Comparison of using CBCT with CT simulator for radiation dose of treatment planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Cho, jung-keun;Kim, dae-young;Han, tae-jong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1159-1166
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

  • PDF

A cognitive survey on the Diversification of class year from Junior Colleges by Changing Educational Environment-Focused on Health Sciences Departments (교육환경 변화에 따른 전문대학 수업 연한 다양화에 대한 인식조사 - 보건계열학과 중심으로)

  • Park, Cheolin;Park, Su-Jin;Kwon, Soon-Mu;Kim, Won-Gi;Chang, Ki-whan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.186-196
    • /
    • 2018
  • Junior colleges are higher education institutions that have played a major role in the economic development of Korea by providing the necessary human resources for its industrial development. Recently, however, they have experienced difficulties due to the reduction in the number of students. Therefore, it is time for junior colleges as a representative higher vocational education institution to change their role in this rapidly changing environment, and adopt a survival strategy through mutual cooperation and competition. The purpose of this study was to analyze the current state of the national health universities, to investigate the policy changes adopted by colleges and universities, and to utilize the results as data. This study analyzed the current status of health science colleges nationwide and investigated the policy changes as well as the directions presented to the colleges, in order to use the results as the basic data to promote the diversification of the class periods and degree programs. This study surveyed 636 professors from health sciences departments and industry workers from May 1 to May 30, 2017. 70.7% of the respondents supported the transition of the existing three-year systems of the health science departments to four-year systems. The reason for this is that it is possible to strengthen the field practice and personality education of the students by having a sufficient number of class periods, and to provide them with an equal educational background. The most anticipated effect of the transition to a four-year system is to improve the social status of medical personnel and to improve the educational environment of the colleges/universities. Moreover, the universities, associations of medical personnel and Ministry of Education are expected to play a leading role in the transition to the four-year system. Based on the results of this study, it was concluded that a more systematic and advanced vocational education system for the training of professional healthcare workers is needed in the upcoming fourth Industrial Revolution era. Also, this transition is expected to actively foster the education of advanced health care workers thanks to the diversification of the degree programs through the adjustment of the class periods which can be completed by general university (4-year) graduates.

The Bibiographical investigation of effect of GYPSUM FIBROSUM in Dongyi Soose Bowon (동의수세보원(東醫壽世保元)에서의 석고(石膏)의 약리(藥理)에 대한 문헌적(文獻的) 고찰(考察))

  • Jung, Kwang-hee;Koh, Byung-hee;Song, Il-byung
    • Journal of Sasang Constitutional Medicine
    • /
    • v.12 no.1
    • /
    • pp.110-119
    • /
    • 2000
  • 1. Purpose and Method We do not have the Sasagn Consitutional Pharmacology exactly. So we use Sasagn Consitutional medical herbs based on the theory of Yin-yang and the five elements herbology. So I try to objectify Sasagn Consitutional Classification of Gypsum Fibrosum in DongyiSooseBowon. Among the soyangin(少陽人) Pyobyung(表病) prescription, Fever MangYin Symptom(fever, headache, diarrhea) prescription include Gypsum Fibrosum, Cold MangYin Symptom(cold, pain in abdomen, diarrhea) prescription does not include Gypsum Fibrosum. So, I to make manifest the spirit of using Gypsum Fibrosum in Soyangin(少陽人) PyoByung(表炳), and the differences of two symptom, and the literature on this subject, I searched oriental medical books. 2. result 1. The management of Gypsum Fibrosum is to grind and make powder. 2. The spirit of using Gypsum Fibrosum in Soyangin(少陽人) Fever MangYi Symptom(fever, headache, diarrhea) prescription is Cleanse the Inside fever and Down the Outside Yin. 3. Fever MangYin Symptom(fever, headache, diarrhea) prescription include Gypsum Fibrosum, Cold MangYin Symptom(cold, pain in abdomen, diarrhea) prescription does not include Gypsum Fibrosum. and The Important syndrome of using Gypsum Fibrosum in Soyangin(少陽人) Fever MangYin Symptom(fever, headache, diarrhea) is fever and headache. 4. Gypsum Fibrosum is The representative herb on Soyangin FeverSymptom. 5. The site of therapeutic action of Gypsum Fibrosum is Wiguk(胃局) - Upper Juncho

  • PDF

Effect of CT Contrast Media on Radiation Therapy Planning (Head & Neck Cancer and Prostate Cancer) (CT조영제가 방사선치료계획(두경부, 전립선)에 미치는 영향)

