• 제목/요약/키워드: Membrane Module

검색결과 347건 처리시간 0.024초

Study of the ageing of hollow fibers in an industrial module for drinking water production

  • Wang, S.;Wyart, Y.;Perot, J.;Nauleau, F.;Moulin, P.
    • Membrane and Water Treatment
    • /
    • 제4권1호
    • /
    • pp.53-67
    • /
    • 2013
  • In this study, ageing characteristics of an industrial hollow-fiber membrane module were investigated after 50 months of drinking water production. For this purpose, the industrial module was opened to make 18 smaller modules with hollow-fibers taken from different parts of the industrial module. These modules were probed by the use of a magnetic nanoparticle (NP) challenge test based on magnetic susceptibility (K) measurement of permeate. No magnetic susceptibility was detected in permeate when the challenge test was performed on an intact membrane module, indicating the complete retention of nanoparticles by the membrane. The compromised membrane module can be successfully detected by means of magnetic susceptibility measurement in permeate. So, this study clearly demonstrates that ageing of ultrafiltration membranes can be monitored by measuring the magnetic susceptibility of permeate from an ultrafiltration membrane module. These results showed that the hollow fibers in the center zones of the bundle would age faster than those in the outer zones around the bundle. This result is in agreement with numerical simulation (Daurelle et al. 2011).

응집-여과-중화 공정에 의해 전처리된 아크릴 폐수의 한외여과와 역삼투 모듈 조합 공정에의 적용 (Application in Ultrafiltration and Reverse Osmosis Module Set with Acrylic Wastewater Pretreated by Coagulation-Filtration-Neutralization Process)

  • 이광현;강병철;이종백
    • 멤브레인
    • /
    • 제18권1호
    • /
    • pp.1-6
    • /
    • 2008
  • 아크릴 폐수를 응집-여과-중화의 전처리 공정에 적용하여 막오염 인자를 최소화 한 후 UF/RO 공정에 적용하였다. 막의 형태 및 종류에 따라 한외여과 및 역삼투 모듈을 조합을 이루어 전처리 수를 온도 및 압력변화에 따라 적용하여 분리 특성을 고찰하였다. 투과 플럭스는 모듈 set 1의 UF모듈보다 모듈 set 4의 UF모듈의 투과량이 약 $2{\sim}3$배 더 많이 배출됨을 확인하였다. 최종적인 투과량은 관형모듈과 조합을 이룬 모듈 set 2와 모듈 set 3이 좋은 결과를 나타내었다. 모든 UF 모듈에서 TDS, T-N 및 COD의 제거 효율은 온도 및 압력변화에 영향을 받지 않고 제거 효율 또한 낮음을 알 수 있었다. RO모듈에서 TDS, T-N 및 COD가 우수한 제거 효율을 보였다. 아크릴 폐수의 최종적인 수질결과는 공장폐수의 배출 허용기준을 만족하였고, 막모듈 조합은 폐수의 재활용 가능성을 확인할 수 있었다.

자연대류 불안정 흐름에 의해 투과량을 증가시킨 전량여과 막모듈의 설계 (Design of Dead-end Membrane Module with Increased Permeate Flux by Natural Convection Instability Flow)

  • 김기준;염경호
    • 멤브레인
    • /
    • 제29권3호
    • /
    • pp.147-154
    • /
    • 2019
  • BSA 단백질 용액의 전량 막여과에서 상용(commercial) 막모듈의 경사각 변화에 따라 발생된 자연대류 불안정 흐름(NCIF)의 투과 플럭스 증가 효과를 측정한 결과, 막모듈의 경사각이 $0^{\circ}$에서 $180^{\circ}$로 증가하면 NCIF 발생이 커져 플럭스가 증가하였다. 그러나 상용 막모듈은 모듈 내에 존재하는 공기층을 완전히 제거해야 NCIF를 발생시킬 수 있다. 본 연구에서 설계 제작된 custom design 막모듈은 crossward 방향($90^{\circ}$)으로 막투과가 이루어져 모듈 상부에 공기층이 존재하더라도 항상 NCIF가 발생된다. Custom design 막모듈에서 BSA와 dextran 용액의 막여과 실험을 수행한 결과, NCIF의 발생으로 2시간 조작 시 BSA 용액의 경우 약 3.8배, dextran 용액의 경우 약 1.8배까지 투과 플럭스가 증가하였다. 또한 BSA 용액을 대상으로 한 20시간의 조작에서도 NCIF의 발생이 지속되어 플럭스가 약 7.5배까지 증가하였다. 본 연구에서 설계된 막모듈은 항상 NCIF가 발생되므로 막오염 형성 억제에 따른 투과 플럭스 증가를 기대할 수 있어 전량여과 막모듈로서의 활용성이 있음을 확인하였다.

