• 제목/요약/키워드: Mercaptoundecanoic-acid

검색결과 15건 처리시간 0.026초

Patterning Biological Molecules onto Poly(amidoamine) Dendrimer on Gold and Glass

  • Hong, Mi-Young;Lee, Do-Hoon;Yoon, Hyun C.;Kim, Hak-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권8호
    • /
    • pp.1197-1202
    • /
    • 2003
  • Patterning of biological molecules was attempted on both gold and glass using fourth generation (G4) poly(amidoamine) (PAMAM) dendrimer as an interfacing layer between solid surfaces and biomolecules. As for the patterning of avidin and anti-biotin antibody on gold, PAMAM dendrimers representing amine functionalities were firstly printed onto the 11-mercaptoundecanoic acid SAM by microcontact printing, followed by biotinylation, and reacted with fluorescence-labeled avidin or anti-biotin antibody. Fluorescence microscopic analysis revealed that the patterns of avidin and anti-biotin antibody were well constructed with the resolution of < 2 ㎛. The PAMAM dendrimers were also printed onto aldehyde-activated slide glass and reacted directly with anti-BSA antibodies, which had been oxidized with sodium periodate. As a result, distinct patterns of the anti-BSA antibodies were also obtained with a comparable edge resolution to that of avidin patterns on gold. These results clearly show that PAMAM dendrimers can be adopted as an interfacing layer for the patterning of biological molecules on solid surfaces with micrometer resolution.

Immunosensor for Detection of Escherichia coli O157:H7 Using Imaging Ellipsometry

  • Bae Young-Min;Park Kwang-Won;Oh Byung-Keun;Choi Jeong-Woo
    • Journal of Microbiology and Biotechnology
    • /
    • 제16권8호
    • /
    • pp.1169-1173
    • /
    • 2006
  • Imaging ellipsometry (IE) for detection of binding of Escherichia coli O157:H7 (E. coli O157:H7) to an immunosensor is reported. A protein G layer, chemically bound to a self-assembled layer of 11-mercaptoundecanoic acid (11-MUA), was adopted for immobilization of monoclonal antibody against E. coli O157:H7 (Mab). The immobilization of antibody was investigated using surface plasmon resonance. To fabricate antibody spots on a gold surface, protein G solution was spotted onto the gold surface modified with an 11-MUA layer, followed by immobilizing Mab on the protein G spot. Ellipsometric images of the protein G spot, the Mab spot, and Mab spots with binding of E. coli O157:H7 in various concentrations were acquired using the IE system. The change of mean optical intensity of the Mab spots in the ellipsometric images indicated that the lowest detection limit was $10^3$CFU/ml for E. coli O157:H7. Thus, IE can be applied to an immunosensor for detection of E. coli O157:H7 as a detection method with the advantages of allowing label-free detection, high sensitivity, and operational simplicity.

Construction and Patterning of the biospecific affinity surfaces on gold using dendrimer

  • 홍미영;윤현철;김학성
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 추계학술발표대회 및 bio-venture fair
    • /
    • pp.703-706
    • /
    • 2000
  • We constructed a biospecific affinity surface using hyper-branched dendrimers on gold for biospecific recognition, and characterized the resulting surfaces by using confocal fluorescence microscopy. The dendrimer monolayer was firstly constructed on the mercaptoundecanoic acid SAM/Au with pentafluorophenyl ester activation and further functionalized with sulfo-NHS-biotin, an activated ester of biotin. To confirm the formation of biospecific affinity surface, FITC(fluorescein isothiocyanate)-labeled avidin was loaded onto the biotinylated dendrimer monolayer, and fluorescence images of the bound avidins were investigated with a confocal microscope. The constructed biospecific affinity surface showed a much more dense and uniform fluorescence compared to those from poly-L-lysine- and cystamine SAM-based affinity surfaces. For the dependency on the concentration of added FITC-labeled avidin on the affinity surface, derived fluorescence could be detectable from as low as $1{\mu}g/ml$, and intensified up to $50{\mu}g/ml$. Further reaction of FITC-labeled avidin layer with TMR(tetramethylrhodamine)-biocytins resulted in the efficient FRET(fluorescence resonance energy transfer) phenomenon. As an extension of the study, we attempted a patterning of the affinity surfaces on gold by microcontact printing. Fluorescence of the patterned surface demonstrated that FITC-labeled avidin molecules were specifically bound to the biotinylated patches.