  • Jang, Jaeuk;Han, Manseok;Kim, Minjeong;Kang, Hyeonsoo
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.5
    • /
    • pp.173-178
    • /
    • 2016
  • This study is to evaluate the effect of a Contrast Media (CM) on dose calculations and clinical significance in Radiation (Electromagnetic wave) Therapy (RT) plans for head & neck (H&N) and prostate cancer. Pinnacle 8.0 system was used to measure the change of Electron Density (ED) of the tissue for CM. To determine the effect of dose calculation due to CM, we did the RT planning for 30 patients. To compare the ED and dose calculations of RT plans, 3D CRT and IMRT plans were do with pinnacle and Tomotherapy planning system. Mean difference of ED between enhanced and unenhanced CT was less than 4%: H&N Target Volume (TV) 2.1%, parotid 1.9%, SMG 3.6%, tongue 0.9%, spinal cord 0.3%, esophagus 2.6%, mandible 0.1% and prostate TV 0.7%, lymph node 1.1%, bladder 1.2%, rectum 1.5%, small bowel 1.2%, colon 0.6%, penile bulb 0.8%, femoral head -0.2%. The dose difference between RT plan using CM and without CM showed an increase of dose in TV. The rate of increase was less than 2.5% (3D CRT: H&N 0.69~2.51%, prostate 0.04~1.14%, IMRT: H&N 0.58~1.31%, prostate 0.36~1.04%). RT plans using a CM has the insignificant effect on the organs and TV, so this error is allowable clinically. However, the much more accurate plan is possible as to image fusion (CM and without CM images) to ROI contour and when dose calculation, use the without CM image. Using the fusion of 'ROI import' perform calculations on without CM, it will be able to reduce the error (1~3%) caused by the CM.

A STUDY ON THE FIVE ELEMENT THEORY INTODUCED (<황제내경(黃帝內經)>에 유입(流入)된 오행학설(五行學說)에 관(關)한 연구(硏究))

  • Kim, Boo-Hwan;Park, Hyun-Kook
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.1
    • /
    • pp.161-191
    • /
    • 1992
  • The purpose of this study is how have the form and theory of the five element theory in the (黃帝內徑) by the investigation of the course of the course of the five element introduced the ancient oriental medicine from ancient oriental philosophy. The following results were obtained. 1. The five elements in (尙書) meaned the uses of water, fire, earth, wood, metal which were important in living. Because these had very important meaning in ancient political and economic society, emphasized to big law(洪範) 2. The five elements in (左傳) and (國語) mean the five uses too, and there are the phases of "five win metal"(火勝金) and "wather win fire"(水勝火), but these only meaned the physical interrelation. 3. In the five circulating factor theory made by Chu Yen(鄒衍) which have the attribute of the five elements, he more reasonably had argued human affairs like that a dynasty become different in step with the circulating five favors. There is the regular annual policy in the (呂氏春秋) which closely connected nature and human living, and attached the various colors, animals, visceras, flavors, sounds, the sexagenary cycle and so on to the five elements. 4. In the (春秋繁露) writed in fore-period of Han(漢) dynasty, the interactions of the five elements are concretely applicated to policy, Dong Jung Soe(童仲舒) had discrived the interactions of the five elements by Dong Lyu Sang Dong theory(同類相動說) and the misfortune theory(災異說), emphasized the sympathy of nature and human. Thought there is many content which are superstitious and contradictory, I concider which that affcted many effects in the formation of five element theory of oriental medicine. In the (淮南子) the order of matters were explained by the five element theory too, as the interrelations of the five elements were explained by the sexagenary ctcle, I assume that the bud of O-Un theory(五運理論). And there was not founded the fullscale intriduction of the five element theory in the Ma Wang Tye(馬王堆) excavated finds, the Mu Yyi medical writings formed the dynasty(武威漢代醫簡) and the documents about Pyun Jak(偏鵲) and Sun U Ie(淳于意). 5. The application of the five element theory in the (Whang Di Nei Qing) (黃帝內徑) is devided into the attachement to the five elements, the interelations of the five elments, and Un Gi theery(運氣論). In the attachment to the five elemeant theory, it made the attachment of the five viseras of (今文尙書) party a standard and attached the sections of a human body, the whole internal organs of sense, the five colors, the five flavors and the five sounds and so on to the five elements. It put to use by means of the apllivation of the interrelation of the five elements in the transferations of the diseases and the relative severeness of a disease in step with change of time and season. Un Gi theory(運氣論) which synthesized by the attachment to the five elements, the inter-relations of the five elements and the climate which observerd from ancient times systematically argued the effects of weather to human. 6. The application of the five elements theory in (黃帝內徑) have the significant what had get rid of irrational factors like that the emotion and action of human could to influense the weather, what had been formes more rational thingking by the obesrvation of human and nature. It is required more reserches about the possibility of the formation of the doctrinal faction bt the geographical effect of the Yon, Je(燕,薺) region, the application of the five element theory in other ancient medical books and the relationship of the five element theory and Yin Yang(陰陽)

