• 제목/요약/키워드: Medium-voltage motor drive

검색결과 18건 처리시간 0.028초

Hybrid-Boost Modular Multilevel Converter-Based Medium-Voltage Multiphase Induction Motor Drive for Subsea Applications

  • Daoud, Mohamed;Elserougi, Ahmed;Massoud, Ahmed;Bojoi, Radu;Abdel-Khalik, Ayman;Ahmed, Shehab
    • Journal of Power Electronics
    • /
    • 제19권3호
    • /
    • pp.714-726
    • /
    • 2019
  • This paper proposes a hybrid-boost Modular Multilevel Converter (MMC) for the Medium-Voltage (MV) Variable Speed Drives (VSDs) employed in subsea applications, such as oil and gas recovery. In the presented architecture, a hybrid-boost MMC with a reduced number of semiconductor devices driving a multiphase Induction Machine (IM) is investigated. The stepped output voltage generated by the MMC reduces or eliminates the filtering requirements. Moreover, the boosting capability of the proposed architecture eliminates the need for bulky low-frequency transformers at the converter output terminals. A detailed illustration of the hybrid-boost MMC operation, the expected limitations/constraints, and the voltage balancing technique are presented. A simulation model of the proposed MV hybrid-boost MMC-based five-phase IM drive has been built to investigate the system performance. Finally, a downscaled prototype has been constructed for experimental verification.

Analysis of Cascaded H-Bridge Multilevel Inverter in DTC-SVM Induction Motor Drive for FCEV

  • Gholinezhad, Javad;Noroozian, Reza
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.304-315
    • /
    • 2013
  • In this paper, analysis of cascaded H-bridge multilevel inverter in DTC-SVM (Direct Torque Control-Space Vector Modulation) based induction motor drive for FCEV (Fuel Cell Electric Vehicle) is presented. Cascaded H-bridge multilevel inverter uses multiple series units of H-bridge power cells to achieve medium-voltage operation and low harmonic distortion. In FCEV, a fuel cell stack is used as the major source of electric power moreover the battery and/or ultra-capacitor is used to assist the fuel cell. These sources are suitable for utilizing in cascaded H-bridge multilevel inverter. The drive control strategy is based on DTC-SVM technique. In this scheme, first, stator voltage vector is calculated and then realized by SVM method. Contribution of multilevel inverter to the DTC-SVM scheme is led to achieve high performance motor drive. Simulations are carried out in Matlab-Simulink. Five-level and nine-level inverters are applied in 3hp FCEV induction motor drive for analysis the multilevel inverter. Each H-bridge is implemented using one fuel cell and battery. Good dynamic control and low ripple in the torque and the flux as well as distortion decrease in voltage and current profiles, demonstrate the great performance of multilevel inverter in DTC-SVM induction motor drive for vehicle application.

위치센서없는 영구자석 매입형 전동기의 기동 방식 (Starting Method of BLDC Motor from Standstill to Medium Speed Without any Position Sensor)

  • 이준환;김태덕
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 추계학술대회 논문집
    • /
    • pp.1-4
    • /
    • 2004
  • From standstill to medium speed which enough to sensing back EMF, it is not easy to drive without additional equipments due to directly proportional to flux. Conventional method to drive is 'align and go' method, so called v/f control that is increased voltage duty in proportion to the increase of frequency. Because it isn't consider load of motor and doesn't know rotor position exactly, current is supplied too much current or not enough to rotate motor. This paper is proposed starting method without any poison sensor and can drive a BLDC motor from standstill to the medium speed smoothly without any rattling and time delay compared with the conventional starting algorithm. To verify algorithm of this paper, experimental results are presented.