  • PDF

Detection of Escherichia coli O157:H7 Using Immunosensor Based on Surface Plasmon Resonance

  • Oh, Byung-Keun;Kim, Young-Kee;Bae, Young-Min;Lee, Won-Hong;Choi, Jeong-Woo
    • Journal of Microbiology and Biotechnology
    • /
    • 제12권5호
    • /
    • pp.780-786
    • /
    • 2002
  • An immunosensor based on surface plasmon resonance (SPR) with a self-assembled protein G layer was developed for the detection of Escherichia coli O157:H7. A self-assembled protein C layer on a gold (Au) surface was fabricated by adsorbing the mixture of 11-mercaptoundecanoic acid (MUA) and hexanethiol at various molar ratios and by activating chemical binding between free amine (-$NH_2$) of protein G and 11-(MUA) using 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDAC) in series. The formation of a self-assembled protein G layer on an Au substrate and the binding of the antibody and antigen in series were confirmed by SPR spectroscopy. The surface morphology analyses of the self-assembled protein G layer on the Au substrate, monoclonal antibody (Mab) against E. coli O157:H7 which was immobilized on protein G, and bound E. coli O157:H7 extracts on Immobilized Mab against E. coii O157:H7 were performed by atomic force microscopy (AFM). The detection limit of the SPR-based immunosensor for E. coli O157:H7 was found to be about $10^4$ cells/ml.

Contact Transfer Printing Using Bi-layer Functionalized Nanobio Interface for Flexible Plasmonic Sensing

  • Lee, Jihye;Park, Jiyun;Lee, Junyoung;Yeo, Jong-Souk
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.413-413
    • /
    • 2014
  • In this paper, we present a fabrication method of functionalized gold nanostructures on flexible substrate that can be implemented for plasmonic sensing application. For biomolecular sensing, many researchers exploit unconventional lithography method like nanoimprint lithography (NIP), contact transfer lithography, soft lithography, colloidal transfer printing due to its usability and easy to functionalization. In particular, nanoimprint and contact transfer lithography need to have anti-adhesion layer for distinctive metallic properties on the flexible substrates. However, when metallic thin film was deposited on the anti-adhesion layer coated substrates, we discover much aggravation of the mold by repetitive use. Thus it would be impossible to get a high quality of metal nanostructure on the transferred substrate for developing flexible electronics based transfer printing. Here we demonstrate a method for nano-pillar mold and transfer the controllable nanoparticle array on the flexible substrates without an anti-adhesion layer. Also functionalization of gold was investigated by the different length of thiol applied for effectively localized surface plasmonic resonance sensing. First, a focused ion beam (FIB) and ICP-RIE are used to fabricate the nanoscale pillar array. Then gold metal layer is deposited onto the patterned nanostructure. The metallic 130 nm and 250 nm nanodisk pattern are transferred onto flexible polymer substrate by bi-layer functionalized contact imprinting which can be tunable surface energy interfaces. Different thiol reagents such as Thioglycolic acid (98%), 3-Mercaptopropionic acid (99%), 11-Mercaptoundecanoic acid (95%) and 16-Mercaptohexadecanoic acid (90%) are used. Overcoming the repeatedly usage of the anti-adhesion layer mold which has less uniformity and not washable interface, contact printing method using bi-layer gold array are not only expedient access to fabrication but also have distinctive properties including anti-adhesion layer free, functionalized bottom of the gold nano disk, repeatedly replicate the pattern on the flexible substrate. As a result we demonstrate the feasibility of flexible plasmonic sensing interface and anticipate that the method can be extended to variable application including the portable bio sensor via mass production of stable nanostructure array and other nanophotonic application.

  • PDF