• 제목/요약/키워드: Medium-High Operating Temperature

검색결과 31건 처리시간 0.024초

중온 작동 범위에서의 슬랩윅 히트파이프 성능에 관한 실험 연구 (An Experimental Study of a Slab Wick Heat Pipe for Medium-high Operating Temperatures)

  • 정복원;부준홍;곽희열
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1630-1637
    • /
    • 2002
  • A slab-wick heat pipe was fabricated and tested for applications where the condenser temperature is in a range of 80 to 12$0^{\circ}C$. The pipe material was 9.53 mm O.D. copper tube and the working fluids were ethanol and water. The total length of the heat pipe was 1.6 m, in which evaporator section was 1.4 m and the condenser was 0.10 m. The slab was a composite wick structure fabricated with STS316 wire screens. Thermal load was varied for a specified fill charge ratio and inclined angle. The optimum fill charge ratio was identified to be 110% based on a theoretical calculation of the pore space in the slab wick of the heat pipe. The maximum thermal load was 120W for ethanol and the same was 200W for water with the condenser temperature of 8$0^{\circ}C$. The thermal performance of the slab wick heat pipe is analysed in terms of temperature characteristics and thermal resistance against thermal load, tilt angle and fill charge ratio.

물-에탄올 혼합물을 작동유체로 하는 진공관형 태양열 집열기용 히트파이프의 작동특성 (Performance Characteristics of a Heat Pipe Having Water-Ethanol Mixture as Working Fluid for Evacuated Solar Collectors)

  • 정의국;부준홍;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제28권5호
    • /
    • pp.78-84
    • /
    • 2008
  • Heat pipes are considered to be promising candidates to enhance the heat transport capability of evacuated solar collectors in a wide temperature range. The working fluid must be selected properly considering various operating conditions of heat pipes for medium-high temperature range to avoid dry-out, local overheating, and frozen failure. The advantage of using binary mixture as heat pipe working fluid is that it can extend operating temperature range of the system as it can overcome operating temperature limit of a single fluid. Various operating temperature ranges were imposed in the experiments to simulate the actual operation of solar collectors using water-ethanol binary mixture. Tests were conducted for the coolant temperature range of -10$^{\circ}C$ to 120$^{\circ}C$, and mixing ratio range was from 0 to 1 based on mass fraction.

Optimization of the Performance of Microbial Fuel Cells Containing Alkalophilic Bacillus sp.

  • CHOI, YOUNGJIN;JOOYOUNG SONG;SEUNHO JUNG;SUNGHYUN KIM
    • Journal of Microbiology and Biotechnology
    • /
    • 제11권5호
    • /
    • pp.863-869
    • /
    • 2001
  • A systematic study of microbial fuel cells comprised of alkalophilic Bacillus sp. B-31 has been carried out under various operating conditions. A significant amount of electricity was generated when redox mediators were used. Among the phenothiazine-type redox dyes tested, azure A was found to be the most effective both in maintaining a high cell voltage and for the long-term operation. The maximum efficiency was and for the long-term operation. The maximum efficiency was obtained at ca. $50^{\circ}C$ giving an open circuit voltage of 0.7V. A small change in temperature did not significantly affect the cell performance, but a rapid decrease in performance was observed below $20^{\circ}C$ and above $70^{\circ}C$. It was noticeable that fuel cell efficiency and discharge pattern depended strongly on the carbon source used in the initial culture medium. Regardless of the initial carbon sources, only glucose and trehalose were utilized as substrates. Galactose, however, was not substantially utilized except when galactose was used in the initial medium. Glucose, in particular, showed $87\%$ coulombic efficiency, which was the highest value ever reported, when Bacillus sp. was cultured in a maltose-containing medium. This study demonstrates that highly efficient microbial fuel cells can be constructed with alkalophilic microorganisms by fine-tuning the operating conditions and by carefully selecting carbon sources in the initial culture medium.

