• Title/Summary/Keyword: Medium Voltage System

Search Result 140, Processing Time 0.021 seconds

A Study on Constructing the Prediction System Using Data Mining Techniques to Find Medium-Voltage Customers Causing Distribution Line Faults (특별고압 수전설비 관리에 데이터 마이닝 기법을 적용한 파급고장 발생가능고객 예측시스템 구현 연구)

  • Bae, Sung-Hwan;Kim, Ja-Hee;Lim, Han-Seung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2453-2461
    • /
    • 2009
  • Faults caused by medium-voltage customers have been increased and enlarged their portion in total distribution faults even though we have done many efforts. In the previous paper, we suggested the fault prediction model and fault prevention method for these distribution line faults. However we can't directly apply this prediction model in the field. Because we don't have an useful program to predict those customers causing distribution line faults. This paper presents the construction method of data warehouse in ERP system and the program to find customers who cause distribution line faults in medium-voltage customer's electric facility management applying data mining techniques. We expect that this data warehouse and prediction program can effectively reduce faults resulted from medium-voltage customer facility.

Analysis of operation performance of PHILS-based superconducting current limiter connected to MVDC system

  • Seok-Ju Lee;Jae In Lee
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.4
    • /
    • pp.54-59
    • /
    • 2023
  • In this paper, we analyze experimental results by applying the PHILS model to a lab-scale superconducting current limiter system for its actual application in medium-voltage direct current (MVDC) systems. Superconducting current limiters exhibit effective current-limiting performance in circuit breaker operations, particularly in limiting large fault currents within a short period, addressing the challenges posed by the increasing use of renewable energy and the integration of DC medium-voltage distribution systems. The development of such superconducting current limiters faces various technical and cost disadvantages, especially when applying a medium-voltage 35kV level system, which is intended for future introduction. The proven lab-scale superconducting current limiter system and the PHILS model are combined and integrated into the actual system. Our plan involves analyzing the limiter's performance, assessing its impact on the system, and preparing for its application in future medium-voltage systems. Utilizing RTDS, a simulation was conducted by connecting actual scaled-down equipment and systems, with the analysis results presented.

A study on Reliability Enhancement Method and the Prediction Model Construction of Medium-Voltage Customers Causing Distribution Line Fault Using Data Mining Techniques (데이터 마이닝 기법을 이용한 특별고압 파급고장 발생가능 고객 예측모델 구축 및 신뢰도 향상방안에 관한 연구)

  • Bae, Sung-Hwan;Kim, Ja-Hee;Hong, Jung-Sik;Lim, Han-Seung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1869-1880
    • /
    • 2009
  • Distribution line fault has been reduced gradually by the efforts on improving the quality of electrical materials and distribution system maintenance. However faults caused by medium voltage customers have been increased gradually even though we have done many efforts. The problem is that we don't know which customer will cause the fault. This paper presents the concept to find these customers using data mining techniques, which is based on accumulated fault records of medium voltage customers in the past. It also suggests the prediction model construction of medium voltage customers causing distribution line fault and methods to enhance the reliability of distribution system. We expect that we can effectively reduce faults resulted from medium voltage customers, which is 30% of total faults.

The Evaluation of Medium Voltage Motor's Current and Voltage Harmonics during Loading

  • Alboyaci, Bora;Yorukeren, Nuran
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.35-41
    • /
    • 2007
  • This paper presents the results of investigating harmonic levels on medium voltage motors at loading conditions in air separation plant. The essential results of the measurements of the medium voltage motor harmonics are summarized in the values for the total harmonic distortion (THD). Motors loading case is used to assess the current and voltage harmonic distortions. Proper system analysis is important when adding a new motor starting and controlling the equipment. With the result of the paper it is possible to suggest the most appropriate starting and control method. Two medium voltage motors of air separation unit measurement results and simulations are summarized. Both current and voltage harmonic distortions are fitted by using a linear and exponential regression model. The prediction of THD values can be used for this kind of process for future planning by utilities.

Improved Modulation Scheme for Medium Voltage Modular Multi-level Converter Operated in Nearest Level Control (근사레벨제어로 동작하는 중전압 모듈형 멀티레벨 컨버터의 개선된 전압변조기법)

  • Kim, Do-Hyun;Kim, Jae-Hyuk;Han, Byung-Moon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.4
    • /
    • pp.285-296
    • /
    • 2017
  • This paper proposes an improved modulation scheme for the medium voltage modular multi-level converter (MMC), which operates in the nearest level control and applies in the medium voltage direct current (MVDC) system. In the proposed modulation scheme, the offset (neutral-to-zero output) voltage is adjusted, with the phase voltage magnitude, thereby maintaining a constant value with N+1 level in the controllable modulation index (MI) range. In order to confirm the proposed scheme's validity, computer simulations for the 22.9 kV - 25 MVA MMC were performed with PSCAD/EMTDC, as well as hardware experiments for the 380 V - 10 kVA MMC. The proposed modulation scheme offers to build a constant pole voltage regardless of the MI value, and to build a phase voltage with improved total harmonic distortion (THD).

