• 제목/요약/키워드: Membrane integrity

검색결과 270건 처리시간 0.028초

S-Nitrosoglutathione (GSNO) Alleviates Lead Toxicity in Soybean by Modulating ROS, Antioxidants and Metal Related Transcripts

  • Methela Nusrat Jahan;Islam Mohammad Shafiqul;Da-Sol Lee;Youn-Ji Woo;Bong-Gyu Mun;Byung-Wook Yun
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2023년도 춘계학술대회
    • /
    • pp.105-105
    • /
    • 2023
  • Heavy metals, including lead (Pb) toxicity, are increasing in soil and are considered toxic in small amounts. Pb contamination is mainly caused by industrialization - smelting, mining. Agricultural practices - sewage sludge, pests and urban practices - lead paint. It can seriously damage and threaten crop growth. Pb can adversely affect plant growth and development by affecting the photosystem, cell membrane integrity, and excessive production of reactive oxygen species (ROS) such as hydrogen peroxide (H2O2)andsuperoxide(O2.-). NO is produced via enzymatic and non-enzymatic antioxidants to scavenge ROS and lipid peroxidation substrates in terms of protecting cells from oxidative damage. Thus, NO improves ion homeostasis and confers resistance to metal stress. Our results here suggest that exogenous NO may aid in better growth under lead stress. These enhancements may be aided by NO's ability in sensing, signaling and stress tolerance in plants under heavy metal stress in combination with lead stress. Our results show that GSNO has a positive effect on soybean seedling growth in response to axillary pressure and that NO supplementation helps to reduce chlorophyll maturation and relative water content in leaves and roots following strong burst under lead stress. GSNO supplementation (200 µM and 100 µM) reduced compaction and approximated oxidative damage of MDA, proline and H2O2. Under plant tension, a distorted appearance was found in the relief of oxidative damage by ROS scavenging by GSNO application. In summary, modulation of these NO, PCS and prolongation of metal past reversing GSNO application confirms the detoxification of ROS induced by toxic metal rates in soybean. In summary, these NO, PCS and metal traditionally sustained rates of reverse GSNO application confirm the detoxification of ROS induced by toxic metal rates in soybean.

  • PDF

Effects of Endocrine Disruptors (NP, DBP and BPA) on Sperm Characteristics and Development of IVF Embryos in Pig

  • Yuh, In Suh;Cheong, Hee Tae;Kim, Jong Taek;Park, In Chul;Park, Choon Keun;Yang, Boo Keun
    • Journal of Animal Science and Technology
    • /
    • 제55권4호
    • /
    • pp.237-247
    • /
    • 2013
  • This study was to examine single or combined in vitro effects of environmental endocrine disruptors on boar sperm characteristics, oxidative stress damage in sperm and development of porcine IVF embryos. Addition of various concentration of NP (10, 20, $30{\mu}M$), DBP (10, 50, $100{\mu}M$) and BPA (1, 5 or $10{\mu}g/ml$) on boar sperm characteristics such as percentages of sperm motility, viability, membrane integrity and mitochondrial activity were dose-dependently decreased within 3, 6 or 9 hr incubation period (p<0.05). The overall detrimental effects increased with incubation time increasement. NP, DBP and BPA showed the detrimental effects on sperm membrane and mitochondria of energy production organelles affecting cell viability with the dependancy of dose and incubation time. In combination effects, NP ($10{\mu}M$) + DBP ($10{\mu}M$) significantly decreased boar general sperm characteristics for 3 or 6 hr incubation period compared with control (p<0.05). When both of NP and DBP concentrations (NP; $30{\mu}M$, DBP; $100{\mu}M$) increase, the detrimental effects on sperm characteristics were larger than those of low concentration combination (p<0.05). The inhibitory effects of NP ($30{\mu}M$) + BPA ($10{\mu}g/ml$) on sperm characteristics were larger than those of NP ($10{\mu}M$) + BPA ($1{\mu}g/ml$) (p<0.05). DBP ($100{\mu}M$) + BPA ($10{\mu}g/ml$) decreased sperm characteristics compared with the low concentration combination (DBP $10{\mu}M$ + BPA $1{\mu}g/ml$, p<0.05). This result indicates the detrimental effects of both chemicals on sperm characteristics were dose dependent. Addition of NP ($30{\mu}M$) + DBP ($100{\mu}M$), NP ($30{\mu}M$) + BPA ($10{\mu}g/ml$), DBP ($10{\mu}M$) + BPA ($1{\mu}g/ml$) or DBP ($100{\mu}M$) + BPA ($10{\mu}g/ml$) significantly increased lipid peroxidation for 3 or 6 hr incubation period (p<0.05) compared with no addition control. NP (${\geq}20{\mu}M$) decreased the percentages of IVF embryo development from morulae and blastocyst stages (p<0.05) and its detrimental effects were dose-dependant. BPA 0, 1, 5 or $10{\mu}g/ml$ decreased significantly and dose-dependently the percentage of morulae plus and blastocysts (p<0.05). Combinations of DBP ($100{\mu}M$) plus NP ($30{\mu}M$) and DBP ($100{\mu}M$) plus BPA ($10{\mu}g/ml$) did not affect on morulae and blastocyst development, but NP ($30{\mu}M$) plus BPA ($10{\mu}g/ml$) has significant detrimental effect on embryo development at these stages (p<0.05). These overall results indicate that the partial detrimental effects on boar sperm characteristics and embryo development by NP, DBP, BPA or the combination of these chemicals might be due to the increasement of lipid peroxidation and free radical formation in the cell and there were no specific interaction effects on boar sperm and embryo degeneration among the combined treatments.