분리막 하우징용 복합소재의 연구개발 동향 (Development Trend of Composite Materials for Membrane Hosuing)

  • 김득주;남상용
    • 멤브레인
    • /
    • 제26권1호
    • /
    • pp.14-25
    • /
    • 2016
  • 분리막 시스템은 기존의 분리공정과 비교하여 우수한 효율과 낮은 가격으로 인하여 빠르게 성장하고 있다. 분리막 공정은 분리막, 모듈, 그리고 기계적 요소로 구성되어 있으며 향상된 효율을 얻기 위하여 분리막 공정에 사용되는 소재의 요구사항 또한 증가가 되고 있다. 분리막 모듈은 분리막 시스템의 핵심 요소 중 하나로써 최근 들어 복합 소재들이 스테인레스강 모듈과 비교하여 우수한 물성과 낮은 가격으로 인해 분리막 하우징에 적용되어 왔다. 본 리뷰에서는 다양한 종류의 유리섬유와 이를 이용한 복합소재들에 대하여 정리하였으며 분리막 시스템에 적용을 위한 잠재성에 대하여 논의하였다.

침지형 막모듈에서 중공사 분산에 따른 여과특성 (Filtration Characteristics according to Hollow Fiber Dispersion in Submerged Membrane Module)

  • 이재인;신춘환
    • 한국환경과학회지
    • /
    • 제9권2호
    • /
    • pp.173-176
    • /
    • 2000
  • This study was carried out to investigate the filtration characteristics of membrane modules according to hollow fiber dispersion for direct solid-liquid separation of activated sludge. 2 bundle, 4 bundle, and 10 bundle, and 10 bundle module used in this experiment according to hollow fiber dispersion was manufactured at laboratory and permeate flux and transmembrane pressure(TMP) of each module were observed under a suction pressure of 0.5kgf/c$m^2$. As the hollow fibers were dispersed, permeate flux was increased and TMP was decreased. Permeate flux and TMP of each module was 15.0 $\ell$/$m^2$.h and 31.8 cmHg for 2 bundle, 16.0 $\ell$/$m^2$ .h and 17.4 cmHg for 4 bundle, and 20.4 $\ell$/m2 .h and 31.8 cmHg for 10 bundle. In conclusion, the membrane fouling is expected to be decrease by maintaining lower TMP with hollow fiber dispersion.

  • PDF

PVDF 중공사 분리막을 이용한 MD 모듈 구조 및 운전 조건에 따른 플럭스 영향 평가 (Evaluation of the Flux According to Membrane Distillation Module Structure and Operating Conditions Using PVDF Hollow Fiber Membrane)

  • 민지희;이슬기;길남석;박민수;김진호
    • 멤브레인
    • /
    • 제28권2호
    • /
    • pp.83-89
    • /
    • 2018
  • 열유도상분리법(TIPS) 및 연신의 복합공정으로 막증류(Membrane distillation, MD)용의 소수성 및 다공성 PVDF 중공사 분리막을 제조하였다. 제조된 분리막을 막증류 공정에 적용하여 처리수량을 극대화하기 위한 방안으로 모듈의 형태와 운전조건 및 병렬 연결 시 배관의 크기 영향을 확인하고자 하였다. 진공 막증류 모듈의 최적화 실험에서는 모듈 내 분리막의 충진율과 길이가 증가할수록 플럭스는 감소하며, 진공포트의 위치는 모듈을 수직으로 연결하였을 때 원수의 inlet 방향에 위치할수록 플럭스 측면에서 가장 유리한 것으로 확인되었다. 모듈의 헤더배관의 크기선정에서는 중공사막의 내경면적과 헤더배관의 내경면적이 동일할 경우 최대 플럭스를 나타냄을 확인할 수 있었으며, 모듈 내 선속도가 높을수록 높은 플럭스를 나타내지만 모듈에 작용하는 압력 역시 비례하여 증가하기 때문에 최적 선속도를 찾는 것이 필요하다.

Application of tube-type ceramic microfiltration membrane for post-treatment of effluent from biological wastewater treatment process using phase separation

  • Son, Dong-Jin;Kim, Woo-Yeol;Yun, Chan-Young;Kim, Dae-Gun;Chang, Duk;Sunwoo, Young;Hong, Ki-Ho
    • Environmental Engineering Research
    • /
    • 제22권4호
    • /
    • pp.377-383
    • /
    • 2017
  • A tube-type ceramic membrane for microfiltration was developed, and the membrane module comprised of three membranes was also applied to biological carbon and nitrogen removal processes for post-treatment. Manufacturing the microfiltration membrane was successful with the structure and boundary of the coated and support layers within the membrane module clearly observable. Total kjeldahl nitrogen removal from effluent was additionally achieved through the elimination of solids containing organic nitrogen by use of the ceramic membrane module. Removal of suspended solids and colloidal substances were noticeably improved after membrane filtration, and the filtration function of the ceramic membrane could also easily be recovered by physical cleaning. By using the ceramic membrane module, the system showed average removals of organics, nitrogen, and solids up to 98%, 80% and 99.9%, respectively. Thus, this microfiltration system appears to be an alternative and flexible option for existing biological nutrient removal processes suffering from poor settling performance due to the use of a clarifier.