  • PDF

Loss Analysis and Comparison of High Power Semiconductor Devices in 5MW PMSG MV Wind Turbine Systems

  • Lee, Kihyun;Suh, Yongsug;Kang, Yongcheol
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1380-1391
    • /
    • 2015
  • This paper provides a loss analysis and comparison of high power semiconductor devices in 5MW Permanent Magnet Synchronous Generator (PMSG) Medium Voltage (MV) Wind Turbine Systems (WTSs). High power semiconductor devices of the press-pack type IGCT, module type IGBT, press-pack type IGBT, and press-pack type IEGT of both 4.5kV and 6.5kV are considered in this paper. Benchmarking is performed based on the back-to-back type 3-level Neutral Point Clamped Voltage Source Converters (3L-NPC VSCs) supplied from a grid voltage of 4160V. The feasible number of semiconductor devices in parallel is designed through a loss analysis considering both the conduction and switching losses under the operating conditions of 5MW PMSG wind turbines, particularly for application in offshore wind farms. This paper investigates the loss analysis and thermal performance of 5MW 3L-NPC wind power inverters under the operating conditions of various power factors. The loss analysis and thermal analysis are confirmed through PLECS Blockset simulations with Matlab Simulink. The comparison results show that the press-pack type IGCT has the highest efficiency including the snubber loss factor.

Medium Voltage HTS Cable Thermal Simulation using PSCAD/EMTDC

  • Jung, Chaekyun;Kang, Yeonwoog;Kang, Jiwon
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.145-150
    • /
    • 2015
  • This paper described the medium voltage high temperature superconducting cable thermal simulation and its application. New simulation method for HTS cable modeling using PSCAD/EMTDC is introduced in this paper. The developed simulation method consists of electrical model part and thermal model part. In electrical model part, power loss and thermal capacitance can be calculated in each layer, then the temperature of each layer can be calculated by power loss and thermal capacitance in thermal model part. This paper also analyzes the electrical and thermal characteristic in the case of normal operating condition and transient including single line to ground fault and line to line ground fault using new simulation method.

직접 접촉식 4단 유동층 열교환기의 압력손실 및 열전달 특성 (The Pressure Drop and Heat Transfer Characteristics of a Direct Contact 4-Stage Fluidized Bed Heat Exchanger)

  • 임동렬;박상일;전광민
    • 대한기계학회논문집
    • /
    • 제16권2호
    • /
    • pp.325-335
    • /
    • 1992
  • In this work, direct contact 4-stage fluidized bed heat exchanger is experimentally studied to develop a new type of heat exchanger which recovers the energy contained in the high temperature waste gas exhausted from the industrial furnaces. A sand is used as a heat transfer medium in this experiment. To determine the optimum operating condition, 11 different perforated plates which have a different free area ratio with different hole diameter are used in the experiment. From the room temperature experiment, the pressure drop which is caused by fluidized bed formation is observed. The high temperature experiment is carried out to seek the optimum operating condition of high heat efficiency at low heat exchanger operation cost. The results of experiment are as following. The pressure drop in the high temperature condition can be predicted from the results of the room temperature experiment. And Nusselt number becomes smaller due to the increased interference between sand particles as Reynolds number increases when the dilute phase fluidized beds are formed in nigh temperature condition. But heat transfer amount through the total sand surface area become larger due to the large resident amount of sand. Considering the heat transfer amount and the heat exchanger operation cost, perforated plates which have either a 30% or 35% of free area ratio with 15mm of hole diameter are best fitted for our goal of this work. The values of .phi. which is a dimensionless number representing the absorption heat amount per unit sand rate are in the range from 0.4 to 0.5, when Reynolds number of waste gas ranges from 25-30 with these perforated plates.