시료 희석 주입 LC-MS/MS를 이용한 소변 중 메스암페타민, 4-하이드록시메스암페타민, 암페타민 및 4-하이드록시암페타민 동시 분석 (Determination of methamphetamine, 4-hydroxymethamphetamine, amphetamine and 4-hydroxyamphetamine in urine using dilute-and-shoot liquid chromatography-tandem mass spectrometry)

  • 허보름;권남희;김진영
    • 분석과학
    • /
    • 제31권4호
    • /
    • pp.161-170
    • /
    • 2018
  • 메스암페타민(methamphetamine, MA)과 암페타민(amphetamine, AP)은 전세계적으로 널리 퍼진합성 흥분제로 보건 및 사회 문제, 경제적 비용 발생 등의 다양한 문제를 일으킨다. 또한 이러한 마약은 중독 및 남용 가능성이 매우 높기 때문에 확산 방지를 위한 방안의 하나로 복용자의 생체시료에서 이들 마약을 검출하기 위한 분석법 개발이 필요하다. 따라서 본 연구에서는 액체크로마토그래피-질량분석법(liquid chromatography-tandem mass spectrometry, LC-MS/MS)를 이용하여 소변에서 MA와 4-하이드록시메스암페타민(4-hydroxymethamphetamine, 4HMA), AP, 4-하이드록시암페타민(4-hydroxyamphetamine, 4HA)을 동시에 분석할 수 있는 분석법을 개발하였고 유효성 평가를 수행하였다. 전처리 시간 단축을 위해 50000 g에서 3 min 동안 초고속원심분리 후 시료 희석 주입법을 이용하여 LC-MS/MS에 주입하였다. 분리관은 역상 C18 컬럼을 사용하였고, 정량분석을 위해 MRM (multiple reaction monitoring) 모드를 적용하였다. 가중계수 $1/x^2$에서 정량 범위는 MA는 10-2500 ng/mL, AP는 1.0-800 ng/mL, 4HA와 4HMA는 2.0-200 ng/mL로 설정하였고, 검량선의 직선성은 결정계수($r^2$)를 구하여 평가하였다. 초고속원심분리법의 효율성을 확인하기 위해 전처리 과정으로 시린지 필터(membrane-filtration)를 적용한 결과와 비교하였고, 그 결과 분석물질에 따라 6-15 % 성능이 우수한 것으로 나타났다. 일내(intra-day)와 일간(inter-day) 정밀도는 6.6 % 미만이었고, 정확도는 -14.9-11.3 % 였다. 최저정량한계(LLOQ)는 2.0 ng/mL (4HA 및 4HMA), 1.0 ng/mL (AP), 10 ng/mL (MA)로 확인되었다. 선택성, 검출한계, 희석무결성, 기질효과, 효율성, 안정성을 평가한 결과 만족스러운 측정값을 얻었다. 또한 개발된 분석법을 마약 복용자의 소변에 적용하여 분석법의 유용성을 확인하였다.