VMD 모듈의 열성능 특성 연구 (A Study on the Thermal Characteristics of Vacuum Membrane Distillation Module)

  • 주홍진;양용우;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제34권5호
    • /
    • pp.23-31
    • /
    • 2014
  • This study was accomplished to get the foundation design data of VMD(Vacuum Membrane Distillation) system for Solar Thermal VMD plant. VMD experiment was designed to evaluate thermal performance of VMD using PVDF(polyvinylidene fluoride) hollow fiber hydrophobic membranes. The total membrane surface area in a VMD module is $5.3m^2$. Experimental equipments to evaluate VMD system consists of various parts such as VMD module, heat exchanger, heater, storage tank, pump, flow meter, micro filter. The experimental conditions to evaluate VMD module were salt concentration, temperature, flow rate of feed sea water. Salt concentration of feed water were used by aqueous NaCl solutions of 25g/l, 35g/l and 45g/l concentration. As a result, increase in permeate flux of VMD module is due to the increasing feed water temperature and feed water flow rate. Also, decrease in permeate flux of VMD module is due to increasing salinity of feed water. VMD module required about 590 kWh/day of heating energy to produce $1m^3/day$ of fresh water.

모델모사를 이용한 막모듈 연결 및 배열이 투과증발 막성능에 끼치는 영향에 관한 연구 (Study on the Effect of Membrane Module Configuration on Pervaporative Performance through Model Simulation)

  • 염충균;윤석복;박유인
    • 멤브레인
    • /
    • 제18권4호
    • /
    • pp.294-305
    • /
    • 2008
  • 본 연구는 공정모사를 통해서 막모듈 배열 및 연결과 막모듈 내에서 공급 잔류액의 온도 변화가 투과증발 공정에 끼치는 영향을 관찰하였으며 이를 위해서 기본 막모듈이 직렬 혹은 병렬로 연결되어 있는 모듈들의 조합을 통한 투과탈수공정을 예측할 수 있는 모델식들을 확립하였다. 에탄올/물 혼합물을 모델 혼합물로 사용하였고 모델식들에 포함되어 있는 투과 파라메타들을 직접 실험에 의해 구하여 사용함으로써 모사의 현실성을 높였다. 모사를 통해서 모듈의 배열방식, 모듈 단의 갯수와 단사이의 공급액의 재가열등의 중요성을 검토하였다.

파일럿 규모 막 증발 공정 적용을 위한 직접 접촉식 모듈의 투과유속 및 열에너지 이동에 관한 연구 (A Study on the Flux and Heat Transfer of Direct Contact Type Module Applied for a Pilot Scale Membrane Distillation Process)

  • 김승환;김세운;이동우;조진우
    • 상하수도학회지
    • /
    • 제31권3호
    • /
    • pp.229-236
    • /
    • 2017
  • In this study, a direct contact membrane module was manufactured to be used in a pilot scale membrane distillation process to treat $3m^3/day$ of the digestate produced from anaerobic digestion of livestock manure. In order to investigate the performance of the membrane module, permeate flux was measured with and without spacer inside the module under various condition of temperature difference and cross flow velocity (CFV) through the membrane surfaces. Flux recovery rate after chemical cleaning was also investigated by applying three different cleaning methods. Additionally, thermal energy consumption was theoretically simulated based on actual pilot plant operation conditions. As results, we observed flux of the module with spacer was almost similar to the theoretically predicted value because the installation of spacer reduced the channeling effect inside the module. Under the same operating condition, the permeate flux also increased with increasing temperature difference and CFV. As a result of chemical in-line cleaning using NaOCl and citric acid for the fouled membranes, the recovery rate was 83.7% compared to the initial flux when NaOCl was used alone, and 87% recovery rate was observed when only citric acid was used. However, in the case of using only citric acid, the permeate flux was decreased at a rapid rate. It seemed that a cleaning by NaOCl was more effective to recover the flux of membrane contaminated by the organic matter as compared to a cleaning by citric acid. The total heat energy consumption increased with increasing CFV and temperature difference across the membrane. Thus, further studies should be intensively conducted to obtain a high permeate flux while keeping the energy consumption to a minimum for a practical application of membrane distillation process to treat wastewater.