  • PDF

Development of Phantom and Comparison Analysis for Performance Characteristics of MOSFET Dosimeter (MOSFET 선량계 특성분석을 위한 팬톰 개발 및 특성 비교)

  • Chung, Jin-Beom;Lee, Jeong-Woo;Kim, Yon-Lae;Lee, Doo-Hyun;Choi, Kyoung-Sik;Kim, Jae-Sung;Kim, In-Ah;Hong, Se-Mie;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.18 no.1
    • /
    • pp.48-54
    • /
    • 2007
  • This study is to develope a phantom for MOSFET (Metal Oxide Semiconductors Field Effect Transistors) dosimetry and compare the dosimetric properties of standard MOSFET and microMOSFET with the phantom. In this study, the developed phantom have two shape: one is the shape of semi-sphere with 10cm diameters and the other one is the flat slab of $30{\times}30cm$with 1 cm thickness. The slab phantom was used for calibration and characterization measurements of reproducibility, linearity and dose rate dependency. The semi-sphere phantom was used for angular and directional dependence on the types of MOSFETs. The measurements were conducted under $10{\times}10cm^2$ fields at 100cm SSD with 6MV photon of Clinac (21EX, Varian, USA). For calibration and reproducibility, five standard MOSFETS and microMOSFETs were repeatedly Irradiated by 200cGy five times. The average calibration factor was a range of $1.09{\pm}0.01{\sim}1.12{\pm}0.02mV/cGy$ for standard MOSFETS and $2.81{\pm}0.03{\sim}2.85{\pm}0.04 mV/cGy$ for microMOSFETs. The response of reproducibility in the two types of MOSFETS was found to be maximum 2% variation. Dose linearity was evaluated In the range of 5 to 600 cGy and showed good linear response with $R^2$ value of 0.997 and 0.999. The dose rate dependence of standard MOSFET and microMOSFET was within 1% for 200 cGy from 100 to 500MU/min. For linearity, reproducibility and calibration factor, two types of MOSFETS showed similar results. On the other hand, the standard MOSFET and microMOSFET were found to be remarkable difference in angular and directional dependence. The measured angular dependence of standard MOSFET and microMOSFET was also found to be the variation of 13%, 10% and standard deviation of ${\pm}4.4%,\;{\pm}2.1%$. The directional dependence was found to be the variation of 5%, 2% and standard deviation of ${\pm}2.1%,\;{\pm}1.5%$. Therefore, dose verification of radiation therapy used multidirectional X-ray beam treatments allows for better the use of microMOSFET which has a reduced angular and directional dependence than that of standard MOSFET.

  • PDF

Current Status and the Future Prospect of Rehabilitation Nursing in Korea (한국 재활간호 현황과 전망)