Glycol ethers에 대한 피부 투과 특성 (Characteristics of Percutaneous Absorption of Glycol ethers)

  • 이한섭;최성부;김낙주;근장현;황현석;백정훈;최진호;이호준
    • 한국응용과학기술학회지
    • /
    • 제30권1호
    • /
    • pp.116-126
    • /
    • 2013
  • Glycol ethers는 페인트에 흔히 사용되는 ethylene glycol의 alkyl ethers에 기반을 둔 용제들이다. 이 용제들은 일반적으로 저분자량 에테르와 알코올의 용제 친화적 성질과 더불어 더 높은 비등점을 가지고 있다. Union Carbide Corp.는 "Glycol ethers"를 하나의 미국 상표로 등록했으며, 이는 제약, 자외선차단제, 화장품, 잉크, 염료 및 수성페인트에서 찾아볼 수 있다. 반면 glycol ethers는 그리스 제거제, 세제, 에어로졸 페인트와 접착제에서도 발견된다. 대부분의 glycol ethers는 수용성, 생분해성이며, 아주 적은 수의 glycol ethers만이 유독성이라고 여겨진다. 그러므로 glycol ethers는 환경에 부작용을 낳을 것 같지는 않다. 최근 연구는 glycol ethers에 작업상 노출되는 것이 남성 정자의 저 운동성과 연관이 되어 있다고 제시했지만, 이는 다른 이들에 의해 반박되어지고 있다. 본 연구에서는 3가지 종류의 glycol ethers의 피부침투성에 관해 용제와 세제의 조합을 사용하여 시험관을 통해 연구한다. Methyl glycol ethers, ethyl glycol ethers and butyl glycol ethers의 흡수는 쥐의 피부를 통해 시험관에서 측정되었다. Epidermal membranes는 Franz diffusion cells에 세워졌으며, 그들의 PBS 침투율은 glycol ethers가 epidermal surface에 적용되기 전, 피부의 보전을 위해 처리하였다. 개별 glycol ethers의 흡수율은 최대 흡수 파장(${\lambda}_{max}$)에서 흡광도를 측정하여 결정하였으며, 침투율의 측정은 esters와의 접촉을 이유로 장벽 기능 내 불가역 변화를 정량화하였다. 시험관 실험 결과 glycol ethers의 종류는 methyl glycol ethers > ethyl glycol ethers > butyl glycol ethers의 순에 따라 빠르게 나타났다. 피부침투는 저분자량 피부침투, 친수성과 같은 화학적구조의 차이에서 유익했다. 이는 분배계수와 용해 방법 및 수동확산이 전달이 고려되는 곳에서 속도를 올렸기 때문이다.

Jeju Crossbred Horses 정액 생산 시 Pentoxifylline 농도가 정자 성상에 미치는 영향 (Effect of Pentoxifylline Concentration on Sperm Quality in Jeju Crossbred Horses)

  • 박설화;신상민;양병철;김남영;우제훈;신문철;유지현;손준규
    • 한국수정란이식학회지
    • /
    • 제33권1호
    • /
    • pp.17-22
    • /
    • 2018
  • 본 연구에서는 제주산마의 액상정액 및 동결정액의 성상 개선을 위하여 펜톡시필린 수준을 설정하여 정자의 운동성, 생존율, 정자막 온전성을 평가하였다. 말 동결-융해 정액의 30분 경과 후 정액성상 비교 결과 펜톡시필린 4mM(T1)처리구와 8mM(T2)처리구에서 Progressive Motility(PM)가 $53.25{\pm}2.87$, $50.28{\pm}2.14$$40.09{\pm}5.15$$41.27{\pm}2.82$인 대조구와 16mM(T3)에 유의적으로 높게 나타났으며(p<0.05), Progressive Fast Motility(PFM)도 펜톡시필린 4mM(T1)처리구와 8mM(T2)처리구가 각각 $22.44{\pm}1.62$$ 22.74{\pm}3.07$로 대조구와 16mM(T3) 처리구의 $13.47{\pm}1.48$$14.66{\pm}3.68$ 보다 유의적으로 높게 나타났다(p<0.05). 말 동결-융해 정액의 30분 경과 후 정액성상 비교 결과에서는 총 운동성(Total Motility)에서 T1와 T2가 $68.96{\pm}1.64$$67.90{\pm}6.72$$53.48{\pm}4.84$$58.14{\pm}2.65$인 대조구와 T3에 비해 유의적으로 높은 운동성을 보였다(p<0.05). 이상의 결과를 종합해 볼 때 펜톡시필린 4mM와 8mM를 처리했을 때 대조구보다 정자의 운동성을 증진시키는 효과가 있었으며, 펜톡시필린 16mM 이상의 처리에서는 정자 성상에 좋지 않은 영향을 미치는 것을 확인할 수 있었다. 이러한 결과는 활성산소를 억제하는 효과가 액상정액 보존 과정에서 발생하는 ROS로부터 정자를 안정적으로 보호하는 것으로 판단되며, 동결-융해 정액의 펜톡시필린 처리구 4mM 첨가구에서 다른 처리구보다 융해 후 1시간 동안 총운동성이 약 10%가량 높은 경향을 나타내었다. 펜톡시필린 처리가 동결-융해 후 정자의 운동성을 10% 이상 개선시킨다는 Taylor 등(2013)의 보고와도 비슷한 경향을 보였으며, 펜톡시필린이 동결-융해 후 정자 운동성 향상 등 정자 성상을 개선하는 것으로 판단된다.