  • PDF

3.3kV(105A) COMPACT RACK TYPE 고압 인버터 시스템의 방열 성능 향상을 위한 열유동 해석 (THERMAL-FLUID ANALYSIS FOR COOLING PERFORMANCE IMPROVEMENT OF 3.3KV(105A) COMPACT RACK TYPE MEDIUM VOLTAGE INVERTER SYSTEM)

  • 김선영;김성대;유성열;유남규;김태범;홍찬욱;고한서
    • 한국전산유체공학회지
    • /
    • 제19권3호
    • /
    • pp.24-28
    • /
    • 2014
  • With ever rising concerns about saving of fossil fuel resource, there have been an increasing demand for use of energy more efficiently. The electric motor driven inverters can be a great help to improve energy efficiency. They are also used to control the motor speed to the actual need. Therefore the use of them can lead to reduce energy consumption. In particular, the medium voltage(MV) drive systems used for pumps, fans, steel rolling mills and tractions have widespread applications in the industry. They cover power ratings from 0.4MW to 40MW at the MV level of 2.3kV to 13.8kV. The majority of the installed MV drive systems however, are in the 1MW to 4MW range with voltage rating from 3.3kV to 6.6kV. But they are required to reduce size and weight like other power electronic equipments. In this paper, we studied on the 3.3kV(105A) compact rack type inverter system for improving the cooling efficiency. At first, we confirmed the tendency of temperature with computational simulation using ANSYS ICEPAK and actual experimental tests. And then we researched thermal performance improvement designs in order to reduce temperature of the transformer for the safe operation. It can reduce temperature of transformer that using pipe type flow guide in the system. As a result, we found out more efficient solution by thermal-fluid analysis.

PID Controller Tuning using Co-Efficient Diagram method for Indirect Vector Controlled Drive

  • Durgasukumar, G.;Rama Subba Redddy, T.;Pakkiraiah, B.
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1821-1834
    • /
    • 2017
  • Medium voltage control applications due to obtain better output voltage and reduced electro-magnetic interference multi level inverter is used. In closed loop control with inverter, the PI controller does not operate satisfactorily when the operating point changes. This paper presents the performance of Co-Efficient diagram PI controller based indirect vector controlled induction motor drive fed from three-level inverter under different operating conditions (dynamic and steady state). The proposed Co-Efficient diagram PI controller based three level inverter significantly reduces the torque ripple compared to that of conventional PI controller. The performance of the indirect vector controlled induction motor drive has been simulated at different operating conditions. For three-level inverter control, a simplified space vector modulation technique is implemented, which reduces the coordinate transformations complications in the algorithms. The performance parameters, torque ripple contents and THD of induction motor drive with three-level inverter is compared under different operating conditions using CDM-PI and conventional PI controllers.

800MW 가스발전소의 모터 설비에 고압 드라이브를 적용한 사례 (Application of medium-voltage drive to motor equipment of 800MW gas power plant.)

  • 김경수;오현석;박종제;전재현;박철현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.424-425
    • /
    • 2018
  • In the introduction, this paper introduces LS Industrial Systems' medium-voltage drive installed at Hyundai Green Power, an 800MW gas power plant. In the body, it explains the synchronous transfer technology and new speed search technology applied to Forced Draft(FD) Fan and Boiler Feed-water(BF) Pump, which are power generation facilities. Lastly, it shows the annual energy saving amount and operation status which are applied to each facility and proves that it is a successful application case.

  • PDF

Selection of Voltage Vectors in Three-Level Five-Phase Direct Torque Control for Performance Improvement

  • Tatte, Yogesh N.;Aware, Mohan V.
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2162-2172
    • /
    • 2016
  • This paper presents a Direct Torque Control (DTC) strategy for the five-phase induction motor driven by a three-level five-phase inverter in order to improve the performance of the five-phase induction motor. In the proposed DTC technique, only 22 voltage vectors out of 243 available voltage vectors in a three-level five-phase inverter are selected and are divided in 10 sectors each with a width of $36^{\circ}$. The four different DTC combinations (DTC-I, II, III and IV) for a three-level five-phase induction motor drive are investigated for improving the performance of five-phase induction motor. All four of the DTC strategies utilize a combination of the same large and zero voltage vectors, but with different medium voltage vectors. Out of these four techniques, DTC-II gives the best performance when compared to the others. This DTC-II technique is analyzed in detail for improvements in the performance of five-phase induction motor in terms of torque ripple, x-y stator flux and Total Harmonics Distortion (THD) of the stator phase current when compared to its two-level counterparts. To verify the effectiveness of the proposed three-level five-phase DTC control strategy, a DSP based experimental system is build. Simulation and experimental results are provided in order to validate the proposed DTC technique.