  • Kang, Hyun-Sook;Suh, Yeon-Ok;Lee, Hae-Sook
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.4 no.2
    • /
    • pp.240-247
    • /
    • 2001
  • The history of rehabilitation of disabilities in Korea began with the foreigners and missionaries who were interested in it after Korean War. In 1981, Disabled Persons Welfare Act was enacted and the 88 Paralympics brought the nations attention to the welfare and rehabilitation of persons with disabilities. Since then, the facilities and the services for the disabled persons have expanded rapidly and the rehabilitation treatment and nursing intervention are drawing more attention. Against this background, the survey on the current status of disabilities, welfare service, facilities, and rehabilitation nursing was conducted. The results of this survey are as follows. 1. According to the 2000 census of disabilities, the number of persons with disabilities in Korea is estimated at 1,449,500, or 3.09% of the entire Korean population, 0.74% up from 2.35% in 1995. 2. Disability Types in 2000 The 2000 census showed that the persons with disabilities numbered 1,449,496 out of the total population and 1,024,371 persons are registered for disability, making up 70.7% of the estimated disabled population. Among them, physically disabled persons accounted for the largest 41.7% (605,127) and mentally retarded persons stood at the smallest 9% (13,481). 3. Percentage of Disability Presence The survey showed that more than 90% of disability were acquired. However, 44.8% of mental disability and 61.4% of hearing/speaking disability were not acquired after birth. This means that these disabilities happened by congenital cause or birth accident. 4. Yearly Figure of Registered Disabled Persons In 1989, 218,601 persons registered for disability and, in 2000, the number increased by 4.7 times to 1,024,371. These figures are different from the actual number of disabled persons. According to the 1995 census, 1,053,486 were disabled persons but only 378,323registered for disability. And, in the 2000 census, 1,024,371 out of the 1,449,496 of disabled persons registered for disability. 5. Welfare Service for Persons with Disability 62.6% of the total disabled people are registered and physically disabled persons accounted for the highest percentage of 96.7%. 26.5% of non-registered disabled people said that they didnt know the registration procedure. The rest of them replied that they didnt think they were disabled or that registration didnt seem to give any benefits. 6. Welfare Policies for Disabled Persons The welfare benefits given to the disabled are as follows: Issuance of disabled sign for car drivers, Permission to use LPG fuel, Communication fee reduction, Tax exemption related to cars, Reduction of public facility fees, Household allowance, Tax reduction or exemption, Medical allowance and education subsidy for children, and Housing. 7. Current Condition of Welfare Facilities by Disability Type The welfare institutions for disabilities numbered 188 in total and they can accommodate 16,823 persons. Categories of these institutions are physical disability(37), visual disability(10), hearing/speaking disability(14), mental retardation(59), and sanatoriums(68). 8. Human Resource of Rehabilitation of Disabilities Advanced education programs include rehabilitation nursing in its curriculum and this was selected as the program of Korean Academic Society of Nursing in 1990. In November 1997, Korean Academic Society of Rehabilitation Nursing was launched and many academic meeting and seminars were held. This organization is also making efforts to develop the education program for qualified rehabilitation nursing professionals and to develop the standards of rehabilitation nursing practice. In the professionals of the rehabilitation, there are rehabilitation specialist, physical therapist, speech therapist, occupational therapist. It is needed to come up with the measures to supply stable human resources following the demand of disabled persons and to recognize the private certificates for rehabilitation professionals as official ones after reviewing the education and training programs of private institutions. 9. Rehabilitation Nursing 1) Rehabilitation nursing was taught as an independent subject in 11 undergraduate programs and 9 graduate programs. 2) Research on rehabilitation nursing in Korea were 24 experimental research and 11 non-experimental research. The intervention of experimental research were mostly education and exercise rehabilitation programs. 3) In the three rehabilitation hospitals, nursing is divided into two categories, direct nursing and education & counseling. Direct nursing includes tracheostomy or nasogastric tube care, urination and defication, skin care, pain control, complication prevention and care, prevention of injury from a fall, etc.

  • PDF

A Review of Questionnaire for the Clinical Trials on Chronic Low Back Pain (만성 요통 임상연구에 사용된 설문지 현황 고찰)

  • Kim, Doo-Hee;Shin, Woo-Suk;Lee, Jin-Won;Park, Won-Hyung;Cha, Yun-Yeop;Ko, Youn-Seok;Lee, Jung-Han;Chung, Won-Suk;Shin, Byung-Cheul;Song, Yun-Kyung;Go, Ho-Yeon;Sun, Seong-Ho;Jeon, Chan-Yong;Jang, Bo-Hyoung;Ko, Seong-Gyu
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.23 no.4
    • /
    • pp.95-115
    • /
    • 2013
  • Objectives The aim of this review is to provide fundamental data for low back pain scales which can be used in clinical trial. Methods We investigated the latest studies on chronic low back pain via PubMed. And we also investigated domestic studies through "http://oasis.kiom.re.kr". 95 research papers were analyzed. Scales were classified into pain scale, function scale, generic health status scale and psychological scale. Results 1) According to foreign clinical studies, Visual Analog Scale (VAS) and Numerical Rating Scale (NRS) were used 18 times as pain scale. Oswestry Disability Index (ODI) was used 20 times as function scale, Roland-Morris Disability Questionnaire (RMDQ) was 17, and Hannover Functional Ability Questionnaire (HFAQ) was used 3 times. 36-item Short Form Health Survey (SF-36) was used 13 times as generic health status scale, Euroqol-5 Dimentions Questionnaire (EQ-5D) was 11, and 12-item Short Form Health Survey (SF-12) was used 3 times. Fear-Avoidance Beliefs Questionnaire (FABQ) was used 9 times as psychological scale, Pain Catastrophizing Scale (PCS) and Tampa Scale for Kinesiophobia (TSK-R) both were used 3 times. 2) According to domestic clinical studies, VAS was used 37 times as pain scale, NRS was 11, and Short Form McGill Pain Questionnaire (SF-MPQ) was used 6 times. ODI was used 30 times as function scale, RMDQ was 2 times only. SF-36 was used once as generic health status scale and Beck's Depression Inventory (BDI) was used 3 times as psychological scale. Conclusions We recommend VAS or NRS as a measure to evaluate pain, and ODI as a measure to evaluate functional disability. And we also recommend SF-36 or SF-12 and EQ-5D as a measure to evaluate generic health status. Finally, we recommend FABQ for use in measuring psychological scale.