2형 당뇨병을 동반한 만성 치주염 환자의 치은조직에서 MMP-2, MMP-8의 발현 양상 비교 (MMP-2, MMP-8 Expression in gingival tissue of Chronic Periodontitis associated to Type 2 Diabetes Mellitus)

  • 강민구;차현정;송선희;박진우;서조영;이재목
    • Journal of Periodontal and Implant Science
    • /
    • 제35권3호
    • /
    • pp.661-674
    • /
    • 2005
  • 치주질환은 치주지지 조직의 상실로 특징 지워지는 감염성 질환으로, 지주조직의 세포외 기질(특히 교원질)이 주요 degradation target이 된다. 현재로서는 MMP family가 주역을 담당하고 있음이 밝혀졌는데, 구강 조직에서 가장 광범위하게 분포하는 것이 MMP-2, MMP-8 이다. 치주조직에서 MMP-2는 주로 결합조직내 섬유아세포와 육아조직에서, 발현되며 , basement membrane의 integrity와 접합상피 부착에 영향을 줄 수 있고, MMP-8은 neutrophils에서 발현되어 다양한 염증세포와 염증진행에 영향을 주는 것으로 알려져 있다. 치주질환에서 MMP-2, MMP-9의 발현 증가는 이미 치은 열구액을 분석한 여러 연구에서 보고 되어 그 발현 수준이 치주질환 진단의 좋은 indicator가 될 수 있음이 시사되었다. 치주질환에서 MMP-2, MMP-8의 발현이 증가하는 것은 주로 P. gingivalis, IL-1과 연계되어 그 기전이 추정되어 왔는데, 이는 2형 당뇨병이 치주 질환의 심도에 영향을 미치는 기전과 많은 부분을 공유한다. 따라서 본 실험에서는 2형 당뇨병 환자와 비당뇨자에서 만성 치주염 부위의 치은, 건강한 치은에서 염증 매개체 중 하나인 MMP-2, MMP-8의 발현에 대해 비교 분석함으로써 염증, 혈당이 미치는 영향을 밝히고 2형 당뇨환자의 만성치주염 치은조직에서 치주조직 파괴의 기전을 연구하고자 하였다. 경북대 병원 치주과 내원 환자중 2형 당뇨병 환자와 비당뇨 환자를 대상으로 여러 가지 환자요소, 임상 치주 상태를 기록하고, 비당뇨 환자의 만성 치주염 부위(n=8, group 1), 비당뇨 환자의 건강한 부위(n=8, group 2), 2형 당뇨병 환자의 만성 치주염 부위(n=8, group 3)에서 각각 변연 치은을 채득하고, 액화 질소에 급속 동결하였다. Western blotting을 이용하여 각 조직 내 MMP-2, MMP-8의 발현을 관찰, densitometer를 이용하여, 상대적 발현을 정량, 각 조직의 ${\beta}-actin$을 이용하여 표준화하여여 실험군들과 대조군들의 평균치를 비교하였다. 그 결과 정상군에 비해 치주 환자군에서 채득된 시편에서 MMP-2, MMP-8의 발현이 증가하였으며, 염증군의 당뇨군과 비당뇨군 사이에서는 2형 당뇨병을 동반한 치주 환자군에서 가장 높게 나타났지만, 통계학적으로 유의한 차이를 나타내지는 않았다(P<0.05). 결론적으로 본 연구에서 2형 당뇨병을 동반한 치주 환자군의 치은 조직에서 정상군과 비당뇨 치주 환자군보다 MMP-2, MMP-8의 발현이 다소 증가하는 양상을 보였다.

