• Title/Summary/Keyword: Medical ultrasound system

Search Result 161, Processing Time 0.025 seconds

A Study on Blood Flow Measurement Method using Independent Component Analysis (독립성분분석을 이용한 혈류 속도 측정 방법에 관한 연구)

  • Cho, Seog-Bin;Lim, Dong-Seok;Baek, Kwang-Ryul
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.2 s.314
    • /
    • pp.10-17
    • /
    • 2007
  • The echo signal on ultrasonic transducer is a mixed signal from tissues, blood vessel walls, blood cells and noise. In this mixed-signal, the signal reflected from tissues and blood vessel walls is called clutter. It is necessary to extract pure blood signal from this mixed-signal, when measuring blood flow velocity with medical ultrasonic system The quality of measured blood flow velocity is highly dependent on sufficient attenuation of the clutter signals. In this paper, we suggest a clutter rejection method using ICA For simulation, the echo signals are generated by Field n ultrasonic simulation program In this echo signals, independent signals are separated by using ICA Then the blood signal is obtained from the separated signals. Blood flow velocity is measured by 2D autocorrelation method. We compare ICA clutter rejection method with PCA-based eigen filter method using both measured blood flow velocity profiles by 2D autocorrelation. In simulation results, ICA clutter rejection method can be better applied measuring blood flow velocity in noisy echo signals.

The Evaluation about the Information Fidelity in the External Image Information Input - Using DICOM Validation Tool - (외부영상정보 입력 시 DICOM정보 충실성에 대한 평가 - DICOM Validation Tool 이용 -)

  • Lee, Song-Woo;Lee, Ho-Yeon;Do, Ji-Hoon;Jang, Hye-Won
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.1
    • /
    • pp.33-38
    • /
    • 2011
  • Now a days, there's many change over for PACS among the most of hospital and it standard for DICOM 3.0. These kind of using of DICOM 3.0 improves increasing of medical imaging exchange and service for patient. However, there's some problems of compatibility caused during carry out CD and DVD from hospital. For this reason, this thesis analyzed patients image targeting those storages requested to hospitals in Seoul by using Validation Toolkit which is recommended from KFDA. The analyze type is like this. Make 100 data, total 500, each of MRI CT Plain x-ray Ultrasound PET-CT images and analyzed type of error occurred and loyalty of information. If express percentage of error occurred statistically, we can get a result as follows MRI 5%, Plain x-ray 11%, CT 18%, US 25%, PET-CT 30%. The reson why percentage of error occurred in PET-CT is because of imperfective support and we could notice that we weren't devoted to information. Even though, PET-CT showed highest percentage of error occurred, currently DICOM data improved a lot compare to past. Moreover, it should be devoted to rule of IHE TOOL or DICOM. In conclusion, we can help radiographer to analyze information of image by providing clues for solving primary problem and further more, each of PACS company or equipment company can enhance fidelity for following standard of image information through realizing the actual problem during transfer of image information.

  • PDF

Animal Diagnosis System Using Wireless Digital Stethoscope (무선 디지털청진기를 이용한 동물 진단시스템)

  • Park, Kee-Young;Hong, Soo-Mi;Lee, Jong-Ha;Park, Jin-Ho;Jung, Eui-Bung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.9
    • /
    • pp.722-727
    • /
    • 2013
  • Medical treatment for animals is very difficult as the opinions of pets' masters take priority over treatment regardless of the seriousness of pets' disease or the needs of medical treatment. In case that a pet has heart disease, especially, it is difficult to get the direct answer from the pet's master on the decision or confirmation of treatment. For those reasons, it is almost impossible to predict and treat the pet before an emergency like the heart failure or an unexpected death happens. Using stethoscope can be the first diagnosis method to check the heart or any kinds of disease inside the body. High-tech equipments like CT, X-ray or Ultrasound can be used, but they can only be used as a second choice of diagnosis method since it requires professional skills and its high price. That's why stethoscope is still the best diagnostic tool when one makes the first diagnosis. In this study, we give a detailed account of digital diagnosis system in which veterinarians can analyze the sound from stethoscope without bringing it to their ears and make a diagnosis wherever they are. And we suggest a new concept of diagnosis system surrounding, which shows the relativeness of disease through Level Crossing Rate(LCR) and energy level from the stethoscope sound made in this system.

Nondestructive Inspection of Steel Structures Using Phased Array Ultrasonic Technique (위상배열 초음파기법을 이용한 강구조물의 비파괴 탐상)

  • Shin, Hyeon-Jae;Song, Sung-Jin;Jang, You-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.538-544
    • /
    • 2000
  • A phased array ultrasonic nondestructive inspection system is being developed to obtain images of the interior of steel structures by modifying a medical ultrasound imaging system. The medical system consists of 64 individual transceiver channels that can drive 128 array elements. Several modifications of the system were required mainly due to the change of sound speed. It was necessary to fabricate array transducers for steel structure and to obtain A-scan signal that is necessary for the nondestructive testing. Boundary diffraction wave model was used for the prediction of radiation beam field from array transducers, which provided guidelines to design array transducers. And a RF data acquisition board was fabricated for the A-scan signal acquisition along a selected un line within an image. For the proper beam forming in the transmission and reception for steel structure, delay time was controlled. To demonstrate the performance of the developed system and fabricated transducers, images of artificial specimens and A-scan signals for selected scan lines were obtained in a real time fashion.