패턴인식 기법을 이용한 유도전동기 구동용 전압형 인버터의 고장진단 (Fault Diagnosis of Voltage-Fed Inverters Using Pattern Recognition Techniques for Induction Motor Drive)

  • 박장환;박성무;이대종;김동화;전명근
    • 조명전기설비학회논문지
    • /
    • 제19권3호
    • /
    • pp.75-84
    • /
    • 2005
  • 유도전동기 구동시스템의 예상치 않은 고장은 많은 산업 응용분야에서 심각한 문제를 초래시킬 수 있으므로, 유도전동기 구동을 위한 전압형 PWM 인버터의 고장진단에 대해 연구한다. 진단의 고려 대상은 정류기 다이오드, 스위칭 장치 및 입력단의 개방회로 고장이며, 진단신호는 전동기 전류로부터 유도한다. 고장의 특징추출은 dq-전류 경로의 크기를 이용하였고, 진단은 PCA와 LDA를 적용한다. 또한, 본 논문에서는 일반적인 중${\cdot}$소형 유도전동기 구동 시스템의 제어기에 진단 소프트웨어를 추가하여 사용하는 것에 대한 가능성을 제시하며, 그에 관련해 수행속도에 따른 진단결과들을 보여준다. 최종적으로, MATLAB을 이용하여 인버터의 고장진단에 대한 모의실험을 수행 하였고, 제안된 알고리즘의 유용성을 검증하였다.

H-브릿지 멀티레벨 인버터의 전압 지연 해석 및 전류 제어 보상 (Analysis of Voltage Delay and Compensation for Current Control in H-Bridge Multi-Level Inverter)

  • 박영민;유한승;이현원;정명길;이세현
    • 전력전자학회논문지
    • /
    • 제15권1호
    • /
    • pp.43-51
    • /
    • 2010
  • 본 논문에서는 고전압 전동기 가변속 장치인 H-브릿지 멀티레벨(H-Bridge Multi-Level; HBML) 인버터를 이용한 유도 전동기 벡터 제어시 인버터의 출력 전압 위상 지연 현상을 해석하고 전류 제어기의 보상 기법을 제시하였다. Phase-Shifted Pulse Width Modulation (PSPWM) 기법을 적용한 HBML 인버터는 개별 인버터 모듈이 독립적으로 동작할 수 있어서 확장성과 모듈화 능력이 향상되는 장점이 있다. 그러나 이러한 PSPWM을 적용한 HBML 인버터는 기준 전압과 실제 전압 사이에 위상 차이가 있기 때문에 출력 주파수에 대한 샘플링 주파수의 비율이 충분하지 않은 고속 영역에서 전류 제어기를 불안정하게 하는 원인이 된다. 전류 제어기의 불안정성은 기준 전압과 출력 전압의 위상 차이를 보상하는 제안된 방법을 추가함으로써 제거하였다. 본 방법은 인버터의 스위칭 주파수가 낮고, 전동기 속도가 높은 조건에서 PSPWM을 이용한 HBML 인버터 시스템에 효과적이며, 13레벨로 구성된 HBML 인버터로 구동되는 6,600[V] 1,400[kW] 유도전동기 실험을 통해 제안된 방법의 타당성을 입증하였다.

대용량 모터드라이브 적용을 위한 새로운 이중접속방식의 멀티스텝 인버터 (New Double-Connected Multi-Step Inverter for High Power Motor Drive Applications)

  • 양승욱;최규하;목형수
    • 전력전자학회논문지
    • /
    • 제11권3호
    • /
    • pp.209-215
    • /
    • 2006
  • 본 논문에서는 전압원 인버터의 출력전압 파형을 개선하여 PWM방식을 사용할 수 없는 중 대용량급 모터드라이버 및 UPS, STATCOM, SVC등에 적용하기 위한 새로운 3상 전압원 24-스텝 인버터를 제안한다 보조회로로서 사용한 컨버터로 리플전압을 발생시키고 이를 기존의 12-스텝 인버터에 주입하는데 한대의 링크를 사용하면 12-스텝 동작이 24-스텝으로 전환되며 보조 변압기의 1차 권선을 2N(N=1,2,3...)으로 늘리면 12M-스텝(M=2,3,4..)으로 전환된다. 본 방식의 타당성을 실험 및 시뮬레이션을 통하여 입증하였다.