콜린의 한국인 영양소 섭취기준 제정 검토를 위한 문헌 고찰 및 향후 과제 (Literature review and future tasks necessary to establish of Korean Dietary Reference Intake for choline)

  • 심유진;박재희;이윤정;박은주
    • Journal of Nutrition and Health
    • /
    • 제55권2호
    • /
    • pp.211-226
    • /
    • 2022
  • 콜린은 세포막의 구조적 완전성, 메틸 대사, 아세틸콜린과 같은 신경전달물질 합성, 세포막 (인지질, phospholipids) 투과 신호전달, 지질 및 콜레스테롤 운반과 대사 등에 있어서 복합적으로 작용하고 있는 중요한 영양 성분이다. 콜린은 체내 합성이 가능하지만 요구량을 만족시키기에 불충분하므로 식사를 통해 섭취해야 한다. 미국/캐나다, 호주/뉴질랜드, 유럽, 중국, 대만 등에서는 콜린 충분섭취량과 상한섭취량이 제정되었으나, 일본은 콜린 데이터베이스가 구축되어 있지 않다는 이유로 콜린 Dietary Reference Intakes (DRI) 제정을 고려하고 있지 않다. 우리나라에서도 2020년 Dietary Reference Intakes for Koreans (KDRI) 제·개정 연구에서 콜린의 제정 여부를 검토하였으나 여전히 우리나라 식품을 대상으로 한 콜린 데이터베이스 구축 연구나 한국인을 대상으로 한 콜린 섭취량 조사 등의 연구가 전혀 이루어지지 않고 있어서 콜린 섭취기준의 제정은 어려운 것으로 판단하였다. 다만 2020년 DRI 개·제정을 위한 준비 작업의 일환으로 콜린 섭취량과 질병발생 가능성을 검증하기 위해 1949년부터 최근까지 보고된 문헌검색, 평가 및 문헌요약 작업을 통해 차후 콜린 DRI 제정을 위한 근거를 마련한 것은 본 사업의 성과라고 볼 수 있을 것이다. 인간을 대상으로 한 RCT, 코호트연구, 환자-대조군 연구 및 단면적 관찰 연구를 통해 충분한 양 (400-500 mg/day)의 콜린섭취는 간기능 손상 (지방간), 신경관손상, 심혈관질환 및 유방암 예방의 효과 및 인지기능 개선과 관계가 있는 것으로 판단되는 반면, 높은 수준의 콜린 섭취가 오히려 전립선암과 상관관계가 있다는 부정적인 연구결과도 있었다. 현재로서는 콜린 섭취와 건강결과와의 상관성을 결론짓기에는 연구결과들이 일관성이 부족하고 매우 제한적이고 더욱이 한국인을 대상으로 한 콜린 섭취와 건강결과와의 관련성을 조사한 논문은 전무한 실정이므로 콜린 DRI 제정을 위해서는 한국인을 대상으로 한 충분한 임상실험 결과가 뒷받침되어야 할 것이다.

합곡(合谷), 삼음교(三陰交) 자침(刺鍼)이 백서(白鼠) 자궁(子宮) 운동(運動) 및 Cyclooxygenase-2 발현(發現)에 미치는 영향(影響) (Effects of HapKok (LI-4) , SamUmGyo (SP-6) Acupuncture on Uterine Motility and Cyclooxygenase-2 Manifestation in Rats)