  • PDF

Use of Imaging and Biopsy in Prostate Cancer Diagnosis: A Survey From the Asian Prostate Imaging Working Group

  • Li-Jen Wang;Masahiro Jinzaki;Cher Heng Tan;Young Taik Oh;Hiroshi Shinmoto;Chau Hung Lee;Nayana U. Patel;Silvia D. Chang;Antonio C. Westphalen;Chan Kyo Kim
    • Korean Journal of Radiology
    • /
    • v.24 no.11
    • /
    • pp.1102-1113
    • /
    • 2023
  • Objective: To elucidate the use of radiological studies, including nuclear medicine, and biopsy for the diagnosis and staging of prostate cancer (PCA) in clinical practice and understand the current status of PCA in Asian countries via an international survey. Materials and Methods: The Asian Prostate Imaging Working Group designed a survey questionnaire with four domains focused on prostate magnetic resonance imaging (MRI), other prostate imaging, prostate biopsy, and PCA backgrounds. The questionnaire was sent to 111 members of professional affiliations in Korea, Japan, Singapore, and Taiwan who were representatives of their working hospitals, and their responses were analyzed. Results: This survey had a response rate of 97.3% (108/111). The rates of using 3T scanners, antispasmodic agents, laxative drugs, and prostate imaging-reporting and data system reporting for prostate MRI were 21.6%-78.9%, 22.2%-84.2%, 2.3%-26.3%, and 59.5%-100%, respectively. Respondents reported using the highest b-values of 800-2000 sec/mm2 and fields of view of 9-30 cm. The prostate MRI examinations per month ranged from 1 to 600, and they were most commonly indicated for biopsy-naïve patients suspected of PCA in Japan and Singapore and staging of proven PCA in Korea and Taiwan. The most commonly used radiotracers for prostate positron emission tomography are prostate-specific membrane antigen in Singapore and fluorodeoxyglucose in three other countries. The most common timing for prostate MRI was before biopsy (29.9%). Prostate-targeted biopsies were performed in 63.8% of hospitals, usually by MRI-ultrasound fusion approach. The most common presentation was localized PCA in all four countries, and it was usually treated with radical prostatectomy. Conclusion: This survey showed the diverse technical details and the availability of imaging and biopsy in the evaluation of PCA. This suggests the need for an educational program for Asian radiologists to promote standardized evidence-based imaging approaches for the diagnosis and staging of PCA.

Job Competency in Ultrasonography of Korean Radiological Technologists (한국 방사선사의 초음파진단검사 직무역량에 관한 고찰)

  • Lim, Chang Seon;Kim, Chuk Bok;Namkung, Jang Sun;Jin, Gye Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.857-864
    • /
    • 2019
  • Many countries, including Canada, operate a sonographer license system separately from a radiological technologist license. However, in Korea, radiological technologists perform ultrasound imaging under the guidance of doctors. Therefore, in order to have the opportunity to provide a systematic education by analyzing the job competency of the radiological technologist's ultrasound imaging, based on the Canadian National Competency Profile (NCP) lists, this study measured the job content validity of the job competences and detailed competencies required for performing ultrasonography in Korea. From the results of comparing and analyzing the importance of the core competencies included in the Korean radiological technologist's job competencies and the degree of job performance, the average overall importance was 4.087, the average of overall performance was 3.640, showing that the importance was higher than the performance and that there was a statistically significant difference. In conclusion, 'A Communication', 'B Professional responsibilities', 'D Operation of equipment' and 'G Workplace health and safety' showed high job content validity. However, it is said that as 'C Patient assessment and care', 'E Critical thinking and problem solving', and 'H Image' showed low job content validity, it is necessary to seek ways to strengthen and complement these competencies.

Endoscopic Bio-Imaging Using Optical Coherence Tomography (마이크로 내시경 및 첨단 광 단층촬영기법을 이용한 생체 이미징)

  • Ahn, Yeh-Chan;Brenner, Matthew;Chen, Zhongping
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.466-471
    • /
    • 2011
  • Optical coherence tomography(OCT) is an emerging medical diagnostic tool that draws great attention in medical and biological fields. It has a 10-100 times higher spatial resolution than that of the clinical ultrasound but lower imaging depth such as 1-2 mm. In order to image internal organs, OCT needs an endoscopic probe. In this paper, the principle of Fourier-domain optical coherence tomography with high-speed imaging capability was introduced. An OCT endoscope based on MEMS technology was developed. It was attached to the Fourier-domain OCT system to acquire three-dimensional tomographic images of gastrointestinal tract of New Zealand white rabbit. The endoscope had a two-axis scanning mirror that was driven by electrostatic force. The mirror stirred an incident light to sweep two-dimensional plane by scanning. The outer diameter of the endoscope was 6 mm and the mirror diameter was 1.2 mm. A three-dimensional image rendered by 200 two-dimensional tomographs with $200{\times}500$ pixels was displayed within 3.5 seconds. The spatial resolution of the OCT system was 8 ${\mu}m$ in air.