The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams (6MV 광자선에서 측정 조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교)

  • 김회남;박성용;서태석;권수일;윤세철
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.87-102
    • /
    • 1997
  • The absolute absorbed dose can be determined according to the measurement conditions; measurement material, detector, energy and calibration protocols. The purpose of this study is to compare the absolute absorbed dose due to the differences of measurement condition and calibration protocols for photon beams. Dosimetric measurements were performed with a farmer type PTW and NEL ionization chambers in water, solid water, and polystyrene phantoms using 6MV photon beams from Siemens linear accelerator. Measurements were made along the central axis of 10cm $\times$ 10cm field size for constant target to surface distance of 100cm for water, solid water and polystyrene phantom. Theoretical absorbed dose intercomparisons between TG21 and IAEA protocol were performed for various measurement combinations of phantom, ion chamber, and electrometer. There were no significant differences of absorbed dose value between TG21 and IAEA protocol. The differences between two protocols are within 1% while the average value of IAEA protocol was 0.5% smaller than TG21 protocol. For the purpose of comparison, all the relative absorbed dose were nomalized to NEL ion chamber with Keithley electrometer and water phantom, The average differences are within 1%, but individual discrepancies are in the range of - 2.5% to 1.2% depending upon the choice of measurement combination. The largest discrepancy of - 2.5% was observed when NEL ion chamber with Keithley electrometer is used in solid water phantom. The main cause for this discrepancy is due to the use of same parameters of stopping power, absorption coeficient, etc. as used in water phantom. It should be mentioned that the solid water phantom is not recommended for absolute dose calibration as the alternative of water, since absorbed dose show some dependency on phantom material other than water. In conclusion, the trend of variation was not much dependent on calibration protocol. However, it shows that absorbed dose could be affected by phantom material other than water.

  • PDF

Usefulness of Registration in the Evaluation of Parkinson′s Disease (영상 융합하여 분석한 파킨슨씨병 환자영상의 유용성)

  • 주라형;김재승;문대혁;최보영;서태석
    • Progress in Medical Physics
    • /
    • v.14 no.4
    • /
    • pp.268-278
    • /
    • 2003
  • Purpose:The aim of this study was to evaluate the striatal binding ratio, the anterior/posterior ratio and reproducibility using a template based registration method using the standard MR template as a replacement for each patients MR image. Materials and Methods:This study analyzed the 123I IPT SPECT images of 30 patients with IPD, who were subdivided into 17 patients (56.6$\pm$10.8 yr, M/F : 8/9.) with mild IPD, and 13 patients (56.4$\pm$11.1 yr, M/F : 8/5) with severe IPD. In addition, 11 normal controls (57.8$\pm$14.4 yr, M/F : 4/7) were also analyzed. The ROIs were positioned manually in the same slice showing the highest striatal activity using the traditional manual method, whereas those were positioned automatically in a mid striatal slice of the SPECT image coregistered to the standard T1 weighted MR template. Results : The specific binding ratio (SBR) obtained using the template based registration method strongly correlated with those using the manual method in all groups : normal controls (r=0.85, P<0.001), mild IPD (r=0.84, P<0.001) and severe IPD (r=0.7, P=0.01). The SBRs obtained using both methods were significantly different among the three groups (P=0.05) and the SBRs obtained by the template based registration method were higher than those by the manual method (P=0.05) in all three groups. The APRs obtained by the template based registration correlated with those using manual method in only mild IPD (r=0.72, P=0.0). The APRs obtained by the template based registration method were significantly different from the normal controls and those with mild or severe IPD (P<0.05), whereas those obtained using the manual method were not significantly different among the three groups (P>0.1). The reproducibility (rmsCV) of the template based registration method was 7.2% (normal controls:5.2%, mild IPD:4.2%, severe IPD:10.8%), whereas the reproducibility of the manual method was 31% (normal controls:19.7%, mild IPD:21.7%, severe IPD:46.2%). Conclusion:These results show that the use of $^{123}$ I-IPT SPECT for assessing IPD is affected by the methods used to position the striatal ROI. The template based registration method using the standard MR template can be useful in diagnosing IPD and assessing the disease severity with a high reproducibility. Therefore, the template based registration method appears to be a good replacement for the manual method.

  • PDF