Development of channel characteristics measurement system for Medium Voltage Power Line Grid (고압전력선 통신 채널 특성 측정 시스템 개발)

  • Lee, Jae-Jo;Lee, Won-Tae;Oh, Hui-Myoung;Kim, Kwan-Ho;Lee, Dae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2640-2642
    • /
    • 2002
  • In this paper, we show the channel characteristics measurement system the frequency range up to 30MHz for medium voltage Power Line Grid. Power line channel characteristics are investigated by means of various measurement instruments. Measurement system consists of medium voltage coupler, impedance measurement part, noise measurement part, voltage sensing part and communication part. Measured data will be used for PLC channel modeling and PLC network system design.

  • PDF

A Medium-Voltage Matrix Converter Topology for Wind Power Conversion with Medium Frequency Transformers

  • Gu, Chunyang;Krishnamoorthy, Harish S.;Enjeti, Prasad N.;Zheng, Zedong;Li, Yongdong
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1166-1177
    • /
    • 2014
  • A new type of topology with medium-frequency-transformer (MFT) isolation for medium voltage wind power generation systems is proposed in this paper. This type of converter is a high density power conversion system, with high performance features suitable for next generation wind power systems in either on-shore or off-shore applications. The proposed topology employs single-phase cascaded multi-level AC-AC converters on the grid side and three phase matrix converters on the generator side, which are interfaced by medium frequency transformers. This avoids DC-Link electrolytic capacitors and/or resonant L-C components in the power flow path thereby improving the power density and system reliability. Several configurations are given to fit different applications. The modulation and control strategy has been detailed. As two important part of the whole system, a novel single phase AC-AC converter topology with its reliable six-step switching technique and a novel symmetrical 11-segment modulation strategy for two stage matrix converter (TSMC) is proposed at the special situation of medium frequency chopping. The validity of the proposed concept has been verified by simulation results and experiment waveforms from a scaled down laboratory prototype.

Field Trial of Power Line Communication Access Network over Medium Voltage Power Distribution Grid (고압 배전선로를 이용한 고속 전력선 통신 가입자망 구축 연구)

  • Lee, Jae-Jo;Oh, Hui-Myoung;Park, Young-Jin;Kim, Kwan-Ho;Lee, Dae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.3040-3042
    • /
    • 2005
  • During the last several years, interest in broad-band power line communications (PLC) has been grown over medium voltage(MV) power distribution lines as well as low voltage lines. This paper introduces a medium voltage PLC test field that is set up in the suburbs of Euiwang city in Korea. This test field could be used not only for the measurement of communication channel environment but also for internet service. This paper shows the configuration of medium voltage test field with network devices like MV signal coupler and the results of channel environment like noise and impulse response. It also shows the service performance of PLC access network through network management system.

  • PDF

Controller Optimization for Bidirectional Power Flow in Medium-Voltage DC Power Systems

  • Chung, Il-Yop;Liu, Wenxin;Cartes, David A.;Cho, Soo-Hwan;Kang, Hyun-Koo
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.6
    • /
    • pp.750-759
    • /
    • 2011
  • This paper focuses on the control of bidirectional power flow in the electric shipboard power systems, especially in the Medium-Voltage Direct Current (MVDC) shipboard power system. Bidirectional power control between the main MVDC bus and the local zones can improve the energy efficiency and control flexibility of electric ship systems. However, since the MVDC system contains various nonlinear loads such as pulsed power load and radar in various subsystems, the voltage of the MVDC and the local zones varies significantly. This voltage variation affects the control performance of the bidirectional DC-DC converters as exogenous disturbances. To improve the control performance regardless of uncertainties and disturbances, this paper proposes a novel controller design method of the bidirectional DC-DC converters using $L_1$ control theory and intelligent optimization algorithm. The performance of the proposed method is verified via large-scale real-time digital simulation of a notional shipboard MVDC power system.

Medium Voltage Power Supply with Enhanced Ignition Characteristics for Plasma Torches

  • Jung, Kyung-Sub;Suh, Yong-Sug
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.591-598
    • /
    • 2011
  • This paper investigates a power supply of medium voltage with enhanced ignition characteristics for plasma torches. A series resonant half-bridge topology is presented as a suitable ignition circuitry. The ignition circuitry is integrated into the main power conversion system of a multi-phase staggered three-level dc-dc converter with a diode front-end rectifier. A plasma torch rated at 3MW, 2kA and having a physical size of 1m is selected to be the high enthalpy source for a waste disposal system. The steady-state and transient operations of a plasma torch are simulated. The parameters of a Cassie-Mary arc model are calculated based on 3D magneto-hydrodynamic simulations. The circuit simulation waveform shows that the ripple of the arc current can be maintained within ${\pm}10%$ of its rated value under the presence of a load disturbance. This power conversion configuration provides a high enough ignition voltage, around 5KA, during the ignition phase and high arc stability under the existence of arc disturbance noise resulting in a high-performance plasma torch system.