Bradycardia after Dobutamine Administration in a Dog (Dobutamine 투여 후 발생한 개의 서맥 1례)

  • Jang, Min;Son, Won-Gyun;Hwang, Hyeshin;Jo, Sang-Min;Yi, Kang-Jae;Yoon, Junghee;Lee, Inhyung
    • Journal of Veterinary Clinics
    • /
    • v.31 no.4
    • /
    • pp.350-353
    • /
    • 2014
  • A 13-year-old, castrated male, Shih Tzu dog with a history of acute ataxia was referred to veterinary medical teaching hospital and anesthetized for diagnostic magnetic resonance imaging of cervical intervertebral disk disease. After preanesthetic evaluation including physical examination, blood chemistry, radiography and ultrasound, the patient was premedicated with intravenous butorphanol (0.2 mg/kg). Anesthesia was induced by intravenous propofol (6 mg/kg) and maintained with isoflurane at 1.2 minimal alveolar concentrations. Because the mean arterial pressure (MAP) decreased from 70 to 58 mmHg at 70 minutes after induction, dobutamine was administered by constant rate infusion ($5{\mu}g/kg/min$) to treat hypotension. However MAP did not increase, and heart rate rapidly decreased from 100 to 55 beats per minute (bpm). To treat bradycardia, intravenous glycopyrrolate ($5{\mu}g/kg$) was administered, and heart rate increased to 165 bpm. After extubation of endotracheal tube, the patient showed normal recovery without any problems related to cardiovascular system. Unexpected dobutamine-induced bradycardia was considered as Bezold-Jarisch reflex. It is recommended that clinicians know and prepare the possibility of bradycardia during dobutamine therapy under general anesthesia.

Construction of Static 3D Ultrasonography Image by Radiation Beam Tracking Method from 1D Array Probe (1차원 배열 탐촉자의 방사빔추적기법을 이용한 정적 3차원 초음파진단영상 구성)

  • Kim, Yong Tae;Doh, Il;Ahn, Bongyoung;Kim, Kwang-Youn
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.2
    • /
    • pp.128-133
    • /
    • 2015
  • This paper describes the construction of a static 3D ultrasonography image by tracking the radiation beam position during the handy operation of a 1D array probe to enable point-of-care use. The theoretical model of the transformation from the translational and rotational information of the sensor mounted on the probe to the reference Cartesian coordinate system was given. The signal amplification and serial communication interface module was made using a commercially available sensor. A test phantom was also made using silicone putty in a donut shape. During the movement of the hand-held probe, B-mode movie and sensor signals were recorded. B-mode images were periodically selected from the movie, and the gray levels of the pixels for each image were converted to the gray levels of 3D voxels. 3D and 2D images of arbitrary cross-section of the B-mode type were also constructed from the voxel data, and agreed well with the shape of the test phantom.

Comparison of Abdominal Muscle Thickness Using Ultrasound Imaging During Bridging Exercises With a Sling and Ball in Healthy Young Adults

  • Moon, Young;Choi, Jong-duk
    • Physical Therapy Korea
    • /
    • v.27 no.1
    • /
    • pp.87-92
    • /
    • 2020
  • Background: Bridging exercises are used to enhance the functional stability of the lumbopelvic region in clinical settings. Although most of the studies on bridging exercises have compared the complete activation of the trunk muscles, some recent studies have examined the functional stability of the trunk and the lumbopelvic region and assessed the appropriate recruitment of the local and global muscles during different task levels. Objects: The purpose of this study was to investigate the changes in muscle thickness in the transverse abdominis (TrA), internal oblique (IO), and external oblique (EO) muscles during a common bridging exercise on an unstable surface and to determine whether these changes differ based on the surface used. Methods: Twenty-five healthy young adults (8 males, 17 females) were recruited. The subjects were randomly assigned to either the exercise progression with a sling bridge group or the ball bridging exercise progression group, each with three stages of increasing difficulty. Each position was measured three times with an ultrasonic diagnostic imaging system, and the mean values were recorded for analysis. Results: No significant differences were observed between the TrA, IO, or EO muscle thickness ratios between the sling and ball exercise groups (p > 0.05). There were also no significant differences in the EO muscle thickness ratios between the tasks irrespective of whether the sling or ball was used. However, the TrA and IO thickness ratios in both groups were significantly greater during stages 2 and 3 compared to stage 1. Conclusion: The results suggest that the use of slings and balls during bridging exercises is effective in activating the deep abdominal muscles.