carried out to obtain fundamental information of growth response of ground cover plants under artificial light quality at indoor. Aglaonema 'Silver Queen', Hedera helix L., Hoya carnosa 'Tricolor' and Saintpaulia ionantha 'Frances' were examined under a 400lux light intensity consisted of Mercury lamp, True-lite lamp, incandescent lamp, dark-room and sunlight indoor condition. A data analysis were performed by GLM, Duncan's multiple range test and mean score with SAS program. Results of experiments are as follows; 1. A plant growth status was better showed under the True-lite lamp than sunlight. 2. A Saintpaulia ionantha flower color was responded in the first place, the deep pinkish red color of Saintpaulia ionantha flower was obtained under Mercury lamp and "True-lite lamp", "sunlight", and incandescent lamp were follow. Flower numbers of Saintpaulia ionantha after 60 days tended to decrease under every artificial light quality. 3. Leaf length and leaf width were increased under True-lite lamp, but most of plants was not significantly affected by artificial light quality. 4. A stem length of Hedera helix was increased the highest rank under sunlight also, one of artificial light, the highest increase rank was showed under incandescent lamp. 5. Chlorophyll content was highly increased under Mercury lamp, but was responded poor under incandescent lamp.

  • PDF

The Electron temperature and Density properties of Mixing gas in ICP Lighting system(Ne:Xe, Ne:Ar) (ICP 광원 시스템의 Ne:Xe Ne:Ar 혼합가스의 전자온도 및 전자밀도의 특성 연구)

  • Choi, Gi-Seung;Lee, Jonh-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2424-2426
    • /
    • 2005
  • In whole world consciousness of environment maintenance have increased very quickly for he end of the 20th century. To use and disuse toxic substances have been controled at the field of industry. Also the field of lighting source belong to environmental control. And in the future the control will be strong. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem. In radiational mechanism of fluorescence lamp mercury is the worst environmental problem root. In the mercury free lighting source system the Xe gas lamp is one type. And the Ne:Xe and Ne:Ar mixing gas lamp improvements firing voltage of Xe gas lamp. Purpose and subject of this study are understand, efficiency, ideal of Ne:Xe and Ne:Ar plasma which mercury free lamp. Before ICP was designed, basic parameters of plasma, which are electron temperature and electron density, were measured and calculated by langmuir probe data. Property of electron temperature and electron density were confirmed by changing ratio of Ne:Xe and Ne:Ar.

  • PDF

Pulse Density Modulated ZVS High Frequency Inverter with Reverse Blocking Single Switch for Dielectric Barrier Discharge Lamp Dimming

  • Sugimura Hisayuki;Yasui Kenji;Omori Hideki;Lee Hyun-Woo;Nakaoka Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.206-209
    • /
    • 2006
  • At present, the cold cathode fluorescent lamp (CCFL) using mercury lamp has been generally used far liquid crystal backlight source of personal computer and car navigation and so on. This kind of lamp is more excellent on luminance performance and cost. However, the requirements of liquid crystal backlight due to a light source without mercury have been strongly increased from a viewpoint of the actual influence on environmental preservation and environmental recycling. As fluorescent lamp without mercury, Dielectric Barrier Discharge based rare gas fluorescent lamp (DBD-FL) using xenon (Xe) gas has been studied so far. This DBD lamp has no influence on the human body and environmental recycle. Its operating life is long because electrode is out. In this paper, the simulation and experimental results of soft switching high frequency inverter with reverse blocking single switch as a high frequency power supply circuit for DBD-FL using Xe gas are comparatively evaluated and discussed from a practical point of view.

  • PDF

Performance Evaluation of 2-Dimensional Light Source using Mercury-free Flat Fluorescent Lamps for LCD Backlight Applications

  • Park, Joung-Hu;Cho, Bo-Hyung;Lee, Ju-Kwang;Whang, Ki-Woong
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.164-172
    • /
    • 2009
  • Recently, 2-dimensional flat light sources have been attracting much attention for its use in LCD backlight applications because of its high luminous efficiency and uniformity. A long-gap discharge, mercury-tree flat fluorescent lamp has been developed, which shows a high brightness ($>5000\;cd/m^2$) and high luminous efficacy (60 lm/W). Additionally, it has a wide operating margin and stable driving condition with the aid of an auxiliary electrode. For driving the lamp, a narrow pulse power to maintain the glow discharge state is required. Since there has been no research for this kind of lamp driving, this paper proposes a newly developed short-pulse, high-voltage lamp-driving scheme. The proposed lamp system uses a ballast with a coupled-inductor in order to raise the short pulse voltage up to the lamp ignition level and to obtain energy-recovery action during the glow discharge mode. The operation principles are presented and also the system performances such as the lighting efficiency, spatial and angular uniformities are evaluated by hardware experiments. The results show that the proposed lighting system is a good candidate for the next-generation of LCD backlight systems.