Conductive link between cryocooler and magnet in cryogen-free LTS magnet system

  • Choi, Yeon Suk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권4호
    • /
    • pp.59-62
    • /
    • 2013
  • The conductive link is used as a cooling medium between a cryocooler and magnet in a cryogen-free superconducting magnet system. The low temperature superconducting (LTS) magnet has one solenoidal configuration with a metal former which has a 52 mm room temperature bore. The superconducting coil is installed in the cryostat maintaining high vacuum and cooled by a two-stage cryocooler. In order to maintain the operating temperature of magnet at the designed level, the cold head temperature of the cryocooler must be lower so that heat can be removed from the superconducting coil. Also, temperature difference is occurred between the magnet and cryocooler and its magnitude is dependent upon the contact resistance at the interfacial surface between metals in the conductive link. In the paper, the performance of the LTS magnet is investigated with respect to the conductive link between the magnet former and the cold head of the cryocooler. The effects of the contact pressure and interfacial materials on the temperature distribution along the conductive link are also presented.

고온용 히트파이프형 태양열 흡수기 (High-Temperature Heat-Pipe Type Solar Thermal Receiver)

  • 부준홍;정의국
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.668-671
    • /
    • 2007
  • A numerical study was conducted on a simplified model of a high-temperature solar receiver which incorporates liquid-metal heat pipe. The objective of this paper is to compare the isothermal characteristics of the heat pipe receiver with the conventional receiver utilizing convection of molten salt as heat carrier. The solar receiver was assumed to be subject to a concentration ratio between 50 and 1,000 to supply high-temperature heat to a stirling engine for electric power generation. For simplicity of the analysis, a cylindrical geometry was assumed and typical dimensions were used based on available literature. The heat pipe had a shape of double-walled cavity and the working fluid was a sodium. The analysis was performed assuming that the radiation heat flux on the inner walls of the receiver was uniform, since the focus of this study was laid on the comparison of the conventional type and heat pipe type receiver. The results showed that the heat pipe type exhibited superior performance when the operating temperature becomes higher. In addition, to explore the advantage of the heat pipe receiver, the channel shape and dimensions should be adjusted to increase the heat transfer area between the wall and the heat trnasfer medium.

  • PDF

상용차용 고분자 전해질 연료전지 냉각시스템 배열에 따른 성능 특성 (Performance of Fuel Cell System for Medium Duty Truck by Cooling System Configuration)

  • 우종빈;김영현;유상석
    • 한국수소및신에너지학회논문집
    • /
    • 제32권4호
    • /
    • pp.236-244
    • /
    • 2021
  • Fuel cell systems for medium duty truck require high power demands under driving. Since high power demands results in significant heat generation, thermal management is crucial for the performance and durability of medium duty truck. Therefore, various configurations of dual stacks with cooling systems are investigated to understand appropriate thermal management conditions. The simulation model consists of a dynamic fuel cell stack model, a cooling system model equipped with a controller, and the mounted controller applies a feedback controller to control the operating temperature. Also, In order to minimize parasitic power, the comparison of the cooling systems involved in the arrangement was divided into three case. As a result, this study compares the reaction of fuel cells to the placement of the cooling system under a variety of load conditions to find the best placement method.

Optimizing Oily Wastewater Treatment Via Wet Peroxide Oxidation Using Response Surface Methodology

  • Shi, Jianzhong;Wang, Xiuqing;Wang, Xiaoyin
    • 대한화학회지
    • /
    • 제58권1호
    • /
    • pp.80-84
    • /
    • 2014
  • The process of petroleum involves in a large amount of oily wastewater that contains high levels of chemical oxygen demand (COD) and toxic compounds. So they must be treated before their discharge into the receptor medium. In this paper, wet peroxide oxidation (WPO) was adopted to treat the oily wastewater. Central composite design, an experimental design for response surface methodology (RSM), was used to create a set of 31 experimental runs needed for optimizing of the operating conditions. Quadratic regression models with estimated coefficients were developed to describe the COD removals. The experimental results show that WPO could effectively reduce COD by 96.8% at the optimum conditions of temperature $290^{\circ}C$, $H_2O_2$ excess (HE) 0.8, the initial concentration of oily wastewater 3855 mg/L and reaction time 9 min. RSM could be effectively adopted to optimize the operating multifactors in complex WPO process.