  • 이병철;이호섭;김경식;이건목;나창수;김정상;황우준
    • Journal of Acupuncture Research
    • /
    • 제17권2호
    • /
    • pp.187-208
    • /
    • 2000
  • By the activation of ovary hormone, many morphological changes occur in the epithelial cell lines and muscle cells in rat uterus. These two cells in uterus are important to the implantation of embryo, maintaining pregnancy and starting parturition. One important change associated with the morphological change of these two cells in uterus is the change on prostaglandin(PG) metabolism. Its presence and synthesis in endometriurn and myometrium in uterus affects estrous cycle and the start of embryo implantation in uterus. It also performs as an important modulator in parturition. So the abnormally weak expression of PG causes difficulty during labor and over-expression causes pre-term labor. PG biosynthesis starts from either free or liberated arachidonic acids from membrane phospholipid by phospholipase. Such arachidonic acids are converted into PG catalyzed by Cyclooxygenase. Under normal physiological condition, Cyclooxygenase-1(COX-1) having 602 units of amino acids controls the synthesis of PG. It acts as a local hormone regulating vasomodulation of blood flow, flexible muscle movement, increasing the blood permeability and contributing the protective role in preserving integrity of the stomach lining and Cyclooxygenase-2 (COX-2) is induced by the inflammation, pregnancy and increased its expression until parturition. Lipid metabolite like PG is located in uterine and expression of COX-2 increased with pregnancy. Increased expression of COX proteins in epithelial cells and myometrial cells are told to increase the muscle contractility in uterus but decreased right after the labor in rat. It is a good sign indicating that COX proteins are deeply related to the start of labor. Currently, Several studies report the use of PG and COX-2 inhibitor as medication for controlled abortion or to prevent pre-term labor but they entail various side-effects. Our study proposed to suggest use of acupuncture as an another mediator to control abortion or pre-term labor without causing unnecessary side-effects by those medicines. Two acupuncture sites, LI-4 & SP-6 were selected due to their known efficacy. From the immunohistochemical staining of COX-2, normal expression of COX-2 protein in nonpregnant SD rat's uterus revealed that COX-2 protein was primarily detected in the lumina epithelial lining and in the epithelial cell lining contacting the stromal cells. High resolution optical microscopic scanning revealed distinguishable staining in the myometrial mucosa. LI-4 acupuncture administered nonpregnant rat's uterus showed strong expression for COX-2 in endometrium contacted with lumina epithelial lining of rat uterus and in myometrial mucosa. Stromal cells showed more staining than untreated nonpregnant rat's uterus and stronger staining in stromal cells contacting myometrial layer compared to untreated nonpregnant rat's uterus. SP-6 acupuncture administered nonpregnant rat's uterus showed weak expression for COX-2 in myometrial layers and stromal cells but no staining was visible in lumina epitheliai and glandular epithelial cells. Few stromal cells and myometrial mucosa were positively stained for COX-2. Pregnant SD rat's uterus was also immunostained for COX-2 expression after 18 days of pregnancy. Unlike to untreated nonpregnant rat's uterus, luminal epithelial cells were not positively stained for COX-2 but stronger staining for COX-2 was revealed in stromal cells. LI-4 acupunctured SD rat's uterus had very strong expression of COX-2 in luminal epithelial lining. Few stromal cells showed stronger positive COX-2 staining and myometrial layers also showed more expression than untreated pregnant rat. SP-6 acupuncture administered pregnant SD rat's uterus showed positive expression of COX-2 in epithelial cells of luminal mucosa layer but weaker than that of LI-4 acupuncture treatment's case. However, strong positive staining was revealed in stromal mucosa and myometrial layers. Virgin SD rat's uterus motility index during LI-4 acupuncture was 66.52 % (Prob〉T = 0.0197) compared to its motility before the acupuncture treatment but the motility index was slighdy elevated up to 79.58 % (Prob〉T = 0.1175) after the acupuncture. During the SP-6 acupuncture treatment for 30 minutes, uterus motility index was 90.52 % (Prob〉T = 0.1832) showing lesser decrement but consequently reached similar motility index decreasal to 79.95 % (Prob〉T = 0.0215) after the acupuncture treatment as LI-4 showed. LI-4 acupuncture tend to be a quick treatment to reducing the uterus motility in a virgin rat but eventually both two acupuncture administration created very similar reduction of uterus motility seeing the index after the both acupunctures. The uterus movement monitored during the LI-4 acupuncture administered for 30 minutes, Pregnant SD rat showed decreased motility down to 77.90 % (Prob〉 T = 0.0076) compared to uterus motility before the acupuncture and it continuously decreased down to 71.81 %(Prob〉T = 0.0214) after the removal of needle. The statistical analysis using paired t-test showed significance difference for both two motility indexs at =0.05. SP-6 acupuncture administered to pregnant SD rat also had similar pattern of decreasing uterus motility index down to 74.70 % (Prob〉T = 0.1730) during the initial 30 minutes acupuncture administration and it was continuously lowered to 71.52 % (Prob〉T = 0.0155) after the acupuncture. The paired t-test resuit for SP-6 suggest prompt response of uterus motility index to the SP-6 acupuncture treatment but consequently reached same level of inducing the motility reduction as LI-4 at =0.05 level.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF